A machine learning framework for accurate and robust analysis of radiation detector pulses

The microscopic properties of atomic nuclei are used to study various scientific questions. They are essential for understanding the fundamental forces of nature and the chemical evolution of the universe. Detecting decay radiation from radioactive nuclei makes it possible to probe these fundamental nuclear properties. Detector waveform traces may contain additional information about the radiation. Generally, advanced signal processing techniques are needed to extract this additional information, often involving fitting the waveform with model response functions using non-linear least-squares optimization with second-order gradient methods. While this is a powerful technique, it is also computationally expensive, leading to slow processing time, which scales with the volume of data. To address this problem, we have developed a machine learning (ML) approach that infers the characteristics of traces from a model detector response function. In particular, we are interested in classifying whether a single recorded trace consists of one or two pulse constituents and estimating the pulse parameters. Furthermore, our proposed ML method can precisely extract the pulses’ parameters, such as energy and timing information, and accurately classify the pulse multiplicity of a trace. Unlike non-learning-based approaches, our ML approach uses neural networks that are significantly faster at inference, as they do not require any optimization during this stage.

Curve fitting↗

Super-resolution and segmentation deep learning for breast cancer histopathology image analysis

Traditionally, a high-performance microscope with a large numerical aperture is required to acquire high-resolution images. However, the images’ size is typically tremendous. Therefore, they are not conveniently managed and transferred across a computer network or stored in a limited computer storage system. As a result, image compression is commonly used to reduce image size resulting in poor image resolution. Here, we demonstrate custom convolution neural networks (CNNs) for both super-resolution image enhancement from low-resolution images and characterization of both cells and nuclei from hematoxylin and eosin (H&E) stained breast cancer histopathological images by using a combination of generator and discriminator networks so-called super-resolution generative adversarial network-based on aggregated residual transformation (SRGAN-ResNeXt) to facilitate cancer diagnosis in low resource settings. The results provide high enhancement in image quality where the peak signal-to-noise ratio and structural similarity of our network results are over 30 dB and 0.93, respectively. The derived performance is superior to the results obtained from both the bicubic interpolation and the well-known SRGAN deep-learning methods. In addition, another custom CNN is used to perform image segmentation from the generated high-resolution breast cancer images derived with our model with an average Intersection over Union of 0.869 and an average dice similarity coefficient of 0.893 for the H&E image segmentation results. Finally, we propose the jointly trained SRGAN-ResNeXt and Inception U-net Models, which applied the weights from the individually trained SRGAN-ResNeXt and inception U-net models as the pre-trained weights for transfer learning. The jointly trained model’s results are progressively improved and promising. We anticipate these custom CNNs can help resolve the inaccessibility of advanced microscopes or whole slide imaging (WSI) systems to acquire high-resolution images from low-performance microscopes located in remote-constraint settings.

60 APPLIED LIFE SCIENCES↗

Long term storage test of titanium material with liquid fluorine propellant

The compatibility of 6AL-4V Ti with propellant grade GF2 and LF2 at 77 K for up to 3 years was investigated. Titanium double coupons, annealed or heat treated, with 16 or 64 RMS finishes, were immersed in F2 in individual Pyrex capsules and stored under LN2 for 29 and 39 months. Pre and post immersion tests were performed on the propellant and coupons. Chemical analysis of the propellant did not reveal any significant changes due to titanium corrosion. Gravimetric, visual, microscopic, and metallurgical examination with pitting analysis did not reveal gross corrosion of the titanium although pitting appears to be greater after 39 months exposure. The increase in pit size and number raises the possibility of unpredictable crack propagation instability. Fracture toughness tests are necessary to define this possibility.

Denson, J. R.↗

Microscopic theory of onset of decaging and bond-breaking activated dynamics in ultradense fluids with strong short-range attractions

We theoretically study thermally activated “in cage” elementary dynamical processes that precede full structural relaxation in ultra-dense particle liquids interacting via strong short range attractive forces. The analysis is based on a microscopic theory formulated at the particle trajectory level built on the dynamic free energy concept and an explicit treatment of how attractive forces control the formation and lifetime of physical bonds. Mean time scales for bond breaking, the early stage of cage escape, and non-Fickian displacement by a fixed amount are analyzed in the repulsive glass, bonded repulsive (attractive) glass, fluid, and dense gel regimes. The theory predicts a strong length-scale-dependent growth of these time scales with attractive force strength at fixed packing fraction, a much weaker slowing down with density at fixed attraction strength, and a strong decoupling of the shorter bond breaking time with the other two time scales that are controlled mainly by perturbed steric caging. All results are in good accord with simulations, and additional testable predictions are made. In conclusion, the classic statistical mechanical projection approximation of replacing all bare attractive and repulsive forces with a single effective force determined by pair structure incurs major errors for describing processes associated with thermally activated escape from transiently localized states.

