Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The Effect of Prosumer Duality on Power Market: The Effect of Market Regulation

Electricity prosumers are energy subsystems that not only consume, but also produce electricity. They are present in distribution level networks as traditional utility customers who have installed distributed energy resources. They are also present in transmission level networks as large conglomerates own both generation assets and large industrial loads. Previous work on the economics of prosumers has demonstrated that prosumers in a market have incentives to behave more competitively compared to producers and consumers in traditional markets. This paper further explores the behavior of prosumers and their response to market policies including the allocation of network losses and the impact of net metering. We extend a Cournot model of a dual prosumer and find that prosumers respond with higher supply quantities if network losses are allocated to demand base. They respond with lower supply quantities if network losses are allocated to supply base. Allocating network losses to demand base also causes equilibrium prices to decline. Markets where prosumers first satisfy their own load and then sell the balance of electricity to the grid have lower quantities and higher prices compared to markets where prosumers buy and sell at locational marginal price.

Tsybina, Eve↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

COVID-19 pandemic ramifications on residential Smart homes energy use load profiles

The COVID-19 pandemic has significantly affected people’s behavioral patterns and schedules because of stay-at-home orders and a reduction of social interactions. Therefore, the shape of electrical loads associated with residential buildings has also changed. In this paper, we quantify the changes and perform a detailed analysis on how the load shapes have changed, and we make potential recommendations for utilities to handle peak load and demand response. Our analysis incorporates data from before and after the onset of the COVID-19 pandemic, from an Alabama Power Smart Neighborhood with energy-efficient/smart devices, using around 40 advanced metering infrastructure data points. This paper highlights the energy usage pattern changes between weekdays and weekends pre– and post–COVID-19 pandemic times. The weekend usage patterns look similar pre– and post–COVID-19 pandemic, but weekday patterns show significant changes. We also compare energy use of the Smart Neighborhood with a traditional neighborhood to better understand how energy-efficient/smart devices can provide energy savings, especially because of increased work-from-home situations. HVAC and water heating remain the largest consumers of electricity in residential homes, and our findings indicate an even further increase in energy use by these systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Levelized cost of charging of extreme fast charging with stationary LMO/LTO batteries

Extreme DC fast charging for electric vehicles (EVs) could be competitive with the internal combustion engine refueling experience and enable longer-distance travel, which could help with EV adoption and decarbonization, but these systems have high capital costs and extremely variable high-power demands. Behind-the-meter systems (BTMS) could support extreme-fast-charging (XFC) stations to increase nationwide adoption of EVs. Here, this study examines the optimal break-even levelized cost of charging (LCOC) across 96 BTMS scenarios to enable low-wait XFC stations providing 200 miles of charge in 10 min. This research simulates LCOC via synthetic XFC-capable EV loads, machine-learned battery life models from testing data, and nonlinear optimal controls, co-minimizing complex utility costs and battery replacements. An aggregate optimal BTMS design treating each EV load as equal likely gives an optimal LCOC per utility rate, the average of which is $\$$0.59/kWh. In addition, the sensitivity of optimal and off-optimal design factors, the long-life LMO/LTO chemistry, and optimized controls are analyzed. The battery control model, based on battery stressors to compare chemistries, optimizes LMO/LTO resting state of charge and cycle depth without compromising cost reduction, which enables greater flexibility in operation. The LCOC savings due to replacement reduction are small, up to $\$$0.035/kWh (6%), with an average of $\$$0.02/kWh (3.5%). Compared with gasoline stations, the aggregate XFC station design achieves comparable speed, experience of service, and cost at $\$$3.81/gal gasoline, showing that EVs can replace gasoline vehicles even for longer-distance travel.

25 ENERGY STORAGE↗

PV Field Reliability Status--Analysis of 100,000 Solar Systems

In this paper, we analyzed annual production data from 100 000 photovoltaic systems as well as comments relating to their performance and maintenance. Our analysis revealed that 80% to 90% of all systems performed within 10% of the predicted production or better. Also, 56% of the systems were still performing above P50 or the median at 5 years. However, a small but significant tail of about 7000 systems perform below P90 expectations. In general, residential systems have a lower rate of failure than utility or commercial systems. Despite higher rates of component failures, utility systems lose less power than residential or commercial systems. This outcome is likely due to closer monitoring and better operations and maintenance practices. Inverters are still the components that reportedly fail most often (4%-6%), but other failures such as unspecified repair and meters cause more production loss. Reported module failures are relatively rare (0.2%) and are within the range of historical values. Installation quality affects performance and safety as indicated by data showing connector, wiring, breaker, and fuse failures due to undersizing, electrical design, and improper connection. Lastly, early detection of degradation and proactive response resulted in less impact on production than reactive, unplanned repairs.

