Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

GLM Observations of the Brightest Lightning in the Americas

Two years of Geostationary Lightning Mapper (GLM) science data are used to document the brightest lighting flashes observed on the Americas continent. The most radiant optical lightning emissions—termed “superbolts”—were first identified by the Vela satellite constellation in the 1970s (Turman, 1977) and are defined in terms of peak optical power. GLM is an integrating sensor that, instead, measures the total optical energy from a lightning pulse. Furthermore, while GLM might not correctly classify short-duration superbolts, its top lightning cases certainly fall in the superbolt category, and the wealth of GLM measurements over its stationary hemispheric field of view provide an unmatched sample of extraordinarily bright lightning. While radiant bolts in excess of 100× the optical energy of typical lightning are ubiquitous across the Americas and result from many types of lightning processes, we find the most radiant cases (>1,000×) are concentrated in the central United States and in the La Plata basin in South America. Coincident Earth Networks Global Lightning Network (ENGLN) observations reveal that these extremely bright emissions usually result from + CG strokes with high peak currents in long horizontal flashes outside of the convective core. Single cases of these megaflashes might produce multiple superbolts over their durations.

54 ENVIRONMENTAL SCIENCES↗

Multi‐Sensor Trajectory Reconstruction of the 24 April 2025 Alaska Fireball and Implications for Planetary Defense

On 24 April 2025 at 18:30:57 UTC, a bright daytime fireball over Southcentral Alaska was detected by 37 seismic stations, 16 single infrasound sensors, and four infrasound arrays, yielding 30 ballistic and multiple fragmentation arrivals. Here, the unprecedented density of seismoacoustic coverage enabled detailed reconstruction of the event using acoustic signals, with fragmentation source locations further guiding the identification of Doppler weather radar signatures of a meteorite fall. Incorporation of a radar-derived terminal point yielded a final trajectory solution, which agreed closely with an independent optical trajectory solution from video analysis. The reconstructed entry parameters from seismoacoustic analysis indicate a velocity of 25.3 km/s, an entry angle of 19°, and an energy release of ∼38 t TNT equivalent. Assuming a chondritic composition, the pre-entry object diameter was ∼0.7 m. Using orbital parameters from the optical solution, we estimate meteoroid composition as most likely an L-type ordinary chondrite. The event occurred in the sub-Arctic, where space-based optical systems face challenges in detection, demonstrating the critical role of dense ground-based seismoacoustic networks in characterizing high-latitude atmospheric entries. This uniquely well-recorded event demonstrates the capability of dense seismoacoustic networks to constrain bolide trajectories, energetics, and fragmentation, with radar and optical data providing critical confirmation and complementary perspectives. These results bridge the methodological gap between planetary-defense monitoring of natural impactors and space-traffic analyses of artificial reentries, illustrating how multi-sensor integration can deliver calibration-grade trajectories even for unpredicted events.

Fireball↗

Development and flight-testing of modular autonomous cultivation systems for biological plastics upcycling aboard the ISS

Cultivation of microorganisms in space has enormous potential to enable in-situ resource utilization (ISRU) Here, we develop an autonomous payload with fully programmable serial passaging and sample preservation, termed the Modular Open Biological Platform (MOBP), and flight-test the MOBP aboard the International Space Station (ISS) by conducting enzymatic and microbial plastics upcycling experiments. The MOBP is a compact, modular bioreactor system that allows for sustained microbial growth via automated media transfers, such as those for sample collection and storage for terrestrial analyses, and precise data monitoring from integrated sensors. The MOBP was flight-tested with two experiments designed to evaluate biological upcycling of the plastic poly(ethylene terephthalate) (PET). The bioproduct βKA can be polymerized into a nylon-6,6 analog with improved properties for use in the production of a variety of materials. We posit the MOBP will aid in democratizing the execution of synthetic biology in spaceflight towards enabling ISRU.

