Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

TU-CD-304-09: Feasibility Study for Thermoplastic Mask Set Up Monitoring Using Force Sensing Resistor (FSR) Sensor

Purpose: To improve the setup accuracy of thermoplastic mask, we developed a new monitoring method based on force sensing technology and evaluated its feasibility. Methods: The thermoplastic mask setup monitoring system consists of a force sensing resistor sensor unit, a signal transport device, a control PC and an in-house software. The system is designed to monitor pressure variation between the mask and patient in real time. It also provides a warning to the user when there is a possibility of movement. A preliminary study was performed to evaluate the reliability of the sensor unit and developed monitoring system with a head phantom. Then, a simulation study with volunteers was conducted to evaluate the feasibility of the monitoring system. Note that the sensor unit can have multiple end-sensors and every end-sensor was confirmed to be within 2% reliability in pressure reading through a screening test. Results: To evaluate the reproducibility of the proposed monitoring system in practice, we simulated a mask setup with the head phantom. FRS sensors were attached on the face of the head phantom and pressure was monitored. For 3 repeated mask setups on the phantom, the variation of the pressure was less than 3% (only 1% larger than 2% potential uncertainty confirmed in the screening test). In the volunteer study, we intended to verify that the system could detect patient movements within the mask. Thus, volunteers were asked to turn their head or lift their chin. The system was able to detect movements effectively, confirming the clinical feasibility of the monitoring system developed. Conclusion: Through the proposed setup monitoring method, it is possible to monitor patient motion inside a mask in real time, which has never been possible with most commonly used systems using non-radiographic technology such as infrared camera system and surface imaging system. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

Evaluation of S190A radiometric exposure test data

The S190A preflight radiometric exposure test data generated as part of preflight and system test of KM-002 Sequence 29 on flight camera S/N 002 was analyzed. The analysis was to determine camera system transmission using available data which included: (1) films exposed to a calibrated light source subject; (2) filter transmission data; (3) calibrated light source data; (4) density vs. log10 exposure curves for the films; and (5) spectral sensitometric data for the films. The procedure used is outlined, and includes the data and a transmission matrix as a function of field position for nine measured points on each station-film-filter-aperture-shutter speed combination.

Lockwood, H. E.↗

Necessity to adapt land use and land cover classification systems to readily accept radar data

A hierarchial, four level, standardized system for classifying land use/land cover primarily from remote-sensor data (USGS system) is described. The USGS system was developed for nonmicrowave imaging sensors such as camera systems and line scanners. The USGS system is not compatible with the land use/land cover classifications at different levels that can be made from radar imagery, and particularly from synthetic-aperture radar (SAR) imagery. The use of radar imagery for classifying land use/land cover at different levels is discussed, and a possible revision of the USGS system to more readily accept land use/land cover classifications from radar imagery is proposed.

Drake, B.↗

FPGA Coprocessor Design for an Onboard Multi-Angle Spectro-Polarimetric Imager

A multi-angle spectro-polarimetric imager (MSPI) is an advanced camera system currently under development at JPL for possible future consideration on a satellite-based Aerosol-Cloud-Environ - ment (ACE) interaction study. The light in the optical system is subjected to a complex modulation designed to make the overall system robust against many instrumental artifacts that have plagued such measurements in the past. This scheme involves two photoelastic modulators that are beating in a carefully selected pattern against each other. In order to properly sample this modulation pattern, each of the proposed nine cameras in the system needs to read out its imager array about 1,000 times per second. The onboard processing required to compress this data involves least-squares fits (LSFs) of Bessel functions to data from every pixel in realtime, thus requiring an onboard computing system with advanced data processing capabilities in excess of those commonly available for space flight. As a potential solution to meet the MSPI onboard processing requirements, an LSF algorithm was developed on the Xilinx Virtex-4FX60 field programmable gate array (FPGA). In addition to configurable hardware capability, this FPGA includes Power -PC405 microprocessors, which together enable a combination hardware/ software processing system. A laboratory demonstration was carried out based on a hardware/ software co-designed processing architecture that includes hardware-based data collection and least-squares fitting (computationally), and softwarebased transcendental function computation (algorithmically complex) on the FPGA. Initial results showed that these calculations can be handled using a combination of the Virtex- 4TM Power-PC core and the hardware fabric.