14 SOLAR ENERGY↗

Mechanistic understanding of aging behaviors of critical-material-free Li 4 Ti 5 O 12 //LiNi 0.9 Mn 0.1 O 2 cells with fluorinated carbonate-based electrolytes for safe energy storage with ultra-long life span

Behind-the-meter storage (BTMS) systems - a viable method to minimize potential risk of blackout events and stabilize the grid - require a different type of cost-effective energy storage with excellent safety, ultra-long (>20 years) cycle life and reasonable energy density compared that of electric vehicles. To increase the energy density and reduce the cost of a long-term cyclable lithium-titanate-based cell, it is required to employ a critical-material-free high voltage cathode and an electrolyte with good electrochemical and transport properties. In this report the long-term electrochemical performance and behaviors of selected critical-material-free Li 4 Ti 5 O 12 (LTO)//LiNi 0.9 Mn 0.1 O 2 (LNMO) full cells for BTMS applications are evaluated and analyzed in the optimized voltage range of 1.4-2.7 V at 45 degrees C with different fluorinated carbonate-based electrolytes. The fluoroethylene carbonate (FEC)-based electrolyte cell shows the highest capacity retention of 57.9% and Coulombic efficiency (CE) of 99.96% after 1000 cycles, potentially attributed to a dense, homogenous and less resistive LiF-rich solid-electrolyte interphase (SEI) layer formed on the surface of LTO that may mitigate electrolyte decomposition and maintain relatively low cell impedance during cycling. The 3,3,3-fluoroethylmethyl carbonate (F-EMC)-based electrolyte cell, however, presents the worst performance with lower capacity and a sharp decrease of CE, due to unstable and non-uniform SEI formation and continuous oxidative electrolyte decomposition. This mechanistic understanding of cell aging behaviors and failure mechanisms with detailed analysis of surface chemistry and electrode morphology can guide design of new electrode chemistries and electrolyte formulations for the development of BTMS batteries.

25 ENERGY STORAGE↗

Characterization of power delivery and losses in a long coaxial inner MITL

The long coaxial inner magnetically insulated transmission line (MITL) is considered as a possible transmission line to guide power to deep underground high yield fusion experiments. The considered dimensions are of order 10-15 meters in length, 60 cm radius, and 6 mm AK gap, with peak current 60 MA and peak pulse 100 ns. In designing such a MITL, the main concern is power loss due to low density plasmas being produced by high electric fields and temperatures. It is found that a 10m-long prototypical MITL is a viable design, with maximum current losses below 10% and temperature rise due to electron impact not exceeding 400°C, thereby avoiding thermal desorption of contaminants and the formation of low density plasmas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated, including a single-, double-, and multi-lateral design. The subsurface within the area of interest is characterized by deep, hot (> 200 degrees C) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lie(s) within a target depth of 6 km, where temperatures are estimated to approach 300 degrees C. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot, dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down techno-economic analysis model. The results show that the performance- and cost-optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60 degrees C/km. By injecting 20 degrees C-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth (i.e., 2.2 MWe net plant output) can be achieved, resulting in an LCOE and LCOH of $136/MWhe and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

A Modified Sequence-to-point HVAC Load Disaggregation Algorithm

This paper presents a modified sequence-to-point (S2P) algorithm for disaggregating the heat, ventilation, and air conditioning (HVAC) load from the total building electricity consumption. The original S2P model is convolutional neural network (CNN) based, which uses load profiles as inputs. We propose three modifications. First, the input convolution layer is changed from 1D to 2D so that normalized temperature profiles are also used inputs to the S2P model. Second, a drop-out layer is added to improve adaptability and generalizability so that the model trained in one area can be transferred to other geographical areas without labelled HVAC data. Third, a fine-tuning process is proposed for areas with a small amount of labelled HVAC data so that the pre-trained S2P model can be fine-tuned to achieve higher disaggregation accuracy (i.e., better transferability) in other areas. The model is first trained and tested using smart meter and sub-metered HVAC data collected in Austin, Texas. Then, the trained model is tested on two other areas: Boulder, Colorado and San Diego, California. Simulation results show that the proposed modified S2P algorithm outperforms the original S2P model and the support-vector machine based approach in accuracy, adaptability, and transferability.

Ye, Kai↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

Characterizing the Oscillatory Properties of Bulk Electric Systems

This paper presents a process for characterizing the oscillatory dynamics of a large bulk power system. As a demonstration, the process is applied to the Western Interconnection of North America. Several complementary analysis approaches, both new and existing, are employed to provide a comprehensive understanding of the oscillatory properties of the system. Established modal analysis techniques based on ringdown and mode-meter algorithms are utilized. In addition, we derive and apply methods based on spectral correlation analysis to identify modal frequencies, distinguish between modes that are closely spaced in frequency, and determine locations at which the modes are observable. Critical interarea modes are identified and characterized using actual-system synchrophasor measurements taken over several years of operation in concert with industry-standard simulation models. This includes 145 hours of PMU data and two planning base cases.

