Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

3D automatic anatomy segmentation based on iterative graph-cut-ASM

Purpose: This paper studies the feasibility of developing an automatic anatomy segmentation (AAS) system in clinical radiology and demonstrates its operation on clinical 3D images. Methods: The AAS system, the authors are developing consists of two main parts: object recognition and object delineation. As for recognition, a hierarchical 3D scale-based multiobject method is used for the multiobject recognition task, which incorporates intensity weighted ball-scale (b-scale) information into the active shape model (ASM). For object delineation, an iterative graph-cut-ASM (IGCASM) algorithm is proposed, which effectively combines the rich statistical shape information embodied in ASM with the globally optimal delineation capability of the GC method. The presented IGCASM algorithm is a 3D generalization of the 2D GC-ASM method that they proposed previously in Chen et al.[Proc. SPIE, 7259, 72590C1-72590C-8 (2009)]. The proposed methods are tested on two datasets comprised of images obtained from 20 patients (10 male and 10 female) of clinical abdominal CT scans, and 11 foot magnetic resonance imaging (MRI) scans. The test is for four organs (liver, left and right kidneys, and spleen) segmentation, five foot bones (calcaneus, tibia, cuboid, talus, and navicular). The recognition and delineation accuracies were evaluated separately. The recognition accuracy was evaluated in terms of translation, rotation, and scale (size) error. The delineation accuracy was evaluated in terms of true and false positive volume fractions (TPVF, FPVF). The efficiency of the delineation method was also evaluated on an Intel Pentium IV PC with a 3.4 GHZ CPU machine. Results: The recognition accuracies in terms of translation, rotation, and scale error over all organs are about 8 mm, 10 deg. and 0.03, and over all foot bones are about 3.5709 mm, 0.35 deg. and 0.025, respectively. The accuracy of delineation over all organs for all subjects as expressed in TPVF and FPVF is 93.01% and 0.22%, and all foot bones for all subjects are 93.75% and 0.28%, respectively. While the delineations for the four organs can be accomplished quite rapidly with average of 78 s, the delineations for the five foot bones can be accomplished with average of 70 s. Conclusions: The experimental results showed the feasibility and efficacy of the proposed automatic anatomy segmentation system: (a) the incorporation of shape priors into the GC framework is feasible in 3D as demonstrated previously for 2D images; (b) our results in 3D confirm the accuracy behavior observed in 2D. The hybrid strategy IGCASM seems to be more robust and accurate than ASM and GC individually; and (c) delineations within body regions and foot bones of clinical importance can be accomplished quite rapidly within 1.5 min.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Potential for Bayesian Compressive Sensing to Significantly Reduce Electron Dose in High Resolution STEM Images

The use of high resolution imaging methods in the scanning transmission electron microscope (STEM) is limited in many cases by the sensitivity of the sample to the beam and the onset of electron beam damage (for example in the study of organic systems, in tomography and during in-situ experiments). To demonstrate that alternative strategies for image acquisition can help alleviate this beam damage issue, here we apply compressive sensing via Bayesian dictionary learning to high resolution STEM images. These experiments successively reduce the number of pixels in the image (thereby reducing the overall dose while maintaining the high resolution information) and show promising results for reconstructing images from this reduced set of randomly collected measurements. We show that this approach is valid for both atomic resolution images and nanometer resolution studies, such as those that might be used in tomography datasets, by applying the method to images of strontium titanate and zeolites. As STEM images are acquired pixel by pixel while the beam is scanned over the surface of the sample, these post acquisition manipulations of the images can, in principle, be directly implemented as a low-dose acquisition method with no change in the electron optics or alignment of the microscope itself.

compressive sensing↗

Exploration of target molecules for molecular imaging of inflammatory bowel disease

Highlights: {sup {yields}18}F-FDG PET could discriminate each inflamed area of IBD model mice clearly. {sup {yields}18}F-FDG PET could not discriminate the difference of pathogenic mechanism. {yields} Cytokines and cytokine receptors expression was different by pathogenic mechanism. {yields} Cytokines and cytokine receptors would be new target molecules for IBD imaging. -- Abstract: Molecular imaging technology is a powerful tool for the diagnosis of inflammatory bowel disease (IBD) and the efficacy evaluation of various drug therapies for it. However, it is difficult to elucidate directly the relationships between the responsible molecules and IBD using existing probes. Therefore, the development of an alternative probe that is able to elucidate the pathogenic mechanism and provide information on the appropriate guidelines for treatment is earnestly awaited. In this study, we investigated pathognomonic molecules in the intestines of model mice. The accumulation of fluorine-18 fluorodeoxyglucose ({sup 18}F-FDG) in the inflamed area of the intestines of dextran sulfate sodium (DSS)- or indomethacin (IND)-induced IBD model mice was measured by positron emission tomography (PET) and autoradiography to confirm the inflamed area. The results suggested that the inflammation was selectively induced in the colons of mice by the administration of DSS, whereas it was induced mainly in the ilea and the proximal colons of mice by the administration of IND. To explore attractive target molecules for the molecular imaging of IBD, we evaluated the gene expression levels of cytokines and cytokine receptors in the inflamed area of the intestines of both model mice. We found that the expression levels of cytokines and cytokine receptors were significantly increased during the progression of IBD, whereas the expression levels were decreased as the mucosa began to heal. In particular, the expression levels of these molecules had already changed before the symptoms of IBD appeared. In addition, the alterations of cytokine and cytokine receptor expression levels indicated differences in the expression pattern depending on the pathogenic mechanism or the region of inflammation (e.g., TNF-{alpha}). Our results suggest that these cytokines or cytokine receptors participate in the pathogenesis of IBD and are valuable biomarkers for the detection of the different circumstances underlying inflammation by the molecular imaging method. Finally, the development of an imaging probe for our target molecules is expected to improve our understanding of the inflammatory conditions of IBD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sub-millimeter resolution electrical conductivity images of brain tissues using magnetic resonance-based electrical impedance tomography

Recent magnetic resonance (MR)-based electrical impedance tomography (MREIT) of in vivo animal and human subjects enabled the imaging of electromagnetic properties, such as conductivity and permittivity, on tissue structure and function with a few millimeter pixel size. At those resolutions, the conductivity contrast might be sufficient to distinguish different tissue type for certain applications. Since the precise measurement of electrical conductivity under the tissue levels can provide alternative information in a wide range of biomedical applications, it is necessary to develop high-resolution MREIT technique to enhance its availability. In this study, we provide the experimental evaluation of sub-millimeter resolution conductivity imaging method using a 3T MR scanner combined with a multi-echo MR pulse sequence, multi-channel RF coil, and phase optimization method. From the phantom and animal imaging results, sub-millimeter resolution exhibited similar signal-to-noise ratio of MR magnitude and noise levels in magnetic flux density comparing to the existing millimeter resolution. The reconstructed conductivity images at sub-millimeter resolution can distinguish different brain tissues with a pixel size as small as 350 μm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging the dome of Santa Maria del Fiore using cosmic rays

The dome of Santa Maria del Fiore, Florence Cathedral, was built between 1420 and 1436 by architect Filippo Brunelleschi and it is now cracking under its own weight. Engineering efforts are under way to model the dome's structure and reinforce it against further deterioration. According to some scholars, Brunelleschi might have built reinforcement structures into the dome itself; however, the only known reinforcement is a wood chain 7.75 m above the springing of the Cupola. Multiple scattering muon radiography is a non-destructive imaging method that can be used to image the interior of the dome's wall and therefore ascertain the layout and status of any iron substructure in it. A demonstration measurement was performed at the Los Alamos National Laboratory on a mock-up wall to show the feasibility of the work proposed, and a lightweight and modular imaging system is currently under construction. Here, we will discuss here the results of the demonstration measurement and the potential of the proposed technique, describe the imaging system under construction and outline the plans for the measurement.

47 OTHER INSTRUMENTATION↗

Seismic Waveform Inversion Capability on Resource-Constrained Edge Devices

Seismic full wave inversion (FWI) is a widely used non-linear seismic imaging method used to reconstruct subsurface velocity images, however it is time consuming, has high computational cost and depend heavily on human interaction. Recently, deep learning has accelerated it’s use in several data-driven techniques, however most deep learning techniques suffer from overfitting and stability issues. In this work, we propose an edge computing-based data-driven inversion technique based on supervised deep convolutional neural network to accurately reconstruct the subsurface velocities. Deep learning based data-driven technique depends mostly on bulk data training. In this work, we train our deep convolutional neural network (DCN) (UNet and InversionNet) on the raw seismic data and their corresponding velocity models during the training phase to learn the non-linear mapping between the seismic data and velocity models. The trained network is then used to estimate the velocity models from new input seismic data during the prediction phase. The prediction phase is performed on a resource-constrained edge device such as Raspberry Pi. Raspberry Pi provides real-time and on-device computational power to execute the inference process. In addition, we demonstrate robustness of our models to perform inversion in the presence on noise by performing both noise-aware and no-noise training and feeding the resulting trained models with noise at different signal-to-noise (SNR) ratio values. We make great efforts to achieve very feasible inference times on the Raspberry Pi for both models. Specifically, the inference times per prediction for UNet and InversionNet models on Raspberry Pi were 22 and 4 s respectively whilst inference times for both models on the GPU were 2 and 18 s which are very comparable. Finally, we have designed a user-friendly interactive graphical user interface (GUI) to automate the model execution and inversion process on the Raspberry Pi.

Manu, Daniel (ORCID:0000000154982677)↗

Method for large and rapid terahertz imaging

A method of large-scale active THz imaging using a combination of a compact high power THz source (>1 watt), an optional optical system, and a camera for the detection of reflected or transmitted THz radiation, without the need for the burdensome power source or detector cooling systems required by similar prior art such devices. With such a system, one is able to image, for example, a whole person in seconds or less, whereas at present, using low power sources and scanning techniques, it takes several minutes or even hours to image even a 1 cm.times.1 cm area of skin.

47 OTHER INSTRUMENTATION↗

Specifications of EBR-II Neutron Radiography Method Description and Digitization Approach

All neutron radiography (NRAD) images of fuel pins in Argonne’s collection were originally generated using the NRAD imaging facility established in the Hot Fuel Examination Facility (HFEF) at Idaho National Laboratory (INL). The NRAD reactor facility was built in 1977 and has been operating since. The reactor is a TRIGA-type reactor operating at a power level of 250 kWth to provide a neutron source for radiography imaging. The reactor is equipped with two beam tubes (i.e., east beam tube and north beam tube) to guide the neutron beams to two radiography stations. The east radiography station is directly under the HFEF main cell and is dedicated for specimens already in the HFEF hot cell. The north radiography station is outside of the main HFEF hot cell and allows NRAD imaging of non-irradiated items. The NRAD images of EBR-II irradiated metallic fuel pins were taken in the east radiography station. Thermal neutrons have the capability to transmit through most materials and are ideal for NRAD imaging. However, because of their high thermal neutron absorption cross-section, fissile materials (e.g., highly-enriched nuclear fuels) may not be as transmissible to thermal neutrons. This is also the case for oversize specimens with extraneous thickness. Epithermal neutron imaging is therefore used as a complement to thermal neutron NRAD imaging. At HFEF’s NRAD facility, both thermal and epithermal neutrons can be used for NRAD imaging. Irradiated nuclear fuels emit high levels of γ radiation that can easily darken X-ray films, so direct exposure NRAD cannot be used to image them. Instead, an indirect NRAD imaging method was developed at HFEF’s NRAD facility. In this method, foils made of materials that can be activated by neutrons (i.e., with large neutron absorption cross section) are used to collect transmitted neutron signals. Then the activated foils are then placed against X-ray films and enclosed in a vacuum cassette so that the γ decay from the activated foils can produce images on the X-ray films. Then, general X-ray film processing procedures are used to digitize and store the images. By using different foil materials, different energy neutrons can be used for NRAD imaging. At the HFEF NRAD station, two types of films are commonly used: dysprosium (Dy) foils with thickness of 130 microns are used to capture thermal neutron signal, while indium (In) foils with thickness of 130 microns are used to capture epithermal neutron signal. A cadmium or gadolinium foil is put before the indium foil to work as a thermal neutron filter. The thermal and epithermal NRAD images can be taken simultaneously by using a Dy/Cd/In sandwiched foil combination. The typical NRAD exposure time is approximately 20 minutes. Then the exposed foils are transferred to film vacuum cassettes. The vacuum ensures that there is no gap between the foil and the film. The foil-to-film exposure time is at least three half-lives of the corresponding radioisotopes, which are 3 hours for In and 7.5 hours for Dy, respectively. Exposed films are processed using an automatic film processor to produce completed NRAD images.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Directly imaging steeply-dipping fault zones in geothermal fields with multicomponent seismic data