09 BIOMASS FUELS↗

Embedding thermocouples in SS316 with laser powder bed fusion

Recent advances in manufacturing technologies have enabled the fabrication of complex geometries for a wide range of applications, including the energy, aerospace, and civil sectors. The ability to integrate sensors at critical locations within these complex components during the manufacturing process could benefit process monitoring and control by reducing reliance on models to relate surface measurements to internal phenomena. This study investigated embedding thermocouples in a SS316 matrix using laser powder bed fusion. Under optimal processing conditions, embedded thermocouples were characterized post-building, finding good bonding to the matrix with no melt pool penetration to the sensing elements. Futher, the embedded thermocouple performed similarly to an identical non-embedded thermocouple during thermal testing to 500 °C with only a slight difference in response time, which was attributed to the differences in mass and the associated thermal time constants.

image analysis↗

MO-FG-303-02: BEST IN PHYSICS (THERAPY): Cherenkov Emission Dosimetry: Feasibility for Electron Radiotherapy

Purpose: To investigate from first principles, corroborated by Monte Carlo simulations and experimental measurements, the feasibility of developing a relative Cherenkov emission (CE) dosimetry protocol for electron beam radiotherapy. Methods: Monte Carlo (MC) simulations of mono-energetic electrons incident on water were carried out in Geant4. Percent depth Cherenkov emission (PDCE) and dose (PDD) distributions were scored for incidence energies of 4, 6, 9, 12, 15, and 18 MeV. PDCE-to-PDD analytical conversion models were developed from least-squares data fits generated for PDD as a function of PDCE at the same depth and at different depths. Experimental techniques for validation of these models are examined. Results: Same-depth PDD versus PDCE data fits indicate that although the relationship is linear to first order (correlation r > 0.9 for all energies), it is much more accurately approximated by separate linear and quadratic models for the build-up and drop-off regions, respectively (r > 0.999), which is theoretically underpinned. To understand the source of this relationship and its basis for developing robust conversion models, an approximate quadratic first-principles model was derived and found in agreement with MC/measured data (20% deviation at worst). Conversely, data fits of PDD versus different-depth PDCE unveiled a depth-invariant effective point of measurement of 1.5–2.1 mm downstream with 4–18 MeV incidence, respectively (r > 0.999 in the drop-off region). We present an analytical first-principles justification for this shift. This method led to errors of <1% in drop-off region PDD (<2% for PDD<20% with 4 MeV incidence) and <0.2 mm in practical range prediction. Conclusion: We present robust quantitative prediction models, derived from first-principles and supported by simulation and measurement, for relative dose from Cherenkov emission by high-energy electrons. This constitutes a major step towards development of protocols for routine clinical quality assurance as well as real-time in vivo Cherenkov dosimetry in radiotherapy. The authors acknowledge partial support by Fonds de recherche du Quebec - Nature et technologies (FRQNT), CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council of Canada (NSERC), CREATE Integrated Sensor Systems grant of NSERC, the Canadian Institutes of Health Research (CIHR), and NSERC.

60 APPLIED LIFE SCIENCES↗

Turbulence Measurements from Compliant Moorings. Part I: Motion Characterization

Abstract High-fidelity measurements of turbulence in the ocean have long been challenging to collect, in particular in the middle of the water column. In response, a measurement technique has been developed to deploy an acoustic Doppler velocimeter (ADV) to midwater locations on a compliant mooring. A variety of instrumentation platforms have been deployed as part of this work with a range of dynamic motion characteristics. The platforms discussed herein include the streamlined StableMoor buoy (SMB), the Tidal Turbulence Mooring (TTM) system based on a conventional 0.9-m spherical buoy, and a 100-lb sounding weight suspended from the stern of a research vessel. The ADV head motion is computed from inertial motion sensors integrated into an ADV, and the spectra of these signals are investigated to quantify the motion of each platform. The SMB with a single ADV head mounted on the nose provided the most stable platform for the measurement of tidal turbulence in the inertial subrange for flow speeds exceeding 1.0 m s−1. The modification of the SMB with a transverse wing configuration for multiple ADVs showed a similar frequency response to the nose configuration in the horizontal plane but with large contamination in the vertical direction as a result of platform roll. While the ADV motion on the TTM was significant in the horizontal directions, the vertical motion of this configuration was the most stable of all configurations tested. The sounding weight measurements showed the greatest motion at the ADV head but are likely to be influenced by both prop-wash and vessel motion.