36 MATERIALS SCIENCE↗

Current Problems in X-Ray Emission Spectroscopy

Various problems that limit X-ray analysis in the analytical electron microscope are reviewed. Major emphasis is given to the trade-off between minimum mass fraction and spatial resolution. New developments such as high-brightness electron guns, new X-ray spectrometers and clean high-vacuum analysis conditions will lead to major improvements in the accuracy and detectability limits of X-ray emission spectroscopy.

Goldstein, Joseph I.↗

Machine learning for automated experimentation in scanning transmission electron microscopy

Abstract Machine learning (ML) has become critical for post-acquisition data analysis in (scanning) transmission electron microscopy, (S)TEM, imaging and spectroscopy. An emerging trend is the transition to real-time analysis and closed-loop microscope operation. The effective use of ML in electron microscopy now requires the development of strategies for microscopy-centric experiment workflow design and optimization. Here, we discuss the associated challenges with the transition to active ML, including sequential data analysis and out-of-distribution drift effects, the requirements for edge operation, local and cloud data storage, and theory in the loop operations. Specifically, we discuss the relative contributions of human scientists and ML agents in the ideation, orchestration, and execution of experimental workflows, as well as the need to develop universal hyper languages that can apply across multiple platforms. These considerations will collectively inform the operationalization of ML in next-generation experimentation.

36 MATERIALS SCIENCE↗

Environmental fatigue of an Al-Li-Cu alloy. Part 2: Microscopic hydrogen cracking processes

Based on a fractographic analysis of fatigue crack propagation (FCP) in Al-Li-Cu alloy 2090 stressed in a variety of inert and embrittling environments, microscopic crack paths are identified and correlated with intrinsic da/dN-delta K kinetics. FCP rates in 2090 are accelerated by hydrogen producing environments (pure water vapor, moist air, and aqueous NaCl), as defined in Part 1. For these cases, subgrain boundary fatigue cracking (SGC) dominates for delta K values where the crack tip process zone, a significant fraction of the cyclic plastic zone, is sufficiently large to envelop 5 micron subgrains in the unrecrystallized microstructure. SGC may be due to strong hydrogen trapping at T1 precipitates concentrated at sub-boundaries. At low delta K, the plastic zone diameter is smaller than the subgrain size and FCP progresses along (100) planes due to either local lattice decohesion or aluminum-lithium hydride cracking. For inert environments (vacuum, helium, and oxygen), or at high delta K where the hydrogen effect on da/dN is small, FCP is along (111) slip planes; this mode does not transition with increasing delta K and plastic zone size. The SGC and (100) crystallographic cracking modes, and the governing influence of the crack tip process zone volume (delta K), support hydrogen embrittlement rather than a surface film rupture and anodic dissolution mechanism for environmental FCP. Multi-sloped log da/dN-log delta K behavior is produced by changes in process zone hydrogen-microstructure interactions, and not by purely micromechanical-microstructure interactions, in contradiction to microstructural distance-based fatigue models.

Robert S Piascik↗

Physical and Chemical Characterization of Particles in the Upper Troposphere and Lower Stratosphere: Microanalysis of Aerosol Impactor Samples