For characterizing geothermal systems, it is important to have clear images of steeply-dipping fault zones because they may confine the boundaries of geothermal reservoirs and influence hydrothermal flow. Elastic reverse-time migration (ERTM) is the most promising tool for subsurface imaging with multicomponent seismic data. However, conventional ERTM usually generates significant artifacts caused by the cross correlation of undesired wavefields and the polarity reversal of shear waves. In addition, it is difficult for conventional ERTM to directly image steeply-dipping fault zones. We develop a new ERTM imaging method in this paper to reduce these artifacts and directly image steeply-dipping fault zones. In our new ERTM method, forward-propagated source wavefields and backward-propagated receiver wavefields are decomposed into compressional (P) and shear (S) components. Furthermore, each component of these wavefields is separated into left- and right-going, or downgoing and upgoing waves. The cross correlation imaging condition is applied to the separated wavefields along opposite propagation directions. For converted waves (P-to-S or S-to-P), the polarity correction is applied to the separated wavefields based on the analysis of Poynting vectors. Numerical imaging examples of synthetic seismic data demonstrate that our new ERTM method produces high-resolution images of steeply-dipping fault zones.

58 GEOSCIENCES↗

SU-F-J-114: On-Treatment Imagereconstruction Using Transit Images of Treatment Beams Through Patient and Thosethrough Planning CT Images

Purpose: To reconstruct patient images at the time of radiation delivery using measured transit images of treatment beams through patient and calculated transit images through planning CT images. Methods: We hypothesize that the ratio of the measured transit images to the calculated images may provide changed amounts of the patient image between times of planning CT and treatment. To test, we have devised lung phantoms with a tumor object (3-cm diameter) placed at iso-center (simulating planning CT) and off-center by 1 cm (simulating treatment). CT images of the two phantoms were acquired; the image of the off-centered phantom, unavailable clinically, represents the reference on-treatment image in the image quality of planning CT. Cine-transit images through the two phantoms were also acquired in EPID from a non-modulated 6 MV beam when the gantry was rotated 360 degrees; the image through the centered phantom simulates calculated image. While the current study is a feasibility study, in reality our computational EPID model can be applicable in providing accurate transit image from MC simulation. Changed MV HU values were reconstructed from the ratio between two EPID projection data, converted to KV HU values, and added to the planning CT, thereby reconstructing the on-treatment image of the patient limited to the irradiated region of the phantom. Results: The reconstructed image was compared with the reference image. Except for local HU differences>200 as a maximum, excellent agreement was found. The average difference across the entire image was 16.2 HU. Conclusion: We have demonstrated the feasibility of a method of reconstructing on-treatment images of a patient using EPID image and planning CT images. Further studies will include resolving the local HU differences and investigation on the dosimetry impact of the reconstructed image.