16 TIDAL AND WAVE POWER↗

Sodar Data from Oyster Bay at Winyah Bay National Estuarine Research Reserve in South Carolina

The SecondWind Triton® is a SODAR (SOnic Detection and Ranging) sonic wind profiler (Triton® sodar) system capable of profiling the wind characteristics up to 200m above the instrument. SODAR systems transmit acoustic chirps into the atmosphere and measure the backscattered signal returned to the device. The primary source of acoustic scattering is variations in air temperature, which cause changes in the refractive index of sound. By measuring the Doppler-shifted frequency of these returned signals, the Triton® can calculate the wind’s speed and direction for the volume of air above the instrument, measured at ten fixed heights, known as station heights. The Triton® is specifically designed for the purpose of wind energy resource assessment as it can remotely capture wind data at heights above ground where wind turbine rotors operate. The measurements made include horizontal wind speed and direction, vertical wind speed, and turbulence. Other integrated sensors provide time and location via GPS, barometric pressure, humidity, and the tilt of the instrument. The study area is located east of Georgetown, South Carolina in North Inlet - Winyah Bay National Estuarine Research Reserve. The monitoring period for data in this report begins 5/14/2009 9:30:00 AM EST and ends 8/2/2010 11:40:00 AM EST.

17 WIND ENERGY↗

BLEMS (award #DE-EE0004019) Final Report

This project focused on the development and testing of a non-intrusive “bolt-on” solution called the Building Level Energy Management System (BLEMS) which reduces day-to-day electric energy consumption by at least 20% while maintaining or improving occupant comfort. BLEMS learns occupants’ energy usage behavior, and comfort preferences, as well as building system behavior and uses this information to reduce energy consumption and related greenhouse gas emissions, while simultaneously meeting occupants’ comfort and building usage needs (i.e., day-to-day energy usage goals, demand response energy usage levels, etc.). In BLEMS, humans and building systems and devices interact ubiquitously in real time through an integrated sensor and control system for reduced building electricity consumption. The solution enables bidirectional communication between building systems and occupants, obtains occupant input on comfort level preferences, and operates the building based on measured system response, occupant feedback, and predicted occupancy. Although designed to be used in any building, we focused on commercial buildings as they are a major consumer of HVAC power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intrinsic Fiber Optic Chemical Sensors for Subsurface Detection of CO 2

Intelligent Optical Systems, Inc. has developed distributed intrinsic fiber optic sensors to directly quantify the concentration of dissolved or gas-phase CO 2 for leak detection or plume migration in carbon capture and sequestration (CCS). The capability of the sensor for highly sensitive detection of CO 2 in the pressure and temperature range of 15 to 2,000 psi and 25°C to 175°C was demonstrated, as was the capability of operating in highly corrosive and contaminated environments such as those often found in CO 2 injection sites. The novel sensor system was for the first time demonstrated deployed in a deep well, detecting multiple CO 2 releases, in real time, at varying depths. Early CO 2 release detection, by means of a sensor cable integrating multiple sensor segments, was demonstrated, as was the capability of quantifying the leak. The novel fiber optic sensor system exhibits capabilities not achieved by any other monitoring technology. This project represents a breakthrough in monitoring capabilities for CCS applications.

54 ENVIRONMENTAL SCIENCES↗

Safe Detection System for Hydrogen Leaks

Hydrogen is an "environmentally friendly" fuel for future transportation and other applications, since it produces only pure ("distilled") water when it is consumed. Thus, hydrogen-powered vehicles are beginning to proliferate, with the total number of such vehicles expected to rise to nearly 100,000 within the next few years. However, hydrogen is also an odorless, colorless, highly flammable gas. Because of this, there is an important need for hydrogen safety monitors that can warn of hazardous conditions in vehicles, storage facilities, and hydrogen production plants. To address this need, IOS has developed a unique intrinsically safe optical hydrogen sensing technology, and has embodied it in detector systems specifically developed for safety applications. The challenge of using light to detect a colorless substance was met by creating chemically-sensitized optical materials whose color changes in the presence of hydrogen. This reversible reaction provides a sensitive, reliable, way of detecting hydrogen and measuring its concentration using light from low-cost LEDs. Hydrogen sensors based on this material were developed in three completely different optical formats: point sensors ("optrodes"), integrated optic sensors ("optical chips"), and optical fibers ("distributed sensors") whose entire length responds to hydrogen. After comparing performance, cost, time-to-market, and relative market need for these sensor types, the project focused on designing a compact optrode-based single-point hydrogen safety monitor. The project ended with the fabrication of fifteen prototype units, and the selection of two specific markets: fuel cell enclosure monitoring, and refueling/storage safety. Final testing and development of control software for these markets await future support.

