Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Lasing dynamics of diode-pumped Yb – Er laser with a passive Q switch exposed to high-power external light

The temporal dynamics of diode-side-pumped Yb – Er laser, with a passive Co{sup 2+} : MgAl{sub 2}O{sub 4} Q switch illuminated by a light beam (total fluence of 0.15 – 0.16 J cm{sup −2}) from a semiconductor pulsed module, is investigated. It is shown that, using this external illumination, one can change the lasing onset delay and the time jitter ΔT{sub gi}. The dependence of ΔT{sub gi} on the interval between the instant of switching the illumination module on and the lasing peak position t{sub i} has a minimum at |t{sub i}| ≈ 10 μs. The decrease in ΔT{sub gi} with a change in |t{sub i}| from 90 to 10 μs indicates that instant of lasing peak occurrence for the Yb – Er laser is partially controlled by the pulse from the highly stable semiconductor module. If |t{sub i}| < 10 μs, the enhanced luminescence fluence in the cavity of Yb – Er laser exceeds 0.16 J cm{sup −2}; the light beam from the module does not affect much the lasing process in the ytterbium – erbium laser; and, as a consequence, the time jitter recovers the initial value. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Destruction of absorbing metal films during laser printing with gel microdroplets

The degree of destruction and evaporation of metal films (Au and Ti, thickness ∼50 nm) with a gel layer during laser transfer of small volumes of a gel substrate is estimated depending on the laser fluence value. The dynamics of these processes for dry films and films with a gel layer at fluences close to threshold values is investigated using a probe beam of a He – Ne laser. It is shown that the presence of a gel leads to an increase in the ablation threshold, but the time during which the process of structural changes in the film material is completed does not change significantly. The results obtained can be used to improve the laser bioprinting technology. (interaction of laser radiation with matter)

36 MATERIALS SCIENCE↗

Validation of Light Water Reactor Ex-Core Calculations with VERA

The Consortium for Advanced Simulation of Light Water Reactors (CASL) Virtual Environment for Reactor Applications (VERA) is a reactor simulation software. It offers unique capabilities by combining high-fidelity in-core radiation transport with temperature feedback by using MPACT (a deterministic neutron transport code) and COBRA-TF (a thermal-hydraulic code) with follow-on, fixed-source transport calculations using the Shift Monte Carlo code to calculate ex-core quantities of interest. In these coupled calculations, MPACT provides Shift with the fission source for follow-on ex-core calculations. These ex-core simulations can be set up to calculate detector responses, as well as the flux and fluence in ex-core regions of interest, such as the reactor pressure vessel, nozzle, and irradiated capsules. A Watts Bar Nuclear Plant Unit 1 (WBN1) ex-core model was developed, as described in this paper, and this model was used to perform coupon calculations. The results for the coupon flux calculations show close agreement with the reference values for cycle 1 produced by the two-dimensional Discrete Ordinates Transport (DORT) code and presented in a BWXT Services Inc. report. However, differences in the results (10%) seen in cycles 2 and 3 and the reasons for these differences are discussed in this paper. The VERA WBN1 model was also used to perform a vessel fluence calculation for cycle 1. Additionally, a collaboration between CASL and Duke Energy led to the first code-to-code validation of VERA for reactor ex-core applications that used a model for the Shearon Harris reactor. Results from this collaboration show excellent agreement between VERA and the Monte Carlo N-Particle Transport Code for the detector response calculations. The work performed under this collaboration is also detailed in this paper.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Introduction, Investigation, and Experimental Validation of a Novel Passive Neutron Spectrometer

Unfolding neutron energy spectra are instrumental for determining personal health effects and calculating dose received. This area of study is heavily researched, and Lawrence Livermore National Laboratory (LLNL) is investigating a passive neutron spectrometer for the purpose of acquiring the information needed to determine personnel dose in the event of a criticality accident. A part of this investigation is presented in this article through the examination of four experimental detector responses (DRs). These four DRs were acquired in the presence of 252 Cf, AmBe, GODIVA, and National Ignition Facility (NIF) neutron sources. An algorithm developed at LLNL was used to unfold the neutron fluence from each of the four DRs, and subsequently, fluence-to-dose conversion factors provided by the American National Standards Institute were used to calculate dose. Additionally, a multistep unfolding process was developed and employed to calculate the effects of both direct (from the source) and indirect (from room return) neutrons. The average error when unfolding the direct DR was less than 8%. The dose from 252 Cf was predicted with only 8% error. The multistep approach allowed for the identification of the low-energy neutrons in the 252 Cf, AmBe, and NIF DRs.

