Search NASA⌕ Search

SEARCH · Search NASA

Results for “SNR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

G306.3-0.9: A Newly Discovered Young Galactic Supernova Remnant

We present X-ray and radio observations of the new Galactic supernova remnant (SNR) G306.3−0.9, recently discovered by Swift. Chandra imaging reveals a complex morphology, dominated by a bright shock. The X-ray spectrum is broadly consistent with a young SNR in the Sedov phase, implying an age of 2500 yr for a distance of 8 kpc, plausibly identifying this as one of the 20 youngest Galactic SNRs. Australia Telescope Compact Array imaging reveals a prominent ridge of radio emission that correlates with the X-ray emission. We find a flux density of ∼160 mJy at 1 GHz, which is the lowest radio flux recorded for a Galactic SNR to date. The remnant is also detected at 24μm, indicating the presence of irradiated warm dust. The data reveal no compelling evidence for the presence of a compact stellar remnant.

remnant↗

The Refined Shock Velocity of the X-Ray Filaments in the RCW 86 Northeast Rim

A precise measurement of shock velocities is crucial for constraining the mechanism and efficiency of cosmic-ray (CR) acceleration at supernova remnant (SNR) shock fronts. The northeastern rim of the SNR RCW 86 is thought to be a particularly efficient CR acceleration site, owing to the recent result in which an extremely high shock velocity of 6000 km s1 was claimed. Here, we revisit the same SNR rim with the Chandra X-ray Observatory, 11 years after the first observation. This longer baseline than previously available allows us to determine a more accurate proper motion of the nonthermal X-ray filament, revealing a much lower velocity of 3000 340 km s1 (and even slower at a brighter region). Although the value has dropped to one-half of that from the previous X-ray measurement, it is still higher than the mean velocity of the H filaments in this region (1200 km s1). This discrepancy implies that the filaments bright in nonthermal X-rays and H emission trace different velocity components, and thus a CR pressure constrained by combining the X-ray kinematics and the H spectroscopy can easily be overestimated. We also measure the proper motion of the thermal X-ray filament immediately to the south of the nonthermal one. The inferred velocity (720 360 km s1) is significantly lower than that of the nonthermal filament, suggesting the presence of denser ambient material, possibly a wall formed by a wind from the progenitor, which has drastically slowed down the shock.

acceleration of particles - ISM: individuals objec↗

The Origin of the Iron-Rich Knot in Tycho's Supernova Remnant

X-ray observations of supernova remnants (SNRs) allow us to investigate the chemical inhomogeneity of ejecta, offering unique insight into the nucleosynthesis in supernova explosions. Here we present detailed imaging and spectroscopic studies of the Fe knot located along the eastern rim of the Type Ia SNR Tycho ( SN 1572) using Suzaku and Chandra long-exposure data. Surprisingly, the Suzaku spectrum of this knot shows no emission from Cr, Mn, or Ni, which is unusual for the Fe-rich regions in this SNR. Within the framework of the canonical delayed-detonation models for SN Ia, the observed mass ratios M(sub Cr)/M(sub Fe) is less than 0.023, M(sub Mn)/M(sub Fe) is less than 0.012, and M(sub Ni)/M(sub Fe) is less than 0.029 (at 90% confidence) can only be achieved for a peak temperature of (5.3 - 5.7) x 10(exp. 9) K and a neutron excess of approximately less than 2.0 x 10(exp. -3). These constraints rule out the deep, dense core of a Chandrasekhar-mass white dwarf as the origin of the Fe knot and favor either incomplete Si burning or an Alpha-rich freeze-out regime, probably close to the boundary. An explosive He burning regime is a possible alternative, although this hypothesis is in conflict with the main properties of this SNR.

ISM supernova remnants↗

Considerations for Femtosecond Laser Electronic Excitation Tagging in High-Speed Flows

Femtosecond laser electronic excitation tagging (FLEET) is an unseeded method for molecular tagging which offers valuable opportunities for measurement of high-speed (transonic, supersonic or hypersonic) flows. The unique nature of high-speed testing demands certain performance from FLEET such as satisfactory signal-to-noise ratio (SNR) at depressed static conditions (i.e., low temperatures, pressures and densities), wide dynamic range for velocity determination (especially single-shot), and measurements with acceptable accuracy and precision. This dissertation strives to evaluate FLEET in those regards and provide strategies to maximize the method's capabilities. A zero-dimensional kinetics model in nitrogen explains FLEET signal changes with pressure/density and/or temperature in terms of plasma-chemical reactions. Poorly known rate coefficients are tuned by comparing model output to measurements, with temporal agreement up to several hundred nanoseconds. Modeling reveals that initial signal peaks at reduced density because of slowed temporal evolution (and decay) of excited populations. Low temperatures enhance signal by enlarging cluster ion populations which contribute to excited species via electron-ion dissociative recombination. A purpose-built free jet facility provides experimental validation of the kinetics model and assesses FLEET velocimetry in low temperature and pressure/density conditions. Signal, lifetime, accuracy and precision results are obtained from unheated subsonic through Mach 4.0 operation of the facility, with best results noted. FLEET measurements of a sweeping jet (SWJ) actuator in compressible operation showcase its advantages in a highly unsteady jet containing subsonic through supersonic velocities. FLEET velocimetry is performed in the device's internal and external flow fields, with the latter compared to hot-wire anemometry. Internal measurements reveal the absence of shockwaves theorized to occur at high pressure ratios. Simultaneous qualitative measurements of compressible jet mixing are shown as a proof-of-concept. Overall, the work demonstrates that previous understanding of SWJ incompressible operation readily extends into the compressible realm. Practical aspects of performing FLEET velocimetry are detailed, along with strategies for improving measurement quality. Determination of a fundamental precision in nitrogen and air is attempted. Experiments show that increasing time delay and/or SNR improves velocimetry precision. A comparison of five camera systems indicates sensors with larger pixels capture higher SNR data and produce more precise results.

FLEET↗

The K Dwarf Advantage for Biosignatures on Directly Imaged Exoplanets

Oxygen and methane are considered to be the canonical biosignatures of modern Earth, and the simultaneous detection of these gases in a planetary atmosphere is an especially strong biosignature. However, these gases may be challenging to detect together in the planetary atmospheres because photochemical oxygen radicals destroy methane. Previous work has shown that the photochemical lifetime of methane in oxygenated atmospheres is longer around M dwarfs, but M dwarf planet habitability may be hindered by extreme stellar activity and evolution. Here, we use a 1-D photochemical-climate model to show that K dwarf stars also offer a longer photochemical lifetime of methane in the presence of oxygen compared to G dwarfs. For example, we show that a planet orbiting a K6V star can support about an order of magnitude more methane in its atmosphere compared to an equivalent planet orbiting a G2V star. In the reflected light spectra of worlds orbiting K dwarf stars, strong oxygen and methane features could be observed at visible and near-infrared wavelengths. Because K dwarfs are dimmer than G dwarfs, they offer a better planet-star contrast ratio, enhancing the signal-to-noise (SNR) possible in a given observation. For instance, a 50 hour observation of a planet at 7 pc with a 15-m telescope yields SNR = 9.2 near 1 µm for a planet orbiting a solar-type G2V star, and SNR = 20 for the same planet orbiting a K6V star. In particular, nearby mid-late K dwarfs such as 61 Cyg A/B, Epsilon Indi, Groombridge 1618, and HD 156026 may be excellent targets for future biosignature searches.

