Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Arrays of membrane isolated yttrium-barium-copper-oxide kinetic inductance bolometers

We are developing of arrays of membrane isolated resonator-bolometers, each with a kinetic inductance device (KID) to measure the temperature of the membrane. The KIDs are fabricated out of the high temperature superconductor YBCO to allow operation at relatively high temperatures. The bolometers are designed to offer higher sensitivity than sensors operating at 300 K, but they require less expensive and lighter weight cooling than even more sensitive conventional superconducting detectors operating at lower temperatures. The bolometer arrays are applicable as focal planes in infrared imaging spectrometers, such as for planetary science missions or earth observing satellites. We describe the devices and present measurements of their sensitivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exploring cosmic origins with CORE: Survey requirements and mission design

Future observations of cosmic microwave background (CMB) polarisation have the potential to answer some of the most fundamental questions of modern physics and cosmology, including: what physical process gave birth to the Universe we see today? What are the dark matter and dark energy that seem to constitute 95% of the energy density of the Universe? Do we need extensions to the standard model of particle physics and fundamental interactions? Is the ΛCDM cosmological scenario correct, or are we missing an essential piece of the puzzle? In this paper, we list the requirements for a future CMB polarisation survey addressing these scientific objectives, and discuss the design drivers of the COREmfive space mission proposed to ESA in answer to the "M5" call for a medium-sized mission. The rationale and options, and the methodologies used to assess the mission's performance, are of interest to other future CMB mission design studies. COREmfive has 19 frequency channels, distributed over a broad frequency range, spanning the 60–600 GHz interval, to control astrophysical foreground emission. The angular resolution ranges from 2' to 18', and the aggregate CMB sensitivity is about 2 μK∙arcmin. The observations are made with a single integrated focal-plane instrument, consisting of an array of 2100 cryogenically-cooled, linearly-polarised detectors at the focus of a 1.2-m aperture cross-Dragone telescope. The mission is designed to minimise all sources of systematic effects, which must be controlled so that no more than 10 -4 of the intensity leaks into polarisation maps, and no more than about 1% of E-type polarisation leaks into B-type modes. COREmfive observes the sky from a large Lissajous orbit around the Sun-Earth L2 point on an orbit that offers stable observing conditions and avoids contamination from sidelobe pick-up of stray radiation originating from the Sun, Earth, and Moon. The entire sky is observed repeatedly during four years of continuous scanning, with a combination of three rotations of the spacecraft over different timescales. With about 50% of the sky covered every few days, this scan strategy provides the mitigation of systematic effects and the internal redundancy that are needed to convincingly extract the primordial B-mode signal on large angular scales, and check with adequate sensitivity the consistency of the observations in several independent data subsets. COREmfive is designed as a "near-ultimate" CMB polarisation mission which, for optimal complementarity with ground-based observations, will perform the observations that are known to be essential to CMB polarisation science and cannot be obtained by any other means than a dedicated space mission. It will provide well-characterised, highly-redundant multi-frequency observations of polarisation at all the scales where foreground emission and cosmic variance dominate the final uncertainty for obtaining precision CMB science, as well as 2' angular resolution maps of high-frequency foreground emission in the 300–600 GHz frequency range, essential for complementarity with future ground-based observations with large telescopes that can observe the CMB with the same beamsize.

79 ASTRONOMY AND ASTROPHYSICS↗

Testing Gravity with Realistic Gravitational Waveforms in Pulsar Timing Arrays

We consider the effects of relaxing the assumption that gravitational waves composing the stochastic gravitational wave background (SGWB) are uncorrelated between frequencies in analyses of the data from Pulsar Timing Arrays (PTAs). While individual monochromatic plane waves are often a good approximation, a background composed of astrophysical sources cannot be monochromatic since an infinite plane wave carries no signal. We consider how relaxing this assumption allows us to extract potential information about modified dispersion relations and other fundamental physics questions, as both the group and phase velocity of waves become relevant. After developing the formalism we carry out simple Gaussian wavepacket examples and then consider more realistic waveforms, such as that from binary inspirals. When the frequency evolves only slowly across the PTA temporal baseline, the monochromatic assumption at an effective mean frequency remains a good approximation and we provide scaling relations that characterize its accuracy.