60 APPLIED LIFE SCIENCES↗

A Method to Recognize Anatomical Site and Image Acquisition View in X-ray Images

A method was developed to recognize anatomical site and image acquisition view automatically in 2D X-ray images that are used in image-guided radiation therapy. The purpose is to enable site and view dependent automation and optimization in the image processing tasks including 2D-2D image registration, 2D image contrast enhancement, and independent treatment site confirmation. The X-ray images for 180 patients of six disease sites (the brain, head-neck, breast, lung, abdomen, and pelvis) were included in this study with 30 patients each site and two images of orthogonal views each patient. A hierarchical multiclass recognition model was developed to recognize general site first and then specific site. Each node of the hierarchical model recognized the images using a feature extraction step based on principal component analysis followed by a binary classification step based on support vector machine. Given two images in known orthogonal views, the site recognition model achieved a 99% average F1 score across the six sites. If the views were unknown in the images, the average F1 score was 97%. If only one image was taken either with or without view information, the average F1 score was 94%. The accuracy of the site-specific view recognition models was 100%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-speed quantitative X-ray multi-contrast imaging with deep learning based modulated pattern analysis

The advent of X-ray multi-contrast imaging methods, providing absorption, phase, and dark-field images, holds tremendous promise for complementary and non-destructive visualization of inner structures within materials and bio-samples. However, the low efficiency in measuring and analyzing X-ray modulated patterns has hindered their application in high-resolution in situ imaging. In this work, the Enhanced Scanning Pattern-based Imaging Neural Network (ESPINNet) is introduced as a powerful tool for achieving high-speed, high-resolution quantitative imaging. ESPINNet is faster than correlation-based speckle tracking methods such as XSVT and UMPA, and provides a balanced performance in terms of resolution and speed for data collection by using fewer scanning images. In comparison with our previously developed neural network, ESPINNet introduces the capability to generate dark-field images, further enhancing its versatility. By leveraging scanning patterns, ESPINNet significantly improves resolution and measurement precision. Furthermore, its adaptability to various modulation patterns, including those produced by sandpaper, coded masks, or gratings, ensures broad applicability. These features enable real-time 2D and 3D multi-contrast imaging, positioning ESPINNet as a transformative solution for applications in materials science and biomedical research, particularly for high-speed and in situ measurements.

X-ray at-wavelength metrology↗

Three-dimensional multiphase segmentation of X-ray CT data of porous materials using a Bayesian Markov random field framework

Advancements in noninvasive imaging methods such as X-ray computed tomography (CT) have led to a recent surge of applications in porous media research with objectives ranging from theoretical aspects of pore-scale fluid and interfacial dynamics to practical applications such as enhanced oil recovery and advanced contaminant remediation. While substantial efforts and resources have been devoted to advance CT technology, microscale analysis, and fluid dynamics simulations, the development of efficient and stable three-dimensional multiphase image segmentation methods applicable to large data sets is lacking. To eliminate the need for wet-dry or dual-energy scans, image alignment, and subtraction analysis, commonly applied in X-ray micro-CT, a segmentation method based on a Bayesian Markov random field (MRF) framework amenable to true three-dimensional multiphase processing was developed and evaluated. Furthermore, several heuristic and deterministic combinatorial optimization schemes required to solve the labeling problem of the MRF image model were implemented and tested for computational efficiency and their impact on segmentation results. Test results for three grayscale data sets consisting of dry glass beads, partially saturated glass beads, and partially saturated crushed tuff obtained with synchrotron X-ray micro-CT demonstrate great potential of the MRF image model for three-dimensional multiphase segmentation. While our results are promising and the developed algorithm is stable and computationally more efficient than other commonly applied porous media segmentation models, further potential improvements exist for fully automated operation.

42 ENGINEERING↗

System and method for generating motion corrected tomographic images

A method and related system for generating motion corrected tomographic images includes the steps of illuminating a region of interest (ROI) to be imaged being part of an unrestrained live subject and having at least three spaced apart optical markers thereon. Simultaneous images are acquired from a first and a second camera of the markers from different angles. Motion data comprising 3D position and orientation of the markers relative to an initial reference position is then calculated. Motion corrected tomographic data obtained from the ROI using the motion data is then obtained, where motion corrected tomographic images obtained therefrom.

