Hypersonic Boundary-Layer Trip Development for Hyper-X

Boundary layer trip devices for the Hper-X forebody have been experimentally examined in several wind tunnels. Five different trip configurations were compared in three hypersonic facilities, the LaRC 20-Inch Mach 6 Air Tunnel, the LaRC 31 -Inch Mach 10 Air Tunnel, and in the HYPULSE Reflected Shock Tunnel at GASL. Heat transfer distributions, utilizing the phosphor thermography and thin-film techniques, shock system details, and surface streamline patterns were measured on a 0.333-scale model of the Hyper-X forebody. Parametric variations include angles-of-attack of 0-deg, 2-deg, and 4-deg; Reynolds numbers based on model length of 1.2 to 15.4 million: and inlet cowl door simulated in both open and closed positions. Comparisons of transition due to discrete roughness elements have led to the selection of a trip configuration for the Hyper-X Mach 7 flight vehicle.

Berry, Scott A.↗

Forced Boundary-Layer Transition on X-43 (Hyper-X) in NASA LaRC 20-Inch Mach 6 Air Tunnel

Aeroheating and boundary layer transition characteristics for the X-43 (Hyper-X) configuration have been experimentally examined in the Langley 20-Inch Mach 6 Air Tunnel. Global surface heat transfer distributions, and surface streamline patterns were measured on a 0.333-scale model of the Hyper-X forebody. Parametric variations include angles-of-attack of 0-deg, 2-deg, and 4-deg; Reynolds numbers based on model length of 1.2 to 15.4 million; and inlet cowl door both open and closed. The effects of discrete roughness elements on the forebody boundary layer, which included variations in trip configuration and height, were investigated. This document is intended to serve as a release of preliminary data to the Hyper-X program; analysis is limited to observations of the experimental trends in order to expedite dissemination.

Berry, Scott A.↗

Forced Boundary-Layer Transition on X-43 (Hyper-X) in NASA LaRC 31-Inch Mach 10 Air Tunnel

Aeroheating and boundary layer transition characteristics for the X-43 (Hyper-X) configuration have been experimentally examined in the Langley 31-Inch Mach 10 Air Tunnel. Global surface heat transfer distributions, and surface streamline patterns were measured on a 0.333-scale model of the Hyper-X forebody. Parametric variations include angles-of-attack of 0-deg, 2-deg, 3-deg, and 4-deg; Reynolds numbers based on model length of 1.2 to 5.1 million; and inlet cowl door both open and closed. The effects of discrete roughness elements on the forebody boundary layer, which included variations in trip configuration and height, were investigated. This document is intended to serve as a release of preliminary data to the Hyper-X program; analysis is limited to observations of the experimental trends in order to expedite dissemination.

Berry, Scott A.↗

Folded Coplanar Waveguide Slot Antenna on Silicon Substrates With a Polyimide Interface Layer

A novel mm-wave Coplanar Waveguide (CPW) folded slot antenna is characterized on low-resistivity Si substrate (1 omega-cm) and a high resistivity Si substrate with a polyimide interface layer for the first time. The antenna resonates around 30 GHz with a return loss greater than 14.6 dB. Measured radiation patterns indicate the existence of a main lobe, but the radiation pattern is affected by a strong surface wave mode, which is greater in the high resistivity Si wafer.

Bacon, Andrew↗

A Comparison of Active and Passive Methods for Control of Hypersonic Boundary Layers on Airbreathing Configurations

Active and passive methods for control of hypersonic boundary layers have been experimentally examined in NASA Langley Research Center wind tunnels on a Hyper-X model. Several configurations for forcing transition using passive discrete roughness elements and active mass addition, or blowing, methods were compared in two hypersonic facilities, the 20-Inch Mach 6 Air and the 31-Inch Mach 10 Air tunnels. Heat transfer distributions, obtained via phosphor thermography, shock system details, and surface streamline patterns were measured on a 0.333-scale model of the Hyper-X forebody. The comparisons between the active and passive methods for boundary layer control were conducted at test conditions that nearly match the nominal Mach 7 flight trajectory of an angle-of-attack of 2-deg and length Reynolds number of 5.6 million. For the passive roughness examination, the primary parametric variation was a range of trip heights within the calculated boundary layer thickness for several trip concepts. The prior passive roughness study resulted in a swept ramp configuration being selected for the Mach 7 flight vehicle that was scaled to be roughly 0.6 of the calculated boundary layer thickness. For the active jet blowing study, the blowing manifold pressure was systematically varied for each configuration, while monitoring the mass flow, to determine the jet penetration height with schlieren and transition movement with the phosphor system for comparison to the passive results. All the blowing concepts tested were adequate for providing transition onset near the trip location with manifold stagnation pressures on the order of 40 times the model static pressure or higher.