Nuclear Criticality Safety Program (NCSP)↗

Heavy ion irradiation induced failure of gallium nitride high electron mobility transistors: effects of in-situ biasing

Abstract While radiation is known to degrade AlGaN/GaN high-electron-mobility transistors (HEMTs), the question remains on the extent of damage governed by the presence of an electrical field in the device. In this study, we induced displacement damage in HEMTs in both ON and OFF states by irradiating with 2.8 MeV Au 4+ ion to fluence levels ranging from 1.72 × 10 10 to 3.745 × 10 13 ions cm −2 , or 0.001–2 displacement per atom (dpa). Electrical measurement is done in situ , and high-resolution transmission electron microscopy (HRTEM), energy dispersive x-ray (EDX), geometrical phase analysis (GPA), and micro-Raman are performed on the highest fluence of Au 4+ irradiated devices. The selected heavy ion irradiation causes cascade damage in the passivation, AlGaN, and GaN layers and at all associated interfaces. After just 0.1 dpa, the current density in the ON-mode device deteriorates by two orders of magnitude, whereas the OFF-mode device totally ceases to operate. Moreover, six orders of magnitude increase in leakage current and loss of gate control over the 2-dimensional electron gas channel are observed. GPA and Raman analysis reveal strain relaxation after a 2 dpa damage level in devices. Significant defects and intermixing of atoms near AlGaN/GaN interfaces and GaN layer are found from HRTEM and EDX analyses, which can substantially alter device characteristics and result in complete failure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of electrical field on the susceptibility of gallium nitride transistors to proton irradiation

Radiation susceptibility of electronic devices is commonly studied as a function of radiation energetics and device physics. Often overlooked is the presence or magnitude of the electrical field, which we hypothesize to play an influential role in low energy radiation. Accordingly, we present a comprehensive study of low-energy proton irradiation on gallium nitride high electron mobility transistors (HEMTs), turning the transistor ON or OFF during irradiation. Commercially available GaN HEMTs were exposed to 300 keV proton irradiation at fluences varying from 3.76 × 10 12 to 3.76 × 10 14 cm 2 , and the electrical performance was evaluated in terms of forward saturation current, transconductance, and threshold voltage. The results demonstrate that the presence of an electrical field makes it more susceptible to proton irradiation. The decrease of 12.4% in forward saturation and 19% in transconductance at the lowest fluence in ON mode suggests that both carrier density and mobility are reduced after irradiation. Additionally, a positive shift in threshold voltage (0.32 V and 0.09 V in ON and OFF mode, respectively) indicates the generation of acceptor-like traps due to proton bombardment. high-resolution transmission electron microscopy and energy dispersive x-ray spectroscopy analysis reveal significant defects introduction and atom intermixing near AlGaN/GaN interfaces and within the GaN layer after the highest irradiation dose employed in this study. According to in-situ Raman spectroscopy, defects caused by irradiation can lead to a rise in self-heating and a considerable increase in (∼750 times) thermoelastic stress in the GaN layer during device operation. The findings indicate device engineering or electrical biasing protocol must be employed to compensate for radiation-induced defects formed during proton irradiation to improve device durability and reliability.

