Search NASASearch

SEARCH · Search NASA

Results for “ground source heat pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

856 records · Page 15

The Development of A Heated-Hybrid Generated Gas Pressurization System for Propellant Tanks

One of the most important considerations in the design of liquid fueled rockets is the method utilized to transfer the propellants from the propellant tanks to the rocket engine. Use of storable liquid propellant propulsion systems, particularly those employing hydrazine as a fuel, facilitates the attractive possibility of employing the monopropellant virtues of the fuel in order to generate gases for pressurization of the propellant tanks.

GAS PRESSURE

The NASA Turbulent Heat Flux Experiments: Summary and Lessons Learned

The Turbulent Heat Flux (THX) experiments were conducted at NASA Glenn Research Center (GRC) in order to collect measurements of velocities and temperatures for computational fluid dynamics (CFD) validation of heated flows, with a focus on propulsion system components. The experiments spanned 5 phases; four of which were conducted in the GRC AeroAcoustic Propulsion Laboratory (AAPL) using the Small Hot Jet Flow Rig (SHJAR). In addition to making velocity measurements with Particle Image Velocimetry (PIV), the THX experiments introduced a new Raman-scattering based capability to measure temperatures. Computational studies were also conducted for each of the experimental configurations, in order to provide a baseline of expected CFD results and conduct an assessment of the capability of various CFD approaches for calculating flows where the turbulent transport of heat was important. Two of the collected sets of data were used for American Institute of Aeronautics and Astronautics (AIAA) Propulsion Aerodynamic Workshops (PAWs). The data set from the 5th phase, collected for heated supersonic jets, was also used to construct new validation cases for the NASA Turbulence Model Resource (TMR). This paper provides an overview of the experiments and associated computations for each of the 5 test phases. Key experimental findings are presented. Lessons learned are provided concerning the effect of computational modeling choice on accuracy of predicting turbulent flows where thermal transport is important. Emphasis is placed on comparing Reynolds- averaged Navier-Stokes approaches with large-eddy simulation approaches. The benefits of utilizing a conjugate heat transfer method in conjunction with CFD solver for film cooling is demonstrated.

RANS

Rechargeable Battery Auto-Cycler Requiring Lower Power and Dissipating Reduced Waste Heat

A battery charger system includes a power supply and a switch connected to the power supply wherein the switch has a first switch half and a second switch half. First and second batteries are selectively connected to the power supply via the switch. The first and second switch halves are moved between a plurality of operational positions to fully charge the first battery, discharge the first battery into the second battery, discharge the second battery into the first battery, and fully charge the second battery.

Hanson, Thomas David

Coding Performance of the Probe-Orbiter-Earth Communication Link

The coding performance of the Probe-Orbiter-Earth communication link is analyzed and compared for several cases. It is assumed that the coding system consists of a convolutional code at the Probe, a quantizer and another convolutional code at the Orbiter, and two cascaded Viterbi decoders or a combined decoder on the ground.

D Divsalar

Galileo Probe Battery System

The conclusions of the Galileo probe battery system are: the battery performance met mission requirements with margin; extensive ground-based and flight tests of batteries prior to probe separation from orbiter provided good prediction of actual entry performance at Jupiter; and the Li-SO2 battery was an important choice for the probe's main power.

Dagarin, B. P.

A Modular Conjugate Heat Transfer Optimization Framework for Thermal Management of Electric Aircraft

Conjugate heat transfer (CHT) analysis and optimization is a powerful method for improving thermal management, as it simultaneously resolves the temperature distribution in both fluid and solid domains. This paper presents a modular, discrete adjoint-based CHT optimization capability integrated within the OpenMDAO/MPhys framework. A unique feature of the proposed framework is its flexibility to extend to multidisciplinary optimization, including aero-structural-thermal applications. The fluid domain is modeled using a finite-volume Computational Fluid Dynamics (CFD) solver, and the solid domain with a conduction heat transfer solver. A mixed Neumann-Dirichlet boundary condition is developed to enable full submersion of the solid geometry within the fluid domain, while ensuring consistent temperature and heat flux coupling at the CHT interface. Gradient-based optimization is performed; the gradients are efficiently computed using the discrete adjoint solvers implemented in DAFoam. To demonstrate the method, this paper considers two cases related to electric aircraft thermal management: a U-bend heat exchanger and an actively cooled battery pack. The U-bend case aims to minimize pressure loss while maximizing heat flux by changing the pipe geometry. The optimized design reduces pressure loss by 52.7% and increases total heat flux by 2.3%. In the battery pack case, a 3-by-3 cell configuration is cooled by ambient airflow, with constant heat generation prescribed in the cells. The battery casing shape serves as the design variable, and the objective function is a weighted sum of pressure loss and pack weight, subject to a maximum temperature constraint. The optimized design achieves a 44.6% reduction in pressure loss and a 1.5% reduction in weight, while satisfying the thermal constraint. To ensure the reliability of the optimized designs, this study validates coarse-mesh, steady-state predictions against fine-mesh unsteady simulations, demonstrating consistency within acceptable errors. This work demonstrates the potential of the developed framework to enable rapid, high-fidelity design of thermal management systems for electric aircraft.