Herein is reported activities to support the characterization of the aerosol in the upper troposphere (UT) and lower stratosphere (LS) collected during the Airborne Southern Hemisphere Ozone Experiment/Measurements for Assessing the Effects of Stratospheric Aircraft (ASHOE/MAESA) missions in 1994. Through a companion proposal, another group was to measure the size distribution of aerosols in the 0.008 to 2 micrometer diameter range and to collect for us impactor samples of particles larger than about 0.02 gm. In the first year, we conducted laboratory studies related to particulate deposition patterns on our collection substrates, and have performed the analysis of many ASHOE/MAESA aerosol samples from 1994 using analytical electron microscopy (AEM). We have been building an "aerosol climatology" with these data that documents the types and relative abundances of particles observed at different latitudes and altitudes. The second year (and non-funded extension periods) saw continued analyses of impactor aerosol samples, including more ASHOE/MAESA samples, some northern hemisphere samples from the NASA Stratospheric Photochemistry Aerosols and Dynamics Expedition (SPADE) program for comparison, and a few aerosol samples from the NASA Stratospheric TRacers of Atmospheric Transport (STRAT) program. A high-resolution field emission microscope was used for the analysis and re-analysis of a number of samples to determine if this instrument was superior in performance to our conventional electron microscope. In addition, some basic laboratory studies were conducted to determine the minimum detectable and analyzable particle size for different types of aerosols. In all, 61 aerosol samples were analyzed, with a total of over 30,000 individual particle analyses. In all analyzed samples, sulfate particles comprised the major aerosol number fraction. It must be stressed that particles composed of more than one species, for example sulfate and organic carbon, were classified according to the major fraction. Thus, many of the particles classified as sulfate may have contained significant mass fractions of carbonaceous or other material. These particles for the most part did not show two physical phases, however. Nonsulfate particles were classified according to the physical and chemical characteristics of each particle, and were grouped into the major nonsulfate particle classes, including C-rich, crustal, metallic, and salts. Our UT and LS sample analyses indicate a maximum for crustal and C-rich particle abundance in the Northern Hemisphere upper troposphere, and a salt particle maximum in the Southern Hemisphere upper troposphere. Metallic particles are clearly more prevalent in the troposphere than in the stratosphere, but interhemispheric differences appear small.

Sheridan, Patrick J.↗

Reconstruction of effective potential from statistical analysis of dynamic trajectories

The broad incorporation of microscopic methods is yielding a wealth of information on the atomic and mesoscale dynamics of individual atoms, molecules, and particles on surfaces and in open volumes. Analysis of such data necessitates statistical frameworks to convert observed dynamic behaviors to effective properties of materials. Here, we develop a method for the stochastic reconstruction of effective local potentials solely from observed structural data collected from molecular dynamics simulations (i.e., data analogous to those obtained via atomically resolved microscopies). Using the silicon vacancy defect in graphene as a model, we apply the statistical framework presented herein to reconstruct the free energy landscape from the calculated atomic displacements. Evidence of consistency between the reconstructed local potential and the trajectory data from which it was produced is presented, along with a quantitative assessment of the uncertainty in the inferred parameters.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of Deposits on Glass Substrate as a Tool in Failure Analysis: The Orbiter Vehicle Columbia Case Study

In connection with the accident investigation of the space shuttle Columbia, an analysis methodology utilizing well established microscopic and spectroscopic techniques was implemented for evaluating the environment to which the exterior fused silica glass was exposed. Through the implementation of optical microscopy, scanning electron microscopy, energy dispersive spectroscopy, transmission electron microscopy, and electron diffraction, details emerged regarding the manner in which a charred metallic deposited layer formed on top of the exposed glass. Due to nature of the substrate and the materials deposited, the methodology proved to allow for a more detailed analysis of the vehicle breakup. By contrast, similar analytical methodologies on metallic substrates have proven to be challenging due to strong potential for error resulting from substrate contamination. This information proved to be valuable to not only those involved in investigating the break up of Columbia, but also provides a potential guide for investigating future high altitude and high energy accidents.

Olivas, J. D.↗

Power Electronics Materials and Bonded Interfaces - Reliability and Lifetime

High temperature operation of wide bandgap devices continue to be a challenge for the power electronics packages. Thermal performance and reliability are important factors that determine the viability of a bonded interface for operation at high temperatures. In this presentation, we present the technical approach and key results from the research on sintered silver, transient liquid phase alloy, and polymeric materials. A lifetime prediction model that incorporates the thermomechanical behavior of sintered silver at 200C was developed. The copper-aluminum transient alloy completed 350 thermal cycles from -40C to 200C and little increase in the defect level was observed. In addition to material research, we initiated a time-series analysis on the scanning acoustic microscope images of eutectic solder to explore statistical forecasting methods and machine learning techniques. Initial results that report the accuracy of a few different statistical models are presented.

