X-Band Scanning ARM Cloud Radar (XSACR) Cross-Wind RHI Scan Corrected (c1)
X-Band Scanning ARM Cloud Radar (XSACR) Cross-Wind RHI Scan Corrected
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
X-Band Scanning ARM Cloud Radar (XSACR) Cross-Wind RHI Scan Corrected
X-Band Scanning ARM Cloud Radar (XSACR) Vertically Pointing Scan Corrected
X-Band Scanning ARM Cloud Radar (XSACR) Boundary Layer RHI Scan Corrected
Grid method for constructing scan lines generated by Tiros scanning radiometers
Signal conversion system converts slow-scan video signals into standard fast-scan television signals that are required for reproduction of television pictures on American TV sets. This system permits conversion of TV pictures produced in accordance with the standards of one country into the standards of another country.
Scanning electron mirror microscope advantages over electron mirror and scanning electron microscopes for examining integrated circuits
An ultrasonic data display system was developed at NASA Lewis Research Center that allows the user to interactively examine digitized waveforms and processed information associated with any specific scan location of an ultrasonic contact scan. This information is displayed on a video display monitor and includes acquired time-domain waveforms, frequency-domain magnitude and phase spectra, and ultrasonic properties (pulse velocity, phase velocity, reflection coefficient, attenuation coefficient, attenuation coefficient error) as a function of frequency for a material. This report describes the system features and illustrates the system's usefulness for nondestructive materials characterization.
A miniature, ultra-high resolution, and color scanning microscope using microchannel and solid-state technology that does not require focus adjustment. One embodiment includes a source of collimated radiant energy for illuminating a sample, a plurality of narrow angle filters comprising a microchannel structure to permit the passage of only unscattered radiant energy through the microchannels with some portion of the radiant energy entering the microchannels from the sample, a solid-state sensor array attached to the microchannel structure, the microchannels being aligned with an element of the solid-state sensor array, that portion of the radiant energy entering the microchannels parallel to the microchannel walls travels to the sensor element generating an electrical signal from which an image is reconstructed by an external device, and a moving element for movement of the microchannel structure relative to the sample. Discloses a method for scanning samples whereby the sensor array elements trace parallel paths that are arbitrarily close to the parallel paths traced by other elements of the array.
No abstract prepared.
X-ray nanotomography and focused ion beam scanning electron microscopy (FIB-SEM) have been applied to investigate the complex 3D microstructure of solid oxide fuel cell (SOFC) electrodes at spatial resolutions of 45 nm and below. The application of near edge differential absorption for x-ray nanotomography and energy selected backscatter detection for FIB-SEM enable elemental mapping within the microstructure. Using these methods, non-destructive 3D x-ray imaging and FIB-SEM serial sectioning have been applied to compare three-dimensional elemental mapping of the LSM, YSZ, and pore phases in the SOFC cathode microstructure. The microstructural characterization of an SOFC cathode is reported based on these measurements. The results presented demonstrate the viability of x-ray nanotomography as a quantitative characterization technique and provide key insights into the SOFC cathode microstructure.
We suggest the SPM module to combine SEM and SPM methods for studying surfaces. The module is based on the original mechanical moving and scanning system. The examples of studies of the steel surface microstructure in both SEM and SPM modes are presented.
Kondo systems ranging from the single Kondo impurity to heavy fermion materials present us with a plethora of unconventional properties whose theoretical understanding is still one of the major open problems in condensed matter physics. Over the last few years, groundbreaking scanning tunneling spectroscopy (STS) experiments have provided unprecedented new insight into the electronic structure of Kondo systems. Interpreting the results of these experiments–the differential conductance and the quasi-particle interference spectrum–however, has been complicated by the fact that electrons tunneling from the STS tip into the system can tunnel either into the heavy magnetic moment or the light conduction band states. In this article, we briefly review the theoretical progress made in understanding how quantum interference between these two tunneling paths affects the experimental STS results. We show how this theoretical insight has allowed to interpret the results of STS experiments on a series of heavy fermion materials providing detailed knowledge of their complex electronic structure. Furthermore, it is this knowledge that is a conditio sine qua non for developing a deeper understanding of the fascinating properties exhibited by heavy fermion materials, ranging from unconventional superconductivity to non-Fermi-liquid behavior in the vicinity of quantum critical points.
We present direct experimental evidence of Anderson localization induced by the intrinsic alloy compositional disorder of InGaN/GaN quantum wells. Our approach relies on the measurement of the luminescence spectrum under local injection of electrons from a scanning tunneling microscope tip into a near-surface single quantum well. Fluctuations in the emission line shape are observed on a few-nanometer scale. Narrow emission peaks characteristic of single localized states are resolved. Calculations in the framework of the localization landscape theory provide the effective confining potential map stemming from composition fluctuations. This theory explains well the observed nanometer scale carrier localization and the energies of these Anderson-type localized states. In conclusion, the energy spreading of the emission from localized states is consistent with the usually observed very broad photo- or electroluminescence spectra of InGaN/GaN quantum well structures.
We used a focused ion beam to obtain cross-sectional specimens from both magnetic multilayer and Nb/Al-AlOx/Nb Josephson junction devices for characterization by scanning transmission electron microscopy (STEM) and energy dispersive X-ray spectroscopy (EDX). An automated multivariate statistical analysis of the EDX spectral images produced chemically unique component images of individual layers within the multilayer structures. STEM imaging elucidated distinct variations in film morphology, interface quality, and/or etch artifacts that could be correlated to magnetic and/or electrical properties measured on the same devices.
Explore the source record for details and available documents.