Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Topographical Mapping With Synthetic-Aperture Radar

Interferometric side-looking synthetic-aperture radar shows promise for high-resolution topographical mapping of terrain. Airplane carries two radar antennas. Radar signal transmitted by right antenna, reflected from ground received by both antennas. Amplitudes and phases of received signals recorded and processed separately to yield two 10-m-resolution amplitude-and-phase images of illuminated terrain. Two images mathematically combined point by point to obtain signal image containing interference fringes: phase at each location of image is difference between phases in two signals and amplitude at each location is project of amplitudes of two signals. Theoretically, technique has potential to attain a root-mean-square (rms) altitude error as small as 2 m.

Zebker, Howard A.↗

X-ray Phase Contrast Imaging of Calcified Tissue and Biomaterial Structure in Bioreactor Engineered Tissues

Tissues engineered in bioreactor systems have been used clinically to replace damaged tissues and organs. In addition, these systems are under continued development for many tissue engineering applications. The ability to quantitatively assess material structure and tissue formation is critical for evaluating bioreactor efficacy and for preimplantation assessment of tissue quality. These techniques allow for the nondestructive and longitudinal monitoring of large engineered tissues within the bioreactor systems and will be essential for the translation of these strategies to viable clinical therapies. X-ray Phase Contrast (XPC) imaging techniques have shown tremendous promise for a number of biomedical applications owing to their ability to provide image contrast based on multiple X-ray properties, including absorption, refraction, and scatter. In this research, mesenchymal stem cell-seeded alginate hydrogels were prepared and cultured under osteogenic conditions in a perfusion bioreactor. The constructs were imaged at various time points using XPC microcomputed tomography (µCT). Imaging was performed with systems using both synchrotron- and tube-based X-ray sources. XPC µCT allowed for simultaneous three-dimensional (3D) quantification of hydrogel size and mineralization, as well as spatial information on hydrogel structure and mineralization. Samples were processed for histological evaluation and XPC showed similar features to histology and quantitative analysis consistent with the histomorphometry. Furthermore, these results provide evidence of the significant potential of techniques based on XPC for noninvasive 3D imaging engineered tissues grown in bioreactors.

alginate microbeads↗

EOS Moderate Resolution Imaging Spectroradiometer - Phase C/D status and comments on calibration and georeferencing approaches

The Moderate Resolution Imaging Spectroradiometer-Nadir (MODIS-N) is a key observing instrument to be flown on the Earth Observing System (EOS). The MODIS-N is being built under contract to NASA by the Santa Barbara Research Center. MODIS-N is a 36-band instrument with bands chosen in the visible through the emitted thermal IR part of the electromagnetic spectrum to observe key features of the Earth's land and ocean surfaces plus the properties of clouds and other constituents in the troposphere. To provide improved radiometric accuracy, several on-board approaches are used to monitor the calibration of the instrument. The calibration accuracy requirements are 5 percent absolute in the reflected solar radiation observations, 2 percent relative to the sun, and 1 percent absolute in the emitted thermal IR. Requirements for georeferencing of observations are still under study. At the present time, it appears that MODIS-N pixels can be georeferenced to better than 500 meters based on the EOS pointing knowledge capabilities.

Salomonson, Vincent V.↗

The effect of scanning jitter on geometric phase analysis in STEM images

Geometric phase analysis (GPA) is a useful method to map strain distribution in atomically resolved scanning/transmission electron microscopy (S/TEM) images. Nevertheless, the inevitable periodic jitter of electron probe in STEM along the scanning direction due to the interference of electric power supply, including grounding, can give rise to major artifacts, as evidenced by the appearance of satellite spots surrounding all main peaks in the power spectrum of the images. Here we reveal the origin of the image artifacts related to the probe jitter by mapping the image distortion component εxx using the GPA algorithm. The effect is verified by introducing a periodic displacement field to a STEM image simulated from a perfect crystal structure, and the calculated εxx maps show very good agreement with the experimental observations. Based on the quantitative analysis of the images distortion, we propose and test a feasible strategy to eliminate the effect of probe jitter from STEM images. Successful examples illustrate that the approach can help improve the accuracy in quantification of STEM images.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulation of ocean SAR images via phase history generation