Giada N Arney↗

Linear Stokes Measurement of Thermal Targets using Compact LWIR Spectropolarimeter

The trade-o↵ between spectral resolution and instrument throughput is analyzed for a compact, uncooled, longwave infrared (LWIR) channeled spectropolarimeter (IRCSP). The IRCSP was developed as a part of the Submm Wave and InfraRed Polarimeters (SWIRP) project out of NASA’s Goddard Spaceflight Center. The IRCSP scientific objective targets measurements of AOLP and DOLP with 1-μm spectral resolution from 8.5 - 12.5 μm in a single snapshot. The geometry of the field stop determines the field of view (FOV) of the IRCSP. This work relates the spectral resolution, instrument throughput, and polarimetric accuracy of a spectro-polarimeter to the FOV. The accuracy of linear Stokes retrievals for low temperature thermal targets are predicted for varying FOV and measurement noise conditions. This work presents a method to quantify the achievable accuracy in AOLP and DOLP as a function of field stop dimensions and signal-to-noise ratio (SNR). While smaller field stops are shown to improve accuracy as the spectral resolution is increased, low SNR is the dominant source of error for the IRCSP prototype. For the IRCSP, a SNR of at least 80 is required to produce DOLP measurements with < 5% error for targets with DOLP < 0.2.

LWIR↗

Uncertainty Analysis of the GeoNEX Top-of-Atmospheric Reflectance Products Generated from the Third-Generation Geostationary Satellite Sensors

The GeoNEX (Geostationary-NASA Earth eXchange) Level-1G products consist of top-of-atmosphere (TOA) bi-directional reflectance factor (BRF) and brightness temperature generated with data streams from the latest geostationary (GEO) sensors including GOES-16/17 ABI, Himawari-8/9 AHI, and GK-2A AMI on a global tiled common grid (60oN-60o and 180oW-180oE) in geographic coordinates. With their 16 spectral bands, 0.01o/0.02o nadir spatial resolution, and 10-minute temporal resolutions, these products provide exciting opportunity to monitor Earth surface processes. However, the unique Sun-Target-Satellite geometry of geostationary sensors demands special attention in analyzing/interpreting these datasets. In this study we present a systematic analysis on the relationship between the radiometric uncertainties of the GeoNEX TOA reflectance and the corresponding solar/satellite zenith angles. We show that the signal-to-noise ratio (SNR) of the BRF are positively proportional to the square roots of the cosine of solar illuminating zenith angles. That is, the BRF data are noisier earlier in the morning or later in the afternoon than in the mid of the day. The cosine of satellite viewing zenith angles do not directly influence the SNR of the TOA BRF. However, they positively regulate the relative importance of the surface component in the TOA BRF. This means that variations in surface reflectance are more difficult to detect for pixels with larger view zenith angles, even when the SNR of the TOA BRF is the same. We are developing metrics to specify such illumination-view geometry related uncertainties in the GeoNEX L1G TOA BRF products so that this key information can be easily accessed by the user community.

Geostationary satellite↗

Effect of Electronic Shot Noise on Dynamic Measurements using Optical Techniques: Examples from Rayleigh Scattering and Unsteady PSP

Electronic shot noise is an unavoidable reality in all optical techniques that depend on measuring light intensity. For steady-state, time-averaged measurements the impact of shot noise can be easily reduced by increasing the exposure time, or by averaging over multiple-exposures. That is not the case for unsteady measurements, where time histories of light intensity variations need to be created either by high-speed photography (unsteady PSP) or via photoelectron counting (spectrally resolved Rayleigh scattering) over short time durations using a photo-multiplier tube (PMT) and photon counting electronics. Electronic shot noise introduces a fixed amount of random error, which can overwhelm the light intensity variation caused by turbulent fluctuations. Spectrum computed from such time series shows a fixed noise floor that is independent of the number of data points in the time series. For a fixed optical system, where the collected power of the luminescent light (uPSP), or the scattered light (Rayleigh) is fixed, one needs to resort to special techniques to obtain enough signal-to noise ratio (SNR). For the uPSP application it is shown that averaging of the adjacent pixels improves SNR; although this may lead to a sacrifice of spatial resolution. A second means is to increase the exposure time, which leads to a lowering of the frequency range. For the Rayleigh application, improvements of SNR can be achieved via two different cross-correlation based approaches. The first involves measuring the light intensity using two PMTs using short, contiguous gates; thereby, creating two time-series of data. The second one involves collecting one long time-series of data using one set of measurement device, followed by an odd-even splitting into two time series. When the two time-series are cross-correlated, and a power spectrum is calculated, a significant reduction in the shot noise floor can be achieved. Examples from measurements of density and velocity fluctuations spectra from two different Rayleigh setup are presented to demonstrate the process.