47 OTHER INSTRUMENTATION↗

Superresolution Diffuse Optical Imaging by Localization of Fluorescence

The multiple scattering of light presents major challenges in realizing useful in vivo imaging at tissue depths of more than about one millimeter, where many answers to health questions lie. Visible through near-infrared photons can be readily and safely detected through centimeters of tissue; however, limited information is available for image formation. One strategy for obtaining images is to model the photon transport and a simple incoherent model is the diffusion equation approximation to the Boltzmann transport equation. Such an approach provides a prediction of the mean intensity of heavily scattered light and hence provides a forward model for optimization-based computational imaging. While diffuse optical imaging methods have received substantial attention, they remain restricted in terms of resolution because of the loss of high-spatial-frequency information that is associated with the multiple scattering of photons. Consequently, only relatively large inhomogeneities, such as tumors or organs in small animals, can be effectively resolved. We introduce a superresolution imaging approach based on point localization in a diffusion framework that enables over two orders of magnitude improvement in the spatial resolution of diffuse optical imaging. The method is demonstrated experimentally by localizing a fluorescent inhomogeneity in a highly scattering slab and characterizing the localization uncertainty. The approach allows imaging through centimeters of tissue with a resolution of tens of microns, thereby enabling cells or cell clusters to be resolved. More generally, this high-resolution imaging approach could be applied with any physical transport or wave model and hence to a broad class of physical problems. Finally, paired with a suitable optical contrast mechanism, as can be realized with targeted fluorescent molecules or genetically modified animals, superresolution diffuse imaging should open alternative dimensions for in vivo applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Super-resolution Bioimaging using Massively Entangled Multimode Squeezed Light

This report presents a new method for realizing a super-resolution quantum imaging using massively entangled multimode squeezed light (MEMSL). Each branch of the entangled multimode light interacts with the sample and bears the spatially varying optical phase delay. When imaging optics with finite pupil sizes are used, information is lost. Thanks to the analyticity in the Fourier plane, a noiseless measurement would recover the lost information and accomplish super resolution imaging beating the Rayleigh diffraction limit. I proved rigorously in a fully quantum formalism and presented that (1) such information recovery is possible and (2) the information recovery can be accomplished with much less resources when MEMSL is used than those needed in any non-entangled or non-squeezed classical imaging method. Furthermore, the action of the optical loss in the imaging system that degrades the imaging performance is also rigorously analyzed and presented. Several bioimaging applications that can benefit tremendously from the proposed quantum imaging scheme are also suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Our teams design high-resolution MeV x-ray radiography systems for National security missions [Poster]

The NNSS has been at the forefront of custom high-fidelity x-ray/gamma radiographic imaging solutions that serve our national security for over five decades. Our radiography team utilizes expertise in physics modeling and analysis, along with optical, mechanical, and electrical design, in close collaboration with our customers, to develop imaging methods and capabilities that go beyond their needs. Conceptual designs are developed through R&D efforts to provide solutions for the specific problem at hand. Field systems are designed and built in-house, then qualified utilizing a range of facilities across the National Security Enterprise. Radiographic imaging systems are deployed by our team in the most challenging environments. The NNSS has a strong math and programming team that provides novel on-site image analysis methods that extract crucial information from data returned in field tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard X-ray nanoimaging method using local diffraction from metal wire

A simple hard X-ray imaging method achieving a high spatial resolution is proposed. Images are obtained by scanning a metal wire through the wave field to be measured and rotating the sample to collect data for back projection calculations; the local diffraction occurring at the edges of the metal wire operates as a narrow line probe. In-line holograms of a test sample were obtained with a spatial resolution of better than 100 nm. The potential high spatial resolution of this method is shown by calculations using diffraction theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