gallium nitride↗

Many-isocenter optimization for robotic radiotherapy

Despite significant dosimetric gains, clinical implementation of the 4π non-coplanar radiotherapy on the widely available C-arm gantry system is hindered by limited clearance, and the need to perform complex coordinated gantry and couch motion. A robotic radiotherapy platform would be conducive to such treatment but a new conflict between field size and MLC modulation resolution needs to be managed for versatile applications. This study investigates the dosimetry and delivery efficiency of purposefully creating many isocenters to achieve simultaneously high MLC modulation resolution and large tumor coverage. An integrated optimization framework was proposed for simultaneous beam orientation optimization (BOO), isocenter selection, and fluence map optimization (FMO). The framework includes a least-square dose fidelity objective, a total variation term for regularizing the fluence smoothness, and a group sparsity term for beam selection. A minimal number of isocenters were identified for efficient target coverage. Colliding beams excluded, high-resolution small-field 4π intensity-modulated radiotherapy (IMRT) treatment plans with 50 cm source-to-isocenter distance (SID-50) on 10 Head and Neck (H&N) cancer patients were compared with low-resolution large-field plans with 100 cm SID (SID-100). With the same or better target coverage, the average reduction of [Dmean, Dmax] of 20-beam SID-50 plans from 20-beam SID-100 plans were [2.09 Gy, 1.19 Gy] for organs at risk (OARs) overall, [3.05 Gy, 0.04 Gy] for parotid gland, [3.62 Gy, 5.19 Gy] for larynx, and [3.27 Gy, 1.10 Gy] for mandible. R50 and integral dose were reduced by 5.3% and 9.6%, respectively. Wilcoxon signed-rank test showed significant difference (p < 0.05) in planning target volume (PTV) homogeneity, PTV Dmax, R50, Integral dose, and OAR Dmean and Dmax. The estimated delivery time of 20-beam [SID-50, SID-100] plans were [19, 18] min and [14, 9] min, assuming 5 fractions and 30 fractions, respectively. Finally, with clinically acceptable delivery efficiency, many-isocenter optimization is dosimetrically desirable for treating large targets with high modulation resolution on the robotic platform.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Edge localized mode characteristics and divertor heat flux during stationary and transient phase for CFETR hybrid scenario

The study of edge localized mode (ELM) behavior, stationary heat flux and transient heat flux during the ELM crash phase is performed for a China Fusion Engineering Test Reactor (CFETR) 1 GW hybrid mode operation scenario ($R$ = 7.2 m, ${B_{\text{T}}}$ = 6.5 T, ${I_{\text{p}}}$ = 13.78 MA). Modeling and simulation start with a scenario obtained by multi-code integrated modeling on the one modeling framework for integrated tasks framework. Linear stability and nonlinear simulations of ELM dynamics are carried out using the BOUT++ six-field reduced magnetohydrodynamic module, which show a much smaller ELM energy loss (Δ ELM ~ 0.13%) compared to that of a Type-I ELM. Parametric analysis of the weak linear growth rate and small ELM energy loss characteristics shed light on physics corresponding to a grassy ELM regime for CFETR 1 GW hybrid scenario. The transient heat flux on the divertor target during this small ELM phase is investigated using BOUT++. Here we found that upstream radial transport in the scrape-off-layer (SOL) induced by small ELMs is weak, which keeps it in the drift-dominated region. However, the heat flux width is still broadened to ${\lambda _{\text{q}}}$ = 4.64 mm by the increase of separatrix temperature during ELM nonlinear evolution. The impact of transient peak heat load and ELM energy fluence on tungsten melting and net erosion rate of divertor target is evaluated for the first-time using physics-based transport that connects the pedestal with the SOL. Energy fluence caused by a single ELM pulse is below the tungsten melting limit, while tungsten erosion would exceed the material requirements. We conclude that external mitigation methods, such as divertor detachment and advanced divertor geometry are likely needed for the steady state operation of CFETR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The new ITER baseline, research plan and open R&D issues

