Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

High Power Targetry R&D and support for future generation accelerator

A high-power target system is a key beam element to complete future High Energy Physics (HEP) experiments. The target endures high power pulsed beam, leading to high cycle thermal stresses/pressures and thermal shocks. The increased beam power will also create significant challenges such as corrosion and radiation damage that can cause harmful effects on the material and degrade their mechanical and thermal properties during irradiation. This can eventually lead to the failure of the material and drastically reduce the lifetime of targets and beam intercepting devices. Designing a reliable target is already a challenge for MW class facilities today and has led several major accelerator facilities to operate at lower power due to target concerns. With present plans to increase beam power for next generation accelerator facilities in the next decade and the multi-year time-scale to acquire the knowledge on material behavior under such extreme environment, timely R&D of robust high-power targets is critical to fully secure the physics benefits of ambitious accelerator power upgrades. The next generation of high-power targets for future accelerators will use more complex geometries, novel materials, and new concepts allowing better high heat flux cooling methods. Advanced numerical simulations need to be developed to satisfy the physical design requirements of reliable beam-intercepting devices. In parallel, radiation hardened beam instrumentation irradiation methods for high-power targets must be further developed. Additional irradiation facilities are needed since only a few facilities worldwide offer beams for target testing, and the beam provided may not be appropriate for the specific facility or project. Thus, a comprehensive research and development program must be implemented to address the challenges that multi-MW targets face.

Pellemoine, F.↗

Fabricating Graphene Oxide/h-BN Metal Insulator Semiconductor Diodes by Nanosecond Laser Irradiation

To employ graphene’s rapid conduction in 2D devices, a heterostructure with a broad bandgap dielectric that is free of traps is required. Within this paradigm, h-BN is a good candidate because of its graphene-like structure and ultrawide bandgap. We show how to make such a heterostructure by irradiating alternating layers of a-C and a-BN film with a nanosecond excimer laser, melting and zone-refining constituent layers in the process. With Raman spectroscopy and ToF-SIMS analyses, we demonstrate this localized zone-refining into phase-pure h-BN and rGO films with distinct Raman vibrational modes and SIMS profile flattening after laser irradiation. Furthermore, in comparing laser-irradiated rGO-Si MS and rGO/h-BN/Si MIS diodes, the MIS diodes exhibit an increased turn-on voltage (4.4 V) and low leakage current. The MIS diode I-V characteristics reveal direct tunneling conduction under low bias and Fowler-Nordheim tunneling in the high-voltage regime, turning the MIS diode ON with improved rectification and current flow. This study sheds light on the nonequilibrium approaches to engineering h-BN and graphene heterostructures for ultrathin field effect transistor device development.

2D materials↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MO-FG-CAMPUS-JeP1-03: Luminescence Imaging of Water During Proton Beam Irradiation for Range Estimation

Purpose: Since proton therapy has the ability to selectively deliver a dose to a target tumor, the dose distribution should be accurately measured. A precise and efficient method to evaluate the dose distribution is desired. We found that luminescence was emitted from water during proton irradiation and thought this phenomenon could be used for estimating the dose distribution. Methods: For this purpose, we placed water phantoms set on a table with a spot-scanning proton-therapy system, and luminescence images of these phantoms were measured with a high-sensitivity cooled charge coupled device (CCD) camera during proton-beam irradiation. We also conducted the imaging of phantoms of pure-water, fluorescein solution and acrylic block. We made three dimensional images from the projection data. Results: The luminescence images of water phantoms during the proton-beam irradiations showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. The image of the pure-water phantom also showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had 14.5% shorter proton range than that of water; the proton range in the acrylic phantom was relatively matched with the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 sec. Three dimensional images were successfully obtained which have more quantitative information. Conclusion: Luminescence imaging during proton-beam irradiation has the potential to be a new method for range estimations in proton therapy.

60 APPLIED LIFE SCIENCES↗

Measurement of Fission Gas Release from Irradiated Fuel During Temperature Transients (Progress Report)

A device for real-time fuel heating observations and collection of fission gas release data is being developed to study nuclear fuel behavior during a temperature transient. The proposed system incorporates high heating and cooling rates, a digital violet laser microscope, mass spectrometry, and gamma ray spectrometry. By placing the system in a hot cell or in a hot cell–like enclosure, the capability could support study of a range of samples, including low and high burnup nuclear fuels. This report documents a conceptional design that incorporates a commercially available system that can be modified to achieve the desired specifications and proposed modifications. This report has been submitted in fulfillment of milestone M3FT-19OR020204082 titled, “Progress Report on Measurement of Fission Gas Release from Irradiated Fuel during Temperature Transient,” for the US Department of Energy Office of Nuclear Energy, Advanced Fuel Campaign of the Fuel Cycle R&D program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proton radiation resilience of CdSeTe photovoltaics: High predicted end-of-life performance for space applications

