Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVAPORATION RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences↗

Calculation of Nuclear Reactor Cooling Tower Performance With Limited Data Streams

Monitoring of cooling tower performance in a nuclear reactor facility is necessary to ensure safe operation; however, instrumentation for measuring performance characteristics can be difficult to install and may malfunction or break down over long duration experiments. This paper describes employing a thermodynamic approach to quantify cooling tower performance, the Merkel model, which requires only five parameters, namely, inlet water temperature, outlet water temperature, liquid mass flowrate, gas mass flowrate, and wet bulb temperature. Using this model, a general method to determine cooling tower operation for a nuclear reactor was developed in situations when neither the outlet water temperature nor gas mass flowrate are available, the former being a critical piece of information to bound the Merkel integral. Furthermore, when multiple cooling tower cells are used in parallel (as would be in the case of large-scale cooling operations), only the average outlet temperature of the cooling system is used as feedback for fan speed control, increasing the difficulty of obtaining the outlet water temperature for each cell. To address these shortcomings, this paper describes a method to obtain individual cell outlet water temperatures for mechanical forced-air cooling towers via parametric analysis and optimization. In this method, the outlet water temperature for an individual cooling tower cell is acquired as a function of the liquid-to-gas ratio (L/G). Leveraging the tight tolerance on the average outlet water temperature, an error function is generated to describe the deviation of the parameterized L/G to the highly controlled average outlet temperature. The method was able to determine the gas flowrate at rated conditions to be within 3.9% from that obtained from the manufacturer’s specification, while the average error for the four individual cooling cell outlet water temperatures were 1.6 °C, -0.5 °C, -1.0 °C, and 0.3 °C.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mining Air for Fuels and Fine Chemicals

The Intergovernmental Panel on Climate Change’s 2021 report underscores that Direct Air Capture (DAC) is an essential component to limiting global warming to 2 °C, yet separating CO 2 from air and its subsequent concentration for conversion into carbon neutral fuels/chemicals or permanent storage remains energy intensive and costly. Further, most DAC technologies rely on repetitive capture and release cycles that reduces the amount of time the DAC materials are able to collect CO 2 and increases wear and tear. Moisture swing (MS) sorption within anion exchange materials utilizes differences in relative humidity to capture and concentrate CO 2 up to 500-fold with negligible energy inputs and low-cost sorbents. Molecular modeling predicts that membranes with a dry and wet side would actively transport CO 2 from its dry side to its wet side against a counter flow of H 2 O evaporating on the dry side, however, existing MS materials are too brittle to be processed into membranes to test this hypothesis. This project brought together experts in DAC materials and design, techno-economic analysis and project management at Arizona State University (ASU), polymer processing at University of Texas at Austin (UTA) and modeling gas transport and exchange at Norther Arizona University (NAU) to develop hollow fiber membranes that use energy from water evaporation to continuously pump CO 2 from air against a concentration gradient to the membranes interior and requiring significantly less energy than current DAC technologies. While this project did not meet its ultimate objectives of demonstrating an active CO 2 pumping membrane, a number of key accomplishments were made in developing low-cost, flexible anion exchange membranes (AEM) at 3.5 m 2 scale, characterizing the ionic and molecular transport within MS materials, and developing several analytical and mathematical models of the MS and pumping process leading to new fundamental knowledge about key rate limiting steps of CO 2 flux in anion exchange membranes at low water activity. Technoeconomic models show that if CO 2 fluxes ≥ 25 µmol CO 2 m -2 s -1 (membrane surface area) are achieved that cost ≤ $\$$100/tonne CO 2 captured, purified and compressed to pipeline quality is possible. The knowledge gained in this research will guide future research in developing new materials toward overcoming these rate limiting steps that in turn could enable transformative and disruptive DAC technologies needed for capturing gigatons of CO 2 per year needed to limiting global warming to 2 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of laser scanning speed on the microstructure, phase transformation and mechanical property of NiTi alloys fabricated by $\mathrm{LPBF}$

This study investigated the effects of laser scanning speed on the microstructure, phase transformation and properties of NiTi alloys fabricated by laser powder bed fusion (LPBF). In this study, the contributions of metallurgical factors under different scanning speeds, such as Ni evaporation, Ni4Ti3 precipitation, dislocations and internal stress, to the transformation temperature and transformation latent heat were clarified through specially designed experiments. Ni evaporation is found to have the most profound effect, followed by precipitation. Increasing scanning speed is found to reduce Ni loss, thus cause less increase in the transformation temperature and transformation heat of the LPBF-NiTi alloys. Increasing scanning speed also increases the microstructure non-uniformity and thus widens the transformation temperature interval. The orientations of residual stress exhibit strong crystallographic stiffness dependence. The LPBF-NiTi alloys with different scanning speeds all exhibited high strains (>13.4%) and excellent shape memory effect. A LPBF-NiTi honeycomb structure exhibited 96% shape recovery rate after a 60% pre-compressive deformation. Besides, there is an optimum scanning speed for minimum porosity and smallest average pore size. However, the pore structure is found to have weak influence on the tensile behaviour of the LPBF-NiTi alloys, possibly due to the high defect tolerance of the martensitic transformation.

36 MATERIALS SCIENCE↗

Experiments and Simulations of Droplet Burning of Isobutanol Mixed with a Tier II Gasoline Certification Fuel and its Surrogate, Paper Number: SHTC2023-115267

This study presents an experimental and numerical results of combustion dynamics of a Tier II certification fuel/iso-butanol mixtures and its surrogate(S5)/iso-butanol mixtures. The experiments were carried out where gas transport was determined entirely by fuel evaporation to promote spherical symmetry during the burning process. The droplet initial diameters were in the range 0.55 mm to 0.62 mm. The combustion characteristics such as droplet diameters, flame standoff ratios and soot shell standoff ratios of indolene/iso-butanol mixtures are compared with S5/iso-butanol mixtures and the implications of iso-butanol addition to indolene and S5 on combustion are discussed. The presence of iso-butanol is experimentally found to reduce the formation of soot as the iso-butanol concentration was increased and the iso-butanol addition insignificantly influence the burning rate. Simulations were carried out with the detailed kinetic chemistry (324 species and 17608 reactions) from POLIMI. The detailed numerical model included unsteady gas and liquid transport, soot chemistry and radiative transport. The impact of iso-butanol on the burning rate, flame structure and soot formation are presented. Droplet burn rates were well predicted while flame diameters showed more variability depending on how the flame was defined in the numerical simulation (peak gas temperature and OH concentration). Simulations also show the influence of iso-butanol concentration on flame temperature, greenhouse gas emissions and soot formations.

Guo, Songtao↗

Lignin molecular weights of Populus trichocarpa residues after CELF pretreatment

Here we present a dataset of molecular weights of lignin from a woody energy crop (Populus trichocarpa) residues after a series of co-solvent enhanced lignocellulosic fractionation (CELF) pretreatment. The natural poplar variant GW-9947 from the Center for Bioenergy Innovation (CBI) was used. The poplar was knife milled and passed through a 1 mm sieve and CELF pretreatment was performed in a Parr autoclave reactor with 7.5 wt % solids loading, 0.5 wt% H2SO4 as catalyst at 150°C with various time. Tetrahydrofuran was added in a 1:1 mass ratio with water as the pretreatment solvent. Lignin was isolated from the pretreated samples after ball-milling in a porcelain jar with ceramic balls via Retsch PM 200 at 580 rpm for 2.5 h followed by enzymatic hydrolysis in acetate buffer (pH 4.8, 50 °C) for 48 h. The solid residue was isolated by centrifugation and hydrolyzed again with freshly added buffer and enzymes for another 48 h. After filtration, the solid residue was extracted twice with 96% (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover lignin. The lignin samples were then derivatized in an acetic anhydride/pyridine (1:1, v/v) mixture and stirred at room temperature for 24 h. Ethanol was added to the reaction mixture, left for 30 min and then removed with a rotary evaporator. The addition and removal of ethanol was repeated at least 3 times until all traces of acetic acid were removed. Acetylated lignin samples were then dissolved in tetrahydrofuran (THF) at a concentration of 1.0 mg/mL. The molecular weight of acetylated lignin was measured by a gel permeation chromatography (GPC) on a PSS-Polymer Standards Service (Warwick, RI, USA) GPC SECurity 1200 system featuring Agilent HPLC 1200 components equipped with four Waters Styragel columns (HR1, HR2, HR4 and HR6) and an UV detector (270 nm). Tetrahydrofuran was used as the mobile phase and flow rate was 0.3 mL/min. The Polymer Standards Service WinGPC Unity software (Build 6807) was used for data processing for all the samples. The data provides information about the effects of CELF pretreatment time at 150 ºC on lignin molecular weights.

09 BIOMASS FUELS↗

Heat pump water heater enhanced with phase change materials thermal energy storage: Modeling study

A promising solution to improve the first hour rating (FHR) of a heat pump water heater (HPWH) involves employing a secondary tank which contains phase change material (PCM) capsules. To better understand the influence of PCM thermal storage on the HPWH operational performance, a dynamic model was developed to simulate and analyze the behavior of a newly developed HPWH technology that incorporates PCM storage into a standard HPWH to optimize key parameters such as the uniform energy factor and FHR. Mathematical models of several key components of the proposed HPWH-PCM integrated thermal energy storage (TES) system, e.g., water heater tank, PCM TES tank, evaporator, compressor, and expansion valve, have been elaborated. Also, a model-based control co-simulation platform was developed to integrate a embed PCM storage HPWH dynamic model with a control model for better supporting control design, analysis, verification, and validation. The model accuracy has been validated through comparing simulation results with lab test results, with a mean average percentage error of <5.5% for most of the selected performance variables. In addition, using the developed co-simulation platform, the demand response control strategy was studied to evaluate the load flexibility of the combined HPWH-PCM storage system by shifting system power usage to outside of the 3.5 h peak load period.

25 ENERGY STORAGE↗

Sunlight-absorbing aerosol amplifies the seasonal cycle in low-cloud fraction over the southeast Atlantic

Abstract. The mean altitude of the smoke loading over the southeast Atlantic moves from the boundary layer in July to the free troposphere by October. This study details the month-by-month changes in cloud properties and the large-scale environment as a function of the biomass burning aerosol loading at Ascension Island (8∘ S, 14.5∘ W) from July to October, based on island measurements, satellite retrievals, and reanalysis. In July and August, the smoke loading predominantly varies within the boundary layer. During both months, the low-cloud fraction is less and is increasingly cumuliform when more smoke is present, with the exception of a late morning boundary layer deepening that encourages a short-lived cloud development. The meteorology varies little, suggesting aerosol–cloud interactions explain the cloudiness changes. September marks a transition month during which midlatitude disturbances can intrude into the Atlantic subtropics, constraining the free tropospheric aerosol closer to the African coast. Stronger boundary layer winds on cleaner days help deepen, dry, and cool much of the marine boundary layer compared to that on days with high smoke loadings, with stratocumulus reducing everywhere but at the northern deck edge. The September free troposphere is better mixed on smoky days compared to October. Longwave cooling rates, generated by a sharp water vapor gradient at the aerosol layer top, encourage a small-scale vertical mixing that could help maintain the well-mixed smoky September free troposphere. The October meteorology primarily varies as a function of the strength of the free tropospheric winds advecting aerosol offshore. The free tropospheric aerosol loading is less than in September, and the moisture variability is greater. Low-level clouds increase and are more stratiform in October when the smoke loadings are higher. The increased free tropospheric moisture can help sustain the clouds through a reduction in evaporative drying during cloud-top entrainment. Enhanced subsidence above the coastal upwelling region, increasing cloud droplet number concentrations, may further prolong cloud lifetime through microphysical interactions. Reduced subsidence underneath stronger free tropospheric winds at Ascension Island supports slightly higher cloud tops during smokier conditions. Overall, the monthly changes in the large-scale aerosol and moisture vertical structure act to amplify the seasonal cycle in low-cloud amount and morphology. This is climatically important, as cloudiness changes dominate changes in the top-of-atmosphere radiation budget.