heat transfer

Estimating the Size of Huffman Code Preambles

Data compression via block-adaptive Huffman coding is considered. The compressor consecutively processes blocks of N data symbols, estimates source statistics by computing the relative frequencies of each source symbol in the block, and then synthesizes a Huffman code based on these estimates. In order to let the decompressor know which Huffman code is being used, the compressor must begin the transmission of each compressed block with a short preamble or header file. This file is an encoding of the list n = (n 1 , n 2 ....,n m ), where n i is the length of the Hufffman codeword associated with the ith source symbol. A simple method of doing this encoding is to individually encode each n i into a fixed-length binary word of length log 2 l, where l is an a priori upper bound on the codeword length. This method produces a maximum preamble length of mlog 2 l bits. The object is to show that, in most cases, no substantially shorter header of any kind is possible.

R J McEliece

Nuclear Reactor Heat Extraction for Synthetic Fuel Plants

This report looks at the viability and best approach when producing synthetic fuels using heat and power supplied by advanced nuclear energy systems. The report looks at a low temperature integration pathway with four types of advanced reactors: a pressurized water reactor (PWR), an advanced light water reactor (A-LWR), a sodium fast reactor (SFR), and a high-temperature gas-cooled reactor (HTGR). A failure modes and effects analysis (FMEA) of the coupling system between the nuclear plant and the synthetic fuel systems is performed with the goal of identifying the reliability of such a thermal delivery system. Furthermore, a high temperature pathway is investigated for synfuel coupling to determine if this is more efficient and more cost effective as a coupling approach.

10 - SYNTHETIC FUELS

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

Harness Thermal Heat Loss Measurement for a Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

Thermal

Harness Thermal Heat Loss Measurement for A Lunar Surface-Deployed LEMS Artemis III Payload

The Lunar Environment Monitoring Station (LEMS) is an autonomous, survive-the-lunar-night seismic suite to be deployed on the Lunar surface by the Artemis III crew and designed to operate continuously for two years. It will see the extremes of the Lunar south pole thermal environment where surface temperatures range from -200°C to +20°C and where nighttime duration is at least 354 hours. Given power and mass constraints, the thermal system is limited to 2.5 Watts of heat during the lunar night. The electrical harnessing named the Signal and Power Passthrough (SAPP) was designed to minimize heat loss while meeting power and signal integrity requirements. To mitigate risk due to uncertainty associated with the harnessing materials, routing, and tie-downs, a flight-like thermal conductance test was performed to measure the heat loss. The test methodology, results, and model correlation are presented.

TVAC

The Design and Use of Calorimeters For Characterization of High-Enthalpy Flows in Arc-Heated Test Facilities

High-enthalpy, arc-heated flows used for aerothermal testing present a challenging environment for flow characterization. This paper describes the design and use of cooled dwell probes used for heat-transfer and pressure characterization of the NASA and United States Department of Defense (DoD) arc facilities located at Moffett Field, CA, and Arnold Air Force Base, TN. Dwell calorimeters designed, fabricated, and tested by Thermal Technologies, Inc. (TTI) in the NASA IHF and the USAF H1 and H2 arc test facilities provide heat flux and pressure data with excellent repeatability. These calorimeters use standard Gardon calorimeter gages and pressure ports with unique cooling systems enabling them to withstand the severe arc-heated environments for durations sufficient for acquisition of steady-state data. The TTI probes have proven very robust in the extreme aerothermal environments of these facilities. This paper provides an overview of calorimeter instruments typically used in arc facilities, discusses design features of the TTI dwell probes, presents selected data acquired by the TTI calorimeters, and provides comparisons with data acquired from using measurement techniques.

D Mark Smith

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe