At least 271 records · Page 15

Determining Directions of Ultrasound in Solids

Ultrasound shadows cast by grooves. Improved method for determining direction of ultrasound in materials is shadow method using Scanning laser acoustic microscopy (SLAM). Direction of ultrasound calculated from dimensions of groove and portion of surface groove shields from ultrasound. Method has variety of applications in nontraditional quality-control applications.

Generazio, Edward R.↗

Flow tracing fidelity of scattering aerosol in laser Doppler velocimetry

An experimental method for determinating the flow tracing fidelity of a scattering aerosol used in laser Doppler velocimeters was developed with particular reference to the subsonic turbulence measurements. The method employs the measurement of the dynamic response of a flow seeding aerosol excited by acoustic waves. The amplitude and frequency of excitation were controlled to simulate the corresponding values of fluid turbulence components. Experimental results are presented on the dynamic response of aerosols over the size range from 0.1 to 2.0 microns in diameter and over the frequency range 100 Hz to 100 kHz. It was observed that unit density spherical scatterers with diameters of 0.2 microns followed subsonic air turbulence frequency components up to 100 kHz with 98 percent fidelity.

Mazumder, M. K.↗

Quantitative Measurements of Nitric Oxide Concentration in High-Pressure, Swirl-Stabilized Spray Flames

Lean direct-injection (LDI) spray flames offer the possibility of reducing NO(sub x) emissions from gas turbines by rapid mixing of the liquid fuel and air so as to drive the flame structure toward partially-premixed conditions. We consider the technical approaches required to utilize laser-induced fluorescence methods for quantitatively measuring NO concentrations in high-pressure LDI spray flames. In the progression from atmospheric to high-pressure measurements, the LIF method requires a shift from the saturated to the linear regime of fluorescence measurements. As such, we discuss quantitative, spatially resolved laser-saturated fluorescence (LSF), linear laser-induced fluorescence (LIF), and planar laser-induced fluorescence (PLIF) measurements of NO concentration in LDI spray flames. Spatially-resolved LIF measurements of NO concentration (ppm) are reported for preheated, LDI spray flames at pressures of two to five atmospheres. The spray is produced by a hollow-cone, pressure-atomized nozzle supplied with liquid heptane. NO is excited via the Q(sub 2)(26.5) transition of the gamma(0,0) band. Detection is performed in a two nanometer region centered on the gamma(0,1) band. A complete scheme is developed by which quantitative NO concentrations in high-pressure LDI spray flames can be measured by applying linear LIF. NO is doped into the reactants and convected through the flame with no apparent destruction, thus allowing a NO fluorescence calibration to be taken inside the flame environment. The in-situ calibration scheme is validated by comparisons to a reference flame. Quantitative NO profiles are presented and analyzed so as to better understand the operation of lean-direct injectors for gas turbine combustors. Moreover, parametric studies are provided for variations in pressure, air-preheat temperature, and equivalence ratio. Similar parametric studies are performed for lean, premixed-prevaporized flames to permit comparisons to those for LDI flames. Finally, PLIF is expanded to high pressure in an effort to quantify the detected fluorescence image for LDI flames. Success is achieved by correcting the PLIF calibration via a single-point LIF measurement. This procedure removes the influence of any preferential background that occurs in the PLIF detection window. In general, both the LIF and PLIF measurements verify that the LDI strategy could be used to reduce NO(sub x) emissions in future gas turbine combustors.

Cooper, Clayton S.↗

Diagnostics of Carbon Nanotube Formation in a Laser Produced Plume: An Investigation of the Metal Catalyst by Laser Ablation Atomic Fluorescence Spectroscopy

Carbon nanotubes, elongated molecular tubes with diameters of nanometers and lengths in microns, hold great promise for material science. Hopes for super strong light-weight material to be used in spacecraft design is the driving force behind nanotube work at JSC. The molecular nature of these materials requires the appropriate tools for investigation of their structure, properties, and formation. The mechanism of nanotube formation is of particular interest because it may hold keys to controlling the formation of different types of nanotubes and allow them to be produced in much greater quantities at less cost than is currently available. This summer's work involved the interpretation of data taken last summer and analyzed over the academic year. The work involved diagnostic studies of carbon nanotube formation processes occurring in a laser-produced plume. Laser ablation of metal doped graphite to produce a plasma plume in which carbon nanotubes self assemble is one method of making carbon nanotube. The laser ablation method is amenable to applying the techniques of laser spectroscopy, a powerful tool for probing the energies and dynamics of atomic and molecular species. The experimental work performed last summer involved probing one of the metal catalysts, nickel, by laser induced fluorescence. The nickel atom was studied as a function of oven temperature, probe laser wavelength, time after ablation, and position in the laser produced plume. This data along with previously obtained data on carbon was analyzed over the academic year. Interpretations of the data were developed this summer along with discussions of future work. The temperature of the oven in which the target is ablated greatly influences the amount of material ablated and the propagation of the plume. The ablation conditions and the time scale of atomic and molecular lifetimes suggest that initial ablation of the metal doped carbon target results in atomic and small molecular species. The metal atoms survive for several milliseconds while the gaseous carbon atoms and small molecules nucleate more rapidly. Additional experiments and the development of in situ methods for carbon nanotube detection would allow these results to be interpreted from the perspective of carbon nanotube formation.

deBoer, Gary↗

First Single-Crystal Mullite Fibers

Ceramic-matrix composites strengthened by suitable fiber additions are being developed for high-temperature use, particularly for aerospace applications. New oxide-based fibers, such as mullite, are particularly desirable because of their resistance to high-temperature oxidative environments. Mullite is a candidate material in both fiber and matrix form. The primary objective of this work was to determine the growth characteristics of single-crystal mullite fibers produced by the laser-heated floating zone method. Directionally solidified fibers with nominal mullite compositions of 3Al2O3 2SiO2 were grown by the laser-heated floating zone method at the NASA Lewis Research Center. SEM analysis revealed that the single-crystal fibers grown in this study were strongly faceted and that the facets act as critical flaws, limiting fiber strength. The average fiber tensile strength is 1.15 GPa at room temperature. The mullite fibers exhibit superior strength retention (80 percent of their room temperature tensile strength at 1450 C). Examined by transmission electron microscopy, these mullite single crystals are free of dislocations, low-angle boundaries, and voids. In addition, they show a high degree of oxygen vacancy ordering. High-resolution digital images from an optical microscope furnish evidence of the formation of a liquid-liquid miscibility gap during crystal growth. These images represent the first experimental evidence of liquid immiscibility for these compositions and temperatures. Continuing investigation with controlled seeding of mullite single crystals is planned.

Source record↗

Sensitive detection of Escherichia coli O157:H7 in food and water by immunomagnetic separation and solid-phase laser cytometry

Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.

Non-NASA Center↗

Compositional and Microstructural Evolution of Olivine During Pulsed Laser Irradiation: Insights Based on a FIB/Field-Emission TEM Study

Introduction: The use of pulsed laser irradiation to simulate the short duration, high-energy conditions characteristic of micrometeorite impacts is now an established approach in experimental space weathering studies. The laser generates both melt and vapor deposits that contain nanophase metallic Fe (npFe(sup 0)) grains with size distributions and optical properties similar to those in natural impact-generated melt and vapor deposits. There remains uncertainty, however, about how well lasers simulate the mechanical work and internal (thermal) energy partitioning that occurs in actual impacts. We are currently engaged in making a direct comparison between the products of laser irradiation and experimental/natural hypervelocity impacts. An initial step reported here is to use analytical TEM is to attain a better understanding of how the microstructure and composition of laser deposits evolve over multiple cycles of pulsed laser irradiation. Experimental Methods: We irradiated pressed-powder pellets of San Carlos olivine (Fo(sub 90)) with up to 99 rastered pulses of a GAM ArF excimer laser. The irradiated surface of the sample were characterized by SEM imaging and areas were selected for FIB cross sectioning for TEM study using an FEI Quanta dual-beam electron/focused ion beam instrument. FIB sections were characterized using a JEOL2500SE analytical field-emission scanning transmission electron microscope (FE-STEM) optimized for quantitative element mapping at less than 10 nm spatial resolutions. Results: In the SEM the 99 pulse pressed pellet sample shows a complex, inhomogeneous, distribution of laser-generated material, largely concentrated in narrow gaps and larger depressions between grains. Local concentrations of npFe0 spherules 0.1 to 1 micrometers in size are visible within these deposits in SEM back-scatter images. Fig. 1 shows bright-field STEM images of a FIB cross-section of a one of these deposits that continuously covers the top and sloping side of an olivine grain. The deposit has 3 microstructurally distinct sub-layers composed of silicate glass with varying modal fractions and size distributions of npFe( sup 0) spherules, along with nanocrystalline silicate material. A relatively thin (50-300 nm) topmost surface layer has a high-concentration of npFe0 spherules 5-20 nm in size. Element mapping shows the layer to be enriched in Fe by a factor of 2.5 relative to the olivine substrate, with Mg and Si depleted by 20% and 10% respectively. This is compositionally complementary to the underlying, middle layer of the deposit that is depleted in Fe, enriched in Mg and has a much lower npFe0 concentration. A third layer of nanocrystalline olivine occurs at the substrate interface. Discussion: The FE-STEM results suggest the topmost layer is a vapor deposit, underlain by a thicker microstructurally complex melt-generated layer. The compositional relations suggest the melt layer was partially vaporized, preferentially losing more volatile elements (e.g., Fe). The vaporized material re-condensed to form the thin, npFe(sup 0)-rich surface deposit during or immediately after the scan cycle. Nanocrystalline olivine that grew within the melt layer as it formed and cooled is similar in volume and microstructure to what we have observed in the impact melt lining of a micrometeorite impact crater in olivine. This suggest the time-temperature relations attained in the laser sample may not be too different from a micrometeorite impact. Our TEM observations, however, do not show evidence for the same level of mechanical dam-age (e.g., fracturing) seen around the natural micrometeorite crater.