54 ENVIRONMENTAL SCIENCES↗

A Simulation Study of 120V Heat Pump Water Heaters

A 120 V heat pump water heater (HPWH) is a direct plug-in option to replace gas water heater (WH) without needing expensive electric panel upgrade to 220 V. To enable the smooth transition, the HPWH should provide comparable water heating capacity as the gas WH. WH capacities are rated in the form of first hour rating (FHR). Typical home gas WHs have FHRs > 65 gallon with a 40-gallon water tank. It imposes a major challenge on 120V HPWHs. Most 120V circuits in US can provide 1,800 to 2,400W, not adequate to drive electric resistance heat to boost FHRs. Thus, all the heat needs to come from the heat pump with its top power below 1500 Watts, which is constraint by the installation footprint. This study uses a hardware based, HPWH design model, i.e. the DOE/ORNL Heat Pump Design Model to design a 120V unit with a brazed plate condenser, fin-and-tube evaporator and an adequately sized compressor. To maximize the FHR, multiple strategies were simulated, including use of a mixing valve, overheating the tank temperature to 140F, a new sensing method for quicker response, and an innovative water circulation path. We also simulated 24-hour unform energy factors (UEF) to show the tradeoff between the capacity and operation efficiency. Additionally, we evaluated the impact of insulation thickness on FHR and UEF, to seek further footprint reduction or stretch the tank volume.

Shen, Bo↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational fluid dynamics modeling and analysis of silica nanoparticle synthesis in a flame spray pyrolysis reactor

Flame Spray Pyrolysis (FSP) is a method for large-scale production of nanoparticles and nanoscale powders employed in a wide range of industrial applications. Particle size and morphology are complex functions of the physicochemical phenomena occurring in the FSP reactor. An extensive study of FSP-related phenomena can be utilized to develop effective strategies for achieving desired particle size/morphology and scaling up the overall yield of an FSP system. In this work, a computational fluid dynamics (CFD) model of an FSP reactor is developed to simulate the coupling of key phenomena involved in the particle synthesis process: liquid spray breakup and evaporation, mixing, combustion, and particle formation/growth of silica nanoparticles. Herein, the particle sizes and their distributions from the CFD simulations are validated against experimental data. Subsequently, the simulations are utilized to investigate the impact of process parameters on the resultant flame dynamics and particle growth. Firstly, the CFD results show that the particle sizes are strongly correlated with the precursor concentration in the solvent. At lower precursor concentrations, the spread of the distribution is relatively insensitive to the value of the concentration. At higher concentrations, the spread is higher as the collision probability between particles is higher. Secondly, increasing the pilot flow rate increases the length of the pilot flames impacting the local ignition location of the spray flame. Lastly, it is shown that the dispersion gas flow rate strongly influences the spray flame shape. This shape can be used for control of particle growth as it helps determine the regions of high temperature and the residence time of the particles in the high temperature region enabling the design and process optimization of the FSP reactor.

42 ENGINEERING↗

Multifaceted aerosol effects on precipitation

Aerosols have been proposed to influence precipitation rates and spatial patterns from scales of individual clouds to the globe. However, large uncertainty remains regarding the underlying mechanisms and importance of multiple effects across spatial and temporal scales. Here, in this study, we review the evidence and scientific consensus behind these effects, categorized into radiative effects via modification of radiative fluxes and the energy balance, and microphysical effects via modification of cloud droplets and ice crystals. Broad consensus and strong theoretical evidence exist that aerosol radiative effects (aerosol–radiation interactions and aerosol–cloud interactions) act as drivers of precipitation changes because global mean precipitation is constrained by energetics and surface evaporation. Likewise, aerosol radiative effects cause well-documented shifts of large-scale precipitation patterns, such as the intertropical convergence zone. The extent of aerosol effects on precipitation at smaller scales is less clear. Although there is broad consensus and strong evidence that aerosol perturbations microphysically increase cloud droplet numbers and decrease droplet sizes, thereby slowing precipitation droplet formation, the overall aerosol effect on precipitation across scales remains highly uncertain. Global cloud-resolving models provide opportunities to investigate mechanisms that are currently not well represented in global climate models and to robustly connect local effects with larger scales. This will increase our confidence in predicted impacts of climate change.