99 GENERAL AND MISCELLANEOUS↗

Surrogate Model of Flexible Research Platform EnergyPlus Models to Enable Sensitivity Analysis

This letter report describes the surrogate models developed from the EnergyPlus model of Oak Ridge National Laboratory’s Flexible Research Platform. Two data-driven black-box models were developed, and the outputs of the surrogate models were compared with the EnergyPlus model. The two models developed are a multilayer perceptron deep learning model, and a long short-term memory (LSTM) neural network model. The three factors for selecting the black-box models are scalability, computation time, and accuracy. A total of 107 input variables were the dominant variables in determining the outputs of building energy consumptions and thermal comfort. A total of 54 output variables were identified as the prediction targets, including the system- and zone-level outputs. The large set of the simulation cases were generated by integrating sensor errors into an emulator based on EnergyPlus and Python EMS, which includes advanced control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. The surrogate models were developed based on a set of large-scale simulation runs (i.e., 4,000 runs) on a cloud platform. The comparison analysis shows that the two black-box models had good accuracy for predicting new outputs for sensitivity analysis using the root mean square error metric. As a next step, the developed surrogate models will be used to perform sensitivity analysis for different sensor impacts (e.g., sensor types, sensor locations).

42 ENGINEERING↗

PRIMED for the Future: Purposing Raw Intake for Machine Learning-Enabled Detection (Final Report)

The COVID-19 pandemic demonstrated how a novel, elusive, and diffuse biological threat can engender uncertainty and misinformation, and it underscored the need for flexible analytical modalities agnostic to the identity of biological material. Yet even before the pandemic, recognition of the limitations of the current, list-based approach, which focuses on known pathogens and biotoxins, and of the importance of agent-agnostic biodetection was growing within the biosecurity community. In a 2018 report on “Biodefense in the Age of Synthetic Biology,” for example, the National Academy of Sciences stated that “an overreliance on the Select Agent List is a systematic weakness affecting many aspects of the United States’ current biodefense mitigation capability”. More recently, a group of biodefense researchers proposed the identification and adoption of “bioagent-agnostic signatures (BASs)” as a way of detecting and characterizing not only existing agents but also novel ones, an approach they believe will “enable a more flexible and resilient biodefense posture”. Indeed, the future of biodetection requires us to begin developing novel analytics that can identify anomalies and/or characteristics that indicate a potential threat, whether known or unknown, without looking for a specific signature that has been identified previously. To assess potential threats more rapidly, it is critical to develop agnostic artificial intelligence (AI)/machine learning (ML) systems that can be employed for real-time assessment of the nature and source of a perturbation. Such systems should be multi scale and multi-dimensional, integrating sensor data from a range of biological, chemical, and physical application spaces. Emerging deep learning (DL) models demonstrate exceptional promise for identification of discriminatory features within multi-dimensional datasets. DL models have the capacity to recognize and encode highly complex patterns in a wide range of input data modalities, including images, text, and biological/chemical/physical spectra. As such, they can execute a wide range of assessments and determinations that have traditionally required a human operator. The promise of advances in DL is apparent in the realm of human health and medicine. DL models have been validated for evaluating a variety of clinical threats to human health in a range of contexts, including infection and cancer, and they demonstrated improved performance in predicting stroke relative to human neurologists in some categories of data. Continuously evolving advances in AI/ML are expected to support more efficient evaluation of raw sequence, spectroscopy, and spectrometry data. For instance, recent advances and deployment of large language models (LLM) such as Generative Pre training Transformer (GPT) and Bidirectional Encoder Representations from Transformers (BERT) have already motivated application of these models for biological function prediction. As frameworks such as LLMs become larger and more complex in their representations, their capacity to serve as pre-trained models that can be fine-tuned for biological/biodetection purposes will similarly be amplified. While existing and emerging AI/ML have found broad applicability and use cases in the clinical sciences, development for environmental evaluation and biodetection has been limited. Functionalizing such capabilities for this purpose requires an understanding of the existing technical landscape and how the respective tools and algorithms are currently being employed. This landscape awareness then allows an assessment of the current practical capabilities of existing models and the anticipated requirements and development efforts that will be needed to adapt available algorithms for biodetection applications relevant to DHS. Leveraging expertise in biodetection, ML, and operational biodetection, the effort described in this report is comprised of a systematic landscape assessment (Subtask 2.1), comparative evaluation (Subtask 2.2), and formulation of a value proposition (Subtask 2.3) for the prospect of ML-enabled, agnostic biodetection from raw, or minimally-processed, datasets.