A method for simulating an ocean synthetic-aperture radar (SAR) image is illustrated for a simple internal wave current pattern. The method calculates both the amplitude image and the radar signal history. The simulation model used consists of six stages. In the first stage, the full wave spectrum in two spatial coordinates is calculated from the wind speed and direction using the action spectral density equation. In the second stage, the pixel size is selected and used as the basis for dividing the spectrum into large and small scale motions. Realizations for the large-scale ocean surface height and velocity are then calculated. In the third stage, the sensor wavelength and geometry are used to calculate the small scale statistics (radar cross section, coherence time, root-mean square (RMS), radial velocity and RMS slope). In the fourth stage, an autoregressive method is used to generate a realization of the surface reflectivity history that is consistent with the radial velocity and the radial velocity variance. In the fifth stage, the signal history is generated by summing the reflectivities at the proper times with the appropriate antenna weighting function for the SAR. As a consequence of this process, speckle is automatically included in the signal. In the final stage, the SAR image can be created by using any of the traditional ways to process the signal history, including variable focusing and multilook processing.

Bennett, John R.↗

Identification of breast calcification using magnetic resonance imaging

MRI phase and magnitude images provide information about local magnetic field variation ({Delta}B{sub 0}), which can consequently be used to understand tissue properties. Often, phase information is discarded. However, corrected phase images are able to produce contrast as a result of magnetic susceptibility differences and local field inhomogeneities due to the presence of diamagnetic and paramagnetic substances. Three-dimensional (3D) susceptibility weighted imaging (SWI) can be used to probe changes in MRI phase evolution and, subsequently, result in an alternate form of contrast between tissues. For example, SWI has been useful in the assessment of negative phase induced {Delta}B{sub 0} modulation due to the presence of paramagnetic substances such as iron. Very little, however, has been done to assess positive phase induced contrast changes resulting from the presence of diamagnetic substances such as precipitated calcium. As ductal carcinoma in situ, which is the precursor of invasive ductal cancer, is often associated with breast microcalcification, the authors proposed using SWI as a possible visualization technique. In this study, breast phantoms containing calcifications (0.4-1.5 mm) were imaged using mammography, computed tomography (CT), and SWI. Corrected phase and magnitude images acquired using SWI allowed identification and correlation of all calcifications seen on CT. As the approach is a 3D technique, it could potentially allow for more accurate localization and biopsy and maybe even reduce the use of gadolinium contrast. Furthermore, the approach may be beneficial to women with dense breast tissue where the ability to detect microcalcification with mammography is reduced.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-shot in-line x-ray phase-contrast imaging of void-shockwave interactions in fusion energy materials

Recent breakthroughs in nuclear fusion, specifically the report of reactions exceeding scientific breakeven at the National Ignition Facility (NIF), highlight the potential of inertial fusion energy (IFE) as a sustainable and virtually limitless energy source. However, further progress in IFE requires characterization of defects in ablator materials and how they affect fuel capsule compression. Voids within the ablator can degrade energy yield, but their impact on the density distribution has primarily been studied through simulations, with limited high-resolution experimental validation. To address this, we used the x-ray free-electron laser (XFEL) at the matter in extreme conditions (MECs) instrument at the Linac coherent light source (LCLS) to capture 2D x-ray phase-contrast (XPC) images of a void-bearing sample with a composition similar to inertial confinement fusion (ICF) ablators. By driving a compressive shockwave through the sample using MEC's long-pulse laser system, we analyzed how voids influence shockwave propagation and density distribution during compression. To quantify this impact, we extracted phase information using two phase retrieval algorithms. First, we applied the contrast transfer function (CTF) method, paired with Tikhonov regularization and a fast optimization approach to generate an initial phase estimate. We then refined the result using a projected gradient descent (PGD) method that works directly with the sample's refractive index. Comparing these results with radiation adaptive grid Eulerian (xRAGE) radiation hydrodynamic simulations enables identification of model validation needs or improvements. By calculating phase maps in situ, it becomes possible to reconstruct areal density maps, improving understanding of laser-capsule interactions and advancing IFE research.

