Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Study Thermographic Flaw Detection

The development of thermographic inspection methods for use on aerospace structures is under investigation. Several different material systems, structural geometries and defect types have been included in this study so as to establish a baseline from which future Infrared Thermography(IRT) testing can be made. This study examines various thermal loading techniques in an attempt to enhance the likelihood of capturing and identifying critically sized flaws under 'non laboratory' actual working conditions. Qualification techniques and calibration standards are also being investigated to standardize the thermographic method. In conjunction with the thermographic inspections, advanced image processing techniques including digital filtering and neural networks have been investigated to increase the ability of detecting and sizing flaws. Here, the digitized thermographic images are mathematically manipulated through various filtering techniques and/or artificial neural mapping schemes to enhance its overall quality, permitting accurate flaw identification even when the signal-to-noise ratio is low.

Walker, James L.↗

Modeling of Branched (L, T and Y) Carbon Nanotubes

Models for connecting two or three carbon nanotubes (CNT) using topological defects (i.e., pentagons and heptagons) are presented for the characterization of experimentally observed L, T and Y CNT junctions. The effects of the separation and orientation of the topological defects on the structures and energetics of these junctions are investigated using the nonlocal density function theory (DFT) and semi-empirical molecular orbital (AM1) calculations, and the Brenner empirical potential molecular mechanics simulations. The potential applications of L, Y and T CNT junctions in nanoelectronic devices are also discussed.

Han, Jie↗

Crystallization Physics in Biomacromolecular Systems

The crystals are built of molecules of protein, nucleic acid and their complexes, like viruses, approx. 5x10(exp 3)+ 3x10(exp 6) Da in weight and 2 + 20 nm in effective diameter. This size strongly exceeds action range of molecular forces and makes a big difference with inorganic crystals. Intermolecular contacts form patches on the biomacromolecular surface. Each patch may occupy only a small percent of the whole surface and vary from polymorph to polymorph of the same protein. Thus, under different conditions (pH, solution chemistry, temperature, any area on the macromolecular surface may form a contact. The crystal Young moduli, E approx. equals 0.1 + 0.5 GPa are more than 10 times lower than that of inorganics and the biomolecules themselves. Water within biocrystals (30-70%) is unable to flow unless typical deformation time is longer than approx. 10(exp -5)s. This explains the discrepancy between light scattering and static measurements of E. Nucleation and Growth requires typically concentrations exceeding the equilibrium ones up to 100 times - because of the new size scale results in 10 - 10(exp 3) times lower kinetic coefficients than that needed for inorganic solution growth. All phenomena observed in the latter occur with protein crystallization and are even better studied by AFM. Crystals are typically facetted. Among unexpected findings of general significance are - net molecular exchange flux at kinks is much lower than that expected from supersaturation, steps with low (< approx. 10(exp -2)) kink density at steps follow Gibbs-Thomson law only at very low supersaturations, step segment growth rate may be independent of step energy. Crystal perfection is a must of biocrystallization to achieve the major goal to find 3-D atomic structure of biomacromolecules by x-ray diffraction. Poor diffraction resolution (> 3Angstrom) makes crystallization a bottleneck for structural biology. All defects typical of small molecule crystals are found in biocrystals, but the defects responsible for poor resolution are not identified. Conformational changes are one of them. Biocrystallization in microgravity reportedly results in 20% cases of better crystals. The mechanism of how lack of convection can do this is still not clear. Lower supersaturation, self-purification &om preferentially trapped homologous impurities and step bunching are viable hypotheses.