59 BASIC BIOLOGICAL SCIENCES↗

Drifting Hydrophone Development - Spar2

Oregon State University (OSU) is requesting technical assistance for design configuration, assembly, and bench testing of 4 state-of-the-art drifting hydrophone systems per OSU technical specification and aligned with IEC TS 62600 -40 Acoustic Characterization of Marine Energy Converters. The technical assistance objective of this request will bring online another state-of-the-art drifting hydrophone technology where there is limited availability for these systems for use at marine energy projects. The objectives of the technical assistance will significantly advance OSU’s existing drifting hydrophone technology and enable them to provide important state of the art hydrophone sensors and platforms for monitoring devices in support of marine energy testing activities across the industry. Leveraging the Pacific Northwest National Laboratory’s (PNNL) TEAMER facility expertise will provide significant improvements to this new drifting hydrophone technology with additional added value through hardware and sensor integration, wireless communication, commercial pressure housing modifications, bench testing and calibration.

42 ENGINEERING↗

PRIMED for the Future: Purposing Raw Intake for Machine Learning-Enabled Detection

The COVID-19 pandemic demonstrated how a novel, elusive, and diffuse biological threat can engender uncertainty and misinformation, and it underscored the need for flexible analytical modalities agnostic to the identity of biological material. Yet even before the pandemic recognition of the limitations of the current, list-based approach, which focuses on known pathogens and biotoxins, and of the importance of agent-agnostic biodetection, was growing within the biosecurity community. In a 2018 report on “Biodefense in the Age of Synthetic Biology,” for example, the National Academy of Sciences stated that “an overreliance on the Select Agent List is a systematic weakness affecting many aspects of the United States’ current biodefense mitigation capability." More recently, a group of biodefense researchers proposed the identification and adoption of “bioagent-agnostic signatures (BASs)” as a way of detecting and characterizing not only existing agents but also novel ones, an approach they believe will “enable a more flexible and resilient biodefense posture." Indeed, the future of biodetection requires us to begin developing novel analytics that can identify anomalies and/or characteristics that indicate a potential threat, whether known or unknown, without looking for a specific signature that has been identified previously. To assess potential threats more rapidly, it is critical to develop agnostic artificial intelligence (AI)/machine learning (ML) systems that can be employed for real-time assessment of the nature and source of a perturbation. Such systems should be multiscale and multi-dimensional, integrating sensor data from a range of biological, chemical, and physical application spaces. Emerging deep learning (DL) models demonstrate exceptional promise for identification of discriminatory features within multi-dimensional datasets. DL models have the capacity to recognize and encode highly complex patterns in a wide range of input data modalities, including images, text, and biological/chemical/physical spectra. As such, they can execute a wide range of assessments and determinations that have traditionally required a human operator.

59 BASIC BIOLOGICAL SCIENCES↗

Wide Bandgap Generation (WBGen): Developing the Future Wide Bandgap Power Electronics Engineering Workforce

