Search NASA⌕ Search

SEARCH · Search NASA

Results for “microfluidic device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Flow-Assisted Selective Mineral Extraction from Seawater

The sustainable production of critical materials from natural sources requires a paradigm shift away from currently used resource-intensive processes. In this paper, we report a single-step, laminar co-flow method (LCM) that leverages non-equilibrium conditions to selectively extract pure Mg(OH) 2 from natural seawater. Conventional seawater-based Mg extraction involves adding individual or a combination of precipitants to obtain Mg(OH) 2 , but the co-existence of Ca 2+ unavoidably results in CaCO 3 impurities requiring additional purification steps. Here we show that the non-equilibrium conditions in LCM achieved using a microfluidics device and by simply co-injecting a NaOH solution with seawater can result in improved selectivity for Mg(OH) 2 unlike in conventional bulk mixing method. The resulting precipitates are characterized for composition and the process yield and purity are optimized through systematic variations of the reaction time and the concentration of NaOH. This is the first demonstration of LCM for selective separation, and as a one-step process that does not rely on novel sorbents, membranes, or external stimuli, it is easy to scale-up. LCM has the potential to be broadly relevant to selective separations from complex feed streams and diverse chemistries—enabling more sustainable materials extraction and processing.

54 ENVIRONMENTAL SCIENCES↗

Electroosmotic Flow Rectification in Membranes with Asymmetrically Shaped Pores: Effects of Current and Pore Density

We have recently demonstrated a new electrokinetic phenomenon—electroosmotic flow rectification in membranes with asymmetrically shaped pores. Flow rectification means that at constant driving force the flow rate in one direction through the membrane is faster than the flow rate in the opposite direction. EOF rectification could be of practical use in microfluidic devices incorporating porous membranes, but additional research is required. As such, we explore here the effects of two key experimental variables—current density used to drive flow through the membrane and membrane pore density—on EOF rectification. We have found that the extent of EOF rectification, as quantified by the rectification ratio, increases with increasing current density. In contrast, the rectification ratio decreases with increasing membrane pore density. We propose explanations for these results based on simple EOF and membrane-transport theories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence Signatures of Rare Earth Metals during Precipitation in Various Conditions

Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.

fluorescence↗

A Limiting Case of Constant Counterion Electrochemical Potentials in the Membrane for Examining Ion Transfer at Ion-Exchange Membranes and Patches

We present that ion passage through ion-exchange membranes is vital in electrodialysis desalination, batteries and fuel cells, and water splitting. Simplified models of ion transport through such membranes frequently assume complete exclusion of coions (ions with the same sign of charge as the fixed charge in the membrane) from the membrane. However, a second assumption of constant counterion electrochemical potentials across the membrane leads to simple analytical expressions for ion fluxes and transmembrane potentials. Moreover, linear corrections to account for a small membrane electrical resistance yield analytical expressions with a wider applicability. For bi-ionic potential measurements and current-induced concentration polarization at low salt concentrations, these analytical solutions match the fluxes and potentials obtained numerically without the limiting assumptions. This gives confidence in both the limiting assumptions (under appropriate conditions) and the numerical solutions. At low ion concentrations, the analytical solutions may enable rapid characterization of membrane coatings or boundary layers in solution, and such boundary layers are important in many applications of ion-exchange membranes. In fact, the assumption of complete coion exclusion is sometimes more limiting than the constraint of constant electrochemical potentials of counterions across the membrane. Remarkably, this limiting case readily yields the ion accumulation and depletion regions above “ion-exchange patches” that reside beneath a solution with an applied electric field. Finally, such regions are important for sample pre-concentration in microfluidic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing Fluorescence-Based Sensors to Support Rare Earth Element Separation

Rare earth elements (REEs) are essential to most renewable energy technologies. Unfortunately, as we transition to sustainable energy production, the demand for REEs is rapidly growing well beyond current rates of production. As a result, novel means of efficient, scalable, and easily adaptable methods for processing primary and recycle feedstocks are needed. Development and integration of sensors for highly selective in-line monitoring can support more efficient design and testing of such novel separation processes, as well as more cost-effective deployment of those separation flowsheets. Work here will explore the application of fluorescence spectroscopy, a highly sensitive and selective technique, to quantify multiple lanthanides in complex mixtures including known interferents or quenching agents. Results include identification of the optimal excitation wavelength and the limit of detection of various rare earth elements as well as the performance of data-science-based quantification approaches in streams where “unknowns” are present. Overall, the data science tools in conjunction with optical sensor data were able to quantify analytes in the presence of other lanthanides which can be anticipated in the actual industrial stream. Here we include characterization of lanthanides in a microfluidic device similar to those used in new process development. This study demonstrates the capability of utilizing fluorescence spectroscopy to quantify analytes in a complicated solution matrix, suggesting this is a successful approach for in-line monitoring to optimize the separation efficiency in an industrial stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sequestration, fluorometric detection, and mass spectroscopy analysis of lanthanide ions using surface modified magnetic microspheres for microfluidic manipulation.

