Search NASA⌕ Search

SEARCH · Search NASA

Results for “environmental sample results”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Materials International Space Station Experiment-9 (MISSE-9) Polymers and Composites Experiment

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet, x-ray, and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation, threatening spacecraft performance and durability. To increase our understanding of effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn has developed a series of experiments flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). These experiments have provided critical LEO space environment durability data such as AO erosion data for many materials and mechanical properties changes after long term space exposure. In continuing these studies, a new experiment called the Polymers and Composites Experiment has been selected for flight on the MISSE-Flight Facility (MISSE-FF). The Polymers and Composites Experiment will be flown as part of the MISSE-9 mission, the inaugural mission of MISSE-FF manifested on SpaceX-14. This experiment includes 138 samples being flown in ram, wake or zenith orientations for space environmental durability assessment. The primary objective is to determine the LEO AO erosion yield, Ey (the volume loss per incident oxygen atom (cm3/atom)), of polymers, composites, and coated samples, as a function of solar irradiation and AO fluence. In addition, epoxy samples with varying levels of ZnO powder are included to study the effect of filler quantity on AO erosion. An AO Scattering Chamber is included to help improve the understanding of AO scattering mechanisms for improved AO undercutting modeling. Indium tin oxide (ITO) coated samples are included to validate the durability of ITO conductive coatings in LEO. Tensile samples of Teflon fluorinated ethylene propylene (FEP) of varying thicknesses and back-surface coatings will be flown in wake and zenith orientations to study radiation embrittlement versus thickness, and the effect of heating on FEP embrittlement. Finally, shape memory composite and cosmic ray shielding samples will be flown for LEO durability assessment. This paper presents an overview of the MISSE-9 Polymers and Composites Experiment.

Embrittlement↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

W T Wallace↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

W T Wallace↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

William T Wallace↗

Spacelab Charcoal Analyses

This report describes analytical methods and results obtained from chemical analysis of 31 charcoal samples in five sets. Each set was obtained from a single scrubber used to filter ambient air on board a Spacelab mission. Analysis of the charcoal samples was conducted by thermal desorption followed by gas chromatography/mass spectrometry (GC/MS). All samples were analyzed using identical methods. The method used for these analyses was able to detect compounds independent of their polarity or volatility. In addition to the charcoal samples, analyses of three Environmental Control and Life Support System (ECLSS) water samples were conducted specifically for trimethylamine.

Slivon, L. E.↗

Performance Simulations for a Spaceborne Methane Lidar Mission

Future spaceborne lidar measurements of key anthropogenic greenhouse gases are expected to close current observational gaps particularly over remote, polar, and aerosol-contaminated regions, where actual in situ and passive remote sensing observation techniques have difficulties. For methane, a "Methane Remote Lidar Mission" was proposed by Deutsches Zentrum fuer Luft- und Raumfahrt and Centre National d'Etudes Spatiales in the frame of a German-French climate monitoring initiative. Simulations assess the performance of this mission with the help of Moderate Resolution Imaging Spectroradiometer and Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations of the earth's surface albedo and atmospheric optical depth. These are key environmental parameters for integrated path differential absorption lidar which uses the surface backscatter to measure the total atmospheric methane column. Results showthat a lidar with an average optical power of 0.45W at 1.6 μm wavelength and a telescope diameter of 0.55 m, installed on a low Earth orbit platform(506 km), will measure methane columns at precisions of 1.2%, 1.7%, and 2.1% over land, water, and snow or ice surfaces, respectively, for monthly aggregated measurement samples within areas of 50 × 50 km2. Globally, the mean precision for the simulated year 2007 is 1.6%, with a standard deviation of 0.7%. At high latitudes, a lower reflectance due to snow and ice is compensated by denser measurements, owing to the orbital pattern. Over key methane source regions such as densely populated areas, boreal and tropical wetlands, or permafrost, our simulations show that the measurement precision will be between 1 and 2%.

methane↗

Fast Sensitivity-Based Optimal Trajectory Updates for Descent Operations Subject to Time Constraints

The ability to meet a controlled time of arrival during a continuous descent operation will enable environmentally friendly and fuel efficient descent operations while simultaneously maintaining airport throughput. Previous work showed that guidance strategies based on a frequent recalculation of the optimal trajectory during the descent result in excellent environmental impact mitigation figures while meeting operational constraints in the presence of modelling errors. However, the time lag of recalculating the trajectory using traditional optimisation algorithms could lead to performance degradation and stability issues. This paper proposes an alternative strategy, which allows for fast updates of the optimal trajectory based on parametric sensitivities. Promising results show that the performance of this method is comparable to that of instantaneously recalculating the optimal descent trajectory at each time sample.

Dalmau, Ramon↗

Space Station Freedom environmental database system (FEDS) for MSFC testing

The Water Recovery Test (WRT) at Marshall Space Flight Center (MSFC) is the first demonstration of integrated water recovery systems for potable and hygiene water reuse as envisioned for Space Station Freedom (SSF). In order to satisfy the safety and health requirements placed on the SSF program and facilitate test data assessment, an extensive laboratory analysis database was established to provide a central archive and data retrieval function. The database is required to store analysis results for physical, chemical, and microbial parameters measured from water, air and surface samples collected at various locations throughout the test facility. The Oracle Relational Database Management System (RDBMS) was utilized to implement a secured on-line information system with the ECLSS WRT program as the foundation for this system. The database is supported on a VAX/VMS 8810 series mainframe and is accessible from the Marshall Information Network System (MINS). This paper summarizes the database requirements, system design, interfaces, and future enhancements.

Story, Gail S.↗

Toxicity of Carbon Nanotubes and Its Implications for Occupational and Environmental Health

Carbon nanotubes (CNTs), which possess desirable electrical and mechanical properties, potentially have wide industrial applications. CNTs exist in two forms, single-wall (SW) and multi-wall (MW). There has been great concern that if CNTs enter the work environment as suspended respirable particulate matter (PM), they could pose an inhalation hazard. The results of recent rodent studies have collectively shown that CNTs can produce inflammation, epithelioid granulomas, fibrosis, and biochemical changes in the lungs. Studies in mice given equal amounts of test dusts showed that CNTs were more toxic than quartz and produced lesions that became progressively more pronounced. These results have led us to recommend that respirable CNT dust be considered a serious occupational health hazard, and that exposure limits be established in the expectation of expanded industrial applications. CNTs, which are totally insoluble and fibrous, would be expected to be more biopersistent than mineral fibers. Biopersistence is the key factor determining the long-term toxicity of mineral fibers and certainly of CNTs too. We have postulated that the electrical and fibrous properties of CNTs also play important roles in the toxicity of CNTs in the lungs. Recently, MWCNTs have been found in ultrafine PM aggregates in combustion streams of methane, propane, and natural-gas flames of typical stoves; indoor and outdoor fine (< 2.5 micron) PM samples were reported to contain significant fractions of MWCNTs. Environmental fine PM is mainly formed from combustion of fuels, and fine PM has been reported to be a major contributor to the induction of cardiopulmonary diseases by pollutants. Given that manufactured SWCNTs and/or MWCNTs have elicited pathological changes in the lungs and heart, we have postulated that exposure to combustion-generated MWCNTs in fine PM in the air may play a significant role in air pollution-related cardiopulmonary diseases. Therefore, CNTs from manufacturing and combustion sources in the environment could have adverse effects on human health.

Lam, Chiu-wing↗

Stability of silica heat shield materials in the Space Shuttle environment

Sample tiles of Space Shuttle reusable surface insulation (RSI) and fibrous refractory composite insulation (FRCI) have been alternately exposed to simulated mission heating and the Kennedy Space Center launch-pad environment for up to 50 cycles. The two types of tiles were coated with an identical glass composition. The coating on RSI tiles was prone to cracking in the test environment while the same coating on FRCI was not. Absorption of water contaminated with environmental deposits resulted in accelerated devitrification in the RSI tiles. Devitrification in FRCI tiles was significantly less. The rate of environmental degradation of tiles appeared to be dependent on the amount of water absorption.