A new baseline (NB) has been proposed by the ITER Project to ensure a robust achievement of the Projects’ goals, in view of past challenges including delays incurred due to the Covid-19 pandemic, technical challenges in completing first-of-a-kind components and in nuclear licensing. The NB includes modifications to the configuration of the ITER device and its ancillaries (e.g. change from beryllium to tungsten as first wall material, modification of the heating and current drive mix, etc.) as well as additional testing of components (e.g. toroidal field coils) or phased installation (start with inertially cooled first wall before later installation of the final actively water-cooled components) to minimise operational risks. In the NB, the ITER research plan (IRP) will be divided into three main phases: (a) start of research operation, with 40 MW of ECH and 10 MW of ICH, which will focus on the demonstration of 15 MA operation in L-mode, commissioning of all required systems, including disruption mitigation, and the demonstration of H-mode plasma operation in deuterium; (b) DT-1, with 60–67 MW of ECH, 33 MW of neutral beam injection (NBI) and 10–20 MW of ICH, which will demonstrate robust operation in high confinement H-mode plasmas in DT up to Q ⩾ 10 and for burn durations of 300–500 s within an accumulated neutron fluence of ∼1% of the ITER machine’s lifetime total, and; (c) DT-2, with up to 67 MW of ECH, up to 49.5 MW of NBI and up to 20 MW of ICH, with the ITER tokamak and ancillaries in their final configuration to demonstrate routine operation in DT plasmas at high Q and the Q ⩾ 5 long-pulse and steady-state scenarios to the final neutron fluence and to perform R&D on nuclear fusion reactor issues. The logic, physics basis, modelling and experimental evaluations carried out to support the NB and the associated IRP are described. These include the impact of the tungsten wall on plasma scenarios and associated risk mitigation measures, as well as the optimisation of the tokamak components and ancillaries to minimise Project risks. Open R&D issues related to these evaluations and mitigation measures are also described together with experimental, modelling and validation activities required to address them.

ITER↗

WEST full tungsten operation with an ITER grade divertor

The mission of WEST (tungsten-W Environment in Steady-state Tokamak) is to explore long pulse operation in a full tungsten (W) environment for preparing next-step fusion devices (ITER and DEMO) with a focus on testing the ITER actively cooled W divertor in tokamak conditions. Following the successful completion of phase 1 (2016-2021), phase 2 started in December 2022 with the lower divertor made entirely of actively cooled ITER-grade tungsten mono-blocks. A boronization prior the first plasma attempt allowed for a smooth startup with the new divertor. Despite the reduced operating window due to tungsten, rapid progress has been made in long pulse operation, resulting in discharges with a pulse length of 100 s and an injected energy of around 300 MJ per discharge. Plasma startup studies were carried out with equatorial boron nitride limiters to compare them with tungsten limiters, while Ion Cyclotron Resonance Heating assisted startup was attempted. High fluence operation in attached regime, which was the main thrust of the first campaigns, already showed the progressive build up of deposits and appearance of dust, impacting the plasma operation as the plasma fluence increased. In total, the cumulated injected energy during the first campaigns reached 43 GJ and the cumulated plasma time exceeded 5 h. Demonstration of controlled X-Point Radiator regime is also reported, opening a promising route for investigating plasma exhaust and plasma-wall interaction issues in more detached regime. This paper summarises the lessons learned from the manufacturing and the first operation of the ITER-grade divertor, describing the progress achieved in optimising operation in a full W environment with a focus on long pulse operation and plasma wall interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents

Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and physics analysis. This paper presents simulations and measurements of the leakage current in the ATLAS pixel detector and semiconductor tracker as a function of location in the detector and time, using data collected in Run 1 (2010-2012) and Run 2 (2015-2018) of the Large Hadron Collider. The extracted fluence shows a much stronger |z|-dependence in the innermost layers than is seen in simulation. Furthermore, the overall fluence on the second innermost layer is significantly higher than in simulation, with better agreement in layers at higher radii. These measurements are important for validating the simulation models and can be used in part to justify safety factors for future detector designs and interventions.

