Search NASA⌕ Search

SEARCH · Search NASA

Results for “circuit model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Electrochemical Study Of Corrosion Of Painted Steel

Resistor-and-capacitor circuit models represent evolving properties of coated specimens. Electrochemical experiments on corrosion of painted 4130 steel described in report. Study part of general development of ac-impedance method for measurement of properties of coated metals.

Mendrek, M. H.↗

Analysis of radiometer calibration effects with TOUCHSTONE

The microwave circuit analysis program TOUCHSTONE is used to study two effects of importance in radiometer calibration. The two effects are impedance mismatches at the antenna-air and cold load-air interfaces and dissipatives losses, which radiate thermal noise into the system. The results predicted by TOUCHSTONE are shown to be in very close agreement with earlier results obtained by purely analytical methods. The techniques used in establishing the circuit models and in processing the resulting data are described in detail.

Stanley, William D.↗

High reliability megawatt transformer/rectifier

The goal of the two phase program is to develop the technology and design and fabricate ultralightweight high reliability DC to DC converters for space power applications. The converters will operate from a 5000 V dc source and deliver 1 MW of power at 100 kV dc. The power weight density goal is 0.1 kg/kW. The cycle to cycle voltage stability goals was + or - 1 percent RMS. The converter is to operate at an ambient temperature of -40 C with 16 minute power pulses and one hour off time. The uniqueness of the design in Phase 1 resided in the dc switching array which operates the converter at 20 kHz using Hollotron plasma switches along with a specially designed low loss, low leakage inductance and a light weight high voltage transformer. This approach reduced considerably the number of components in the converter thereby increasing the system reliability. To achieve an optimum transformer for this application, the design uses four 25 kV secondary windings to produce the 100 kV dc output, thus reducing the transformer leakage inductance, and the ac voltage stresses. A specially designed insulation system improves the high voltage dielectric withstanding ability and reduces the insulation path thickness thereby reducing the component weight. Tradeoff studies and tests conducted on scaled-down model circuits and using representative coil insulation paths have verified the calculated transformer wave shape parameters and the insulation system safety. In Phase 1 of the program a converter design approach was developed and a preliminary transformer design was completed. A fault control circuit was designed and a thermal profile of the converter was also developed.

Zwass, Samuel↗

High-frequency resonant-tunneling oscillators

Advances in high-frequency resonant-tunneling-diode (RTD) oscillators are described. Oscillations up to a frequency of 420 GHz have been achieved in the GaAs/AlAs system. Recent results obtained with In0.53Ga0.47As/AlAs and InAs/AlSb RTDs show a greatly increased power density and indicate the potential for fundamental oscillations up to about 1 THz. These results are consistent with a lumped-element equivalent circuit model of the RTD. The model shows that the maximum oscillation frequency of the GaAs/AlAs RTDs is limited primarily by series resistance, and that the power density is limited by low peak-to-valley current ratio.

Brown, E. R.↗

Equivalent Circuits For AC-Impedance Analysis Of Corrosion

Report presents investigation of equivalent circuits for ac-impedance analysis of corrosion. Impedance between specimen and electrolyte measured as function of frequency. Data used to characterize corrosion electrochemical system in terms of equivalent circuit. Eleven resistor/capacitor equivalent-circuit models were analyzed.

Danford, M. D.↗

Frequency response measurements in battery electrodes

Electrical impedance spectroscopy was used to investigate the behavior of porous zinc, silver, cadmium, and nickel electrodes. State of charge could be correlated with impedance data for all but the nickel electrodes. State of health was correlated with impedance data for two AgZn cells, one apparently good and the other bad. The impedance data was fit to equivalent circuit models.

Thomas, Daniel L.↗

Testing and analyses of electrochemical cells using frequency response

The feasibility of electrochemical impedance spectroscopy as a method for analyzing battery state of health and state of charge was investigated. Porous silver, zinc, nickel, and cadmium electrodes as well as silver/zinc cells were studied. State of charge could be correlated with impedance data for all but the nickel electrodes. State of health was correlated with impedance data for two silver/zinc cells, one apparently good and the other dead. The experimental data were fit to equivalent circuit models.

Norton, O. A., Jr.↗

Theoretical and experimental investigation of a rectenna element for microwave power transmission

A microstrip measurement system has been designed to analyze packaged GaAs Schottky barrier diodes under small and large signal conditions. The nonlinear equivalent circuit parameters of the diode are determined using a small signal test method that analyzes the diode's scattering parameters at various bias levels. The experimental results of a 2.45 GHz diode are verified using a nonlinear circuit simulation program based on a multireflection algorithm. A 35 GHz rectenna has been built using a microstrip patch antenna and Ka-band mixer diode. The measured efficiency was 29 percent at 120 mW input power. A frequency selective surface is designed using an equivalent circuit model to reduce the second harmonic radiations for a 2.45 GHz rectenna. Theoretical results are found to be in fairly good agreement with experiments.