Berry, Scott A.↗

Lunar and Planetary Science XXXV: Astrobiology

The presentations in this session are: 1. A Prototype Life Detection Chip 2. The Geology of Atlantis Basin, Mars, and Its Astrobiological Interest 3. Collecting Bacteria Together with Aerosols in the Martian Atmosphere by the FOELDIX Experimental Instrument Developed with a Nutrient Detector Pattern: Model Measurements of Effectivity 4. 2D and 3D X-ray Imaging of Microorganisms in Meteorites Using Complexity Analysis to Distinguish Field Images of Stromatoloids from Surrounding Rock Matrix in 3.45 Ga Strelley Pool Chert, Western Australia 4. Characterization of Two Isolates from Andean Lakes in Bolivia Short Time Scale Evolution of Microbiolites in Rapidly Receding Altiplanic Lakes: Learning How to Recognize Changing Signatures of Life 5. The Effect of Salts on Electrospray Ionization of Amino Acids in the Negative Mode 6. Determination of Aromatic Ring Number Using Multi-Channel Deep UV Native Fluorescence 7. Microbial D/H Fractionation in Extraterrestrial Materials: Application to Micrometeorites and Mars 8. Carbon Isotope Characteristics of Spring-fed Iron-precipitating Microbial Mats 9. Amino Acid Survival Under Ambient Martian Surface UV Lighting Extraction of Organic Molecules from Terrestrial Material: Quantitative Yields from Heat and Water Extractions 10. Laboratory Detection and Analysis of Organic Compounds in Rocks Using HPLC and XRD Methods 11. Thermal Decomposition of Siderite-Pyrite Assemblages: Implications for Sulfide Mineralogy in Martian Meteorite ALH84001 Carbonate Globules 12. Determination of the Three-Dimensional Morphology of ALH84001 and Biogenic MV-1 Magnetite: Comparison of Results from Electron Tomography and Classical Transmission Electron Microscopy 13. On the Possibility of a Crypto-Biotic Crust on Mars Based on Northern and Southern Ringed Polar Dune Spots 14. Comparative Planetology of the Terrestrial Inner Planets: Implications for Astrobiology 15. A Possible Europa Exobiology 16. A Possible Biogeochemical Model for Titan

Source record↗

Boundary Layer Control for Hypersonic Airbreathing Vehicles

Active and passive methods for tripping hypersonic boundary layers have been examined in NASA Langley Research Center wind tunnels using a Hyper-X model. This investigation assessed several concepts for forcing transition, including passive discrete roughness elements and active mass addition (or blowing), in the 20-Inch Mach 6 Air and the 31-Inch Mach 10 Air Tunnels. Heat transfer distributions obtained via phosphor thermography, shock system details, and surface streamline patterns were measured on a 0.333-scale model of the Hyper-X forebody. The comparisons between the active and passive methods for boundary layer control were conducted at test conditions that nearly match the Hyper-X nominal Mach 7 flight test-point of an angle-of-attack of 2-deg and length Reynolds number of 5.6 million. For passive roughness, the primary parametric variation was a range of trip heights within the calculated boundary layer thickness for several trip concepts. The passive roughness study resulted in a swept ramp configuration, scaled to be roughly 0.6 of the calculated boundary layer thickness, being selected for the Mach 7 flight vehicle. For the active blowing study, the manifold pressure was systematically varied (while monitoring the mass flow) for each configuration to determine the jet penetration height, with schlieren, and transition movement, with the phosphor system, for comparison to the passive results. All the blowing concepts tested, which included various rows of sonic orifices (holes), two- and three-dimensional slots, and random porosity, provided transition onset near the trip location with manifold stagnation pressures on the order of 40 times the model surface static pressure, which is adequate to ensure sonic jets. The present results indicate that the jet penetration height for blowing was roughly half the height required with passive roughness elements for an equivalent amount of transition movement.

