Search NASA⌕ Search

SEARCH · Search NASA

Results for “beamline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Implementation of a laser–neutron pump–probe capability for inelastic neutron scattering

Knowledge about nonequilibrium dynamics in spin systems is of great importance to both fundamental science and technological applications. Inelastic neutron scattering (INS) is an indispensable tool to study spin excitations in complex magnetic materials. However, conventional INS spectrometers currently only perform steady-state measurements and probe averaged properties over many collision events between spin excitations in thermodynamic equilibrium, while the exact picture of re-equilibration of these excitations remains unknown. In this paper, we report on the design and implementation of a time-resolved laser–neutron pump–probe capability at hybrid spectrometer (beamline 14-B) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. This capability allows us to excite out-of-equilibrium magnons with a nanosecond pulsed laser source and probe the resulting dynamics using INS. Here, we discussed technical aspects to implement such a capability in a neutron beamline, including choices of suitable neutron instrumentation and material systems, laser excitation scheme, experimental configurations, and relevant firmware and software development to allow for time-synchronized pump–probe measurements. We demonstrated that the laser-induced nonequilibrium structure factor is able to be resolved by INS in a quantum magnet. In conclusion, the method developed in this work will provide SNS with advanced capabilities for performing out-of-equilibrium measurements, opening up an entirely new research direction to study out-of-equilibrium phenomena using neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simple wire-coil resistive heater for high temperature radial x-ray diffraction in a diamond anvil cell

Diamond anvil cells are commonly used at synchrotron x-ray diffraction beamlines to study structural and thermoelastic properties of materials at high pressures. In a radial geometry, where the x-ray probe is oriented perpendicular to the axis of force, the deformation and strength of materials can be measured in situ. Because the anelastic and failure properties of materials depend strongly on temperature, many applications would benefit from the ability to measure high pressure radial diffraction in elevated and accurately controlled thermal environments. Previous work to introduce high temperature to radial diamond anvil cells has been largely limited to laser heating, with relatively scant efforts to resistively heat the sample. Here, we report a relatively straightforward adaptation of a simple wire coil heater, with in situ high-temperature radial diffraction performed on tungsten carbide up to 573 K at beamline 12.2.2 of the Advanced Light Source. In conclusion, the results demonstrate that the differential stress supported by WC decreases with increasing temperature: the differential stress on the basal (001) and pyramidal (101) planes decreased 6.6% and 5.5%, respectively, while the (100) plane only saw a 2.7% decrease, in agreement with previous studies.

Diamond anvil cells↗

4D beam matrix reconstruction in particle accelerators

Transverse beam parameters in particle accelerators are commonly described using the Twiss parameters, which are experimentally accessible yet inherently limited because they neglect correlations between different transverse coordinates. Such correlations frequently arise from uncompensated cathode magnetic fields or misaligned focusing quadrupoles, affecting beam quality and accelerator performance. To address this limitation, we propose and validate a novel diagnostic method for the complete four-dimensional (4D) transverse beam matrix. Our method involves passing the beam through a beamline comprising both conventional and skew quadrupole magnets, followed by downstream measurements of the resulting two-dimensional (2D) beam profiles. These measurements represent distinct 2D projections of the underlying 4D transverse phase–space distribution. By systematically varying quadrupole strengths, multiple independent projections of the beam phase space are obtained. We reconstruct the original 4D beam matrix from these measured projections using an optimization-based least-square fit, providing fast and robust reconstruction regardless of the specific beamline configuration. Through extensive numerical simulations and realistic particle-tracking studies, we demonstrate the diagnostic’s accuracy, robustness, and capability to achieve reconstruction uncertainties smaller than measurement errors, particularly when employing sufficient numbers of quadrupole scans. This method presents a powerful and flexible approach for comprehensive beam characterization and accelerator tuning.

43 PARTICLE ACCELERATORS↗

A high-efficiency cryogenic neutron spin flipper for IMAGINE-X at the high flux isotope reactor

The Laue neutron macromolecular crystallography beamline, IMAGINE, at the High Flux Isotope Reactor (HFIR) is undergoing a major upgrade to incorporate the dynamic nuclear polarization (DNP) technique. Upon completion, the new IMAGINE-X instrument is expected to enhance the signal-to-noise ratio of the diffraction data by an order of magnitude. To take full advantage of the benefits of DNP, both a highly polarized neutron beam and a high-efficiency neutron spin flipper are required. We have developed a compact cryogenic spin flipper utilizing the Meissner effect in high-Tc yttrium–barium–copper–oxide superconducting films. The flipper has been successfully tested at two HFIR neutron development beamlines, Larmor and Poplar, with neutron wavelengths of 5.3 and 2.4 Å respectively. At Larmor, a flipping efficiency of 0.995 ± 0.004 was achieved for 5.3 Å neutrons, and at Poplar, efficiency of up to 0.9987 ± 0.0004 was obtained for 2.4 Å neutrons. Both tests demonstrated the flipper’s excellent performance and suitability for integration into IMAGINE-X.