Pingree, Paula J.↗

R and DE Robotic Sensor Intern Team: Remote 3D Mapping Sensor Suite

The primary goal of the sensor suite is to provide an internal 3D map of the HCAEX tunnel. When looking for a sensor that would provide XYZ point cloud data for mapping the decision was between a stereo camera, a 3D Lidar, or a 2D Lidar that would need to be spun around. The issues with the stereo camera were that it does not have a large field-of-view and that its depth information was not nearly as accurate as even the baseline Lidars. The selection between Lidars is detailed. The Hokuyo UTM-30LX-EW shown provides a 270 deg. FOV with high accuracy and resolution while the largest FOV on a 3D Lidar is 40 deg.. This was the reason a 2D Lidar was chosen over the 3D Lidar. Even though the 2D Lidar requires additional components and software to generate a 3D map, its FOV advantage is too great given that the HCAEX tunnel is a relatively confined space. The rotating planar scan from the 2D Lidar can be stitched into a 3D scan as shown in the graphic below. Along with XYZ data, the Lidar provides return intensity data in color which can be used to distinguish between different materials within the tunnel. To provide visual feedback a camera system needed to be identified. The common solution for this is a high resolution camera with a small FOV mounted on a pan-tilt system. But, given the critical nature of the visual feedback we looked into solutions without the need for moving parts. Two panospheric cameras give a FOV large enough to get a full 360 deg. view.. Camera color data (RGB) can also be combined with the 3D mapping data from the Lidar and overlaid on the map to give the user the ability to see inside the entire length of the tunnel as if they were inside. Situational awareness is required for the crawler in the tunnel in order for it to be able to register the 3D scans to create a final map. For this we procured a Microstrain 3DM-GX5-25 Inertial Measurement Unit (IMU). To perform the Lidar rotation we have two servos driving the pan and tilt. The servo controls and most data processing will be performed via an onboard computer. The sensor components are to be packaged together using 3D printed mounts into a standalone unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Document Monitor

The charters of Freedom Monitoring System will periodically assess the physical condition of the U.S. Constitution, Declaration of Independence and Bill of Rights. Although protected in helium filled glass cases, the documents are subject to damage from light vibration and humidity. The photometer is a CCD detector used as the electronic film for the camera system's scanning camera which mechanically scans the document line by line and acquires a series of images, each representing a one square inch portion of the document. Perkin-Elmer Corporation's photometer is capable of detecting changes in contrast, shape or other indicators of degradation with 5 to 10 times the sensitivity of the human eye. A Vicom image processing computer receives the data from the photometer stores it and manipulates it, allowing comparison of electronic images over time to detect changes.

Source record↗

Fizeau interferometer system for fast high resolution studies of spectral line shapes

A monochromator/Fizeau interferometer/intensified CCD camera system is described that was developed for the measurement of the shape of spectral lines that are rapidly time varying. The most important operating parameter that determines the performance of the instrument is the size of the entrance aperture as this determines both the light throughput and the effective interferometer wavelength resolution. This paper discusses, both theoretically and experimentally, the effect of the finite source area on the instrumental resolution to assist in optimizing the choice of this parameter. A second effect that often produces a practical limit to the quality of the spectra is drift of the interferometer plates. Measurements of the shapes of spectral lines of ions and atoms ejected from the cathode spot of continuous and pulsed cathodic arcs are presented to demonstrate the utility of this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photogrammetry of Apollo 15 photography, part C

In the Apollo 15 mission, a mapping camera system and a 61 cm optical bar, high resolution panoramic camera, as well as a laser altimeter were used. The panoramic camera is described, having several distortion sources, such as cylindrical shape of the negative film surface, the scanning action of the lens, the image motion compensator, and the spacecraft motion. Film products were processed on a specifically designed analytical plotter.

Wu, S. S. C.↗

Intensified charge coupled devices for ultra low light level imaging

Development of a sensor incorporating a CCD and photocathode for operation in the electron bombarded mode in both a magnetic and an electrostatic focussed, gated configuration is described. Initial format size is 100 x 160 pixels with eventual growth to 400 x 400 pixels. The sensor is part of a digital camera system which includes the low level video conditioning electronics, a camera controller, a high speed buffer memory, and digital recording and display electronics. The memory uses CMOS/SOS and has a capacity of 1.6 Mbits with operating rates of 48 Mbits/sec. Individual frames are co-added to provide wide dynamic range and photometric precision better than 1%. A 4-bit video quantization is used to increase the photon counting detection rate before coincidence losses become serious.