Hu, Wayne↗

Image reconstruction techniques applied to nuclear mass models

A new procedure is presented that combines well-known nuclear models with image reconstruction techniques. A color-coded image is built by taking the differences between measured masses and the predictions given by the different theoretical models. This image is viewed as part of a larger array in the (N,Z) plane, where unknown nuclear masses are hidden, covered by a 'mask'.' We apply a suitably adapted deconvolution algorithm, used in astronomical observations, to 'open the window' and see the rest of the pattern. We show that it is possible to improve significantly mass predictions in regions not too far from measured nuclear masses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A co-crystal of nonahydrated disodium(II) with mixed anions from m-chlorobenzoic acid and furosemide

In the title compound, [Na 2 (H 2 O) 9 ](C 7 H 4 ClO 2 )(C 12 H 10 ClN 2 O 5 S) {systematic name: catena-poly[[[triaquasodium(I)]-di-μ-aqua-[triaquasodium(I)]-μ-aqua] 3-chlorobenzoate 4-chloro-2-[(furan-2-ylmethyl)amino]-5-sulfamoylbenzoate]}, both the original m-chlorobenzoic acid and furosemide exist with deprotonated carboxylates, and the sodium cations and water molecules exist in chains with stoichiometry [Na 2 (OH 2 ) 9 ] 2+ that propagate in the [-110] direction. Each of the two independent Na + ions is coordinated by three monodentate water molecules, two double-water bridges, and one single-water bridge. There is considerable cross-linking between the [Na 2 (OH 2 ) 9 ] 2+ chains and to furosemide sulfonamide and carboxylate by intermolecular O—H...O hydrogen bonds. All hydrogen-bond donors participate in a complex two-dimensional array parallel to the ab plane. The furosemide NH group donates an intramolecular hydrogen bond to the carboxylate group, and the furosemide NH 2 group donates an intramolecular hydrogen bond to the Cl atom and an intermolecular one to the m-chlorobenzoate O atom. The plethora of hydrogen-bond donors on the cation/water chain leads to many large rings, up to graph set R 4 4 (24), involving two chains and two furosemide anions. The chlorobenzoate is involved in only one R 2 2 (8) ring, with two water molecules cis-coordinated to Na. The furan O atom is not hydrogen bonded.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of treatment log files in spot scanning proton therapy as part of patient-specific quality assurance

Purpose: The purpose of this work was to assess the monitor unit (MU) values and position accuracy of spot scanning proton beams as recorded by the daily treatment logs of the treatment control system, and furthermore establish the feasibility of using the delivered spot positions and MU values to calculate and evaluate delivered doses to patients. Methods: To validate the accuracy of the recorded spot positions, the authors generated and executed a test treatment plan containing nine spot positions, to which the authors delivered ten MU each. The spot positions were measured with radiographic films and Matrixx 2D ion-chambers array placed at the isocenter plane and compared for displacements from the planned and recorded positions. Treatment logs for 14 patients were then used to determine the spot MU values and position accuracy of the scanning proton beam delivery system. Univariate analysis was used to detect any systematic error or large variation between patients, treatment dates, proton energies, gantry angles, and planned spot positions. The recorded patient spot positions and MU values were then used to replace the spot positions and MU values in the plan, and the treatment planning system was used to calculate the delivered doses to patients. The results were compared with the treatment plan. Results: Within a treatment session, spot positions were reproducible within {+-}0.2 mm. The spot positions measured by film agreed with the planned positions within {+-}1 mm and with the recorded positions within {+-}0.5 mm. The maximum day-to-day variation for any given spot position was within {+-}1 mm. For all 14 patients, with {approx}1 500 000 spots recorded, the total MU accuracy was within 0.1% of the planned MU values, the mean (x, y) spot displacement from the planned value was (-0.03 mm, -0.01 mm), the maximum (x, y) displacement was (1.68 mm, 2.27 mm), and the (x, y) standard deviation was (0.26 mm, 0.42 mm). The maximum dose difference between calculated dose to the patient based on the plan and recorded data was within 2%. Conclusions: The authors have shown that the treatment log file in a spot scanning proton beam delivery system is precise enough to serve as a quality assurance tool to monitor variation in spot position and MU value, as well as the delivered dose uncertainty from the treatment delivery system. The analysis tool developed here could be useful for assessing spot position uncertainty and thus dose uncertainty for any patient receiving spot scanning proton beam therapy.

60 APPLIED LIFE SCIENCES↗

Systems and methods that generate height map models for efficient three dimensional reconstruction from depth information

Methods of generating a three dimensional representation of an object in a reference plane from a depth map including distances from a reference point to pixels in an image of the object taken from a reference point. Weights are assigned to respective voxels in a three dimensional grid along rays extending from the reference point through the pixels in the image based on the distances in the depth map from the reference point to the respective pixels, and a height map including an array of height values in the reference plane is formed based on the assigned weights. An n-layer height map may be constructed by generating a probabilistic occupancy grid for the voxels and forming an n-dimensional height map comprising an array of layer height values in the reference plane based on the probabilistic occupancy grid.