Berry, Scott A.↗

VA/Q distribution during heavy exercise and recovery in humans: implications for pulmonary edema

Ventilation-perfusion (VA/Q) inequality has been shown to increase with exercise. Potential mechanisms for this increase include nonuniform pulmonary vasoconstriction, ventilatory time constant inequality, reduced large airway gas mixing, and development of interstitial pulmonary edema. We hypothesized that persistence of VA/Q mismatch after ventilation and cardiac output subside during recovery would be consistent with edema; however, rapid resolution would suggest mechanisms related to changes in ventilation and blood flow per se. Thirteen healthy males performed near-maximal cycle ergometry at an inspiratory PO2 of 91 Torr (because hypoxia accentuates VA/Q mismatch on exercise). Cardiorespiratory variables and inert gas elimination patterns were measured at rest, during exercise, and between 2 and 30 min of recovery. Two profiles of VA/Q distribution behavior emerged during heavy exercise: in group 1 an increase in VA/Q mismatch (log SDQ of 0.35 +/- 0.02 at rest and 0.44 +/- 0.02 at exercise; P less than 0.05, n = 7) and in group 2 no change in VA/Q mismatch (n = 6). There were no differences in anthropometric data, work rate, O2 uptake, or ventilation during heavy exercise between groups. Group 1 demonstrated significantly greater VA/Q inequality, lower vital capacity, and higher forced expiratory flow at 25-75% of forced vital capacity for the first 20 min during recovery than group 2. Cardiac index was higher in group 1 both during heavy exercise and 4 and 6 min postexercise. However, both ventilation and cardiac output returned toward baseline values more rapidly than did VA/Q relationships. Arterial pH was lower in group 1 during exercise and recovery. We conclude that greater VA/Q inequality in group 1 and its persistence during recovery are consistent with the hypothesis that edema occurs and contributes to the increase in VA/Q inequality during exercise. This is supported by observation of greater blood flows and acidosis and, presumably therefore, higher pulmonary vascular pressures in such subjects.

NASA Discipline Cardiopulmonary↗

Use of Raman Spectroscopy and Delta Volume Growth from Void Collapse to Assess Overwrap Stress Gradients Compromising the Reliability of Large Kevlar/Epoxy COPVs

Composite Overwrapped Pressure Vessels (COPVs) are frequently used for storing pressurized gases aboard spacecraft and aircraft when weight saving is desirable compared to all-metal versions. Failure mechanisms in fibrous COPVs and variability in lifetime can be very different from their metallic counterparts; in the former, catastrophic stress-rupture can occur with virtually no warning, whereas in latter, a leak before burst design philosophy can be implemented. Qualification and certification typically requires only one burst test on a production sample (possibly after several pressure cycles) and the vessel need only meet a design burst strength (the maximum operating pressure divided by a knockdown factor). Typically there is no requirement to assess variability in burst strength or lifetime, much less determine production and materials processing parameters important to control of such variability. Characterizing such variability and its source is crucial to models for calculating required reliability over a given lifetime (e.g. R = 0.9999 for 15 years). In this paper we present a case study of how lack of control of certain process parameters in COPV manufacturing can result in variations among vessels and between production runs that can greatly increase uncertainty and reduce reliability. The vessels considered are 40-inch ( NASA Glenn Research center, Cleveland, OH, 44135 29,500 in3 ) spherical COPVs with a 0.74 in. thick Kevlar49/epoxy overwrap and with a titanium liner of which 34 were originally produced. Two burst tests were eventually performed that unexpectedly differed by almost 5%, and were 10% lower than anticipated from burst tests on 26-inch sister vessels similar in every detail. A major observation from measurements made during proof testing (autofrettage) of the 40-inch vessels was that permanent volume growth from liner yielding varied by a factor of more than two (150 in3 to 360 in3 ), which suggests large differences in the residual stress gradient through their overwraps. This resulted in large uncertainty in true fiber stress ratio (fiber stress at operating pressure divided by fiber stress at burst) which governs lifetime. The vessels were originally designed with tight safety margins, so it became crucial to develop a non-destructive evaluation (NDE) technique to directly measure the overwrap residual stress state of each vessel, and to identify those vessels at highest risk of having poor reliability. This paper describes a Raman Spectroscopy technique for measuring certain patterns of fluctuation in fiber elastic strains over the outside vessel surface (where all but one wrap is exposed at certain locations) that are shown to directly correlate to increased fiber stress ratios and reduced reliability.

Kezirian, Michael T.↗

PVD Silicon Carbide as a Thin Film Packaging Technology for Antennas on LCP Substrates for Harsh Environments

This paper describes an effort to develop a thin film packaging technology for microfabricated planar antennas on polymeric substrates based on silicon carbide (SiC) films deposited by physical vapor deposition (PVD). The antennas are coplanar waveguide fed dual frequency folded slot antennas fabricated on liquid crystal polymer (LCP) substrates. The PVD SiC thin films were deposited directly onto the antennas by RF sputtering at room temperature at a chamber pressure of 30 mTorr and a power level of 300 W. The SiC film thickness is 450 nm. The return loss and radiation patterns were measured before and after the SiC-coated antennas were submerged into perchloric acid for 1 hour. No degradation in RF performance or physical integrity of the antenna was observed.