Mcspadden, James O.↗

Electrochemical impedance spectroscopy of lithium-titanium disulfide rechargeable cells

The two-terminal alternating current impedance of Li/TiS2 rechargeable cells was studied as a function of frequency, state-of-charge, and extended cycling. Analysis based on a plausible equivalent circuit model for the Li/TiS2 cell leads to evaluation of kinetic parameters for the various physicochemical processes occurring at the electrode/electrolyte interfaces. To investigate the causes of cell degradation during extended cycling, the parameters evaluated for cells cycled 5 times were compared with the parameters of cells cycled over 600 times. The findings are that the combined ohmic resistance of the electrolyte and electrodes suffers a tenfold increase after extended cycling, while the charge-transfer resistance and diffusional impedance at the TiS2/electrolyte interface are not significantIy affected. The results reflect the morphological change and increase in area of the anode due to cycling. The study also shows that overdischarge of a cathode-limited cell causes a decrease in the diffusion coefficient of the lithium ion in the cathode.

Narayanan, S. R.↗

Electrical characteristics of spark generators for automotive ignition

This paper reports the results of an extensive program of measurements on 11 ignition systems differing widely in type. The results serve primarily to give representative data on the electric and magnetic constants of such systems, and on the secondary voltage produced by them under various conditions of speed, timing, shunting resistance, etc. They also serve to confirm certain of the theoretical formulas which have been proposed to connect the performance of such systems with their electrical constants, and to indicate the extent to which certain simplified model circuits duplicate the performance of the actual apparatus.

Brode, R B↗

Computational Investigation of Experimental Interaction Impedance Obtained by Perturbation for Helical Traveling-Wave Tube Structures

Conventional methods used to measure the cold-test interaction impedance of helical slow-wave structures involve perturbing a helical circuit with a cylindrical dielectric rod placed on the central axis of the circuit. It has been shown that the difference in resonant frequency or axial phase shift between the perturbed and unperturbed circuits can be related to the interaction impedance. However, because of the complex configuration of the helical circuit, deriving this relationship involves-several approximations. With the advent of accurate three- dimensional helical circuit models, these standard approximations can be fully investigated. This paper addresses the most prominent approximations made in the analysis for measured interaction impedance by Lagerstrom and investigates their accuracy using the three-dimensional simulation code MAFIA. It is shown that a more accurate value of interaction impedance can be obtained by using three-dimensional computational methods rather than performing costly and time consuming experimental cold-test measurements.

Kory, Carol L.↗

Computational Investigation of Experimental Interaction Impedance Obtained by Perturbation for Helical Traveling Wave Tube Structures

Conventional methods used to measure the cold- test interaction impedance of helical slow-wave structures involve perturbing a helical circuit with a cylindrical dielectric rod placed on the central axis of the circuit It has been shown that the difference in resonant frequency or axial phase shift between the perturbed and unperturbed circuits can be related to the interaction impedance. However, because of the complex configuration of the helical circuit, deriving this relationship involves several approximations. With the advent of accurate three-dimensional (3-D) helical circuit models, these standard approximations can be fully Investigated. This paper addresses the most prominent approximations made in the analysis for measured interaction impedance by Lagerstrom and investigates their accuracy using the 3-D simulation code MAFIA. It is shown that a more accurate value of interaction impedance can be obtained by using 3-D computational methods rather than performing costly and time consuming experimental cold-test measurements.

Kory, Carol L.↗

Computational Investigation of Experimental Interaction Impedance Obtained by Perturbation for Helical Traveling-Wave Tube Structures

Conventional methods used to measure the cold-test interaction impedance of helical slow-wave structures involve perturbing a helical circuit with a cylindrical dielectric rod placed on the central axis of the circuit. It has been shown that the difference in resonant frequency or axial phase shift between the perturbed and unperturbed circuits can be related to the interaction impedance. However, because of the complex configuration of the helical circuit, deriving this relationship involves several approximations. With the advent of accurate three-dimensional (3-D) helical circuit models, these standard approximations can be fully investigated. This paper addresses the most prominent approximations made in the analysis for measured interaction impedance by Lagerstrom and investigates their accuracy using the 3-D simulation code MAFIA. It is shown that a more accurate value of interaction impedance can be obtained by using 3-D computational methods rather than performing costly and time consuming experimental cold-test measurements.