54 ENVIRONMENTAL SCIENCES↗

The effect of relative humidity and temperature on the response of stomatal conductance to vapor pressure deficit in tropical trees

Understanding how leaf gas exchange responds to changes in vapor pressure deficit (VPD) is key to predicting tropical forest resilience to climate change. Stomata regulate leaf water and CO2 diffusion, and respond to changes in temperature and relative humidity (RH), two drivers of VPD. At high temperatures, the cuticular pathway may also become significant and participate in the overall leaf conductance. Here, we measured gas exchange under light and dark conditions to investigate the stomatal and cuticular responses to temperature and RH on detached branches in five tropical tree species. Leaf conductance in the dark, when stomata are essentially closed, was not markedly impacted by temperature and RH, suggesting a minimal response of the cuticular pathway to these conditions. We compared six steady-state conductance models incorporating different effects of photosynthesis and evaporative demand on stomatal control. All models performed well (residual standard deviation, σ, < 0.025 mol m-2 s-1), but the best-fitting model (σ = 0.017 mol m-2 s-1) used a nonlinear relationship between photosynthesis and stomatal conductance and incorporated RH rather than vapor pressure difference. All models overestimated the steady-state conductance at high RH. Furthermore, leaf conductance immediately increased after a decrease in RH (wrong-way response), but not after an increase in leaf temperature. This suggests that the mechanisms underlying stomatal response to VPD need further investigation. The non-linear coupling between photosynthetic rate and stomatal conductance indicates a sharper physiological response than previously acknowledged.

Lamour, Julien↗

Secondary Organic Aerosol from OH Oxidation of Acyclic Terpenes Is More Viscous and Less Volatile than That of Their Cyclic Analogs

Biogenic volatile organic compounds (BVOCs), a dominant source of secondary organic aerosol (SOA) globally, exhibit emission rates and composition that are plant species-specific and vary with environmental stressors. A common outcome of plant stress is increased emissions of acyclic terpenes. The paucity of information about acyclic terpene SOA chemistry contributes to uncertainties in predictions of SOA global loadings and impacts on Earth’s radiative budget, particularly in a changing climate where acyclic terpene emissions could become more prominent. This study compared properties of SOA derived from OH oxidation of acyclic and cyclic monoterpenes (ß-ocimene, a-pinene) and sesquiterpenes (ß-farnesene, ß-caryophyllene). Single particle mass spectrometry was used for assessing shape, density, and evaporation kinetics of size-selected SOA particles, and nanospray desorption electrospray ionization high-resolution mass spectrometry (nano-DESI-HRMS) was used to measure molecular composition of SOA. Acyclic terpene SOA exhibited higher viscosity and lower volatility compared to cyclic terpene SOA, and had a greater volume fraction remaining (VFR) after ~24 hours of evaporation - approximately 1.3-1.6 times higher VFR than that of cyclic terpene SOA. Additionally, HRMS analysis revealed greater chemical diversity and higher fractions of extremely low volatility compounds (56-62% ELVOC/LVOC) in acyclic terpene SOA compared to cyclic counterparts (25-37% ELVOC/LVOC). Our findings highlight the potential importance of accounting for acyclic terpene aerosol chemistry under conditions of plant stress to improve predictions of SOA loadings and impacts.

SOA physical properties↗

Cloud microphysical response to entrainment and mixing is locally inhomogeneous and globally homogeneous: Evidence from the lab