Two types of cadmium selenide telluride (CdSeTe) photovoltaic devices have been exposed to high-energy (150–1500 keV) protons with fluences ranging from 1 × 10 11 to 9 × 10 13 cm −2 . Pre- and post-irradiation current density vs voltage characteristic data were collected and analyzed. Arsenic-doped CdSeTe devices retained 80% of the power conversion efficiency (PCE) relative to control devices after exposure to 10 12 cm −2 650 keV protons, while copper-doped CdSeTe devices retained about 95% of the control PCE under the same irradiation condition. Displacement damage dose analysis coupled with simulations for duration-dependent performance in a medium Earth orbit space mission revealed superior PCE remaining factors, indicating greater resilience to proton bombardment than state-of-the-art multijunction III-V based space photovoltaic technologies.

CdTe solar cells↗

Luminescence imaging of water during proton-beam irradiation for range estimation

Purpose: Proton therapy has the ability to selectively deliver a dose to the target tumor, so the dose distribution should be accurately measured by a precise and efficient method. The authors found that luminescence was emitted from water during proton irradiation and conjectured that this phenomenon could be used for estimating the dose distribution. Methods: To achieve more accurate dose distribution, the authors set water phantoms on a table with a spot scanning proton therapy system and measured the luminescence images of these phantoms with a high-sensitivity, cooled charge coupled device camera during proton-beam irradiation. The authors imaged the phantoms of pure water, fluorescein solution, and an acrylic block. Results: The luminescence images of water phantoms taken during proton-beam irradiation showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. Furthermore, the image of the pure-water phantom showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of the fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had a 14.5% shorter proton range than that of water; the proton range in the acrylic phantom generally matched the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 s. Conclusions: Luminescence imaging during proton-beam irradiation is promising as an effective method for range estimation in proton therapy.

60 APPLIED LIFE SCIENCES↗

An Efficient Copper-Based Redox Shuttle Bearing a Hexadentate Polypyridyl Ligand for DSCs under Low-Light Conditions

A Cu complex featuring a hexadentate ligand was synthesized and evaluated as a redox shuttle in dye-sensitized solar cell (DSC) devices, which exhibited excellent performance under low-light conditions. Cu-based redox shuttles (RSs) have been shown to perform remarkably well under low-light conditions; however, most of the known Cu-based RSs employ bidentate pyridyl ligands and often require bulky flanking groups adjacent to the nitrogen donors of these ligands to prevent distortion and binding of exogenous Lewis bases such as 4- tert -butylpyridine (TBP) that are added to enhance cell performance. Without the bulky substituents, the bidentate ligands are susceptible to ligand exchange with TBP. In this context, we have developed a Cu-based RS with a preorganized multidentate ligand designed to facilitate efficient electron transfer kinetics and high stability via the chelate effect. The Cu system, [Cu(bpyPY4)] 2+/+ , reported here is supported by the hexadentate polypyridyl ligand bpyPY4 (6,6'-bis(1,1-di(pyridine-2-yl)ethyl)-2,2'-bipyridine) and examined as a RS in DSCs. From X-ray crystallography and variable-temperature 1 H NMR studies, bpyPY4 provides a dynamic coordination environment around the metal center. Cyclic voltammetry and UV–visible and NMR spectroscopy indicate that noncoordinated pyridyl donors block binding of TBP to copper. DSC devices using [Cu(bpyPY4)] 2+/+ as the redox electrolyte gave a power conversion efficiency (PCE) value of 4.9% under 1 sun illumination (100 mW/cm 2 ). Strikingly, the device performance increased to 11.11% when irradiated with 2400 lux (0.5 mW/cm 2 ) via a fluorescent lamp light source and improved further to 15.2% PCE at 13500 lux (2.10 mW/cm 2 ). In conclusion, the Cu redox shuttle is an intriguing candidate for implementation with narrow band gap sensitizers with low oxidation potentials, which are important for high photocurrent DSC devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Ion Irradiation on Amorphous and Crystalline Ge–Se and Their Application as Phase Change Temperature Sensor