Ransone, P. O.↗

Predictions of LDEF radioactivity and comparison with measurements

As part of the program to utilize LDEF data for evaluation and improvement of current ionizing radiation environmental models and related predictive methods for future LEO missions, calculations have been carried out to compare with the induced radioactivity measured in metal samples placed on LDEF. The predicted activation is about a factor of two lower than observed, which is attributed to deficiencies in the AP8 trapped proton model. It is shown that this finding based on activation sample data is consistent with comparisons made with other LDEF activation and dose data. Plans for confirming these results utilizing additional LDEF data sets, and plans for model modifications to improve the agreement with LDEF data, are discussed.

Armstrong, T. W.↗

Marked point process models of raindrop-size distributions

The principal process considered in this paper is the flux of raindrops through a volume of the atmosphere. This process is of fundamental importance for a wide variety of engineering and environmental problems, notably remote sensing of precipitation, infiltration of rainfall, soil erosion, atmospheric deposition of pollutants, and design of microwave communication systems. A marked point process model is developed in which the point process represents the arrival times of drops at the upper surface of a sample volume and the mark associated with a drop is its diameter. In the model, both the rate of occurrence of raindrops and the distribution of drop diameters vary randomly over time. Results that relate the drop-size distribution within the sample volume to the probability law of the drop-arrival process are presented. These results allow straightforward comparisons between temporal characterizations of drop-size distributions and spatial characterizations. Representations for derived processes such as rainfall rate and reflectivity are shown to be quite accurate using raindrop data from North Carolina.

Smith, James A.↗

Synchrontron VUV and Soft X-Ray Radiation Effects on Aluminized Teflon FEP

Surfaces of the aluminized Teflon FEP multi-layer thermal insulation on the Hubble Space Telescope (HST) were found to be cracked and curled in some areas at the time of the second servicing, mission in February 1997, 6.8 years after HST was deployed in low Earth orbit (LEO). As part of a test program to assess environmental conditions which would produce embrittlement sufficient to cause cracking of Teflon on HST, samples of Teflon FEP with a backside layer of vapor deposited aluminum were exposed to vacuum ultraviolet (VUV) and soft x-ray radiation of various energies using facilities at the National Synchrotron Light Source. Brookhaven National Laboratory. Samples were exposed to synchrotron radiation of narrow energy bands centered on energies between 69 eV and 1900 eV. Samples were analyzed for ultimate tensile strength and elongation. Results will be compared to those of aluminized Teflon FEP retrieved from HST after 3.6 years and 6.8 years on orbit and will he referenced to estimated HST mission doses of VUV and soft x-ray radiation.

Dever, Joyce A.↗

Electron Tomography of Nanoparticle Clusters: Implications for Atmospheric Lifetimes and Radiative Forcing of Soot

Nanoparticles are ubiquitous in nature. Their large surface areas and consequent chemical reactivity typically result in their aggregation into clusters. Their chemical and physical properties depend on cluster shapes, which are commonly complex and unknown. This is the first application of electron tomography with a transmission electron microscope to quantitatively determine the three-dimensional (3D) shapes, volumes, and surface areas of nanoparticle clusters. We use soot (black carbon, BC) nanoparticles as an example because it is a major contributor to environmental degradation and global climate change. To the extent that our samples are representative, we find that quantitative measurements of soot surface areas and volumes derived from electron tomograms differ from geometrically derived values by, respectively, almost one and two orders of magnitude. Global sensitivity studies suggest that the global burden and direct radiative forcing of fractal BC are only about 60% of the value if it is assumed that BC has a spherical shape.