Scardelletti, Maximilian C.↗

NASA Tech Briefs, September 2004

Topics covered include: Brazing SiC/SiC Composites to Metals; Composite-Material Tanks with Chemically Resistant Liners; Thermally Conductive Metal-Tube/Carbon-Composite Joints; Improved BN Coatings on SiC Fibers in SiC Matrices; Iterative Demodulation and Decoding of Non-Square QAM; Measuring Radiation Patterns of Reconfigurable Patch Antennas on Wafers; Low-Cutoff, High-Pass Digital Filtering of Neural Signals; Further Improvement in 3DGRAPE; Ground Support Software for Spaceborne Instrumentation; MER SPICE Interface; Simulating Operation of a Planetary Rover; Analyzing Contents of a Computer Cache; Discrepancy Reporting Management System; Silicone-Rubber Microvalves Actuated by Paraffin; Hydraulic Apparatus for Mechanical Testing of Nuts; Heat Control via Torque Control in Friction Stir Welding; Manufacturing High-Quality Carbon Nanotubes at Lower Cost; Setup for Visual Observation of Carbon-Nanotube Arc Process; Solution Preserves Nucleic Acids in Body-Fluid Specimens; Oligodeoxynucleotide Probes for Detecting Intact Cells; Microwave-Spectral Signatures Would Reveal Concealed Objects; Digital Averaging Phasemeter for Heterodyne Interferometry; Optoelectronic Instrument Monitors pH in a Culture Medium; Imaging of gamma-Irradiated Regions of a Crystal; Photodiode-Based, Passive Ultraviolet Dosimeters; Discrete Wavelength-Locked External Cavity Laser; Flexible Shields for Protecting Spacecraft Against Debris; Part 2 of a Computational Study of a Drop-Laden Mixing Layer; Controllable Curved Mirrors Made from Single-Layer EAP Films; and Demonstration of a Pyrotechnic Bolt-Retractor System.

Source record↗

Global Roughness Texture of the Moon and Mars

Statistical measures of patterns (textures) in surface roughness are used to quantitatively differentiate regional geomorphic units on the Moon and Mars (e.g. cratered highlands, volcanic terrains and planar lowlands). The existence of vastly distinct crustal types on Mars and the Moon is well established [e.g. 1, 2, 3, & 4]. Here, a new methodology developed for differentiating terrestrial volcanic deposits using ~1 m resolution topography data [5], is tested on two global data sets where roughness pixels are much larger (1/4 of a degree).

Whelley, P. L.↗

Common-Mode Digital Holographic Microscope

A lens-less digital holographic microscope, a reflective digital holographic microscope, and a digital holographic microscope including a plurality of lenses. In one example, the digital holographic microscope includes a single mode fiber collimated light source which provides illumination for both the `science` and `reference` arms, a pair of microscope objectives located side-by side, and illuminated by the common beam, a relay lens whose center is between the two objectives, and a focal plane element where the interference pattern is measured.

Wallace, James K.↗

Evolution of bioconvective patterns in variable gravity

Measurements are reported of the evolution of bioconvective patterns in shallow, dense cultures of microorganisms subjected to varying gravity. Various statistical properties of this random, quasi-two-dimensional structure have been found: Aboav's law is obeyed, the average vertex angles follow predictions for regular polygons, and the area of a pattern varies linearly with its number of sides. As gravity varies between 1 g and 1.8 g, these statistical properties continue to hold despite a tripling of the number of polygons and a reduced average polygon dimension by a third. This work compares with experiments on soap foams, Langmuir monolayer foams, metal grains, and simulations.

Noever, David A.↗

Table of interplanar spacings for crystal-structure determinations by X-ray diffraction with molybdenum, copper, cobalt, iron, and chromium radiations

For a simple diffraction pattern, the time required to calculate interplanar distances from measurements of the pattern is not excessive. If more than a few lines are present, however, or if several patterns are to be studied, it is very advantageous to have available a table giving interplanar spacings directly in terms of the linear measurements made on the film of the lines appearing on the diffraction pattern. The preparation of the table given here was undertaken when the expansion of research activities involving X-ray diffraction techniques indicated that such a table would greatly decrease the time required to analyze diffraction patterns. The table was prepared for use with K alpha(sub 1) radiation from the following target materials: molybdenum, copper, cobalt, iron, and chromium.

METALS - STRUCTURES↗

Evaluation of a multi-point method for determining acoustic impedance

An investigation was conducted to explore potential improvements provided by a Multi-Point Method (MPM) over the Standing Wave Method (SWM) and Two-Microphone Method (TMM) for determining acoustic impedance. A wave propagation model was developed to model the standing wave pattern in an impedance tube. The acoustic impedance of a test specimen was calculated from a best fit of this standing wave pattern to pressure measurements obtained along the impedance tube centerline. Three measurement spacing distributions were examined: uniform, random, and selective. Calculated standing wave patterns match the point pressure measurement distributions with good agreement for a reflection factor magnitude range of 0.004 to 0.999. Comparisons of results using 2, 3, 6, and 18 measurement points showed that the most consistent results are obtained when using at least 6 evenly spaced pressure measurements per half-wavelength. Also, data were acquired with broadband noise added to the discrete frequency noise and impedances were calculated using the MPM and TMM algorithms. The results indicate that the MPM will be superior to the TMM in the presence of significant broadband noise levels associated with mean flow.

Jones, Michael G.↗

Dependence of the Element Patterns of HYDROSTAR on Mutual Coupling

HYDROSTAR is a hybrid synthesis radiometer, intended for spaceborne applications, which employs a real aperture (waveguide stick antenna) for resolution along track and employs aperture synthesis to obtain resolution across track. This L-band system is an extension of the successful aircraft prototype, the Electronically Steered Thinned Array Radiometer (ESTAR). A proof-of-concept, full size system was constructed (45 wavelength in the synthesis direction) and subjected to extensive antenna pattern and associated microwave component measurements in an outdoor antenna test facility. HYDROSTAR employs a thinned array of 16 elements each 5.8 inches long in the along track dimension and spanning 9.5 inches across track. Each element is a narrow-wall shunt slot array with 36 slots. The polarization is linear (along-track). In the across track dimension, the antennas are deployed in a minimum redundancy array which has 90 independent baselines spaced in integer multiples of half a wavelength. The closest spacings used are for the first three elements at each end, which are spaced by only one-half wavelength. This study was intended to assess how closely each of 16 stick element patterns compare with their nominal values (as an individual, isolated radiator), when installed in their intended composite thinned array configuration. Extensive pattern measurements of the 16 elements that constitute the HYDROSTAR antenna subsystem were conducted to observe their relative features along the synthesis plane. Data was also collected for the mutual coupling between pairs of selected antennas. All antenna patterns had features different from that of an isolated element indicating some level of interaction among neighboring radiators. Those elements which had nearest neighbors at least five wavelengths away were located near the middle of the array. Their radiation patterns displayed sonic small, symmetric ripple across their full azimuth range. The patterns of elements that lie within 2.5 wavelengths of their neighbors showed stronger and asymmetric features. These are believed to be caused by mutual coupling among these structures. Evidence for this was seen when an antenna position was displaced by 0.05 wavelengths, Its pattern and those of its near neighbors were seen to change. Displacement within the plane of the array were observed to have different effects than displacements out-of-plane. A program of data analysis and theoretical development is in progress to provide a physical interpretation of the properties of these antenna patterns and to develop methods which can optimize the performance of this synthetic aperture imaging system. This includes compensation for pattern asymmetries and element position perturbation.

Weissman, David E.↗

Brief Communication: Preliminary ICESat-2 (Ice, Cloud and Land Elevation Satellite-2) Measurements of Outlet Glaciers Reveal Heterogeneous Patterns of Seasonal Dynamic Thickness Change

Dynamic changes of marine-terminating outlet glaciers are projected to be responsible for about half of future ice loss from the Greenland Ice Sheet. However, we lack a unified, process-based understanding that can explain the observed dynamic changes of all outlet glaciers. Many glaciers undergo seasonal dynamic thickness changes, and classifying the patterns of seasonal thickness change can improve our understanding of the processes that drive glacier behavior. The Ice, Cloud and land Elevation Satellite-2 (ICESat-2) provides space-based, seasonally repeating altimetry measurements of the ice sheets, allowing us to quantify near-termini seasonal dynamic thickness patterns of 37 outlet glaciers around the Greenland Ice Sheet. We classify the glaciers into seven common patterns of seasonal thickness change over a 2-year period from 2019 to 2020. We find small groupings of neighboring glaciers with similar patterns of seasonal thickness change, but, within larger sectors of the ice sheet, patterns of seasonal thickness change are mostly heterogeneous. Future studies can build upon our results by extending these time series, comparing seasonal dynamic thickness changes with external forcings, such as ocean temperature and meltwater runoff, and with other dynamic variables such as seasonal glacier velocity and terminus position changes.