Research on phase change materials is predominantly focused on their application as memory devices or for temperature control which requires low phase change temperature. The Ge–Se binary chalcogenide glass system with its wide glass-forming region is a potential candidate for high-temperature and high-radiation phase change applications. In this study, the concept of employing Ge x Se 100– x glasses to monitor high temperature (450–528 °C) using the phase change effect, is reported. Materials selection, device structure, and performance of prototype sensors are analyzed. In addition, the effect of heavy ion irradiation by Xe ions with energies of 200, 600, and 1000 keV (fluence ≈10 14 cm –2 ) on the Ge x Se 100– x ( x = 30, 33, 40) thin films and phase change devices is studied. The irradiation effect on the amorphous and crystalline structure of the thin films is evaluated by Raman spectroscopy and X-ray diffraction (XRD). Although the changes in the structural units of amorphous films are negligible, in crystalline films orthorhombic-GeSe 2 crystals are found to be most affected by irradiation and a new phase, orthorhombic GeSe is found in the thin films after irradiation. The performance of a sensor with an active film of Ge 40 Se 60 is also shown as an example.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of proton irradiation energy on AlGaN/GaN metal-oxide semiconductor high electron mobility transistors

The effects of proton irradiation energy on dc characteristics of AlGaN/GaN metal-oxide semiconductor high electron mobility transistors (MOSHEMTs) using Al 2 O 3 as the gate dielectric were studied. Al 2 O 3 /AlGaN/GaN MOSHEMTs were irradiated with a fixed proton dose of 5 × 10 15 cm -2 at different energies of 5, 10, or 15 MeV. More degradation of the device dc characteristics was observed for lower irradiation energy due to the larger amount of nonionizing energy loss in the active region of the MOSHEMTs under these conditions. The reductions in saturation current were 95.3%, 68.3%, and 59.8% and reductions in maximum transconductance were 88%, 54.4%, and 40.7% after 5, 10, and 15 MeV proton irradiation, respectively. Both forward and reverse gate leakage current were reduced more than one order of magnitude after irradiation. The carrier removal rates for the irradiation energies employed in this study were in the range of 127–289 cm -1 . These are similar to the values reported for conventional metal-gate high-electron mobility transistors under the same conditions and show that the gate dielectric does not affect the response to proton irradiation for these energies.

36 MATERIALS SCIENCE↗

Detection of high energy ionizing radiation using deeply depleted graphene–oxide–semiconductor junctions

Graphene’s linear band structure and two-dimensional density of states provide an implicit advantage for sensing charge. Here, these advantages are leveraged in a deeply depleted graphene–oxide–semiconductor (D2GOS) junction detector architecture to sense carriers created by ionizing radiation. Specifically, the room temperature response of a silicon-based D2GOS junction is analyzed during irradiation with 20 MeV Si4+ ions. Detection was demonstrated for doses ranging from 12 to 1200 ions with device functionality maintained with no substantive degradation. To understand the device response, D2GOS pixels were characterized post-irradiation via a combination of electrical characterization, Raman spectroscopy, and photocurrent mapping. This combined characterization methodology underscores the lack of discernible damage caused by irradiation to the graphene while highlighting the nature of interactions between the incident ions and the silicon absorber.

Ruiz, Isaac↗

Evaluation of Exposure From a Low Energy X-Ray Device Using Thermoluminescent Dosimeters

The exposure from an electron beam welding device was evaluated using thermoluminescent dosimeters (TLDs). The device generated low energy X-rays which the current dose equivalent conversion algorithm was not designed to evaluate making it necessary to obtain additional information relating to TLD operation at the photon energies encountered with the device. This was accomplished by performing irradiations at the National Institute of Standards and Technology (NIST) using low energy X-ray techniques. The resulting data was used to determine TLD badge response for low energy X-rays and to establish the relationship between TLD element response and the dose equivalent at specific depths in tissue for these photon energies. The new energy/dose equivalent calibration data was used to calculate the shallow and eye dose equivalent of badges exposed to the device.

Edwards, David L.↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

SU-G-BRB-09: Kompeito-Shot: Development of a Novel Verification System for 3D Beam Alignment Including the Sag of Gantry Head

Purpose: High accuracy of beam axis is required for high-precision radiation therapy. It is impossible to quantitatively and directly evaluate the sagging effect of the gantry head using current methods (star-shot and Winston-Lutz tests) when the gantry head sags under the weight of MLC and X-Y jaws. We introduce a novel method “Kompeito-shot (3D star-shot)” for the verification of 3D beam alignment (3D isocentricity). This method enables direct measurement of the sagging effect. We developed the system and examined the concept of this system. Methods: The system composed of a plastic scintillator (PS), a truncated cone-shaped mirror, a plane mirror and a CCD camera. Two types of PS were compared. One consisted of a column PS (Co system), the other consisted of a column PS inserted into a barrel PS with shading film in between (Co-Ba system). The system was irradiated with a 6-MV photon beam and the scintillation light was measured using the CCD camera through the mirror system. The gantry angle was set from 270 to 300 degrees to mimic the sagging of the gantry head for evaluating the accuracy of the system. The distance between a center of PS and entrance / exit points were calculated to analyze the gantry angle. And, the calculated gantry angle and the irradiated gantry angle were compared. Results: We compared the measured image of Co system and that of Co-Ba system. Entrance and exit areas were visualized clearly. The histogram showing the difference between the calculated gantry angle and the irradiated gantry angle was fitted with a Gaussian function. Mean and standard deviation of Co-Ba system were smaller than that of Co system by one order of magnitude. Conclusion: We developed the Kompeito-shot system and evaluated the accuracy of the system. The basic concept works for the verification of 3D isocentricity.