42 ENGINEERING↗

Consumer safety-oriented scheduling of rotating power outages during heat waves

Extreme heat events have widespread effects on power systems, reducing available generation capacity, limiting transmission capabilities, and causing unusual demand patterns on the consumer side. As these combined effects expose bulk transmission systems to potential large-scale blackouts, utilities may be required to schedule and apply rotating outages, by temporarily and alternately disconnecting distribution substations to reduce overload. However, utilities lack mechanisms to inform these events, exacerbating the negative effects of heat waves on affected communities. This paper introduces a novel framework for scheduling rotating outages during heat waves while considering impacts on consumers’ safety. Instead of random sequential load shedding, we propose a methodology to rotate power outages considering a metric that quantifies the indoor overheating risk of groups of consumers during a power outage. The overheating risk is derived from a detailed building simulation using CityBES, where the buildings are modeled based on available data—use type, year built, floor area, number of stories, location—while presence of air conditioning and occupancy are calibrated from smart meter data. Based on the metric, an algorithm to schedule the rotating outages is applied to prioritize feeders for disconnection at each hour according to their overheating risk to meet a utility load reduction target. Applied to two substations and seven feeders in the Portland General Electric territory, the results show that this approach effectively leads to the lowest overheating risk during the resulting outage schedules, with an average 10.1% lower overheating compared to uninformed schedules.

Building thermal simulation↗

Guest Editorial: Advanced Data-Analytics for Power System Operation, Control, and Enhanced Situational Awareness

Along with the smart grid development, modern power systems are entering a ‘data-intensive’ era. A vast volume of data from power grids is being collected through advanced sensing and communication technologies, such as smart metering data, phasor measurement data, as well as meteorological data (e.g., wind speed and solar irradiance) related to renewable power generation. Such data contains comprehensive information about the power system covering equipment's health status, power grid's static and dynamic characteristics, renewable power generation, customers’ electricity usage pattern, etc. Therefore, advanced data-analytics techniques are needed to convert such data to knowledge for practical applications. In line with the trend of widespread data-driven applications in power systems, this Special Issue aims to present state-of-the-art research works on advanced data-analytics for power system's operation, control, and situational awareness. There are in total twenty-six papers accepted for publication in this Special Issue through careful peer reviews and revisions. Under the overarching theme of data-driven applications in power systems, the selected papers are broadly categorised into five topics. The summary of every topic is given below. You are, however, strongly encouraged to read the full paper if interested.

Xu, Yan↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

Autonomous Energy Systems

Energy systems are increasingly complicated by the proliferation of clean energy technologies such as solar, wind, storage, electric vehicles, and building automations. Future energy systems will require secure, autonomous, and reliable communications, control, and interoperability among millions of distributed generation points and billions of buildings, vehicles, and more. To enable effective management of the anticipated growth of distributed devices and the deluge of data and extensive metering that will follow, the National Renewable Energy Laboratory (NREL) has developed the concept of autonomous energy systems (AES).

autonomous↗

Oil-impregnated densified wood veneer with high electrical insulation enabled by nanosized oil channels

Growing energy demands and renewable integration are stressing the aging power grid infrastructure. Lignocellulosic oil-impregnated paper is widely used in power transformers but suffers from critical limitations, such as low dielectric strength, mechanical strength, and thermal conductivity, causing premature transformer failures. Here, we demonstrate a superior electrically insulating oil-impregnated paper design using the naturally anisotropic structure of densified wood veneer to achieve nanosized channels of oil that efficiently disrupt electrical breakdown pathways. The developed oil-impregnated densified wood (ODW) creates aligned cellulose fibers with 166 ± 87–nanometer oil nanochannels, achieving record dielectric strength of 105 kilovolts per millimeter. The structure also delivers a mechanical strength of up to 384 megapascals and a thermal conductivity of 0.33 watts per meter per kelvin, enabling enhanced longevity upon thermal aging tests. The ODW could replace conventional transformer insulation to enhance power transformer performance and improve lifetime. Moreover, its anisotropic oil-filled nanochannel design offers a general strategy for hybrid dielectrics in medium- and high-voltage applications.

36 MATERIALS SCIENCE↗

Storage Futures Study - Distributed Solar and Storage Outlook: Methodology and Scenarios

This presentation discusses the fourth report in NREL’s Storage Futures Study (SFS) publications. The SFS is a multiyear research project that explores the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This report describes the expanded capabilities of the Distributed Generation Market Demand (dGen) model to analyze the economics of distributed (behind-the-meter) PV paired with battery storage systems and presents projections of adoption for the contiguous United States out to 2050 under a range of scenarios. These scenarios use technology cost and performance assumptions consistent with the National Renewable Energy Laboratory’s 2020 Standard Scenarios paired with updated battery cost projections and existing policies. Additional scenarios evaluate sensitivities to the value of backup power and DER compensation mechanisms, collectively characterizing the future potential for behind-the-meter storage and identifying key drivers of adoption. Adoption projections of DER and battery storage at high spatial and temporal resolution, as presented in this report, can enable informed planning of technical infrastructure that can help planners capture the benefits and mitigate challenges to support the ongoing trend toward distributed electricity generation.

backup power↗