ADVANCED PROPULSION SYSTEMS↗

Automated Track Recognition and Event Reconstruction in Nuclear Emulsion

The major advantages of nuclear emulsion for detecting charged particles are its submicron position resolution and sensitivity to minimum ionizing particles. These must be balanced, however, against the difficult manual microscope measurement by skilled observers required for the analysis. We have developed an automated system to acquire and analyze the microscope images from emulsion chambers. Each emulsion plate is analyzed independently, allowing coincidence techniques to be used in order to reject back- ground and estimate error rates. The system has been used to analyze a sample of high-multiplicity Pb-Pb interactions (charged particle multiplicities approx. 1100) produced by the 158 GeV/c per nucleon Pb-208 beam at CERN. Automatically reconstructed track lists agree with our best manual measurements to 3%. We describe the image analysis and track reconstruction techniques, and discuss the measurement and reconstruction uncertainties.

Deines-Jones, P.↗

Nanoscale Antiferromagnetic Domain Imaging using Full-Field Resonant X-ray Magnetic Diffraction Microscopy

The physical properties of magnetic materials frequently depend not only on the microscopic spin and electronic structures, but also on the structures of mesoscopic length scales that emerge, for instance, from domain formations, or chemical and/or electronic phase separations. However, experimental access to such mesoscopic structures is currently limited, especially for antiferromagnets with net zero magnetization. Here, full-field microscopy and resonant magnetic X-ray diffraction are combined to visualize antiferromagnetic (AF) domains of the spin–orbit Mott insulator Sr 2 IrO 4 with area over ≈0.1 mm 2 and with spatial resolution as high as ≈150 nm. With the unprecedented wide field of views and high spatial resolution, an intertwining of two AF domains on a length comparable to the measured average AF domain wall width of 545 nm is revealed. This mesoscopic structure comprises a substantial portion of the sample surface, and thus can result in a macroscopic response unexpected from its microscopic magnetic structure. In particular, the symmetry analysis presented in this work shows that the inversion symmetry, which is preserved by the microscopic AF order, becomes ill-defined at the mesoscopic length scale. We report this result underscores the importance of this novel technique for a thorough understanding of the physical properties of antiferromagnets.

36 MATERIALS SCIENCE↗

Fast Image Texture Classification Using Decision Trees

Texture analysis would permit improved autonomous, onboard science data interpretation for adaptive navigation, sampling, and downlink decisions. These analyses would assist with terrain analysis and instrument placement in both macroscopic and microscopic image data products. Unfortunately, most state-of-the-art texture analysis demands computationally expensive convolutions of filters involving many floating-point operations. This makes them infeasible for radiation- hardened computers and spaceflight hardware. A new method approximates traditional texture classification of each image pixel with a fast decision-tree classifier. The classifier uses image features derived from simple filtering operations involving integer arithmetic. The texture analysis method is therefore amenable to implementation on FPGA (field-programmable gate array) hardware. Image features based on the "integral image" transform produce descriptive and efficient texture descriptors. Training the decision tree on a set of training data yields a classification scheme that produces reasonable approximations of optimal "texton" analysis at a fraction of the computational cost. A decision-tree learning algorithm employing the traditional k-means criterion of inter-cluster variance is used to learn tree structure from training data. The result is an efficient and accurate summary of surface morphology in images. This work is an evolutionary advance that unites several previous algorithms (k-means clustering, integral images, decision trees) and applies them to a new problem domain (morphology analysis for autonomous science during remote exploration). Advantages include order-of-magnitude improvements in runtime, feasibility for FPGA hardware, and significant improvements in texture classification accuracy.

Thompson, David R.↗

Random Dopant Induced Threshold Voltage Lowering and Fluctuations in Sub-0.1 (micron)meter MOSFET's: A 3-D 'Atomistic' Simulation Study

A three-dimensional (3-D) "atomistic" simulation study of random dopant induced threshold voltage lowering and fluctuations in sub-0.1 microns MOSFET's is presented. For the first time a systematic analysis of random dopant effects down to an individual dopant level was carried out in 3-D on a scale sufficient to provide quantitative statistical predictions. Efficient algorithms based on a single multigrid solution of the Poisson equation followed by the solution of a simplified current continuity equation are used in the simulations. The effects of various MOSFET design parameters, including the channel length and width, oxide thickness and channel doping, on the threshold voltage lowering and fluctuations are studied using typical samples of 200 atomistically different MOSFET's. The atomistic results for the threshold voltage fluctuations were compared with two analytical models based on dopant number fluctuations. Although the analytical models predict the general trends in the threshold voltage fluctuations, they fail to describe quantitatively the magnitude of the fluctuations. The distribution of the atomistically calculated threshold voltage and its correlation with the number of dopants in the channel of the MOSFET's was analyzed based on a sample of 2500 microscopically different devices. The detailed analysis shows that the threshold voltage fluctuations are determined not only by the fluctuation in the dopant number, but also in the dopant position.

