Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIODE LASERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A tunable diode laser system for aircraft measurements of trace gases

The advantages of tunable-diode-laser absorption spectrometry (TDLAS) for measuring trace atmospheric gases are universality, positive identification, good sensitivity, and rapid response time. A TDLAS system is described which is capable of making measurements aboard an aircraft. The instrument was employed during the Chemical Instrumentation Test and Evaluation (CITE) 2 program to measure NO2 on 11 flights and HNO3 on five flights. Detection limits were determined to be 25 parts per trillion by volume (pptv) for NO2 and 75 pptv for HNO3 with response times of 3 min. This was sufficient to permit measurements of NO2 in the free troposphere and HNO3 in the continental boundary layer a significant fraction of the time.

Schiff, H. I.↗

Linear laser diode arrays for improvement in optical disk recording

The development of individually addressable laser diode arrays for multitrack magneto-optic recorders for space stations is discussed. Three multi-element channeled substrate planar (CSP) arrays with output power greater than 30 mW with linear light vs current characteristics and stable single mode spectra were delivered to NASA. These devices have been used to demonstrate for the first time the simultaneous recording of eight data tracks on a 14-inch magneto-optic erasable disk. The yield of these devices is low, mainly due to non-uniformities inherent to the LPE growth that was used to fabricate them. The authors have recently developed the inverted CSP, based on the much more uniform MOCVD growth techniques, and have made low threshold quantum well arrays requiring about three times less current than the CSP to deliver 30 mW CW in a single spatial mode. The inverted CSP is very promising for use in space flight recorder applications.

Alphonse, G. A.↗

Data processing and calibration for tunable diode laser harmonic absorption spectrometers

Data processing and calibration methods are described for tunable diode laser absorption spectrometers which produce harmonic absorption spectra as raw data for measuring gas mixing ratios down to parts-per-trillion levels at a variety of pressures. The methods, which take advantage of modern computer speed, memory, and data storage capabilities, are applicable to the detection of weakly absorbing gases in quantitative industrial monitoring, in addition to aircraft and balloon atmospheric measurements for which they were designed. Algorithms for calibration and data analysis, including rejection of erroneous spectra, variation of effective integration time, spectral alignment prior to averaging, and plotting and archiving of results, have been tested on actual stratospheric laser spectra recorded by the Aircraft Laser Infrared Absorption Spectrometer (ALIAS) spectrometer in numerous flights of NASA's ER-2 aircraft.

May, Randy D.↗

High power diode laser Master Oscillator-Power Amplifier (MOPA)

High power multiple quantum well AlGaAs diode laser master oscillator - power amplifier (MOPA) systems were examined both experimentally and theoretically. For two pass operation, it was found that powers in excess of 0.3 W per 100 micrometers of facet length were achievable while maintaining diffraction-limited beam quality. Internal electrical-to-optical conversion efficiencies as high as 25 percent were observed at an internal amplifier gain of 9 dB. Theoretical modeling of multiple quantum well amplifiers was done using appropriate rate equations and a heuristic model of the carrier density dependent gain. The model gave a qualitative agreement with the experimental results. In addition, the model allowed exploration of a wider design space for the amplifiers. The model predicted that internal electrical-to-optical conversion efficiencies in excess of 50 percent should be achievable with careful system design. The model predicted that no global optimum design exists, but gain, efficiency, and optical confinement (coupling efficiency) can be mutually adjusted to meet a specific system requirement. A three quantum well, low optical confinement amplifier was fabricated using molecular beam epitaxial growth. Coherent beam combining of two high power amplifiers injected from a common master oscillator was also examined. Coherent beam combining with an efficiency of 93 percent resulted in a single beam having diffraction-limited characteristics. This beam combining efficiency is a world record result for such a system. Interferometric observations of the output of the amplifier indicated that spatial mode matching was a significant factor in the less than perfect beam combining. Finally, the system issues of arrays of amplifiers in a coherent beam combining system were investigated. Based upon experimentally observed parameters coherent beam combining could result in a megawatt-scale coherent beam with a 10 percent electrical-to-optical conversion efficiency.