Sobieski, S.↗

The mosaics of Mars: As seen by the Viking Lander cameras

The mosaics and derivative products produced from many individual high resolution images acquired by the Viking Lander Camera Systems are described: A morning and afternoon mosaic for both cameras at the Lander 1 Chryse Planitia site, and a morning, noon, and afternoon camera pair at Utopia Planitia, the Lander 11 site. The derived products include special geometric projections of the mosaic data sets, polar stereographic (donut), stereoscopic, and orthographic. Contour maps and vertical profiles of the topography were overlaid on the mosaics from which they were derived. Sets of stereo pairs were extracted and enlarged from stereoscopic projections of the mosaics.

Levinthal, E. C.↗

Breast Biopsy System

Charge Coupled Devices (CCDs) are high technology silicon chips that connect light directly into electronic or digital images, which can be manipulated or enhanced by computers. When Goddard Space Flight Center (GSFC) scientists realized that existing CCD technology could not meet scientific requirements for the Hubble Space Telescope Imagining Spectrograph, GSFC contracted with Scientific Imaging Technologies, Inc. (SITe) to develop an advanced CCD. SITe then applied many of the NASA-driven enhancements to the manufacture of CCDs for digital mammography. The resulting device images breast tissue more clearly and efficiently. The LORAD Stereo Guide Breast Biopsy system incorporates SITe's CCD as part of a digital camera system that is replacing surgical biopsy in many cases. Known as stereotactic needle biopsy, it is performed under local anesthesia with a needle and saves women time, pain, scarring, radiation exposure and money.

Source record↗

The HEROES Balloon-Borne Hard X-Ray Telescope

The High Energy Replicated Optics to Explore the Sun (HEROES) payload flew on a balloon from Ft. Sumner, NM, September 21-22, 2013. HEROES is sensitive from about 20-75 keV and comprises 8 optics modules (HPD approximately 33" as flown), each consisting of 13-14 nickel replicated optics shells and 8 matching Xenon-filled position-sensitive proportional counter detectors (dE/E=0.05 @ 60 keV). Our targets included the Sun, the Crab Nebula and pulsar and the black hole binary GRS 1915+105. HEROES was pointed using a day/night star camera system for astrophysical observations and a newly developed Solar Aspect System for solar observations (with a shutter protecting the star camera.) We have successfully detected the Crab Nebula. Analyses for GRS 1915+105 and the Sun are ongoing. In this presentation, I will describe the HEROES mission, the data analysis pipeline and calibrations, preliminary results, and plans for follow-on missions.

Wilson-Hodge, C.↗

NASA Tech Briefs, December 2007

Topics include: Ka-Band TWT High-Efficiency Power Combiner for High-Rate Data Transmission; Reusable, Extensible High-Level Data-Distribution Concept; Processing Satellite Imagery To Detect Waste Tire Piles; Monitoring by Use of Clusters of Sensor-Data Vectors; Circuit and Method for Communication Over DC Power Line; Switched Band-Pass Filters for Adaptive Transceivers; Noncoherent DTTLs for Symbol Synchronization; High-Voltage Power Supply With Fast Rise and Fall Times; Waveguide Calibrator for Multi-Element Probe Calibration; Four-Way Ka-Band Power Combiner; Loss-of-Control-Inhibitor Systems for Aircraft; Improved Underwater Excitation-Emission Matrix Fluorometer; Metrology Camera System Using Two-Color Interferometry; Design and Fabrication of High-Efficiency CMOS/CCD Imagers; Foam Core Shielding for Spacecraft CHEM-Based Self-Deploying Planetary Storage Tanks Sequestration of Single-Walled Carbon Nanotubes in a Polymer PPC750 Performance Monitor Application-Program-Installer Builder Using Visual Odometry to Estimate Position and Attitude Design and Data Management System Simple, Script-Based Science Processing Archive Automated Rocket Propulsion Test Management Online Remote Sensing Interface Fusing Image Data for Calculating Position of an Object Implementation of a Point Algorithm for Real-Time Convex Optimization Handling Input and Output for COAMPS Modeling and Grid Generation of Iced Airfoils Automated Identification of Nucleotide Sequences Balloon Design Software Rocket Science 101 Interactive Educational Program Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators Benchtop Detection of Proteins Recombinant Collagenlike Proteins Remote Sensing of Parasitic Nematodes in Plants Direct Coupling From WGM Resonator Disks to Photodetectors Using Digital Radiography To Image Liquid Nitrogen in Voids Multiple-Parameter, Low-False-Alarm Fire-Detection Systems Mosaic-Detector-Based Fluorescence Spectral Imager Plasmoid Thruster for High Specific-Impulse Propulsion Analysis Method for Quantifying Vehicle Design Goals Improved Tracking of Targets by Cameras on a Mars Rover Sample Caching Subsystem Multistage Passive Cooler for Spaceborne Instruments GVIPS Models and Software Stowable Energy-Absorbing Rocker-Bogie Suspensions