uPSP↗

Performance of Residual Carrier Array Feed Combining in Correlated Noise

An array feed combining system for the recovery of SNR loss due to antenna reflector deformation has been implemented and is currently being evaluated on the Jet Propulsion Laboratory 34 meter DSS-13 antenna. In this system, the defocused signal field captured by a focal plane array feed is recovered using real-time signal processing and signal combining techniques. The current signal processing and signal combining algorithms are optimum under the assumption that the white Gaussian noise processes in the received signals from different array elements are mutually uncorrelated. Experimental data at DSS-13 indicate that these noise processes are indeed mutually correlated. The main result of this paper is an analytical derivation of the actual SNR performance of the current suboptimal signal combining algorithm in this correlated noises environment. The analysis here shows that the combined signal SNR can either be improved or degraded depending on the relation between the array signal and noise correlation coefficient phases. Further performance improvement will require the development of signal combining methods that take into account the correlated noises.

Residual↗

GNSS-RO Deep Refraction Signals from Moist Marine Atmospheric Boundary Layer (MABL)

The marine atmospheric boundary layer (MABL) has a profound impact on sensible heat and moisture exchanges between the surface and the free troposphere. The goal of this study is to develop an alternative technique for retrieving MABL-specific humidity (q) using GNSS-RO data in deep-refracted signals. The GNSS-RO signal amplitude (i.e., signal-to-noise ratio or SNR) at the deep straight-line height (H(SL)) was been found to be strongly impacted by water vapor within the MABL. This study presents a statistical analysis to empirically relate the normalized SNR (S(RO)) at deep HSL to the MABL q at 950 hPa (~400 m). When compared to the ERA5 reanalysis data, a good linear q–S(RO) relationship is found with the deep H(SL) S(RO) data, but careful treatments of receiver noise, SNR normalization, and receiver orbital altitude are required. We attribute the good q–S(RO) correlation to the strong refraction from a uniform, horizontally stratiform and dynamically quiet MABL water vapor layer. Ducting and diffraction/interference by this layer help to enhance the S(RO) amplitude at deep H(SL). Potential MABL water vapor retrieval can be further developed to take advantage of a higher number of S(RO) measurements in the MABL compared to the Level-2 products. A better sampled diurnal variation of the MABL q is demonstrated with the S(RO) data over the Southeast Pacific (SEP) and the Northeast Pacific (NEP) regions, which appear to be consistent with the low cloud amount variations reported in previous studies.

diurnal variation↗

Exploring Mission Design for Imaging Spectroscopy Retrievals for Land and Aquatic Ecosystems

The retrieval algorithms used for optical remote sensing satellite data to estimate Earth's geophysical properties have specific requirements for spatial resolution, temporal revisit, spectral range and resolution, and instrument signal-to-noise ratio (SNR) performance to meet biogeoscience objectives. Studies to estimate surface properties from hyperspectral data use a range of algorithms sensitive to various sources of spectroscopic uncertainty, which are in turn influenced by mission architecture choices. Retrieval algorithms vary across scientific fields and may be more or less sensitive to mission architecture choices that affect spectral, spatial, or temporal resolutions and spectrometer SNR. We used representative remote sensing algorithms across terrestrial and aquatic study domains to inform aspects of mission design that are most important for impacting accuracy in each scientific area. We simulated the propagation of uncertainties in the retrieval process including the effects of different instrument configuration choices. We found that retrieval accuracy and information content degrade consistently at >10 nm spectral resolution, >30 m spatial resolution, and >8-day revisit. In these studies, the noise reduction associated with lower spatial resolution improved accuracy vis à vis high spatial resolution measurements. The interplay between spatial resolution, temporal revisit, and SNR can be quantitatively assessed for imaging spectroscopy missions and used to identify key components of algorithm performance and mission observing criteria.

