A Novel Ku-Band/Ka-Band and Ka-Band/E-Band Multimode Waveguide Couplers for Power Measurement of Traveling-Wave Tube Amplifier Harmonic Frequencies

This paper presents the design, fabrication and test results for a novel waveguide multimode directional coupler (MDC). The coupler, fabricated from two dissimilar frequency band waveguides, is capable of isolating power at the second harmonic frequency from the fundamental power at the output port of a traveling-wave tube (TWT) amplifier. Test results from proof-of-concept demonstrations are presented for a Ku-band/Ka-band MDC and a Ka-band/E-band MDC. In addition to power measurements at harmonic frequencies, a potential application of the MDC is in the design of a satellite borne beacon source for atmospheric propagation studies at millimeter-wave (mm-wave) frequencies (Ka-band and E-band).

Wintucky, Edwin G.↗

Multimode Bolometer Development for the Primordial Inflation Explorer (PIXIE) Instrument

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background [1]. In this work, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances in the detector design, including the implementation of a tensioning scheme to greatly raise the frequencies of the internal vibrational modes of the large-area, low-mass optical absorber structure consisting of a grid of micromachined, ion-implanted silicon wires. With 30 times the absorbing area of the spider-web bolometers used by Planck, the tensioning scheme enables the PIXIE bolometers to be robust in the vibrational and acoustic environment at launch of the space mission. More generally, it could be used to reduce microphonic sensitivity in other types of low temperature detectors. We also report on the performance of the PIXIE bolometers in a dark cryogenic environment.

PIXIE↗

Multimode Bolometer Development for the PIXIE Instrument

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background. In the following, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances in the detector design, including the implementation of a scheme to greatly raise the frequencies of the internal vibrational modes of the large-area, low-mass optical absorber structure consisting of a grid of micromachined, ion-implanted silicon wires. With approximately 30 times the absorbing area of the spider-web bolometers used by Planck, the tensioning scheme enables the PIXIE bolometers to be robust in the vibrational and acoustic environment at launch of the space mission. More generally, it could be used to reduce microphonic sensitivity in other types of low temperature detectors. We also report on the performance of the PIXIE bolometers in a dark cryogenic environment.

PIXIE↗

Prediction of Cognitive States During Flight Simulation Using Multimodal Psychophysiological Sensing

The Commercial Aviation Safety Team found the majority of recent international commercial aviation accidents attributable to loss of control inflight involved flight crew loss of airplane state awareness (ASA), and distraction was involved in all of them. Research on attention-related human performance limiting states (AHPLS) such as channelized attention, diverted attention, startle/surprise, and confirmation bias, has been recommended in a Safety Enhancement (SE) entitled "Training for Attention Management." To accomplish the detection of such cognitive and psychophysiological states, a broad suite of sensors was implemented to simultaneously measure their physiological markers during a high fidelity flight simulation human subject study. Twenty-four pilot participants were asked to wear the sensors while they performed benchmark tasks and motion-based flight scenarios designed to induce AHPLS. Pattern classification was employed to predict the occurrence of AHPLS during flight simulation also designed to induce those states. Classifier training data were collected during performance of the benchmark tasks. Multimodal classification was performed, using pre-processed electroencephalography, galvanic skin response, electrocardiogram, and respiration signals as input features. A combination of one, some or all modalities were used. Extreme gradient boosting, random forest and two support vector machine classifiers were implemented. The best accuracy for each modality-classifier combination is reported. Results using a select set of features and using the full set of available features are presented. Further, results are presented for training one classifier with the combined features and for training multiple classifiers with features from each modality separately. Using the select set of features and combined training, multistate prediction accuracy averaged 0.64 +/- 0.14 across thirteen participants and was significantly higher than that for the separate training case. These results support the goal of demonstrating simultaneous real-time classification of multiple states using multiple sensing modalities in high fidelity flight simulators. This detection is intended to support and inform training methods under development to mitigate the loss of ASA and thus reduce accidents and incidents.