47 OTHER INSTRUMENTATION↗

Selection of the silicon sensor thickness for the Phase-2 upgrade of the CMS Outer Tracker

During the operation of the CMS experiment at the High-Luminosity LHC the silicon sensors of the Phase-2 Outer Tracker will be exposed to radiation levels that could potentially deteriorate their performance. Previous studies had determined that planar float zone silicon with n-doped strips on a p-doped substrate was preferred over p-doped strips on an n-doped substrate. The last step in evaluating the optimal design for the mass production of about 200 m$^{2}$ of silicon sensors was to compare sensors of baseline thickness (about 300 μm) to thinned sensors (about 240 μm), which promised several benefits at high radiation levels because of the higher electric fields at the same bias voltage. This study provides a direct comparison of these two thicknesses in terms of sensor characteristics as well as charge collection and hit efficiency for fluences up to 1.5 × 10$^{15}$ n$_{eq}$/cm$^{2}$. The measurement results demonstrate that sensors with about 300 μm thickness will ensure excellent tracking performance even at the highest considered fluence levels expected for the Phase-2 Outer Tracker.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of planar silicon pixel sensors with the RD53A readout chip for the Phase-2 Upgrade of the CMS Inner Tracker

The Large Hadron Collider at CERN will undergo an upgrade inorder to increase its luminosity to7.5 × 10$^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosityduring this High-Luminosity running phase, starting around 2029,means a higher rate of proton-proton interactions, hence a largerionizing dose and particle fluence for the detectors. The currenttracking system of the CMS experiment will be fully replaced inorder to cope with the new operating conditions. Prototype planarpixel sensors for the CMS Inner Tracker with square50 μm × 50 μm and rectangular100 μm × 25 μm pixels read out by theRD53A chip were characterized in the lab and at the DESY-II testbeamfacility in order to identify designs that meet the requirements ofCMS during the High-Luminosity running phase. A spatial resolutionof approximately 3.4 μm (2 μm) is obtained using themodules with 50 μm × 50 μm(100 μm × 25 μm) pixels at the optimalangle of incidence before irradiation. After irradiation to a 1 MeVneutron equivalent fluence ofΦ$_{eq}$ = 5.3 × 10$^{15}$ cm$^{-2}$, a resolution of9.4 μm is achieved at a bias voltage of 800 V using a modulewith 50 μm × 50 μm pixel size. All modulesretain a hit efficiency in excess of 99% after irradiation tofluences up to 2.1 × 10$^{16}$ cm$^{-2}$. Further studies ofthe electrical properties of the modules, especially crosstalk, arealso presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector

Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the start of LHC Run 2 in 2015. 3D pixel sensors are expected to exhibit more tolerance to radiation damage and are the technology of choice for the innermost layer in the ATLAS tracker upgrade for the HL-LHC programme. While the LHC has delivered an integrated luminosity of ≃ 235 fb -1 since the start of Run 2, the 3D sensors have received a non-ionising energy deposition corresponding to a fluence of ≃ 8.5 × 10 14 1 MeV neutron-equivalent cm -2 averaged over the sensor area. This paper presents results of measurements of the 3D pixel sensors' response during Run 2 and the first two years of Run 3, with predictions of its evolution until the end of Run 3 in 2025. Data are compared with radiation damage simulations, based on detailed maps of the electric field in the Si substrate, at various fluence levels and bias voltage values. These results illustrate the potential of 3D technology for pixel applications in high-radiation

47 OTHER INSTRUMENTATION↗

Resilience of High-Efficiency CdSeTe:As and CdSeTe:Cu Solar Cells to Proton Irradiation

Power generation in space is currently dominated by expensive III-V multi-junction photovoltaic (PV) devices and cheap crystalline silicon (c-Si) PV devices. Both of these technologies degrade rapidly in proton-radiation-rich space environments, such as the Van Allen belt. The present study of cadmium selenide telluride- (CdSeTe-) based PV devices exposed to 150-to-1500 keV proton irradiation with fluences up to 9 x 1013 cm-2 reveal a more radiation-hard alternative to III-V and c-Si PV technologies. We report on measurement and analysis of current density vs voltage (JV), external quantum efficiency (EQE), external radiative efficiency, and capacitance vs voltage (CV) characteristics. JV characteristics of As-doped CdSeTe devices show 80% remaining power conversion efficiency (PCE) relative to unexposed controls when exposed to 650 keV protons at a fluence of 1012 cm-2. Under these same irradiation conditions, Cu-doped CdSeTe devices demonstrate an even better 95% PCE retention compared with unirradiated control devices. Evidence of radiation-induced absorber p-type doping compensation is observed in the glass-side EQE at 0 V and CV characteristics of most of the irradiated CdSeTe:As devices, but clear compensation is evident only for the most heavily irradiated CdSeTe:Cu devices. Elevated blue-green photocurrent in the film-side 0 V EQE suggests a buried junction in the most heavily irradiated CdSeTe:As devices. Although CdSeTe:Cu devices are the more resilient of the CdSeTe structures, both CdSeTe-based technologies are radiation-hard when compared to c-Si and III-V multi-junction PV.