Chernov, A. A.↗

Solutal Convection Around Growing Protein Crystal and Diffusional Purification in Space

At least some protein crystals were found to preferentially trap microheterogeneous impurities. The latter are, for example, dimmer molecules of the crystallizing proteines (e.g. ferritin, lysozyme), or the regular molecules on which surfaces small molecules or ions are adsorbed (e.g. acetilated lysozyme) and modi@ molecular charge. Impurities may induce lattice defects and deteriorate structural resolution. Distribution of impurities between mother solution and gorwing crystal is defined by two interrelated distribution coefficients: kappa = rho(sup c, sub 2) and K = (rho(sup c, sub 2)/rho(sup c, sub 1)/rho(sub 2)/rho(sub 1). Here, rho(sub 2), rho(sub 1) and rho(sup c, sub 2) are densities of impurity (2) and regular protein (1) in solution at the growing interface and within the crystal ("c"). For the microheterogeneous impurities studied, K approx. = 2 - 4, so that kappa approx. - 10(exp 2) - 10(exp 3), since K = kappa (rho(sub 1)/rho(sup c, sub 1) and protein solubility ratio rho(sub 1)/rho(sub=p c, sub 2) much less than 1. Therefore, a crystal growing in absence of convection purifies mother solution around itself, grows cleaner and, probably, more perfect. If convection is present, the solution flow permanently brings new impurities to the crystal. This work theoretically addressed two subjects: 1) onset of convection, 2) distribution of impurities.

Lee, Chun P.↗

Fiber Optic Thermal Health Monitoring of Composites

A recently developed technique is presented for thermographic detection of flaws in composite materials by performing temperature measurements with fiber optic Bragg gratings. Individual optical fibers with multiple Bragg gratings employed as surface temperature sensors were bonded to the surfaces of composites with subsurface defects. The investigated structures included a 10-ply composite specimen with subsurface delaminations of various sizes and depths. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The data obtained from grating sensors were analyzed with thermal modeling techniques of conventional thermography to reveal particular characteristics of the interested areas. Results were compared with the calculations using numerical simulation techniques. Methods and limitations for performing in-situ structural health monitoring are discussed.

Wu, Meng-Chou↗

Fiber Optic Thermal Detection of Composite Delaminations

A recently developed technique is presented for thermographic detection of delaminations in composites by performing temperature measurements with fiber optic Bragg gratings. A single optical fiber with multiple Bragg gratings employed as surface temperature sensors was bonded to the surface of a composite with subsurface defects. The investigated structure was a 10-ply composite specimen with prefabricated delaminations of various sizes and depths. Both during and following the application of a thermal heat flux to the surface, the individual Bragg grating sensors measured the temporal and spatial temperature variations. The data obtained from grating sensors were analyzed with thermal modeling techniques of conventional thermography to reveal particular characteristics of the interested areas. Results were compared and found to be consistent with the calculations using numerical simulation techniques. Also discussed are methods including various heating sources and patterns, and their limitations for performing in-situ structural health monitoring.

Wu, Meng-Chou↗

Electron Beam Induced Luminescence of SiO2 Optical Coatings

Optical coatings of disordered thin film SiO,/SiO, samples undergoing electron beam bombardment exhibited a cathodoluminescence effect. Measurements were made of the absolute illuminance and emission spectra as functions of incident electron energy (0.2 keV to 30 keV). flux (approx. 0.1 nA/sq cm to > 100 nA/sq cm) and power (<50 nW/sq cm to > 3mW/sq cm) for coatings (approx.60 nm to approx.200 nm thick) on reflective metal substrates over a range of sample temperatures (approx.40 K to approx.400 K) and emission wavelengths (approx.260 nm to approx.5000 nm). Illuminance reached a plateau saturation intensity I(sub sat) approx. 10(exp -4)W/sq cm. scaling as [I(sub mc)/(I + I(sub mc)/I(sub sat)] as incident power I(sub mc) approached I(sub sat). Well below I(sub sat), illuminance scaled linearly with incident power for lower-energy non-penetrating radiation that deposited all of its energy in the dielectric film. At higher incident energies (> 1-5 keV) electrons penetrate the dielectric, depositing only a fraction of their energy in the dielectric film, where deposited energy scales as the ratio of film thickness to penetration range. Since electron range exhibits a peak below approx. 1 keV, the illuminance decreased with increasing energy for penetrating radiation. The temperature dependence of the illuminance. in general, increased with decreasing temperature. Changes in apparent color with temperature were also observed. Four bands in the UV/VIS/NIR range from 300 nm to 1000 nm were observed in spectral measurements; no significant luminescence was detected in a range from approx. 1000 nm to approx. 5000 nm. These different bands either increased or decreased in intensity and shifted slightly in energy with decreasing temperature. Our measurements are explained in terms of simple disordered band theory models based on atomic-scale stochastic transport of electrons in highly disordered insulating materials. The theoretical models provide a fundamental basis for understanding the dependence of cathodoluminescence on irradiation time, incident flux and energy. and sample thickness and temperature. The observed luminescence occurs when an incident high energy electron excites a valence band electron into the conduction band. Following the excitation. a complex series of transitions take place between the extended conduction states and the long-lived localized trapped states (or chromophores) associated with structural or compositional defects in the dielectric materials. Thc transport equations and models of thc spatial and energy distribution of the trapped states below the mobility edge, their occupancy, and transitions provide microscopic scale insights into this macroscopic phenomenon. Our observations and theoretical models are also compared with similar previous room temperature studies of similar SiO2 films.