vanPoppel, Laura H.↗

Mars Atmospheric Escape Recorded by H, C and O Isotope Ratios in Carbon Dioxide and Water Measured by the Sam Tunable Laser Spectrometer on the Curiosity Rover

Stable isotope ratios in C, H, N, O and S are powerful indicators of a wide variety of planetary geophysical processes that can identify origin, transport, temperature history, radiation exposure, atmospheric escape, environmental habitability and biological activity [2]. For Mars, measurements to date have indicated enrichment in all the heavier isotopes consistent with atmospheric escape processes, but with uncertainty too high to tie the results with the more precise isotopic ratios achieved from SNC meteoritic analyses. We will present results to date of H, C and O isotope ratios in CO2 and H2O made to high precision (few per mil) using the Tunable Laser Spectrometer (TLS) that is part of the Sample Analysis at Mars (SAM) instrument suite on MSL s Curiosity Rover.

Webster, C. R.↗

Solid propellant exhausted aluminum oxide and hydrogen chloride - Environmental considerations

Measurements of gaseous hydrogen chloride (HCl) and particulate aluminum oxide (Al2O3) were made during penetrations of five Space Shuttle exhaust clouds and one static ground test firing of a shuttle booster. Instrumented aircraft were used to penetrate exhaust clouds and to measure and/or collect samples of exhaust for subsequent analyses. The focus was on the primary solid rocket motor exhaust products, HCl and Al2O3, from the Space Shuttle's solid boosters. Time-dependent behavior of HCl was determined for the exhaust clouds. Composition, morphology, surface chemistry, and particle size distributions were determined for the exhausted Al2O3. Results determined for the exhaust cloud from the static test firing were complicated by having large amounts of entrained alkaline ground debris (soil) in the lofted cloud. The entrained debris may have contributed to neutralization of in-cloud HCl.

Cofer, W. R., III↗

Heterogeneous phase reactions of Martian volatiles with putative regolith minerals

The chemical reactivity of several minerals thought to be present in Martian fines is tested with respect to gases known in the Martian atmosphere. In these experiments, liquid water is excluded from the system, environmental temperatures are maintained below 0 C, and the solar illumination spectrum is stimulated in the visible and UV using a xenon arc lamp. Reactions are detected by mass spectrometric analysis of the gas phase over solid samples. No reactions were detected for Mars nominal gas over sulfates, nitrates, chloride, nontronite clay, or magnetite. Oxidation was not observed for basaltic glass, nontronite, and magnetite. However, experiments incorporating SO2 gas an expected product of volcanism and intrusive volatile release - gave positive results. Displacement of CO2 by SO2 occurred in all four carbonates tested. These reactions are catalyzed by irradiation with the solar simulator. A calcium nitrate hydrate released NO2 in the presence of SO2. These results have implications for the cycling of atmospheric CO2, H2O, and N2 through the regolith.

Clark, B. C.↗

Mars Sample Return: Considerations for the Curation of Astromaterials from a Restricted Planet

The joint NASA/ESA Mars Sample Return (MSR) campaign is underway. The Perseverance Rover has already collected a returnable sample suite currently cached at Three Forks and the pairs to these samples are stored on the Rover with more compelling samples planned to be collected. The MSR collection would represent the most geologically diverse astromaterial collection ever returned and should provide information on topics ranging from Martian geological and biological history to Martian environmental hazards and in situ resource utilization to support potential human exploration. Although Jezero Crater and the surrounding area are not Mars special regions, the scientific opinion is that Mars as a whole is of significant interest to the process of chemical evolution and/or the origin of life. Therefore, due to possibility, however remote, that the samples could contain extraterrestrial life, MSR is classified as a Category V: Restricted Earth Return mission by the NASA Planetary Protection Office. As a result of this classification, a MSR Sample Receiving Facility (SRF) must not only provide a pristine environment to ensure samples are protected from terrestrial contamination for scientific investigations, but it must also provide high-containment to isolate the samples from Earth’s biosphere until the samples are deemed safe for release and/or sterilized.

Mars Sample Return↗