42 ENGINEERING↗

In-plane plasmon coupling in topological insulator Bi 2 Se 3 thin films

The surface states of the 3D topological insulator (TI), Bi 2 Se 3 , are known to host two-dimensional Dirac plasmon polaritons (DPPs) in the terahertz spectral range. In TI thin films, the DPPs excited on the top and bottom surfaces couple, leading to an acoustic mode and an optical plasmon mode. Vertical coupling in these materials is, therefore, reasonably well-understood, but in-plane coupling among localized TI DPPs has yet to be investigated. In this paper, we demonstrate in-plane DPP coupling in TI stripe arrays and show that they exhibit dipole–dipole type coupling. Here, the coupling becomes negligible when the lattice constant is greater than approximately 2.8 times the stripe width, which is comparable to results for in-plane coupling of localized plasmons excited on metallic nanoparticles or graphene plasmon polaritons. This understanding could be leveraged for the creation of TI-based metasurfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-430: Validation of IBEAM Evo Couch Top for Different Relative Electron Density (RED) Combination During Photon Beam Dose Calculation in Monaco− Treatment Planning System

Purpose: Validation of iBEAM™ evo couch-top for different relative electron density (RED) combination during photon beam dose calculation in Monaco− TPS. Methods: The iBEAM™ evo couch-top has two layers:outer carbon fiber (CF) and inner foam core (FC). To study the beam intensity attenuation of couch-top, measured doses were compared with doses calculated for different REDs. Measurements were performed in solid water phantom with PTW-0.125cc ion-chamber positioned at center of the phantom with 5.3cm thickness slabs placed above and below the chamber. Similarly, in TPS, iBEAM™ evo couch-top was simulated and doses were calculated for different RED combinations (0.2CF-0.2FC, 0.4CF-0.2FC, 0.6CF-0.2FC, 0.8CF-0.2FC, and 1.0CF-0.2FC) by using Monte Carlo dose calculation algorithm in Monaco TPS (V5.1). Doses were measured for every 10 degree gantry angle separation, 10×10cm{sup 2} field size and 6MV photons. Then, attenuation is defined as the ratio of output at posterior gantry angle to output of its opposed anterior gantry angle (e.g.225°/45°). output fluctuation with different gantry angle was within ±0.21%. To confirm above results, dose-planes were measured for five pelvic VMAT plans (360°arc) in PTW two-dimensional array and compared with different calculated dose-planes of above-mentioned couch REDs. Gamma pass rates<1.00) were analyzed for 3%/2mm criteria. Results: Measured and calculated attenuation was in good agreement for the RED combination of 0.2CF-0.2FC and difference was within ±0.515%. However, other density combination showed difference of ±0.9841%, ±1.667%, ±2.9241% and ±2.8832% for 0.4CF-0.2FC, 0.6CF-0.2FC, 0.8CF-0.2FC, and 1.0CF-0.2FC, respectively. Maximum couch-top attenuation was observed at 110°–120° and 240°–250° and decreases linearly as the gantry angle approaches 180°. Moreover, gamma pass rate confirmed the above results and showed maximum pass rate of 96.23% for 0.2CF-0.2FC, whereas others were 95.72%, 95.12%, 94.31% and 93.24%. Conclusion: RED value of 0.2CF-0.2FC was found to be suitable for accurate couch-top modeling for 6MV photon beam Monte Carlo calculations in Monaco TPS.

07 ISOTOPE AND RADIATION SOURCES↗

Physiologically gated microbeam radiation using a field emission x-ray source array

Purpose: Microbeam radiation therapy (MRT) uses narrow planes of high dose radiation beams to treat cancerous tumors. This experimental therapy method based on synchrotron radiation has been shown to spare normal tissue at up to 1000 Gy of peak entrance dose while still being effective in tumor eradication and extending the lifetime of tumor-bearing small animal models. Motion during treatment can lead to significant movement of microbeam positions resulting in broader beam width and lower peak to valley dose ratio (PVDR), which reduces the effectiveness of MRT. Recently, the authors have demonstrated the feasibility of generating microbeam radiation for small animal treatment using a carbon nanotube (CNT) x-ray source array. The purpose of this study is to incorporate physiological gating to the CNT microbeam irradiator to minimize motion-induced microbeam blurring. Methods: The CNT field emission x-ray source array with a narrow line focal track was operated at 160 kVp. The x-ray radiation was collimated to a single 280 μm wide microbeam at entrance. The microbeam beam pattern was recorded using EBT2 Gafchromic{sup ©} films. For the feasibility study, a strip of EBT2 film was attached to an oscillating mechanical phantom mimicking mouse chest respiratory motion. The servo arm was put against a pressure sensor to monitor the motion. The film was irradiated with three microbeams under gated and nongated conditions and the full width at half maximums and PVDRs were compared. An in vivo study was also performed with adult male athymic mice. The liver was chosen as the target organ for proof of concept due to its large motion during respiration compared to other organs. The mouse was immobilized in a specialized mouse bed and anesthetized using isoflurane. A pressure sensor was attached to a mouse's chest to monitor its respiration. The output signal triggered the electron extraction voltage of the field emission source such that x-ray was generated only during a portion of the mouse respiratory cycle when there was minimum motion. Parallel planes of microbeams with 12.4 Gy/plane dose and 900 μm pitch were delivered. The microbeam profiles with and without gating were analyzed using γ-H2Ax immunofluorescence staining. Results: The phantom study showed that the respiratory motion caused a 50% drop in PVDR from 11.5 when there is no motion to 5.4, whereas there was only a 5.5% decrease in PVDR for gated irradiation compared to the no motion case. In thein vivo study, the histology result showed gating increased PVDR by a factor of 2.4 compared to the nongated case, similar to the result from the phantom study. The full width at tenth maximum of the microbeam decreased by 40% in gating in vivo and close to 38% with phantom studies. Conclusions: The CNT field emission x-ray source array can be synchronized to physiological signals for gated delivery of x-ray radiation to minimize motion-induced beam blurring. Gated MRT reduces valley dose between lines during long-time radiation of a moving object. The technique allows for more precise MRT treatments and makes the CNT MRT device practical for extended treatment.