Dennison, J. R.↗

Development of New Dielectric NDE Techniques for Spaceflight Materials

Dielectric Spectroscopy is a relatively new technique for non-destructively measuring material properties. The goal for this project is to extend the use of state-of-the-art dielectric spectroscopy systems to measure the spectra of spaceflight materials and develop non-destructive evaluation (NDE) sensors based on dielectric material properties. This work may lead to a new class of material density, moisture, temperature, and defect sensors providing structural integrity and health measurements for future spacecraft and launch structures.

Project↗

Enhanced Quantification of 3D Woven Composites Via Fourier Analysis and Structure Tensors Applied to CT Scans

NASA's development of advanced 3D woven carbon composites, such as HEEET and 3MDCP, represents a significant leap in materials designed to endure extreme atmospheric entry conditions. However, the internal complexity of these materials introduces a variety of structures and novel defect types. Traditional characterization methods rely on labor-intensive, manual examination of X-ray CT scans, demanding considerable time and expertise. This process, while thorough, is not sustainable for large-scale analysis and defect tracking. Addressing this critical challenge, this presentation introduces an innovative suite of automated tools and analytical techniques, pioneered by the Mars Sample Return (MSR) Earth Entry System (EES) Thermal Protection System (TPS) project. These advancements offer a more efficient and accurate approach for quantifying CT data and characterizing the defects of 3D woven composites.

Magnus Haw↗

Quantitative Characterization of 3D Woven Composites Via Fourier Analysis and Structure Tensors Applied to CT Scans

NASA's development of advanced 3D woven carbon composites, such as HEEET and 3MDCP, represents a significant leap in materials designed to endure extreme atmospheric entry conditions. However, the internal complexity of these materials introduces a variety of structures and novel defect types. Traditional characterization methods rely on labor-intensive, manual examination of X-ray CT scans, demanding considerable time and expertise. This process, while thorough, is not sustainable for large-scale analysis and defect tracking. Addressing this critical challenge, this presentation introduces an innovative suite of automated tools and analytical techniques, pioneered by the Mars Sample Return (MSR) Earth Entry System (EES) Thermal Protection System (TPS) project. These advancements offer a more efficient and accurate approach for quantifying CT data and characterizing the defects of 3D woven composites.