14 SOLAR ENERGY↗

Establishing accretion flares from supermassive black holes as a source of high-energy neutrinos

ABSTRACT The origin of cosmic high-energy neutrinos remains largely unexplained. For high-energy neutrino alerts from IceCube, a coincidence with time-variable emission has been seen for three different types of accreting black holes: (1) a gamma-ray flare from a blazar (TXS 0506+056), (2) an optical transient following a stellar tidal disruption event (TDE; AT2019dsg), and (3) an optical outburst from an active galactic nucleus (AGN; AT2019fdr). For the latter two sources, infrared follow-up observations revealed a powerful reverberation signal due to dust heated by the flare. This discovery motivates a systematic study of neutrino emission from all supermassive black hole with similar dust echoes. Because dust reprocessing is agnostic to the origin of the outburst, our work unifies TDEs and high-amplitude flares from AGN into a population that we dub accretion flares. Besides the two known events, we uncover a third flare that is coincident with a PeV-scale neutrino (AT2019aalc). Based solely on the optical and infrared properties, we estimate a significance of 3.6σ for this association of high-energy neutrinos with three accretion flares. Our results imply that at least ∼10 per cent of the IceCube high-energy neutrino alerts could be due to accretion flares. This is surprising because the sum of the fluence of these flares is at least three orders of magnitude lower compared to the total fluence of normal AGN. It thus appears that the efficiency of high-energy neutrino production in accretion flares is increased compared to non-flaring AGN. We speculate that this can be explained by the high Eddington ratio of the flares.

Astronomy & Astrophysics↗

Contemporaneous optical-radio observations of a fast radio burst in a close galaxy pair

ABSTRACT We present the MeerKAT discovery and MeerLICHT contemporaneous optical observations of the fast radio burst (FRB) 20230808F, which was found to have a dispersion measure of $\mathrm{DM}=653.2\pm 0.4\mathrm{\, pc\, cm^{-3}}$. FRB 20230808F has a scattering time-scale $\tau _{s}=3.1\pm 0.1\, \mathrm{ms}$ at 1563.6 MHz, a rotation measure $\mathrm{RM}=169.4\pm 0.2\, \mathrm{rad\, m^{-2}}$, and a radio fluence $F_{\mathrm{radio}}=1.72\pm 0.01\, \mathrm{Jy\, ms}$. We find no optical counterpart in the time immediately after the FRB, nor in the 3 months after the FRB during which we continued to monitor the field of the FRB. We set an optical upper flux limit in MeerLICHT’s q-band of $11.7\, \mathrm{\mu Jy}$ for a 60 s exposure which started ${\sim}3.4$ s after the burst, which corresponds to an optical fluence, $F_{\mathrm{opt}}$, of $0.039\, \mathrm{Jy\, ms}$ on a time-scale of ${\sim}3.4$ s. We obtain an estimate for the $q-$band luminosity limit of $vL_{v}\sim 1.3\times 10^{43}\, \mathrm{erg\, s^{-1}}$. We localize the burst to a close galaxy pair at a redshift of $z_{\mathrm{spec}}=0.3472\pm 0.0002$. Our time delay of ${\sim}3.4$ s between the FRB arrival time and the start of our optical exposure is the shortest ever for an as yet non-repeating FRB, and hence the closest to simultaneous optical follow-up that exists for such an FRB.

Hanmer, K. Y. (ORCID:0000000234757752)↗