This Final Technical Report (FTR) summarizes the work conducted at the Center for Power Electronics Systems (CPES) under the Wide-Bandgap Generation (WBGen) fellowship and traineeship program established by the Advanced Manufacturing and Technologies Office (AMMTO) of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy (EERE) at Virginia Tech, which had as main objective to train the next generation of U.S. citizen power engineers with wide-bandgap (WBG) power semiconductor expertise, with the intent to aid in fulfilling the future workforce needs in this field. The latter was deemed of strategic importance given the fast-paced growth observed—and predicted—in the demand of this technical expertise, whose practitioners have become the enablers and executioners of the electrification transformation process that not just the U.S., but the whole world, is currently undergoing as it seeks for more effective and efficient ways to use energy. As such, the WBGen program set forth to achieve its educational goals, which in addition sought to broaden the range of WBG-based power electronics by conducting research and development on high-efficiency grid apparatus and high-efficiency electrical power systems, and to also enhance the power engineering curriculum by formalizing WBG-oriented design procedures replacing existent yet now obsolete design procedures developed for Silicon (Si) based power electronics. This effort led CPES to spearhead the development of a new major within The Bradley Electrical and Computer Engineering (ECE) Department at Virginia Tech, namely Electronic Power and Energy Systems (EPES), which coalesced power electronics and power systems courses to provide undergraduate students with a strong formation in the power engineering field, while creating a pipeline of graduate students that could pursue the WBG-based curriculum and conduct research at CPES. In all, in what is considered a true success, eight of the twenty WBGen fellows that graduated program were recruited from the ECE department undergraduate cohort. The traineeship emphasized as well, from its beginning, the partnership with industry and national laboratories, which took advantage of the successful industry consortium at CPES that has historically been formed by 80–90 power and energy companies working in close collaboration with the center. This gave WBGen fellows the accessibility and possibility to conduct internships at partner facilities during the summer months, focused solely on the evaluation, testing, and adoption of WBG devices, which were many times tightly related to their respective research work and plans. In addition, WBGen fellows conducted their main research work within the confines of research programs at CPES conducted with these industry partners, providing them with a unique opportunity to develop not just their technical expertise—while advancing their knowledge, but to also learn and practice a slew of skills needed for their professional growth. As such, the fellows tackled a variety of WBG-related research topics, from device reliability and capability aspects as well as packaging and integration, encompassing the use of advanced materials and new structures, current sharing challenges, and insulation systems, to advanced gate-drivers with integrated sensors and protection mechanisms and active current- and voltage-based control, to optimized layouts seeking to maximize the switching and power processing performance of these devices, to power processing solutions adopting Gallium-Nitride (GaN) and Silicon-Carbide (SiC) power semiconductors for a variety of applications; including radiation-hardened converters for space dc distribution systems, direct three-phase ac-to-ac power converters for aerospace systems, dc-ac inverters for automotive traction drives, high-frequency isolated dc-dc battery chargers also for heavy transportation systems, and medium-voltage dc-dc and dc-ac converters for distribution systems and future power grids. The WBGen program ultimately graduated a total of 20 power engineers, all experts on WBG-based power electronics, awarding 18 M.S. and 2 PhD degrees in the process. These fellows, all U.S. citizens, allowed CPES to increase the number of citizens students to 33 % at the peak of the program, as the traineeship made possible the recruitment of talent with more attractive graduate research assistantship (GRA) contracts. Unfortunately, the present U.S. citizen enrollment at CPES has declined back to historic levels—approximately 10 %, as the regular GRA rates are not competitive enough when compared with entry-level industry jobs. In all, WBGen fellows published a total of 7 peer-reviewed journal articles, 44 papers at international technical conferences, made 42 presentations at international technical conferences, and filed 4 invention disclosures and patent applications, which have since then been granted by the U.S. Patent and Trademark Office (USPTO). Their contribution to CPES, Virginia Tech, the United States, and the world, has been significant, and continues to yield results thanks to the exemplary career that the fellows have initiated at many of the partners of the program, which include Wolfspeed, Raytheon Technologies, Infineon, Lockheed Martin, Dominion Energy, Northrop Grumman, Rivian, Aerospace Corporation, Sandia National Laboratory, National Renewable Energy Laboratory, John Hopkins University, and Virginia Tech.

14 SOLAR ENERGY↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microreactor Program Technology Maturation MACS system reports

This submission contains several reports associated with the DOE Microreactor Program Technology Maturation MACS system. These include milestone reports: M3AT-24IN0804031-Optimized MACS architecture M3AT-24IN0804033-Light and temp sensor integration M4AT-23IN0804055-Update Microreactor Automated Control System (MACS) hardware based on input from demonstration M2AT-23IN0804054-Demonstrate actuation of control system using Microreactor Automated Control System (MACS)

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