Several methods for rapid sequestration, fluorometric detection, and the subsequent mass spectroscopic analysis of lanthanide ions using surface modified polystyrene magnetic microspheres are demonstrated. Mixed-ligand antenna complexes of Eu{sup 3+} in which one of the ligands is attached to the surface of the microspheres have been used as a means for the sequestration, immobilization, and detection of these ions. Using the ion-exchange properties of these microspheres, this scheme has been extended to the detection of nonluminescent ions. The principles of these assays form the basis for operation of a portable microfluidic device for general analytical and nuclear forensics applications and indicate the manner in which the established methods of analytical chemistry, such as liquid-liquid extraction and ion-exchange chromatography, can be adapted for such miniature devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoresponsive Structured Liquids Enabled by Molecular Recognition at Liquid–Liquid Interfaces

Using host-guest molecular recognition at the oil-water interface, a new type of photoresponsive nanoparticle surfactant (NPS) was designed and prepared to structure liquids. With the help of a polymeric surfactant, the interfacial host-guest interactions can be significantly enhanced, leading to the rapid formation and assembly of a NP monolayer and offering sufficient binding energy to hold the NPs in a jammed state. The assembly of the NPSs can be reversibly manipulated via a photoswitchable jamming-to-unjamming transition, endowing the interface as well as the macroscopic assemblies with responsiveness to the external trigger (photons). Finally, this study for the first time opens a pathway for the construction of multiresponsive, structured all-liquid systems by introducing host-guest chemistry, showing promising potential applications in encapsulation, delivery systems, and unique microfluidic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tailored Silicon Nanopost Arrays for Resonant Nanophotonic Ion Production

Nanostructures that have dimensions commensurate with the wavelength of the electromagnetic radiation exhibit near-field effects1,2 and, as optical antennas, can couple laser radiation to the local environment3. Laser-induced silicon microcolumn arrays behave as nanophotonic ion sources that can be modulated by rotating the plane of light polarization4,5. Here we demonstrate that nanopost arrays (NAPA) can be tailored to exhibit resonant ion production. Ion yields from posts with subwavelength diameter show sharp resonances at high aspect ratios. The resonant enhancement in ion intensities can be modulated by adjusting the periodicity. In addition to strong molecular ion formation, the presence of high energy fragmentation channels is observed. Ion yields from NAPA exhibit dramatic differences for p- and s-polarized laser beams, indicating that energy coupling is similar to antenna arrays. These nanophotonic ion sources can control the degree of ion fragmentation and could eventually be integrated with micromachined mass spectrometers and microfluidic devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Harnessing catalytic pumps for directional delivery of microparticles in microchambers

The directed transport of microparticles in microfluidic devices is vital for efficient bioassays and fabrication of complex microstructures. There remains, but, a need for methods to propel and steer microscopic cargo that do not require modifying these particles. By using theory and experiments, we show that catalytic surface reactions can be used to deliver microparticle cargo to specified regions in microchambers. Here reagents diffuse from a gel reservoir and react with the catalyst-coated surface. Fluid density gradients due to the spatially varying reagent concentration induce a convective flow, which carries the suspended particles until the reagents are consumed. Consequently, the cargo is deposited around a specific position on the surface. The velocity and final peak location of the cargo can be tuned independently. And by increasing the local particle concentration, highly sensitive assays can be performed efficiently and rapidly. Moreover, the process can be repeated by introducing fresh reagent into the microchamber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scalable and automated CRISPR-based strain engineering using droplet microfluidics

Abstract We present a droplet-based microfluidic system that enables CRISPR-based gene editing and high-throughput screening on a chip. The microfluidic device contains a 10 × 10 element array, and each element contains sets of electrodes for two electric field-actuated operations: electrowetting for merging droplets to mix reagents and electroporation for transformation. This device can perform up to 100 genetic modification reactions in parallel, providing a scalable platform for generating the large number of engineered strains required for the combinatorial optimization of genetic pathways and predictable bioengineering. We demonstrate the system’s capabilities through the CRISPR-based engineering of two test cases: (1) disruption of the function of the enzyme galactokinase ( galK ) in E. coli and (2) targeted engineering of the glutamine synthetase gene ( glnA ) and the blue-pigment synthetase gene ( bpsA ) to improve indigoidine production in E. coli .