Source record↗

Optical system case studies

The purpose of this document is to detail the effect of various optical and camera system parameters for two different classes of surveillance imaging scenarios. We will take into account the effects of expected atmospheric turbulence and demonstrate where image enhancement techniques such as speckle imaging[1] can help. In the scenarios considered here, primary factors that determine the limiting resolutions are the range to target, wavelength, focal length, camera pixel size, and aperture size. Depending on the weather, imaging geometry, and the nature of the terrain below the imaging path, the atmospheric effects will vary. For the first scenario, we are interested in studying system parameters for imaging over shorter ranges from 2 to 8 km from very low slant angles over land or water. For the second scenario, we are interested in studying system parameters for imaging from 10 km to 60 km from low slant angles over land.

42 ENGINEERING↗

SU-E-J-17: A Study of Accelerator-Induced Cerenkov Radiation as a Beam Diagnostic and Dosimetry Tool

Purpose: To investigate accelerator-induced Cerenkov radiation imaging as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams in a water phantom was imaged using a camera system comprised of a high-sensitivity thermoelectrically-cooled CCD camera coupled to a large aperture (f/0.75) objective lens with 16:1 magnification. This large format lens allows a significant amount of the available Cerenkov light to be collected and focused onto the CCD camera to form the image. Preliminary images, obtained with 6 MV photon beams, used an unshielded camera mounted horizontally with the beam normal to the water surface, and confirmed the detection of Cerenkov radiation. Several improvements were subsequently made including the addition of radiation shielding around the camera, and altering of the beam and camera angles to give a more favorable geometry for Cerenkov light collection. A detailed study was then undertaken over a range of electron and photon beam energies and dose rates to investigate the possibility of using this technique for beam diagnostics and dosimetry. Results: A series of images were obtained at a fixed dose rate over a range of electron energies from 6 to 20 MeV. The location of maximum intensity was found to vary linearly with the energy of the beam. A linear relationship was also found between the light observed from a fixed point on the central axis and the dose rate for both photon and electron beams. Conclusion: We have found that the analysis of images of beam-induced Cerenkov light in a water phantom has potential for use as a beam diagnostic and medical dosimetry tool. Our future goals include the calibration of the light output in terms of radiation dose and development of a tomographic system for 3D Cerenkov imaging in water phantoms and other media.

07 ISOTOPE AND RADIATION SOURCES↗

Shuttle sortie electro-optical instruments study

A study to determine the feasibility of adapting existing electro-optical instruments (designed and sucessfully used for ground operations) for use on a shuttle sortie flight and to perform satisfactorily in the space environment is considered. The suitability of these two instruments (a custom made image intensifier camera system and an off-the-shelf secondary electron conduction television camera) to support a barium ion cloud experiment was studied for two different modes of spacelab operation - within the pressurized module and on the pallet.

Source record↗

Video Target Tracking and Ranging System

Proposed target tracking and ranging system uses two automatic video target trackers to keep two TV cameras trained on object being tracked. Microcomputer calculates range and range-rate information by triangulation. Input data for calculation are position coordinates of two cameras and pan and tilt aiming angles of two cameras. System is useful for target ranging at distances up to about 1,000 feet (300 m) in such applications as vehicle collision avoidance, traffic monitoring and surveillance. Also substitutes for short-range radar in situations where radar signal can not be tolerated.

Freedman, L. A.↗