Andrews, John R.↗

Highly Sensitive Tunable Diode Laser Spectrometers for In Situ Planetary Exploration

This paper describes highly sensitive tunable diode laser spectrometers suitable for in situ planetary exploration. The technology developed at JPL is based on wavelength modulated cavity enhanced absorption spectroscopy. It is capable of sensitively detecting chemical signatures of life through the abundance of biogenic molecules and their isotopic composition, and chemicals such as water necessary for habitats of life. The technology would be suitable for searching for biomarkers, extinct life, potential habitats of extant life, and signatures of ancient climates on Mars; and for detecting biomarkers, prebiotic chemicals and habitats of life in the outer Solar System. It would be useful for prospecting for water on the Moon and asteroids, and characterizing its isotopic composition. Deployment on the Moon could provide ground truth to the recent remote measurements and help to uncover precious records of the early bombardment history of the inner Solar System buried at the shadowed poles, and elucidate the mechanism for the generation of near-surface water in the illuminated regions. The technology would also be useful for detecting other volatile molecules in planetary atmospheres and subsurface reservoirs, isotopic characterization of planetary materials, and searching for signatures of extinct life preserved in solid matrices.

Vasudev, Ram↗

A shock isolator for diode laser operation on a closed-cycle refrigerator

A device developed to isolate the diode laser from impact shocks delivered during the expansion phase of the Solvay cycle of a helium refrigerator is briefly described. The device uses intermediate cold stations in the stand-off, which permit the stand-off to be short and rigid while minimizing the thermal load at the diode mount.

Jennings, D. F.↗

Linewidth measurements of tunable diode lasers using heterodyne and etalon techniques

Measurements of the linewidths of Pb-salt diode lasers operating in the 8- and 9-micron region are reported. The linewidths of the 9-micron lasers were determined by conventional heterodyne techniques, while for the 8-micron lasers a new technique based on a Fabry-Perot etalon was used. The new technique avoids the complexity and limited wavelength range of the heterodyne measurements and can be used for any tunable laser. The linewidths observed varied from 0.6 to more than 500-MHz FWHM. The linewidth was found to vary dramatically from device to device, to depend strongly on junction temperature and injection current, and to be correlated with vibrations caused by operation of a closed-cycle refrigerator.

Reid, J.↗

Development of long wavelength semiconductor diode lasers near 28 microns for use in infrared heterodyne spectrometers

The development of tunable diode lasers operating in the 28 micrometers spectral region for use in infrared heterodyne spectrometers is reported. A process capable of yielding lasers emitting 500 micron W of multimode power, 112 micron W in a true single mode and true single mode operation at laser currents of up to 35% above threshold was developed. Results were obtained from narrow mesastripe (20 micrometer wide) short cavity (120 micrometer length) laser configurations. Six stripe geometry lasers, with a variety of cavity widths and lengths were delivered. The techniques to fabricate such devices was obtained and the long term reliability of such lasers by reproducible electrical and optical output characteristics fabrication from lasers are demonstrated.

Linden, K. J.↗

Single mode, short cavity, Pb-salt diode lasers operating in the 5, 10, and 30-microns spectral regions

Pb-salt diode lasers are being used as frequency-tunable infrared sources in high resolution spectroscopy and heterodyne detection applications. Recent advances in short cavity, stripe-geometry laser configurations have led to significant increases in maximum CW operating temperature, single mode operation, and increased single mode tuning range. This paper describes short cavity, stripe geometry lasers operating in the 5, 10, and 30-microns spectral regions, with single mode tuning ranges of over 6/cm.

Linden, K. J.↗

The determination of HNO3 column amounts from tunable diode laser heterodyne spectrometer spectra taken at Jungfruajoch, Switzerland

In May of 1991 a tunable diode laser heterodyne spectrometer built by the National Physical Laboratory was operated at the International Scientific Station of the Jungfraujoch (46.5 deg N, 8.0 deg E, altitude 3.56 km). Nitric acid spectra in the region of 868 wavenumbers were recorded at sunset and sunrise on two separate days at a resolution of 0.0013 wavenumbers with a signal-to-noise ratio of approximately 130:1. A vertical column amount of HNO3 of 1.61 x 10(exp 16) molecules/sq cm was determined using an atmospheric transmission model developed at the University of Denver. The mean of a number of mid-latitude, northern hemisphere profiles was used as the initial profile for the inversion. A comparison of different initial profiles provides information on the sensitivity of the retrieved column amount of 1.61 x 10(exp 16) molecules/sq cm lies within the range of values published in the World Meteorological Organization Report no. 16 (1986), but is considerably larger than the value of (0.99 - 1.29) x 10(exp 16) reported by Rinsland et al. (1991) for June during the period 1986 to 1990.

Fogal, P. F.↗

Development of ion-implantation confined, shallow mesa stripe (Pn,Sn)Te/Pb(Te,Se) DH laser diodes

Preliminary results of a program to develop ion implantation confined, shallow mesa stripe (Pb,Sn)Te laser diodes are presented. The practicality of using a shallow mesa stripe to produce single mode laser output and to increase the single mode tuning range are demonstrated. The first results of p-type ion implantation in the lead-tin salts are also reported. It is shown that sodium and lithium both can be used to convert n-type Pb(Te,Se) to p-type. The implant and anneal procedures are described, and electrical characteristics of Li-implanted layers are presented.