42 ENGINEERING↗

Self-mixing in microtubule-kinesin active fluid from nonuniform to uniform distribution of activity

Active fluids have applications in micromixing, but little is known about the mixing kinematics of systems with spatiotemporally-varying activity. To investigate, UV-activated caged ATP is used to activate controlled regions of microtubule-kinesin active fluid and the mixing process is observed with fluorescent tracers and molecular dyes. At low Péclet numbers (diffusive transport), the active-inactive interface progresses toward the inactive area in a diffusion-like manner that is described by a simple model combining diffusion with Michaelis-Menten kinetics. At high Péclet numbers (convective transport), the active-inactive interface progresses in a superdiffusion-like manner that is qualitatively captured by an active-fluid hydrodynamic model coupled to ATP transport. Results show that active fluid mixing involves complex coupling between distribution of active stress and active transport of ATP and reduces mixing time for suspended components with decreased impact of initial component distribution. This work will inform application of active fluids to promote micromixing in microfluidic devices.

59 BASIC BIOLOGICAL SCIENCES↗

Cellular fluidics

The natural world provides many examples of multiphase transport and reaction processes that have been optimized by evolution. These phenomena take place at multiple length and time scales and typically include gas–liquid–solid interfaces and capillary phenomena in porous media. Many biological and living systems have evolved to optimize fluidic transport. However, living things are exceptionally complex and very difficult to replicate, and human-made microfluidic devices (which are typically planar and enclosed) are highly limited for multiphase process engineering. In this paper, we introduce the concept of cellular fluidics: a platform of unit-cell-based, three-dimensional structures—enabled by emerging 3D printing methods—for the deterministic control of multiphase flow, transport and reaction processes. We show that flow in these structures can be ‘programmed’ through architected design of cell type, size and relative density. We demonstrate gas–liquid transport processes such as transpiration and absorption, using evaporative cooling and CO 2 capture as examples. We design and demonstrate preferential liquid and gas transport pathways in three-dimensional cellular fluidic devices with capillary-driven and actively pumped liquid flow, and present examples of selective metallization of pre-programmed patterns. Our results show that the design and fabrication of architected cellular materials, coupled with analytical and numerical predictions of steady-state and dynamic behaviour of multiphase interfaces, provide deterministic control of fluidic transport in three dimensions. Cellular fluidics may transform the design space for spatial and temporal control of multiphase transport and reaction processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Timescale Separation of Positive and Negative Signaling Creates History-Dependent Responses to IgE Receptor Stimulation

The high-affinity receptor for IgE expressed on the surface of mast cells and basophils interacts with antigens, via bound IgE antibody, and triggers secretion of inflammatory mediators that contribute to allergic reactions. To understand how past inputs (memory) influence future inflammatory responses in mast cells, a microfluidic device was used to precisely control exposure of cells to alternating stimulatory and non-stimulatory inputs. We determined that the response to subsequent stimulation depends on the interval of signaling quiescence. For shorter intervals of signaling quiescence, the second response is blunted relative to the first response, whereas longer intervals of quiescence induce an enhanced second response. Through an iterative process of computational modeling and experimental tests, we found that these memory-like phenomena arise from a confluence of rapid, short-lived positive signals driven by the protein tyrosine kinase Syk; slow, long-lived negative signals driven by the lipid phosphatase Ship1; and slower degradation of Ship1 co-factors. This work advances our understanding of mast cell signaling and represents a generalizable approach for investigating the dynamics of signaling systems.

59 BASIC BIOLOGICAL SCIENCES↗

A centrifugal microfluidic cross-flow filtration platform to separate serum from whole blood for the detection of amphiphilic biomarkers

Abstract The separation of biomarkers from blood is straightforward in most molecular biology laboratories. However, separation in resource-limited settings, allowing for the successful removal of biomarkers for diagnostic applications, is not always possible. The situation is further complicated by the need to separate hydrophobic signatures such as lipids from blood. Herein, we present a microfluidic device capable of centrifugal separation of serum from blood at the point of need with a system that is compatible with biomarkers that are both hydrophilic and hydrophobic. The cross-flow filtration device separates serum from blood as efficiently as traditional methods and retains amphiphilic biomarkers in serum for detection.