Kory, Carol L.↗

Electro-Active Polymer (EAP) Actuators for Planetary Applications

NASA is seeking to reduce the mass, size, consumed power, and cost of the instrumentation used in its future missions. An important element of many instruments and devices is the actuation mechanism and electroactive polymers (EAP) are offering an effective alternative to current actuators. In this study, two families of EAP materials were investigated, including bending ionomers and longitudinal electrostatically driven elastomers. These materials were demonstrated to effectively actuate manipulation devices and their performance is being enhanced in this on-going study. The recent observations are reported in this paper, include the operation of the bending-EAP at conditions that exceed the harsh environment on Mars, and identify the obstacles that its properties and characteristics are posing to using them as actuators. Analysis of the electrical characteristics of the ionomer EAP showed that it is a current driven material rather than voltage driven and the conductivity distribution on the surface of the material greatly influences the bending performance. An accurate equivalent circuit modeling of the ionomer EAP performance is essential for the design of effective drive electronics. The ionomer main limitations are the fact that it needs to be moist continuously and the process of electrolysis that takes place during activation. An effective coating technique using a sprayed polymer was developed extending its operation in air from a few minutes to about four months. The coating technique effectively forms the equivalent of a skin to protect the moisture content of the ionomer. In parallel to the development of the bending EAP, the development of computer control of actuated longitudinal EAP has been pursued. An EAP driven miniature robotic arm was constructed and it is controlled by a MATLAB code to drop and lift the arm and close and open EAP fingers of a 4-finger gripper. Keywords: Miniature Robotics, Electroactive Polymers, Electroactive Actuators, EAP Materials

Bar-Cohen, Y.↗

Design of a High-Energy, Two-Stage Pulsed Plasma Thruster

Design details of a proposed high-energy (approx. 50 kJ/pulse), two-stage pulsed plasma thruster are presented. The long-term goal of this project is to develop a high-power (approx. 500 kW), high specific impulse (approx. 7500 s), highly efficient (approx. 50%),and mechanically simple thruster for use as primary propulsion in a high-power nuclear electric propulsion system. The proposed thruster (PRC-PPT1) utilizes a valveless, liquid lithium-fed thermal plasma injector (first stage) followed by a high-energy pulsed electromagnetic accelerator (second stage). A numerical circuit model coupled with one-dimensional current sheet dynamics, as well as a numerical MHD simulation, are used to qualitatively predict the thermal plasma injection and current sheet dynamics, as well as to estimate the projected performance of the thruster. A set of further modelling efforts, and the experimental testing of a prototype thruster, is suggested to determine the feasibility of demonstrating a full scale high-power thruster.

Markusic, T. E.↗

Space Vehicle Power System Comprised of Battery/Capacitor Combinations

Recent improvements in energy densities of batteries open the possibility of using electric rather that hydraulic actuators in space vehicle systems. However, the systems usually require short-duration, high-power pulses. This power profile requires the battery system to be sized to meet the power requirements rather than stored energy requirements, often resulting in a large and inefficient energy storage system. Similar transient power applications have used a combination of two or more disparate energy storage technologies. For instance, placing a capacitor and a battery side-by-side combines the high energy density of a battery with the high power performance of a capacitor and thus can create a lighter and more compact system. A parametric study was performed to identify favorable scenarios for using capacitors. System designs were then carried out using equivalent circuit models developed for five commercial electrochemical capacitor products. Capacitors were sized to satisfy peak power levels and consequently "leveled" the power requirement of the battery, which can then be sized to meet system energy requirements. Simulation results clearly differentiate the performance offered by available capacitor products for the space vehicle applications.

Camarotte, C.↗

Fault Tolerant Homopolar Magnetic Bearings

Magnetic suspensions (MS) satisfy the long life and low loss conditions demanded by satellite and ISS based flywheels used for Energy Storage and Attitude Control (ACESE) service. This paper summarizes the development of a novel MS that improves reliability via fault tolerant operation. Specifically, flux coupling between poles of a homopolar magnetic bearing is shown to deliver desired forces even after termination of coil currents to a subset of failed poles . Linear, coordinate decoupled force-voltage relations are also maintained before and after failure by bias linearization. Current distribution matrices (CDM) which adjust the currents and fluxes following a pole set failure are determined for many faulted pole combinations. The CDM s and the system responses are obtained utilizing 1D magnetic circuit models with fringe and leakage factors derived from detailed, 3D, finite element field models. Reliability results are presented vs. detection/correction delay time and individual power amplifier reliability for 4, 6, and 7 pole configurations. Reliability is shown for two success criteria, i.e. (a) no catcher bearing contact following pole failures and (b) re-levitation off of the catcher bearings following pole failures. An advantage of the method presented over other redundant operation approaches is a significantly reduced requirement for backup hardware such as additional actuators or power amplifiers.

Li, Ming-Hsiu↗

A Study of the Measurement of Seebeck Coefficient of SiGe

In 1821 German Physicist Thomas J. Seebeck discovered that heat could be converted into electricity when a temperature difference was applied across two points on a material. Theoretically, the generated voltage has a directly proportional relationship with the temperature difference. This relationship is the Seebeck coefficient that scientists always referred to when determining the efficiency of a thermoelectricity convention. In our experiments, however, hysteresis loops appeared when we plotted voltage against temperature difference, and the measured Seebeck appeared differently when the measurements were run under vacuum, air, and helium gas. Measurements were done by using a low-frequency AC measuring method. By simulating the experimental setup into a; thermal circuit, we found that the loop and inconsistency in measuring Seebeck coefficient could be explained by studying the behaviors of a RC circuit in a thermal sense. Under vacuum, the gap of the hysteresis loop can be largely eliminated if the time period of the temperature difference increased up to 4800s. The trend of the variations in measuring Seebeck coefficients in different environments can also be predicted by using different thermal circuit models.

Heung, King Yi↗