Fonstad, C. G.↗

Broad-Area Laser Diode With Fiber-Optic Injection

Fiber-optic injection-locked broad-area laser diode features single-mode output via fiber-optic injection and serves as compact, rugged, high-power near-infrared source. Useful in free-space and fiber-optic communication links, as communication-receiver preamplifier, and pump source for solid-state lasers.

Hazel, Geoffrey↗

Electrooptic modulation methods for high sensitivity tunable diode laser spectroscopy

A CdTe phase modulator and low power RF sources have been used with Pb-salt tunable diode lasers operating near 8 microns to generate optical sidebands for high sensitivity absorption spectroscopy. Sweep averaged, first-derivative sample spectra of CH4 were acquired by wideband phase sensitive detection of the electrooptically (EO) generated carrier-sideband beat signal. EO generated beat signals were also used to frequency lock the TDL to spectral lines. This eliminates low frequency diode jitter, and avoids the excess laser linewidth broadening that accompanies TDL current modulation frequency locking methods.

Glenar, David A.↗

Continuous-Wave Single-Frequency Operation of Fabry-Perot Laser Diodes by Self-Injection Phase Locking Using Feedback from a Fiber Bragg Grating

Single-frequency operation of uncoated Fabry-Perot laser diodes is demonstrated by phase- locking the laser oscillations through self-injection seeding with feedback from a fiber Bragg grating. By precisely tuning the laser temperature so that an axial-mode coincides with the short-wavelength band edge of the grating, the phase of the feedback is made conjugate to that of the axial mode, locking the phase of the laser oscillations to that mode.

Duerksen, Gary L.↗

High sensitivity detection of trace gases at atmospheric pressure using tunable diode lasers

A detailed study of the detection of trace gases at atmospheric pressure using tunable diode lasers is described. The influence of multipass cells, retroreflectors and topographical targets is examined. The minimum detectable infrared absorption ranges from 0.1 percent for a pathlength of 1.2 km to 0.01 percent over short pathlengths. The factors which limit this sensitivity are discussed, and the techniques are illustrated by monitoring atmospehric CO2 and CH4.

Reid, J.↗

High-power diode lasers for optical communications applications

High-power, single-mode, double-heterojunction AlGaAs diode lasers are being developed to meet source requirements for both fiber optic local area network and free space communications systems. An individual device, based on the channeled-substrate-planar (CSP) structure, has yielded single spatial and longitudinal mode outputs of up to 90 mW CW, and has maintained a single spatial mode to 150 mW CW. Phase-locked arrays of closely spaced index-guided lasers have been designed and fabricated with the aim of multiplying the outputs of the individual devices to even higher power levels in a stable, single-lobe, anastigmatic beam. The optical modes of the lasers in such arrays can couple together in such a way that they appear to be emanating from a single source, and can therefore be efficiently coupled into optical communications systems. This paper will review the state of high-power laser technology and discuss the communication system implications of these devices.

Carlin, D. B.↗

Stable isotope analysis using tunable diode laser spectroscopy

Ratios of C-12/C-13 in CO2 have been measured using a tunable diode laser (TDL) spectrometer to an accuracy of better than 0.4 percent. These results were made possible by the use of state-of-the-art high-temperature TDLs, an etalon and wavenumber calibration technique, high-speed assembly language controlled data acquisition, and the ratioing of absorbances from simultaneously acquired sample and reference data scans. The dual beam spectrometer that is employed uses the sweep integration technique in a spectral region where adjacent spectral lines are of approximately equal absorbance at the expected isotopic abundances.

Becker, Joseph F.↗

Measurements of Trace Gases Using a Tunable Diode Laser

This report is the final report for "Measurements of Trace Gases Using a Tunable Diode Laser." The tasks outlined in the proposal are listed below with a brief comment. The publications and the conference presentations are listed. Finally, the important publications are attached. The Cooperative Agreement made possible a research effort to produce high- precision and high-accuracy in-situ measurements of carbon monoxide, methane and nitrous oxide on the WB-57 during the CRYSTAL-FACE and pre-AVE field campaigns and to analyze these measurements. These measurements of CO and CH4 were of utmost importance to studies of the radiative effects of clouds. Some important results of the CRYSTAL-FACE program were contained in two scientific papers (attached). This Cooperative Agreement allowed the participation of the Argus instrument in the program and the analysis of the data.

Jost, Hans-Juerg↗