Christoffersen, R.↗

Laser Angioplasty

The principal method of dealing with coronary artery blockage is bypass surgery. A non-surgical alternative available to some patients is balloon angioplasty. For several years, medical researchers have been exploring another alternative that would help a wider circle of patients than the balloon treatment and entail less risk than bypass surgery. A research group is on the verge of an exciting development: laser angioplasty with a 'cool' type of laser, called an excimer laser, that does not damage blood vessel walls and offers non-surgical cleansing of clogged arteries with extraordinary precision. The system is the Dymer 200+ Excimer Laser Angioplasty System, developed by Advanced Intraventional Systems. Used in human clinical tests since 1987, the system is the first fully integrated 'cool' laser capable of generating the requisite laser energy and delivering the energy to target arteries. Thirteen research hospitals in the U.S. have purchased Dymer 200+ systems and used them in clinical trials in 121 peripheral and 555 coronary artery cases. The success rate in opening blocked coronary arteries is 85 percent, with fewer complications than in balloon angioplasty. Food and Drug Administration approval for the system is hoped for in the latter part of 1990. * Advanced Intraventional Systems became Spectranetics in 1994 and discontinued the product.

Source record↗

Future directions for H sub x O sub y detection, executive summary

New methods for the measurement of OH radicals were assessed as were currently available and possible future methods for the other H sub x O sub y species, HO2 and H2O2. The workshop participants were invited from different groups: modelers of atmospheric photochemistry, experimentalists measuring H sub x O y species with laser and nonlaser methods, and chemists and physicists familiar with such experiments but not involved in atmospheric monitoring. There were three major conclusions from the workshop concerning the OH radical. First, it was felt that local measurements made by laser techniques would be ready within 2 or 3 years to furnish reliable measurements at the level of 1,000,000 cu. cm. Second, measurements at this level of sensitivity and with attainable levels of precision could indeed be used to make useful and interesting tests of the fast photochemistry of the troposphere. It is important, however, that the measurements be carefully designed, with respect to spatial and temporal averaging, if there is to be a meaningful comparison between results from two experimental methods or a measurement and a model. Third, nonlocal measurements using released reactants and tracers would also be very useful. These could be made on a regional or global basis, although they still require experimental design including choice of compounds.

Source record↗

A new, improved method for separating turbulent boundary layer for aerodynamic performance prediction of trailing edge stall airfoils

A method based on integral techniques is presented to determine the turbulent separation location and separation pressure for trailing edge stall airfoils exhibiting extensive separated flow regions during prestall and poststall conditions. The method and experimental laser velocimetry data in the turbulence amplification region are used to establish a relationship between fluctuating velocity components and mean velocity in the boundary layer. The method is demonstrated for symmetrical, cambered, conventional and supercritical airfoils in the 5-to-21-percent thickness ratio range, and over a Reynolds number range of 2 to 22 million. Good agreement with experimental data is found, and the method is used in conjunction with the NASA Multi-Component Airfoil Computer Program to predict maximum L/D ratios and maximum section/lift coefficients.

Goradia, S.↗

Methods for obtaining and reducing experimental droplet impingement data on arbitrary bodies

Experimental water droplet impingement data are used to validate particle trajectory computer codes used in the analysis and certification of aircraft de-icing/anti-icing systems. Water droplet impingement characteristics of aerodynamic surfaces are usually obtained from wind-tunnel dye tracer experiments. This paper presents a dye tracer method for measuring water droplet impingement characteristics on arbitrary geometries and a new data reduction method, based on laser reflectance measurements, for extracting impingement data. Extraction of impingement data has been a very time-consuming process in the past. The new data reduction method developed is at least an order of magnitude more efficient than the method previously used. The accuracy of the method is discussed and results obtained are presented.