Asenov, Asen↗

Major to trace element imaging and analysis of iron age glasses using stage scanning in the analytical dual beam microscope (tandem)

Dark and clear silicate glasses formed during an iron age vitrification event ≈ 1500 years ago at the Broborg hillfort near Uppsala, Sweden have been analyzed using a scanning electron microscope equipped with a micro-X-ray fluorescence (μXRF) spectrometer. Correlated µXRF and electron beam-induced energy dispersive spectrometry (EDS) X-ray maps were collected via stage-scanning at constant velocity. This coupled procedure represents a new approach for the cultural heritage community to conduct analytical studies of archaeometric specimens composed of metal, ceramic, or mixed inorganic/organic materials, where major and trace element compositions are registered in space for areas up to the centimeter-length scale at micrometer-scale resolution. Overview images were used to select areas for EDS beam scan maps correlated with multispectral cathodoluminescence (CL) imaging and co-located quantitative EDS and μXRF point analysis. Fe, Ca, Mg, Ti, P, Mn, Zr, Zn, and Y are enriched in the dark glass, while Si, Al, K, Na, Ba, Sr, Rb, and Ga are enriched in the clear glass. Unmelted material is comprised predominately of quartz (SiO 2 ) along with trace apatite (Ca 5 (PO 4 ) 3 [Cl,OH]) and zircon (ZrSiO 4 ). Multivariate statistical analysis was used to measure the area fractions of high variance components while lower variance components represented phase mixtures. Differences between calculated melt viscosities for the glass compositions are consistent with field and laboratory observations. Coupled large area EDS and μXRF imaging shows significant promise for informed selection of higher spatial resolution and higher sensitivity follow-up studies, e.g., those performed using synchrotron analysis.

36 MATERIALS SCIENCE↗

Single molecule insights into interfacial molecular recognition for model electrochemical DNA biosensors

Electrochemical sensors that use surface-immobilized DNA to bind analytes and transduce the binding into electrochemical signals, have the potential for rapid, specific, and sensitive detection of bioanalytes via a compact and portable platform. However, accessing the structure of these surfaces/interfaces at the relevant spatial scale (< 10 nm), which determines the interfacial interactions and ultimately sensing performance, remains an unsolved challenge. Here, we review studies that have used high resolution atomic force microscope imaging and spatial statistical analysis tools to understand crowding interactions between thiolated DNA probes immobilized on gold electrodes and how such interactions impact target binding. We also review related studies that attempt to control the nanoscale spatial arrangement of the immobilized recognition elements to optimize sensing performance. Furthermore, these efforts have led to new advances in understanding of the structure-function relationships of DNA-based electrochemical biosensors to move the field toward rational engineering of these biosensing interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Annealing temperature variation and its influence on the self-cleaning properties of TiO 2 thin films

Titanium dioxide (TiO 2 ) is an important material in science and engineering because of its basic and synthetic properties. Nevertheless, there is a dearth of reports in the open literature focusing on its ability to self-clean under temperature changes. In this study, we used the spin coating technique to produce TiO 2 thin films to evaluate its self-cleaning ability after annealing at different temperatures. The TiO 2 sol was obtained through an endothermal sol-gel process, and the gel was coated on a glass substrate using a spin coater. The deposited films were then annealed at 400 °C, 600 °C, and 800 °C for 1 h. The influence of annealing temperature variation on the self-cleaning properties of the thin film was characterized using X-ray diffraction, scanning electron microscope; Fourier transformed infrared spectrometric analysis and UV-vis spectrophotometer. A test to ascertain self-cleaning was conducted using the degradation of methylene blue, and the different films were tested for durability. The durability test confirmed the connection between solid coating and substrate at all annealing temperatures. Thin films annealed at 600 °C revealed the best self-cleaning properties. The morphological analysis revealed snowflake shapes uniformly distributed over the substrate at 400 °C, and agglomeration improved as the annealing temperature increased. Structural analysis showed an increase in crystallinity with an increase in annealing temperature for both rutile and anatase phases. At three different temperatures, the chemical bond and the absorption band pattern followed the same path, although the peak intensity declined with temperature rise. Finally, the optical bandgap of the thin coated TiO 2 declined from 3.39 eV to 3.20 eV as the binding temperature increased from 400 to 800 °C.

36 MATERIALS SCIENCE↗