Fu, Sichao [Oak Ridge National Laboratory (ORNL), ↗

Early-Stage Radiation Safety Analysis for the Spallation Neutron Source Second Target Station Bunker Operations

The Second Target Station project at Oak Ridge National Laboratory will develop a cold neutron source to meet growing experimental needs. This paper describes calculations of the residual dose rates associated with the monolith shield plug and the beamline bunker, two key conventional operations and radiation safety features. While neutron production is active, the instrument hall outside the bunker must be generally accessible with dose rates of less than 0.25 mrem/h. When neutron production is halted, the bunker must be accessible for hands-on maintenance operations. Further, these two requirements form the cause for the assessments reported herein of residual dose rates caused by the monolith shield plug and residual dose rates in the bunker. The monolith shield plug was shown to not produce significant dose rates inside the bunker after a 20-year lifetime, and the residual dose rates inside the bunker for the case of an operating beamline were shown to reasonably allow for hands-on maintenance. These calculations are based on preliminary design models of the relevant systems. Additionally, an example showing the significance of considering neutron supermirror physics in transport calculations that track nuclide production and destruction rates to produce gamma sources for residual dose rate calculations is included. The example shows that if neutron supermirror physics is not considered, dose rate fields may be significantly underpredicted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multimodal, Multidimensional, and Multiscale X-ray Imaging at the National Synchrotron Light Source II

Over the last couple of decades, the synchrotron radiation research community has witnessed tremendous advancement in the field of x-ray imaging and microscopy. Continuing enhancement of the light sources’ brightness, advances in x-ray focusing optics, incorporation of precision instruments, and development of innovative imaging techniques are some of the leading contributors for the rapid progress. New imaging and microscopy beamlines, such as the ones at the National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science user facility located at DOE’s Brookhaven National Laboratory, are capable of performing more sophisticated and complicated measurements than ever before, either on their own or used together as a suite of tools. These sophisticated and complex measurements exhibit attributes for multimodal, multidimensional, and multiscale imaging. Recent popularity of these methods is strongly driven by the current trends in materials characterizations, where researchers desire to map out hierarchical materials structure over a large range of length scales, to understand structure-property correlation, to quantify materials structures in 3D, and/or to perform operando or in situ experiments. It is important to emphasize that “materials” under investigation are not only synthesized materials but also the natural materials. In this article, we describe multimodal, multidimensional and multiscale x-ray imaging capabilities of the NSLS-II beamlines and how these methods are used to tackle complex scientific problems.

47 OTHER INSTRUMENTATION↗

Applications of “Synchrotron Radiation Workshop” Code

The “Synchrotron Radiation Workshop” (SRW) computer code was started in the group of Insertion Devices of the European Synchrotron Radiation Facility in 1997. The idea behind it was to combine in one software library electrodynamics methods for calculating electric fields (and derived characteristics) of synchrotron radiation (SR) generated by relativistic electrons moving in magnetic fields of nearly arbitrary configuration with wave-optics methods for simulating propagation of radiation through optical elements of beamlines. Further, the use of this general approach was initially driven by applications in electron beam diagnostics using SR. However, with time it started to be used for more complicated beamlines of synchrotron light sources, and the use of the code for these applications continues to increase, with the new light sources offering brighter and more coherent x ray beams for wide ranges of experiments in different areas of science.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New developments in structure-property and amorphous materials research at the upgraded 16-BM-B Paris-Edinburgh press station at HPCAT

Beamline 16-BM-B of the High-Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source (APS) provides a Paris-Edinburgh press program to probe the structure and properties of crystalline and amorphous materials up to 12 GPa at room temperature or 7 GPa at 2000°C. During the recent APS upgrade, 16-BM-B undertook major improvements to its instrumentation and measurement techniques. The upgrade includes the addition of a 1.2 m horizontal “condenser” mirror and a new variable-sized collimation system, the combination of which decreases the acquisition time for energy dispersive X-ray diffraction measurements by a factor of 10 when compared to pre-upgrade measurements. The addition of a new Ge energy-sensitive detector and DANTE (XGLab) digital pulse processor allows for processing the increased diffraction counts with minimal deadtime. In addition to upgraded beamline components, new techniques are being developed for eventual release to the user community, including electrical resistivity and tomography measurements.