Harrivel, Angela R.↗

Waveguide Multimode Directional Coupler for Harvesting Harmonic Power from the Output of Traveling-Wave Tube Amplifiers

This paper presents the design, fabrication, and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from dissimilar frequency band waveguides, is capable of isolating power at the 2nd harmonic frequency from the fundamental power at the output port of traveling-wave tube amplifiers. Test results from proof-of-concept demonstrations are presented for Ku/Ka-band and Ka/E-band MDCs, which demonstrate sufficient power in the 2nd harmonic for a space borne beacon source for mm-wave atmospheric propagation studies.

Directional Coupler↗

Waveguide Multimode Directional Coupler for Harvesting Harmonic Power from the Output of Traveling-Wave Tube Amplifiers

The paper presents the design, fabrication, and test results for a novel waveguide multimode directional coupler (MDC). The coupler fabricated from dissimilar frequency band waveguides, is capable of isolating power at the 2nd harmonic frequency from the fundamental power at the output port of a high power traveling-wave tube amplifier. The major advantage of the MDC is significantly lower insertion loss compared to a diplexer. The presentation slides for the paper that was approved is attached. The tracking number for the paper that was approved is TN 37015.

Directional Coupler↗

TeleLayering: Teleoperated Construction 3D Printing Using Multimodal Feedback for Extraterrestrial and Terrestrial Construction

In this paper, we propose a teleoperated construction 3D printing technology, called TeleLayering, for planetary and terrestrial applications. The TeleLayering technology is enabled by effective multimodal control and monitoring systems and enhanced construction 3D printing robots to build or repair a variety of structures in extreme environments without the need for human presence on the jobsite. This paper presents a general description, main technical requirements, implementation challenges, and applications of this technology.

TeleLayering↗

Universal liquid sample device and process for high resolution transmission electron microscope imaging and multimodal analyses of liquid sample materials

Liquid sample imaging devices and processes are disclosed for high resolution TEM imaging and multimodal analyses of liquid sample materials in situ under high vacuum that are compatible with standard type TEM chip membranes and TEM sample holders allowing TEM liquid sample imaging to be performed wherever a TEM instrument is accessible and at a substantially reduced cost compared to prior art systems and approaches.

36 MATERIALS SCIENCE↗

Multimodal Data Representation with Deep Learning for Extracting Cancer Characteristics from Clinical Text

This paper presents a multimodal data representation to improve the performance of deep learning models for extracting cancer key characteristics from unstructured text in pathology reports. Specifically, in addition to using the text as the input to deep learning models, we use concept unique identifiers (CUIs) as another source of information to the models. We analyze the performance of different text and CUI data representations, including word embeddings and bag of embeddings (BOE), with a convolutional neural network (CNN) and a fully connected multilayer perceptron neural network (MLP-NN). The high level document embeddings from text and CUI inputs are combined by concatenating them and then applying a classifier. The model is used for extracting cancer subsite and histology from pathology reports. These two classification tasks have a large number of labels, i.e. 317 for subsite and 556 for histology, with extreme class imbalance. We compare the performance of the developed DL models across the two tasks based on micro- and macro-F1 scores. The evaluation shows that a multi-channel DL model that utilizes text represented by word embeddings and CUIs represented by BOE outperforms other DL models. Also, this approach significantly improves the model performance on low prevalence classes.

Alawad, Mohammed↗

Multimodal communication system

A multimodal communication system includes a vehicle controller that controls one or more systems or subsystems of an unmanned vehicle. The communication controller manages communication and logical access to the unmanned vehicle. One or more sensors in communication with the communication controller detects and measures physical properties in proximity to the unmanned vehicle. Transceivers receive the unmanned vehicle commands that are transmitted simultaneously or concurrently and a monotonic generator generates a monotonic object each time the unmanned vehicle's operating state changes. The communication controller executes the first unmanned vehicle command received that has the correct cryptographic hash validating knowledge of the unmanned vehicle's current operating state.

Duncan, Andrew M.↗

Multimodal photon and neutron imaging devices with fast event-by-event multisampling readout and optimized particle type discrimination

A particle imaging method for distinguishing between types of incident particles, such as neutrons, photons, and alphas, and improving the position resolution of particle imaging devices with matrix readout. The method includes high frequency multisampling readout electronics that provides the sequences of multiple measurements for each detected event, resulting in recorded detailed waveform information describing the signals. Such detailed information is used to approximate each signal waveform with a parameterized function in which the extracted parameter sets determine the type of the incident particle in an optimized fashion. The detailed event-by-event multisampling information for each signal readout channel in the matrix readout of the radiation imaging devices improves and optimizes the position resolution for variable shapes of the signals. Such devices can be used in mixed radiation fields, creating a new class of multimodal photon and neutron imagers.

Degtiarenko, Pavel V.↗

Multimodal nonlinear optical imaging via evanescent wave excitation

A system for multimodal nonlinear optical imaging is provided. Each mode uses a high NA objective to cause total internal reflection excitation at a sample-substrate interface. The system has a femtosecond oscillator to generate pulses used for two beams. The objective receives at least one beam, redirects the received at least one beam through a dielectric substrate to cause the TIR and produces corresponding evanescent waves in a portion of the sample adjacent to the sample-substrate interface, and collects a backward-propagating beam of pulses of responsive light. The portion of the sample illuminated by the evanescent waves emits responsive light. Different modes or combinations of the distinct modalities may be selected to access complementary chemical and structural information for various chemical species near the sample-substrate interface. Each mode may have mode-specific control such as selective beam blocking, power ratios and filtering.

Doughty, Benjamin L.↗

Towards Content Authenticity: Multimodal Fake News Detection and AI-Generated Text Identification

In today’s digital world, the spread of fake news and the rise of AI-generated text have become major threats to content authenticity and public trust. This thesis addresses both challenges through two complementary research directions: detecting fake news using multimodal features, and identifying AI-generated text using semantic and structural reasoning. The first part of the work focuses on fake news detection by introducing a novel model that combines text and image features through a unique rotational attention mechanism. Unlike traditional attention methods, this approach rotates the roles of query, key, and value across modalities to capture deeper interactions. Additionally, the model incorporates external domain information by linking news posts to top-ranked websites from Google search results, which helps assess the credibility of content based on its broader web context. This results in a more reliable and accurate fake news detection system that outperforms existing state-of-the-art methods. The second part presents SGG-ATD, a new framework for detecting AI-generated text. It uses masked language modeling to measure sentence coherence, followed by constructing a graph where keywords—both original and predicted—are connected based on semantic and contextual similarity. A Graph Convolutional Network (GCN) is then used to learn structural relationships within the text for final classification. Experimental results demonstrate that SGG-ATD achieves high F1-scores and consistently outperforms strong baselines. This method contributes to robust AI text detection, supporting accountability and resilience against AI-driven misinformation.

Gupta, Nidhi↗

Universal monitored dynamics in multimode bosonic systems

We propose a route to study monitored many-body dynamics in multimode bosonic systems using circuit quantum electrodynamics. In this experimental setting, we construct several bosonic models comprising brickwork circuits built from beam-splitter gates, local parity measurements, and optional on-site Hubbard interactions, and diagnose their monitored dynamics via ancilla purification and a learnability-based probe. Under parity measurements, generic gate sets exhibit behavior that is largely consistent with a conventional measurement-induced phase transition, while a special class of beam-splitter circuits shows an apparent critical-like high-measurement regime in which purification times scale linearly with system size. We show that for realistic noise, gate, and measurement rates, these signatures are observable with near-term circuit QED hardware.

Patel, Shivam [Rutgers U., Piscataway]↗

3D and Multimodal X‐Ray Microscopy Reveals the Impact of Voids in CIGS Solar Cells

Small voids in the absorber layer of thin-film solar cells are generally suspected to impair photovoltaic performance. They have been studied on Cu(In,Ga)Se 2 cells with conventional laboratory techniques, albeit limited to surface characterization and often affected by sample-preparation artifacts. Here, synchrotron imaging is performed on a fully operational as-deposited solar cell containing a few tens of voids. By measuring operando current and X-ray excited optical luminescence, the local electrical and optical performance in the proximity of the voids are estimated, and via ptychographic tomography, the depth in the absorber of the voids is quantified. Besides, the complex network of material-deficit structures between the absorber and the top electrode is highlighted. Despite certain local impairments, the massive presence of voids in the absorber suggests they only have a limited detrimental impact on performance.