Hodge, D. S. [Colorado State Univ., Fort Collins, ↗

Spectral gratings-based phase-contrast imaging for materials characterization

Spectral X-ray detectors provide a direct observation of the energy spectrum of a transmitted X-ray beam, both for typical and phase-contrast gratings-based systems. The sensitivity of a gratings-based X-ray system to small-angle deflections from a given particle size is dependent on X-ray energy. Therefore, spectral (energy-sensitive) detectors could be sensitive to particle size, even with a broad spectrum from a commercial X-ray generator. Furthermore, these detectors allow direct observation of how the X-ray spectrum is changing as the beam is passing through an object and gratings, and how this affects grating visibilities used to determine the presence of small-angle deflections. This is a particular issue for higher-energy systems where artifacts from beam hardening are common. We present results exploring the particle-size dependent signatures that are available from a spectral gratings-based phase-contrast X-ray imaging system, and the feasibility of observing them with lab-based, broad-spectrum X-ray generators.

Gilbert, Andrew J.↗

Planning Study Comparison of Real-Time Target Tracking and Four-Dimensional Inverse Planning for Managing Patient Respiratory Motion

Purpose: Real-time target tracking (RT-TT) and four-dimensional inverse planning (4D-IP) are two potential methods to manage respiratory target motion. In this study, we evaluated each method using the cumulative dose-volume criteria in lung cancer radiotherapy. Methods and Materials: Respiration-correlated computed tomography scans were acquired for 4 patients. Deformable image registration was applied to generate a displacement mapping for each phase image of the respiration-correlated computed tomography images. First, the dose distribution for the organs of interest obtained from an idealized RT-TT technique was evaluated, assuming perfect knowledge of organ motion and beam tracking. Inverse planning was performed on each phase image separately. The treatment dose to the organs of interest was then accumulated from the optimized plans. Second, 4D-IP was performed using the probability density function of respiratory motion. The beam arrangement, prescription dose, and objectives were consistent in both planning methods. The dose-volume and equivalent uniform dose in the target volume, lung, heart, and spinal cord were used for the evaluation. Results: The cumulative dose in the target was similar for both techniques. The equivalent uniform dose of the lung, heart, and spinal cord was 4.6 {+-} 2.2, 11 {+-} 4.4, and 11 {+-} 6.6 Gy for RT-TT with a 0-mm target margin, 5.2 {+-} 3.1, 12 {+-} 5.9, and 12 {+-} 7.8 Gy for RT-TT with a 2-mm target margin, and 5.3 {+-} 2.3, 11.9 {+-} 5.0, and 12 {+-} 5.6 Gy for 4D-IP, respectively. Conclusion: The results of our study have shown that 4D-IP can achieve plans similar to those achieved by RT-TT. Considering clinical implementation, 4D-IP could be a more reliable and practical method to manage patient respiration-induced motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ALMA Band-to-band Phase Referencing: Imaging Capabilities on Long Baselines and High Frequencies

High-frequency long-baseline experiments with the Atacama Large Millimeter/submillimeter Array were organized to test the high angular resolution imaging capabilities in the submillimeter wave regime using baselines up to 16 km. Four experiments were conducted, two Band 7 (289 GHz) and two Band 8 (405 GHz) observations. Phase correction using band-to-band (B2B) phase referencing was used with a phase calibrator only [[Formula]] away observed in Band 3 (96 GHz) and Band 4 (135 GHz), respectively. In Band 8, we achieved the highest resolution of 14 × 11 mas. We compared the synthesis images of the target quasar using 20 and 60 s switching cycle times in the phase referencing. In Band 7, the atmosphere had good stability in phase rms (<0.5 rad over 2 minutes), and there was little difference in image coherence between the 20 and 60 s switching cycle times. One Band 8 experiment was conducted under a worse phase rms condition (>1 rad over 2 minutes), which led to a significantly reduced coherence when using the 60 s switching cycle time. One of our four experiments indicates that the residual phase rms error after phase referencing can be reduced to 0.16 rad at 289 GHz in using the 20 s switching cycle time. Such conditions would meet the phase correction requirement of image coherence of >70% in Band 10, assuming a similar phase calibrator separation angle, emphasizing the need for such B2B phase referencing observing at high frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Keck Segment Surface Artifacts: Impacts on Segment Phasing and Image Quality

We show that the segments of the Keck telescopes su er from small but signi cant surface artifacts that limit segment phasing accuracy. Both the segment surface artifacts themselves and the limits they place on segment phasing have important implications for adaptive optics, high contrast imaging, and seeing limited observations. These surface artifacts are likely by-products of the segment polishing, most likely the Ion Beam Figuring (IBF) process that constitutes the nal step of the segment surface guring. The surface artifacts di ract a signi cant amount of light out past 3.5 arcseconds and generate chromatic e ects that limit segment phasing accuracy. We present on-sky measurements of the di racted intensity. Segment surface roughness measurements are also presented, which show that surface roughness is not the source of the problem. These results have direct relevance to segment manufacturing for the Thirty Meter Telescope (TMT) and other segmented mirror telescopes.