APS upgrade↗

When x-rays alter the course of your experiments

The continuing increase in the brilliance of synchrotron radiation beamlines allows for many new and exciting experiments that were impossible before the present generation of synchrotron radiation sources came on line. However, the exposure to such intense beams also tests the limits of what samples can endure. Whilst the effects of radiation induced damage in a static experiment often can easily be recognized by changes in the diffraction or spectroscopy curves, the influence of radiation on chemical or physical processes, where one expects curves to change, is less often recognized and can be misinterpreted as a 'real' result instead of as a 'radiation influenced result'. This is especially a concern in time-resolved materials science experiments using techniques as powder diffraction, small angle scattering and x-ray absorption spectroscopy. In this work, the effects of radiation (5–50 keV) on some time-resolved processes in different types of materials and in different physical states are discussed. We show that such effects are not limited to soft matter and biology but rather can be found across the whole spectrum of materials research, over a large range of radiation doses and is not limited to very high brilliance beamlines.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High power density soft x-ray GaAs photodiodes with tailored spectral response

GaAs photodiode arrays have been designed for non-destructive monitoring of x-ray beam position in soft coherent beamline front ends in synchrotron light sources. A shallow p-on-n junction was employed to reduce the device photocurrent density to optimize the operation with beam power densities up to 20 W mm -2 , mainly coming from hard x-rays. With this approach, the photocurrent is primarily defined by the excess carriers generated by low-energy x-ray photons absorbed near the detector surface. The p–n junction structures were grown by molecular beam epitaxy and processed into 64-element linear photodiode arrays. The devices were characterized first in the visible range with a high-power Ar-ion laser and then tested in the soft and hard x-ray regions up to 10 keV at two beamlines of the National Synchrotron Light Source II. The responsivity was measured to be 0.16 A W -1 at 0.7 keV and 0.05 A W -1 at 6 keV in agreement with modeling. At higher x-ray energies the measured responsivity was lower than predicted in the framework of the carrier diffusion model; a possible explanation is discussed.

36 MATERIALS SCIENCE↗

Developments in SRW Code and Sirepo Framework Supporting Simulation of Time-Dependent Coherent X-ray Scattering Experiments

Physical optics simulations for beamlines and experiments are essential for the effective use of synchrotron light source facilities such as NSLS-II at BNL. The SRW software package supports such source-to-detector simulations for coherent X-ray scattering and imaging experiments through its Python interface and Sirepo browser-based graphical user interface. This allows one to define custom sample models, assess the feasibility of an experiment, and estimate most appropriate beamline settings before using valuable beamtime. We discuss the recent use of general-purpose GPU resources and coherent mode decomposition algorithms in SRW to accelerate physical optics simulations with partially coherent X-rays. To illustrate these new capabilities, we describe simulations of typical time series of partially coherent scattering images used in X-ray Photon Correlation Spectroscopy (XPCS) experiments; aiming to characterize the nanoscale dynamics of a disordered sample, representing a solution of nanoparticles undergoing Brownian diffusion.

36 MATERIALS SCIENCE↗

Neutrino identification with scintillation light in MicroBooNE

MicroBooNE is a neutrino experiment which employs a liquid argon (LAr) time projection chamber (TPC) to record neutrino interactions from Fermilab's neutrino beamlines. The experiment's primary objective is to study low-energy νe interactions from the Booster Neutrino Beamline (BNB). Located on the surface, the detector is affected by a continuous rate of cosmic-rays. This leads to one neutrino interaction for every 104 cosmic rays observed in the TPC, making it difficult to isolate neutrino interactions in the detector using charge alone. MicroBooNE's trigger makes use of prompt scintillation light and plays an essential role in both performing strong background rejection and significantly reducing data-rates. Furthermore, a series of novel techniques relying on scintillation light are used to isolate beam-induced activity. This document briefly presents MicroBooNE's scintillation-light based trigger and novel Flash-Matching pattern recognition techniques for cosmic-rejection. This work serves as the foundation of neutrino analyses in LArTPC detectors and is therefore of interest to the broader short- and long-baseline neutrino programs being launched at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Liquid Argon In A Testbeam (LArIAT) Experiment