Entrainment of dry air into clouds strongly influences cloud optical and precipitation properties and the response of clouds to aerosol perturbations. The response of cloud droplet size distributions to entrainment–mixing is examined in the Pi convection-cloud chamber that creates a turbulent, steady-state cloud. The experiments are conducted by injecting dry air with temperature (T e ) and flow rate (Q e ) through a flange in the top boundary, into the otherwise well-mixed cloud, to mimic the entrainment–mixing process. Due to the large-scale circulation, the downwind region is directly affected by entrained dry air, whereas the upwind region is representative of the background conditions. Droplet concentration (Cn) and liquid water content (L) decrease in the downwind region, but the difference in the mean diameter of droplets (D m ) is small. The shape of cloud droplet size distributions relative to the injection point is unchanged, to within statistical uncertainty, resulting in a signature of inhomogeneous mixing, as expected for droplet evaporation times small compared to mixing time scales. As T e and Q e of entrained air increase, however, Cn, L, and D m of the whole cloud system decrease, resulting in a signature of homogeneous mixing. The apparent contradiction is understood as the cloud microphysical responses to entrainment and mixing differing on local and global scales: locally inhomogeneous and globally homogeneous. This implies that global versus local sampling of clouds can lead to seemingly contradictory results for mixing, which informs the long-standing debate about the microphysical response to entrainment and the parameterization of this process for coarse-resolution models.

54 ENVIRONMENTAL SCIENCES↗

Improving the characterization of fusion in a MuSIC detector by spatial localization

Multi-Sampling Ionization Chambers (MuSIC) provide an efficient means of measuring nuclear reactions with low beam rates (< 10 6 pps). However, in comparison to thin-target measurements, prior measurements using MuSIC detectors all manifest fusion excitation functions with wide error bars in the energy dimension. This uncertainty limits the applicability of these devices in measuring near and sub-barrier fusion cross-sections. Key to overcoming this limitation is spatial localization of the fusion in the detector. By comparing the measured ionization in the MuSIC detector with accurate energy loss calculations the position of the fusion in the detector is determined. The analysis not only provides the desired improvement in energy resolution, but it also allows extraction of the atomic number of the evaporation residues following fusion. Furthermore, the effectiveness of this approach is demonstrated for 18 O+ 12 C measured with MuSIC@Indiana.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of controlled prewetting on part formation in binder jet additive manufacturing

Binder jetting is an additive manufacturing process that bonds powder through selectively depositing binder by inkjet printing. The part is then extracted and densified by sintering and/or infiltration. The process offers low costs and fast build rates, but properties can be poor due to residual porosity after sintering. The inkjet printing process may contribute to this residual porosity by creating large pores. The droplet kinetic energy ejects some powder particles from the bed and rearranges others. Particle ejection and rearrangement are theorized to create porous regions in binder-jetted parts. In this work, small amounts of moisture are added to the spread powder before printing and the impact on part formation, part properties, and printing parameters measured with varied droplet spacing, droplet velocity, and print frequency. Moisture is added by applying an atomized fluid mixture to the powder between layer spreading and binder printing. The fluid mixture partially evaporates but leaves a stable residue to increase cohesion and enhance imbibition. Moisture addition to the powder increases the range of droplet spacings for line formation while reducing particle ejection, powder rearrangement, and balling in layer and multilayer parts. Excessive moisture addition decreases the effective saturation of printed lines, but saturation in 3D parts is less impacted. Increased surface roughness in the first few layers of a print was also mitigated with prewetting. Finally, high-speed X-ray imaging verified prewetting reduction in particle ejection and rearrangement.

36 MATERIALS SCIENCE↗

Energy considerations regarding pulsed arc production of nanomaterials

Atmospheric arc discharge volumes have been estimated from the light distribution emitted during evaporation of graphite and molybdenum disulphide (MoS 2 ) anodes. These data have been correlated to the peak power in the case of pulsed arc discharge held at different frequencies (1, 2 and 5 Hz). The measured power density values and the corresponding specific energies per particle have been compared to DC values, and showed that pulsed arc discharges deliver electrical power more efficiently than DC arc discharges do with yet lower thermal loads. In particular, the power density of ≈1 kW/cm 3 characteristic of pulsed arcs (10-20 kW/cm 3 in DC) suffices to provide 15 eV/particle to the arc plasma (≈10 eV/particle or less in DC). Such an energy balance resulted in high ionization rates of the ablated material and production yields of carbon nanotubes around 10 11 cm -2 kWh -1 . Lastly, in situ probe experiments showed that pulsed arcs enhance the transport to substrate of the generated nanoparticles, such as graphene and MoS 2 monolayers. Pulsed anodic arcs open the possibility to generate further nanomaterials thanks to a more rational power investment and a better control of the discharge region.

42 ENGINEERING↗