Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Smart Scattering Scanning Near-Field Optical Microscopy

Scattering scanning near-field optical microscopy (s-SNOM) provides spectroscopic imaging from molecular to quantum materials with few nanometer deep subdiffraction limited spatial resolution. However, in its conventional implementation s-SNOM is slow to effectively acquire a series of spatio-spectral images, especially with large fields of view. This problem is further exacerbated for weak resonance contrast or when using light sources with limited spectral irradiance. Indeed, the generally limited signal-to-noise ratio prevents sampling a weak signal at the Nyquist sampling rate. Here, we demonstrate how acquisition time and sampling rate can be significantly reduced by using compressed sampling, matrix completion, and adaptive random sampling, while maintaining or even enhancing the physical or chemical image content. We use fully sampled real data sets of molecular, biological, and quantum materials as ground-truth physical data and show how deep under-sampling with a corresponding reduction of acquisition time by 1 order of magnitude or more retains the core s-SNOM image information. We demonstrate that a sampling rate of up to 6× smaller than the Nyquist criterion can be applied, which would provide a 30-fold reduction in the data required under typical experimental conditions. Furthermore, our smart s-SNOM approach is generally applicable and provides systematic full spatio-spectral s-SNOM imaging with a large field of view at high spectral resolution and reduced acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Freeform Hybrid Manufacturing: Binderjet, Structured Light Scanning, Confocal Microscopy, and CNC Machining

This paper describes a hybrid manufacturing approach for silicon carbide (SiC) freeform surfaces using binder jet additive manufacturing (BJAM) to print the preform and machining to obtain the design geometry. Although additive manufacturing (AM) techniques such as BJAM allow for the fabrication of complex geometries, additional machining or grinding is often required to achieve the desired surface finish and shape. Hybrid manufacturing has been shown to provide an effective solution. However, hybrid manufacturing also has its own challenges, depending on the combination of processes. For example, when the subtractive and additive manufacturing steps are performed sequentially on separate systems, it is necessary to define a common coordinate system for part transfer. This can be difficult because AM preforms do not inherently contain features that can serve as datums. Additionally, it is important to confirm that the intended final geometry is contained within the AM preform. The approach described here addresses these challenges by using structured light scanning to create a stock model for machining. Results show that a freeform surface was machined with approximately 70 µm of maximum deviation from that which was planned.

Dvorak, Jake (ORCID:0000000260989944)↗

Qualitative assessment of uranium ore concentrates and related materials using scanning electron microscopy

Several studies have evaluated the morphology of uranium compounds produced under controlled conditions at the laboratory scale, but it is unclear whether the morphological characteristics of these materials persist in commercially produced uranium ore concentrates (UOCs). To assess the morphology in “real-world” UOCs, we qualitatively evaluated the morphological profile of secondary electron images from over 100 commercial UOCs using a previously published lexicon. We observe differences between samples with differing chemical composition and samples with similar chemical composition and differing provenance. Further, this work contextualizes morphology for commercially produced UOCs and will provide a basis for future machine learning efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Light-Dependent Impedance Spectra and Transient Photoconductivity in a Ruddlesden–Popper 2D Lead–Halide Perovskite Revealed by Electrical Scanned Probe Microscopy and Accompanying Theory

Electric force microscopy was used to record the light-dependent impedance spectrum and the probe transient photoconductivity of a film of butylammonium lead iodide, BA 2 PbI 4 , a 2D Ruddlesden–Popper perovskite semiconductor. The impedance spectrum of BA 2 PbI 4 showed modest changes as the illumination intensity was varied up to 1400 mW cm –2 , in contrast with the comparatively dramatic changes seen for 3D lead–halide perovskites under similar conditions. BA 2 PbI 4 ’s light-induced conductivity had a rise time and decay time of ~100 μs, 10 4 slower than expected from direct electron–hole recombination yet 10 5 faster than the conductivity-recovery times recently observed in 3D lead–halide perovskites and attributed to the relaxation of photogenerated vacancies. What sample properties are probed by electric force microscope measurements remains an open question. A Lagrangian-mechanics treatment of the electric force microscope experiment was recently introduced by Dwyer, Harrell, and Marohn which enabled the calculation of steady-state electric force microscope signals in terms of a complex sample impedance. Here this impedance treatment of the tip–sample interaction is extended, through the introduction of a time-dependent transfer function, to include time-resolved electrical scanned probe measurements. Here, it is shown that the signal in a phase-kick electric force microscope experiment, and therefore also the signal in a time-resolved electrostatic force microscope experiment, can be written explicitly in terms of the sample’s time-dependent resistance (i.e., conductivity).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adaptive Scalpel Scanning Probe Microscopy for Enhanced Volumetric Sensing in Tomographic Analysis

Controlling nanoscale tip‐induced material removal is crucial for achieving atomic‐level precision in tomographic sensing with atomic force microscopy (AFM). While advances have enabled volumetric probing of conductive features with nanometer accuracy in solid‐state devices, materials, and photovoltaics, limitations in spatial resolution and volumetric sensitivity persist. This work identifies and addresses in‐plane and vertical tip‐sample junction leakage as sources of parasitic contrast in tomographic AFM, hindering real‐space 3D reconstructions. Novel strategies are proposed to overcome these limitations. First, the contrast mechanisms analyzing nanosized conductive features are explored when confining current collection purely to in‐plane transport, thus allowing reconstruction with a reduction in the overestimation of the lateral dimensions. Furthermore, an adaptive tip‐sample biasing scheme is demonstrated for the mitigation of a class of artefacts induced by the high electric field inside the thin oxide when volumetrically reduced. This significantly enhances vertical sensitivity by approaching the intrinsic limits set by quantum tunneling processes, allowing detailed depth analysis in thin dielectrics. The effectiveness of these methods is showcased in tomographic reconstructions of conductive filaments in valence change memory, highlighting the potential for application in nanoelectronics devices and bulk materials and unlocking new limits for tomographic AFM.

36 MATERIALS SCIENCE↗

Twofold symmetry of proximity-induced superconductivity in Bi 2 Te 3 / Bi 2 Sr 2 CaCu 2 O 8 + δ heterostructures revealed by scanning tunneling microscopy

We observe proximity-induced superconductivity in in situ prepared heterostructures constructed by topological insulator Bi 2 Te 3 thin films and high-temperature cuprate superconductors Bi 2 Sr 2 CaCu 2 O 8+δ . The superconducting gap maximum is about 7.6 meV on the surface of Bi 2 Te 3 thin films with a thickness of two quintuple layers, and the gap value decreases with an increase in the film thickness. Moreover, the quasiparticle interference data show clear evidence of a twofold symmetric superconducting gap with gap minima along one pair of the principal crystalline axes of Bi 2 Te 3 . This gap form is consistent with the Δ 4y notation of the topological superconductivity proposed in such systems. Our results provide fruitful information on the possible topological superconductivity induced by the proximity effect in high-temperature superconducting cuprates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