A. M. Raiho↗

Remote sensing detection enhancement

Big Data in the area of Remote Sensing has been growing rapidly. Remote sensors are used in surveillance, security, traffic, environmental monitoring, and autonomous sensing. Real-time detection of small moving targets using a remote sensor is an ongoing, challenging problem. Since the object is located far away from the sensor, the object often appears too small. The object’s signal-to-noise-ratio (SNR) is often very low. Occurrences such as camera motion, moving backgrounds (e.g., rustling leaves), low contrast and resolution of foreground objects makes it difficult to segment out the targeted moving objects of interest. Due to the limited appearance of the target, it is tough to obtain the target’s characteristics such as its shape and texture. Without these characteristics, filtering out false detections can be a difficult task. Detecting these targets, would often require the detector to operate under a low detection threshold. However, lowering the detection threshold could lead to an increase of false alarms. In this paper, the author will introduce a new method that improves the probability to detect low SNR objects, while decreasing the number of false alarms as compared to using the traditional baseline detection technique.

47 OTHER INSTRUMENTATION↗

Improved reconstruction stability for chemical shift encoded hyperpolarized 13 C magnetic resonance spectroscopic imaging using k‐t spiral acquisitions

Purpose A multiecho, field of view (FOV)‐oversampled k‐t spiral acquisition and direct iterative decomposition of water and fat with echo asymmetry and least‐squares estimation reconstruction is demonstrated to improve the stability of hyperpolarized 13 C magnetic resonance spectroscopic imaging (MRSI) in the presence of signal ambiguities attributed to low‐SNR (signal‐to‐noise‐ratio) species, local uncertainties in metabolite peaks, and echo‐to‐echo signal inconsistencies. Theory k‐t spiral acquisitions redistribute readout points to be more densely spaced radially in k‐space by acquiring an FOV and matrix that are oversampled by η . These more densely spaced spiral turns constitute effective intraspiral echoes and can supplement conventional interspiral echoes to improve spectral separation and reduce spectral cross‐talk to better resolve 13 C‐labeled species for spectroscopic imaging. Methods Digital simulations and imaging phantom experiments were performed for a range of interspiral echo spacings and η using multiecho, k‐t spiral acquisitions. Image spectral cross‐talk artifacts were evaluated both qualitatively and quantitatively as the percent error in measured metabolite ratios. In vivo murine experiments evaluated the feasibility of multiecho, k‐t spiral [1‐ 13 C]pyruvate MRSI to reduce spectral cross‐talk for 3 scenarios of different expected reconstruction stability. Results Digital simulations and imaging phantom experiments both demonstrated reduced or comparable image spectral cross‐talk and percent errors in measured metabolite ratios with increasing η and better choices of echo spacings. In vivo images displayed markedly reduced spectral cross‐talk in lactate images acquired with η = 7 versus η = 1. Conclusion The precision of hyperpolarized 13 C metabolic imaging and quantification in the presence of low‐SNR species, local uncertainties in metabolite resonances, and echo‐to‐echo signal inconsistencies can be improved with the use of FOV‐oversampled k‐t spiral acquisitions.

Macdonald, Erin B.↗

A pulsed current-mode class-D low-voltage high-bandwidth power amplifier for portable NMR systems

Low-field NMR has seen growing interest in recent years, especially for portable applications. The lower homogeneity magnets used for portable applications require short RF pulses to ensure enough transmit bandwidth to excite the sample volume and also support short echo periods. Furthermore, the preferred use of a high-Q coil to improve signal-to-noise ratio (SNR) prolongs the pulse transients. Thus, at such low Larmor frequencies, the excitation pulse transients become comparable or longer than the pulse length, such that the transmit bandwidth begins to limit measurement SNR. This paper describes the design of a pulsed current-mode class-D power (PCMCD) transmitter that addresses this issue by generating high power in a tuned sample coil while maintaining short transients, thus resulting in high output bandwidth. The transmitter also uses a charge recycling mechanism to maximize power efficiency for RF train excitation, which also results in faster pulse repetition rate and reduces allowable echo time. In this work, experimental results from a small form-factor PCMCD transmitter are presented. This design generates a peak RF power of 240 W into a 9.16 µH coil at 4 MHz while operating off a single 12 V power supply. NMR measurement results using the transmitter are also described, showing minimum achievable echo time of 70 µs and 25 µs depending on the transmitter mode of operation.