60 APPLIED LIFE SCIENCES↗

Digging deeper: Buried layers and interfaces studied by modified total electron yield and soft x-ray absorption spectroscopy

We report on the soft x-ray absorption spectroscopy investigation of thin film capacitors using a modified total electron yield detection mode. This mode utilizes two ammeters instead of one as commonly employed in the classical total electron yield scheme to measure photocurrents of devices under soft x-ray irradiation. The advantage of this configuration over the surface sensitive classical total electron yield mode is that it can provide information from buried layers and interfaces up to a thickness equal to the penetration depth of soft x-rays. The method can be easily adapted to existing synchrotron end stations. We investigate dielectric capacitors with dissimilar electrodes to assess the feasibility of the modified total electron yield method. Furthermore, in operando soft x-ray absorption spectroscopy measurements are performed on ferroelectric capacitors under bias and using two ammeters. The experimental results are discussed in terms of the external and internal photoemission processes and their distribution in thin film capacitors under an external bias condition. The proposed detection method opens the way to perform electronic and chemical state analyses of the buried interfaces and layers in various devices like multiferroic tunnel junctions, memristive devices, etc., during operation under an applied bias.

Kröger, E.↗

Hardening of MJS77 spacecraft against the Jupiter radiation belts

Results of the device characterization program to identify components of the Mariner Jupiter/Saturn spacecraft in need of radiation hardening to meet a total dose requirement of 5 trillion e/sq cm are presented. The parts to be tested, including bipolar transistors, JFETs, SCRs, CMOS devices, linear integrated circuits, Zener diodes and other radiation-sensitive parts, were identified by a worst case circuit analysis of the 20 major subsystems. The test samples were exposed to several levels of irradiation from a Dynamitron electron accelerator capable of producing a steady stream of electrons at energies up to 2.5 eV. The electrical parameters of the devices were measured immediately following irradiation to prevent annealing. CMOS devices and linear devices showed the most severe degradation in a moderate radiation environment, and significant degradation was produced at low current in bipolar transistors. Three methods used for screening a number of devices determined by circuit and shielding analyses to be unacceptable radiation-sensitive are described: diffusion and metallization lot screening; wafer lot screening; and irradiation-anneal screening.

W E Price↗

Single-Event Latchup Testing of the Micrel MIC4424 Dual Power MOSFET Driver

We conducted 47 exposures of four different MIC4424 devices and did not observe any SEL or high-current events. This included worst-case conditions with a LET of 81 MeV-sq cm/mg, applied voltage of 18.5 V, a case temperature greater than 120 C, and a final fluence of 1x10(exp 7)/sq cm. We also monitored both the outputs for the presence of SETs. While the period of the 1 MHz square wave was slightly altered in some cases, no pulses were added or deleted. 1. Purpose: The purpose of this testing is to characterize the BiCMOS/DMOS Micrel MIC4424 dual, non-inverting MOSFET driver for single-event latchup (SEL) susceptibility. These data will be used for flight lot evaluation purposes. 2. Devices Tested: The MIC4423/4424/4425 family are highly reliable BiCMOS/DMOS buffer/driver MOSFET drivers. They are higher output current versions of the MIC4426/4427/4428. They can survive up to 5V of noise spiking, of either polarity, on the ground pin. They can accept, without either damage or logic upset, up to half an amp of reverse current (either polarity) forced back into their outputs. Primarily intended for driving power MOSFETs, the MIC4423/4424/4425 drivers are suitable for driving other loads (capacitive, resistive, or inductive) which require low-impedance, high peak currents, and fast switching times. Heavily loaded clock lines, coaxial cables, or piezoelectric transducers are some examples. The only known limitation on loading is that total power dissipated in the driver must be kept within the maximum power dissipation limits of the package. Five (5) parts were provided for SEL testing. We prepared four parts for irradiation and reserved one piece as an un-irradiated control. More information about the devices can be found in Table 1. The parts were prepared for testing by removing the lid from the CDIP package to expose the target die. The parts were then soldered to small copper circuit adapter boards for easy handling. These parts are fabricated in a bulk BiCMOS/DMOS technology. Since we do not know the number of overlayers used in the fabrication processes, linear energy transfer calculations are determined based on the top-surface incident ion species and kinetic energy.

Power MOSFET↗