3D Woven↗

Effects of Defects Analysis and Sizing Framework for Efficient Design of Composite Structures

Design of large composite structures requires striking a balance between permitted flaw size,strength margins, weight, and production rate. Stringent requirements manufacturing flaws can result in a lightweight structure because the strength properties are assumed to be closer to pristine. However, these stringent requirements can lead to production delays due to increased inspection and rework needed during the layup and rejection of parts after cure. Conversely, permitting larger flaws can reduce production delays, but will likely result in a heavier structure due to increased conservatism needed to maintain acceptable structural margins. The tradeoff between these criteria can vary between different structures and material systems, so the balance between manufacturing and design requirements is always a moving target. Assessment of this tradeoff requires having the ability to quickly evaluate the impact of flaw size on strength margin across an entire structure for a large number of load cases. The approach taken in this work is to implement an effects of defects analysis and sizing framework within HyperX. HyperX performs optimization of composite structures; this capability has been enhanced to include structural flaw data in the margin of safety calculations performed during optimization. Both the flaw import process and analysis of flaws have been generalized such that any flaw type from any source can be considered. The resulting tool enables rapid assessment of the impact of defects both at a vehicle and part level.

Effects of defects↗

Effects of Defects Analysis and Sizing Framework for Efficient Design of Composite Structures

Design of large composite structures requires striking a balance between permitted flaw size,strength margins, weight, and production rate. Stringent requirements manufacturing flaws can result in a lightweight structure because the strength properties are assumed to be closer to pristine. However, these stringent requirements can lead to production delays due to increased inspection and rework needed during the layup and rejection of parts after cure. Conversely, permitting larger flaws can reduce production delays, but will likely result in a heavier structure due to increased conservatism needed to maintain acceptable structural margins. The tradeoff between these criteria can vary between different structures and material systems, so the balance between manufacturing and design requirements is always a moving target. Assessment of this tradeoff requires having the ability to quickly evaluate the impact of flaw size on strength margin across an entire structure for a large number of load cases. The approach taken in this work is to implement an effects of defects analysis and sizing framework within HyperX. HyperX performs optimization of composite structures; this capability has been enhanced to include structural flaw data in the margin of safety calculations performed during optimization. Both the flaw import process and analysis of flaws have been generalized such that any flaw type from any source can be considered. The resulting tool enables rapid assessment of the impact of defects both at a vehicle and part level.

Effects of defects↗

Stacking Defects in Synthetic and Meteoritic Hibonites: Implications for High-Temperature Processes in the Solar Nebula

Hibonite (CaAl12O19) is a primary, highly refractory phase occurring in many Ca-Al-rich inclusions (CAIs) from different chondrite groups, except CI chondrites. Hibonite is predicted to be one of the earliest minerals to condense during cooling of the solar nebula at higher temperatures than any other major CAI mineral. Therefore, hibonite has great potential to reveal the processes and conditions of the very early, high-temperature stages of the solar nebular evolution. Previous microstructural studies of hibonite in CAIs and their Wark-Lovering (WL) rims showed the presence of numerous stacking defects in hibonite. These defects are interpreted as the modification of the stacking sequences of spinel and Ca-containing blocks within the ideal hexagonal hibonite structure, as shown by experimental studies of reaction-sintered ceramic CaO-Al2O3 compounds. We performed preliminary experiments in the CaO-Al2O3-MgO system to understand the formation processes and conditions of defect-structured hibonite found in meteorites.

Han, J.↗

Advanced Finite Element Modeling of Low Cycle Fatigue Crack Growth

This document (a viewgraph presentation) assumes a crack-like defect of a size which may be missed in inspection will exist in most critical location of any critical structure or component. Flaw existence assumption is usually, but not always, conservative based on past experiences in NASA and knowledge of manufacturing processes. Cyclic, environmental, and sustained loads used to generate stresses on models. Fracture Mechanics analysis used to predict crack growth and residual strength. Must show that defective structure will still provide four times required mission lifetime. Special exemptions cover redundant structures, low risk parts, etc. Assessments require specialized software tools, experienced analysts, and reliable material crack growth rate test database.