47 OTHER INSTRUMENTATION↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Cobalt-Doped Tungsten Oxide Nanoparticles for Electrochemical Sensing and Detection of a Penicillin Antibiotic: Amoxicillin

A sensitive electrochemical sensor for the determination of antibacterial amoxicillin (AMXL) in pharmaceutical dosage and environmental samples was developed, since its residues were found in water, food, and biological samples to pose adverse health risks such as immune–allergic reactions and antimicrobial resistance. WO 3 -based sensors are reported to provide higher sensitivity, selectivity, and stability during the electrochemical reaction. Considering this, Co-doped WO 3 nanostructures were synthesized by the hydrothermal method yielding a mixture of nanoparticle and nanorod structures and applied to the assay of AMXL. Extensive characterizations were carried out by SEM, XRD, TEM, and XPS analysis that confirm the monoclinic crystal structure with a uniform Co distribution in the WO 3 lattice. The optimum doping amount of Co in the lattice is found to be 1.80 at %. The electrochemical performance of the Co-WO 3 /carbon paste electrode (CPE) was evaluated for the determination of AMXL under optimum conditions using cyclic voltammetry, electrochemical impedance spectroscopy, and square wave voltammetry. The Co-WO 3 /CPE showed two linear detection ranges at 0.01–0.1 μM with the linear regression I pa = 3.73 [AMXL] + 0.77 with R 2 = 0.96 and at 0.1 to 30.0 μM with the linear regression I pa = 3.76 [AMXL] + 0.69 with R 2 = 0.95. The limit of detection was 9.1 nM (SNR = 3), and the limit of quantification was 30.6 nM (SNR = 10). The sensitivities for lower and higher concentration ranges were 63.22 and 63.73 μA μM –1 cm –2 , respectively. Furthermore, Co-WO 3 /CPE showed high selectivity and anti-interference capabilities. In conclusion, the sensing and disposable Co-WO 3 /CPE sensor showed a great potential for AMXL analysis in spiked soil, water, and Amoxil tablet samples with desirable percentage recovery.

Shanbhag, Mahesh M. [KLE Technological University,↗

On the Estimation of In-Cloud Vertical Air Motion Using Radar Doppler Spectra

Measurements of in-cloud vertical air motion are key to quantitatively describe cloud dynamics and their role in cloud microphysics. Here, a retrieval technique for estimating the in-cloud vertical air motion using the upward edge of the radar Doppler spectrum is presented. An additional broadening correction factor that depends on the signal-to-noise ratio (SNR) is introduced. A variety of independent measurements are used to assess the performance of the new technique. The vertical air motion is unbiased with an uncertainty of 0.2 m s –1 for SNR <30. Here, the properties of in-cloud vertical air motion are investigated from 1 year of ground-based observations of warm marine boundary layer clouds. Clouds with higher LWP are characterized by stronger vertical air motions compared to those having lower LWP values.

42 ENGINEERING↗

Imaging atomic-scale chemistry from fused multi-modal electron microscopy

Efforts to map atomic-scale chemistry at low doses with minimal noise using electron microscopes are fundamentally limited by inelastic interactions. Here, fused multi-modal electron microscopy offers high signal-to-noise ratio (SNR) recovery of material chemistry at nano- and atomic-resolution by coupling correlated information encoded within both elastic scattering (high-angle annular dark-field (HAADF)) and inelastic spectroscopic signals (electron energy loss (EELS) or energy-dispersive x-ray (EDX)). By linking these simultaneously acquired signals, or modalities, the chemical distribution within nanomaterials can be imaged at significantly lower doses with existing detector hardware. In many cases, the dose requirements can be reduced by over one order of magnitude. This high SNR recovery of chemistry is tested against simulated and experimental atomic resolution data of heterogeneous nanomaterials.

36 MATERIALS SCIENCE↗