59 BASIC BIOLOGICAL SCIENCES↗

A mathematical framework for thermodynamic computing with applications to chemical reaction networks

The widespread adoption of energy-intensive computing applications has led to a growing need for energy-efficient computing approaches. Thermodynamic computing offers a promising approach for low-energy computation by leveraging the intrinsic computational capabilities of physical, chemical, or biological systems. However, the mathematical foundations of thermodynamic computing require further development to fully realize the potential energy efficiencies, as well as to assess factors like noise and operational speed. In this paper, we establish a mathematical framework for utilizing thermodynamic processes to perform fundamental operations, including addition, subtraction, multiplication, and division. We highlight the use of chemical reactions as potential computational units and explore synthetic chemical and biochemical systems as practical implementations. Additionally, we demonstrate how these principles can be applied to solving complex mathematical problems, such as ordinary differential equations (ODEs) and suggest the necessary components to implement the thermodynamic computing framework using chemical reactions based in a microfluidic device. This work enhances our understanding of thermodynamic processes for natural computing as a basis for scalable, energy-efficient computation in paradigm disruptive next-generation systems.

Cannon, William R. [Pacific Northwest National Lab↗

Single cell swimming dynamics of Listeria monocytogenes using a nanoporous microfluidic platform

Listeria monocytogenes remains a significant foodborne pathogen due to its virulence and ability to become established in food processing facilities. The pathogen is characterized by its ability to grow over a wide temperature range and withstand a broad range of stresses. The following reports on the chemotaxis and motility of the L. monocytogenes when exposed to relatively small concentrations of acetic acid. Using the developed nanoporous microfluidic device to precisely modulate the cellular environment, we exposed the individual Listeria cells to acetic acid and, in real time and with high resolution, observed how the cells reacted to the change in their surroundings. Our results showed that concentrations of acetic acid below 10 mM had very little, if any, effect on the motility. However, when exposed to 100 mM acetic acid, the cells exhibited a sharp drop in velocity and displayed a more random pattern of motion. These results indicate that at appropriate concentrations, acetic acid has the ability to disable the flagellum of the cells, thus impairing their motility. This drop in motility has numerous effects on the cell; its main effects being the obstruction of the cell's ability to properly form biofilms and a reduction in the overall infectivity of the cells. Since these characteristics are especially useful in controlling the proliferation of L. monocytogenes, acetic acid shows potential for application in the food industry as an active compound in designing a food packaging environment and as an antimicrobial agent.

Wright, Evan↗

Molecular evidence of toxic effect on the biofilm and its matrix

The biofilm and its extracellular polymeric substance (EPS) are known to respond to toxic chemicals. Shewanella oneidensis MR-1 wild-type (WT) and a hyper-adhesive mutant CP2-1-S1 (CP) are used as model organisms and Cr(VI) is selected as a toxic chemical in this study. We investigate the following the science questions: 1) what are the chemical differences revealed in molecular mapping between WT and CP; and 2) how WT and CP biofilms respond to a toxic chemical. The System for Analysis at the Liquid Vacuum Interface (SALVI) is employed for in situ chemical imaging of live biofilms using time-of-flight secondary ion mass spectrometry (ToF-SIMS). The SIMS spectra and principal component analysis (PCA) are used to study the biofilm spatial and chemical heterogeneity. In situ measurement of biofilm metabolic responses to toxic chemicals has been given for the first time. The method presented here is expected to be viable to study responses to other chemicals including antimicrobials in the context of antimicrobial resistance to biofilms with diverse applications.

biofilm, Shewanella oneidensis, CP2-1-S1, SALVI, T↗

Liquid interfaces with pH-switchable nanoparticle arrays

Stimuli-responsive 2D nanoscale systems offer intriguing opportunities for creating switchable interfaces. At liquid interfaces, such systems can provide control over interfacial energies, surface structure, and rheological and transport characteristics, which is relevant, for example, to bio- and chemical reactors, microfluidic devices, and soft robotics. We explore the formation of a pH-responsive membrane formed from gold nanoparticles grafted with DNA (DNA–NPs) at a liquid–vapor interface. A DNA–NP 2D hexagonal lattice can be reversibly switched by pH modulation between an expanded state of non-connected nanoparticles at neutral pH and a contracted state of linked nanoparticles at acidic pH due to the AH + –H + A base pairing between A-motifs. Our in situ surface X-ray scattering studies reveal that the reversible lattice contraction can be tuned by the length of pH-activated linkers, with up to ~71% change in surface area.

59 BASIC BIOLOGICAL SCIENCES↗