Gregg, Wayne↗

Detection of lack of fusion using opaque additives

Reliable nondestructive inspection for incomplete weldment penetration and rapid oxidation of aluminum surfaces when exposed to the atmosphere are currently two major problems in welded aluminum spacecraft structure. Incomplete-penetration defects are extremely difficult to detect and can lead to catastrophic failure of the structure. The moisture absorbed by aluminum oxide on the surface can cause weldment porosity if the surface is not cleaned before welding. The approach employed in this program to solve both problems was to employ copper as a coating to prevent oxidation of the aluminum. Also, copper was used as an opaque additive in the weldment to enhance X-ray detection in the event of incomplete penetration.

Cook, J. L.↗

Protein Crystallization

Nucleation, growth and perfection of protein crystals will be overviewed along with crystal mechanical properties. The knowledge is based on experiments using optical and force crystals behave similar to inorganic crystals, though with a difference in orders of magnitude in growing parameters. For example, the low incorporation rate of large biomolecules requires up to 100 times larger supersaturation to grow protein, rather than inorganic crystals. Nucleation is often poorly reproducible, partly because of turbulence accompanying the mixing of precipitant with protein solution. Light scattering reveals fluctuations of molecular cluster size, its growth, surface energies and increased clustering as protein ages. Growth most often occurs layer-by-layer resulting in faceted crystals. New molecular layer on crystal face is terminated by a step where molecular incorporation occurs. Quantitative data on the incorporation rate will be discussed. Rounded crystals with molecularly disordered interfaces will be explained. Defects in crystals compromise the x-ray diffraction resolution crucially needed to find the 3D atomic structure of biomolecules. The defects are immobile so that birth defects stay forever. All lattice defects known for inorganics are revealed in protein crystals. Contribution of molecular conformations to lattice disorder is important, but not studied. This contribution may be enhanced by stress field from other defects. Homologous impurities (e.g., dimers, acetylated molecules) are trapped more willingly by a growing crystal than foreign protein impurities. The trapped impurities induce internal stress eliminated in crystals exceeding a critical size (part of mni for ferritin, lysozyme). Lesser impurities are trapped from stagnant, as compared to the flowing, solution. Freezing may induce much more defects unless quickly amorphysizing intracrystalline water.

Chernov, Alexander A.↗

The Role of Water in the Stability of Cratonic Keels

Cratons are typically underlain by large, deep, and old lithospheric keels (to greater than 200 km depth, greater than 2.5 Ga old) projecting into the asthenosphere (e.g., Jordan, 1978; Richardson et al., 1984). This has mystified Earth scientists as the dynamic and relatively hot asthenosphere should have eroded away these keels over time (e.g., Sleep, 2003; O'Neill et al., 2008; Karato, 2010). Three key factors have been invoked to explain cratonic root survival: 1) Low density makes the cratonic mantle buoyant (e.g., Poudjom Djomani et al., 2001). 2) Low temperatures (e.g., Pollack, 1986; Boyd, 1987), and 3) low water contents (e.g., Pollack, 1986), would make cratonic roots mechanically strong. Here we address the mechanism of the longevity of continental mantle lithosphere by focusing on the water parameter. Although nominally anhydrous , olivine, pyroxene and garnet can accommodate trace amounts of water in the form of H bonded to structural O in mineral defects (e.g., Bell and Rossman, 1992). Olivine softens by orders of magnitude if water (1-1000 ppm H2O) is added to its structure (e.g., Mackwell et al., 1985). Our recent work has placed constraints on the distribution of water measured in peridotite minerals in the cratonic root beneath the Kaapvaal in southern Africa (Peslier et al., 2010). At P greater than 5 GPa, the water contents of pyroxene remain relatively constant while those of olivine systematically decrease from 50 to less than 10 ppm H2O at 6.4 GPa. We hypothesized that at P greater than 6.4 GPa, i.e. at the bottom of the cratonic lithosphere, olivines are essentially dry (greater than 10 ppm H2O). As olivine likely controls the rheology of the mantle, we calculated that the dry olivines could be responsible for a contrast in viscosity between cratonic lithosphere and surrounding asthenosphere large enough to explain the resistance of cratonic root to asthenospheric delamination.

Peslier, Anne H.↗