Papadakis, Michael↗

Evaluation of an Alternate Method for Determining Yield Strength Offset Values for Selective Laser Sintered Polymeric Materials

Due to the unique characteristics of Additively Manufactured (AM) polymeric materials, typical mechanical strength characterization methods such as those commonly used for traditionally-processed polymers or composite materials can produce results that do not accurately represent material capabilities. In order to characterize mechanical properties of these materials, new test and analysis methods are required. As part of the National Aeronautics and Space Administration (NASA) Advanced Composites Project (ACP), Boeing has evaluated true yield testing as an alternative or complimentary test to 0.2% offset yield testing for determining appropriate yield strength values of polymer materials. Previous testing has shown high strain, low modulus polymer materials such as selective laser sintered (SLS) Nylon 11 at elevated temperatures produce large variations in yield strength. The true yield test method was successful in finding the applied strain level when yield commences and appears to offer an increase in data robustness.

Henry, Chelsey↗

Advancement of High Power Quasi-CW Laser Diode Arrays For Space-based Laser Instruments

Space-based laser and lidar instruments play an important role in NASA s plans for meeting its objectives in both Earth Science and Space Exploration areas. Almost all the lidar instrument concepts being considered by NASA scientist utilize moderate to high power diode-pumped solid state lasers as their transmitter source. Perhaps the most critical component of any solid state laser system is its pump laser diode array which essentially dictates instrument efficiency, reliability and lifetime. For this reason, premature failures and rapid degradation of high power laser diode arrays that have been experienced by laser system designers are of major concern to NASA. This work addresses these reliability and lifetime issues by attempting to eliminate the causes of failures and developing methods for screening laser diode arrays and qualifying them for operation in space.

Amzajerdian, Farzin↗

A modified equivalent-width technique for diode-laser line strength measurements

A modified equivalent-width method is introduced that improves the accuracy of spectral line strength measurements using diode lasers. This method differs from the standard method in that no attempt is made to calculate the true equivalent width in order to determine the line strength. Instead, the line strength is derived directly from a measurement of the area under the line close to the line center and ignore the normal correction terms. Tests with actual spectra and simulations indicate that this method is accurate to better than 1 percent with lines broadened by up to 50 percent by the laser instrument function.

Strow, L. Larrabee↗

A method of atmospheric density measurements during Shuttle entry using UV laser Rayleigh scattering

A detailed study is described of the performance capabilities and the hardware requirements for a method in which ambient density is measured along the Space Shuttle flight path using on-board optical instrumentation. The technique relies on Rayleigh scattering of light from a pulsed, ultraviolet, ArF excimer laser operating at a wavelength of 193 nm. The method is shown to be capable of providing direct measurements of ambient density with an uncertainty of less than 1 percent and with a spatial resolution of 1 km, over an altitude range from 50 to 90 km. In addition, extensions of this concept are discussed that allow measurements of the shock wave location and the density profile within the shock layer. Two approaches are identified that appear to be feasible, in which the same laser system is used for the extended measurements as that required for the ambient density measurements.

Mckenzie, Robert L.↗

Flow tracing fidelity of scattering aerosol in laser Doppler velocimetry

An experimental method for the determination of the flow-tracing fidelity of a scattering aerosol used in laser Doppler velocimeters was developed with particular reference to the subsonic turbulence measurements. The method employs the measurement of the dynamic response of a flow-seeding aerosol excited by acoustic waves. The amplitude and frequency of excitation were controlled in order to simulate the corresponding values of fluid turbulence components. Experimental results are presented on the dynamic response of aerosols over the size range from 0.1 to 2.0 microns in diam and over the frequency range 100 Hz to 100 kHz. It was observed that unit-density spherical scatterers with diameters of 0.2 micron followed subsonic air turbulence frequency components up to 100 kHz with 98% fidelity.

Mazumder, M. K.↗

Rapid laser induced energy transfer in atomic systems

Analytical and experimental studies of the rapid transfer of stored populations from metastable states to selected target states of a different species are reported. Both laser-induced or laser-switched collision and laser-induced two-photon spontaneous emission are described. It is shown that the laser-induced collision method is particularly useful in the visible and UV spectral regions. It has applications in photochemistry, gas-phase kinetics, and in high-power, high-energy gas-phase lasers. The anti-Stokes source is useful in the VUV and soft X-ray spectral regions.

Harris, S. E.↗

Measurements of temperature, density, pressure, and their fluctuations in supersonic turbulence using laser-induced fluorescence

A laser-induced fluorescence method has been developed that provides simultaneous measurements of temperature, density, and their fluctuations owing to turbulence in unheated compressible flows. Pressure and its fluctuations are also deduced using the equation of state. Fluorescence is induced in nitric oxide that has been seeded into a nitrogen flow in concentrations of 100 ppm. Measurements are obtained from each laser pulse, with a spatial resolution of 1 mm and a temporal resolution of 125 ns. The method was applied to a supersonic, turbulent, boundary-layer flow with a free-stream Mach number of 2. For stream conditions in the range from 150-300 K and 0.3-1 atm, temperature is measured with an uncertainty of approximately 1 percent rms, while density and pressure uncertainties are approximately 2 percent rms.

Gross, K. P.↗