Brock, Neal↗

SU-F-J-169: A Feasibility Study of Using MRI Alone in Abdominal Radiotherapy

Purpose: To demonstrate the feasibility of a MRI alone workflow to support treatment planning and image guidance for abdominal radiotherapy. Methods: Abdominal MR images (in-phase/out-phase/fat/water) were acquired for a patient with breath-hold using a Dixon pulse sequence. Air masks were created on in-phase images using intensity thresholding and morphological processing methods in order to separate air from bone. Pseudo-CT and DRRs were generated using a published method. To investigate the effect of heterogeneity corrections on dose calculations using pseudo-CT, three different plans (3-field 3D, 5-field IMRT and 2-arc VMAT) were performed to mimic pancreatic treatments (1.8Gy/fraction over 28 fractions). Results: The DRRs created from pseudo-CT were of comparable quality as those created from CT. Comparing dose calculations with and without heterogeneity corrections between the 3 different plans, the biggest dosimetric differences were seen in the VMAT plan where modulation must occur across air-tissue interfaces such as those of the stomach and bowel. The DVHs for the VMAT plan showed ∼84cc difference at V50Gy in the small bowel. In terms of pseudo-CT quality, some small volumes of air in the bowel and stomach were misclassified as bone. The VMAT plan was re-optimized on pseudo-CT with 0 HU in the misclassified areas. The V50Gy in the small bowel differed by ∼90cc between the new VMAT plan with and without heterogeneity corrections. Conclusion: We found that the use of MRI alone is feasible for abdominal treatment planning and image guidance. A difference between calculations with and without heterogeneity corrections was found that is most pronounced for VMAT where the traversal of air-tissue interfaces is unavoidable. Future work will be performed to minimize misclassification between bone and air.

60 APPLIED LIFE SCIENCES↗

Experimental verification of tomographic phase-space imaging for beams with space-charge using a pinhole-scan

A model is described for tomographic phase-space mapping and emittance measurement in beams with space-charge. The tomographic results of an experiment with a 10 keV space-charge dominated electron beam are presented. The data are compared against a direct experimental sampling of the phase-space using a pinhole scan. It is found that the accuracy of the tomographic method is within 10% for beams with space-charge intensity less than 90%. With the aid of numerical simulation the observed similarities and differences between the tomography method and pinhole scan are discussed.

43 PARTICLE ACCELERATORS↗

Two-beam ultrabroadband coherent anti-Stokes Raman spectroscopy for high resolution gas-phase multiplex imaging

We propose and develop a method for wideband coherent anti-Stokes Raman spectroscopy (CARS) in the gas phase and demonstrate the single-shot measurement of N{sub 2}, H{sub 2}, CO{sub 2}, O{sub 2}, and CH{sub 4}. Pure-rotational and vibrational O-, Q-, and S- branch spectra are collected simultaneously, with high spectral and spatial resolution, and within a single-laser-shot. The relative intensity of the rotational and vibrational signals can be tuned arbitrarily using polarization techniques. The ultrashort 7 fs pump and Stokes pulses are automatically overlapped temporally and spatially using a two-beam CARS technique, and the crossed probe beam allows for excellent spatial sectioning of the probed location.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experience with 800 x 800 virtual phase and 500 x 500 three-phase CCD imagers

A description of the Galileo/Institute for Astronomy charge-coupled device (CCD) imaging system and its initial operation has been presented previously. Originally designed to operate a 500 x 500 backside illuminated three-phase CCD, the system has been modified to allow use of either the 500 x 500 sensor or the TI 800 x 800 virtual phase CCD. The modifications for the operation of the virtual phase CCD and current system performance with each type of sensor are discussed. A description is given of the implementation of various techniques discovered at the Jet Propulsion Laboratory that improve imager performance. These techniques include tri-level clocking of the virtual phase CCD to eliminate spurious charge generation in the serial register, the use of ultraviolet light flood with the backside thinned 500 x 500 three-phase device to dramatically improve the quantum efficiency in the blue, and the practical elimination of deferred charge in the three-phase device. Results of astronomical observations with each sensor are presented.

Hlivak, R. J.↗

Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO{sup ®} UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