The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 0∼30–0140 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design, construction, and commissioning of the KATRIN experiment

The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. More than 15 years ago, we published a technical design report (TDR) to describe the hardware design and requirements to achieve our sensitivity goal of 0.2 eV at 90%C.L. on the neutrino mass. Since then there has been considerable progress, culminating in the publication of first neutrino mass results with the entire beamline operating. In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over long times,and present details on their respective commissioning campaigns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of rf-induced temporal jitter in ultrafast electron diffraction

A significant contribution to the temporal resolution of an ultrafast electron diffraction (UED) instrument is arrival time jitter caused by amplitude and phase variation of radio-frequency (rf) cavities. In this paper, we present a semianalytical approach for calculating rf-induced temporal jitter from klystron and rf cavity parameters. Our approach allows fast estimation of temporal jitter for MeV-UED beamlines and can serve as a virtual timing tool when shot-to-shot measurements of rf amplitude and phase jitters are available. A simulation study for the SLAC MeV-UED instrument is presented, and the temporal resolution of several beamline configurations is compared.

47 OTHER INSTRUMENTATION↗

PyMDA : microcrystal data assembly using Python

The recent developments at microdiffraction X-ray beamlines are making microcrystals of macromolecules appealing subjects for routine structural analysis. Microcrystal diffraction data collected at synchrotron microdiffraction beamlines may be radiation damaged with incomplete data per microcrystal and with unit-cell variations. A multi-stage data assembly method has previously been designed for microcrystal synchrotron crystallography. Here the strategy has been implemented as a Python program for microcrystal data assembly ( PyMDA ). PyMDA optimizes microcrystal data quality including weak anomalous signals through iterative crystal and frame rejections. Beyond microcrystals, PyMDA may be applicable for assembling data sets from larger crystals for improved data quality.

36 MATERIALS SCIENCE↗

In situ temperature profile measurements with high-energy X-rays as a probe of optical floating zone crystal growth environment

The ability of optical floating zone (OFZ) furnaces to rapidly produce large single crystals of complex emerging materials has had a transformative effect on many scientific fields that require samples of this type. However, the crystal growth process within the OFZ furnace is not well understood owing to the challenges involved in monitoring the high-temperature crystal growth process. Novel beamline-compatible optical furnaces that approximate the inhomogeneous growth environment within an OFZ furnace have been fabricated and tested in high-energy synchrotron beamlines. In this paper, it is demonstrated that temperature profiles can be effectively extracted from powder diffraction data collected on polycrystalline ceramic rods heated at their tip. Furthermore, these measured temperature profiles can be accurately reproduced using a heat-transfer model that accounts for solid-state thermal conduction, partial sample lamp power absorption, convective air cooling and radiative cooling, allowing key thermal parameters such as thermal conductivity to be extracted from experimental data.

36 MATERIALS SCIENCE↗

Bragg Spot Finder (BSF): a new machine-learning-aided approach to deal with spot finding for rapidly filtering diffraction pattern images

Macromolecular crystallography contributes significantly to understanding diseases and, more importantly, how to treat them by providing atomic resolution 3D structures of proteins. This is achieved by collecting X-ray diffraction images of protein crystals from important biological pathways. Spotfinders are used to detect the presence of crystals with usable data, and the spots from such crystals are the primary data used to solve the relevant structures. Having fast and accurate spot finding is essential, but recent advances in synchrotron beamlines used to generate X-ray diffraction images have brought us to the limits of what the best existing spotfinders can do. This bottleneck must be removed so spotfinder software can keep pace with the X-ray beamline hardware improvements and be able to see the weak or diffuse spots required to solve the most challenging problems encountered when working with diffraction images. In this paper, we first present Bragg Spot Detection (BSD), a large benchmark Bragg spot image dataset that contains 304 images with more than 66 000 spots. We then discuss the open source extensible U-Net-based spotfinder Bragg Spot Finder (BSF), with image pre-processing, a U-Net segmentation backbone, and post-processing that includes artifact removal and watershed segmentation. Finally, we perform experiments on the BSD benchmark and obtain results that are (in terms of accuracy) comparable to or better than those obtained with two popular spotfinder software packages ( Dozor and DIALS ), demonstrating that this is an appropriate framework to support future extensions and improvements.

36 MATERIALS SCIENCE↗