60 APPLIED LIFE SCIENCES↗

A 2D ion chamber array audit of wedged and asymmetric fields in an inhomogeneous lung phantom

Purpose: The Australian Clinical Dosimetry Service (ACDS) has implemented a new method of a nonreference condition Level II type dosimetric audit of radiotherapy services to increase measurement accuracy and patient safety within Australia. The aim of this work is to describe the methodology, tolerances, and outcomes from the new audit. Methods: The ACDS Level II audit measures the dose delivered in 2D planes using an ionization chamber based array positioned at multiple depths. Measurements are made in rectilinear homogeneous and inhomogeneous phantoms composed of slabs of solid water and lung. Computer generated computed tomography data sets of the rectilinear phantoms are supplied to the facility prior to audit for planning of a range of cases including reference fields, asymmetric fields, and wedged fields. The audit assesses 3D planning with 6 MV photons with a static (zero degree) gantry. Scoring is performed using local dose differences between the planned and measured dose within 80% of the field width. The overall audit result is determined by the maximum dose difference over all scoring points, cases, and planes. Pass (Optimal Level) is defined as maximum dose difference ≤3.3%, Pass (Action Level) is ≤5.0%, and Fail (Out of Tolerance) is >5.0%. Results: At close of 2013, the ACDS had performed 24 Level II audits. 63% of the audits passed, 33% failed, and the remaining audit was not assessable. Of the 15 audits that passed, 3 were at Pass (Action Level). The high fail rate is largely due to a systemic issue with modeling asymmetric 60° wedges which caused a delivered overdose of 5%–8%. Conclusions: The ACDS has implemented a nonreference condition Level II type audit, based on ion chamber 2D array measurements in an inhomogeneous slab phantom. The powerful diagnostic ability of this audit has allowed the ACDS to rigorously test the treatment planning systems implemented in Australian radiotherapy facilities. Recommendations from audits have led to facilities modifying clinical practice and changing planning protocols.

60 APPLIED LIFE SCIENCES↗

Light field X-ray optics

Devices, systems and methods for performing X-ray scans with a single line of sight using a lens array for capturing the light field of the X-rays are described. In one example aspect, an X-ray optical system includes a primary optics subsection positioned to receive incoming X-rays after traversal through an object and to redirect the received incoming X-rays onto an intermediate image plane. The system also includes a microlens array positioned at or close to the intermediate image plane to receive at least some of the received incoming X-rays after redirection by the primary optics subsection to diffract the X-rays that are incident thereupon.

Kozioziemski, Bernard J.↗

Large arrays of dual-polarized multichroic TES detectors for CMB measurements with the SPT-3G receiver

Now, detectors for cosmic microwave background (CMB) experiments are background limited, so a straightforward alternative to improve sensitivity is to increase the number of detectors. Large arrays of multichroic pixels constitute an economical approach to increasing the number of detectors within a given focal plane area. We present the fabrication of large arrays of dual-polarized multichroic transition-edge-sensor (TES) bolometers for the South Pole Telescope third-generation CMB receiver (SPT-3G). The complete SPT-3G receiver will have 2690 pixels, each with six detectors, allowing for individual measurement of three spectral bands (centered at 95 GHz, 150 GHz and 220 GHz) in two orthogonal polarizations. In total, the SPT-3G focal plane will have 16140 detectors. Each pixel is comprised of a broad-band sinuous antenna coupled to a niobium microstrip transmission line. In-line filters are used to define the different band-passes before the millimeter-wavelength signal is fed to the respective Ti/Au TES sensors. Detectors are read out using a 64x frequency domain multiplexing (fMux) scheme. The microfabrication of the SPT-3G detector arrays involves a total of 18 processes, including 13 lithography steps. Together with the fabrication process, the effect of processing on the Ti/Au TES's T-c is discussed. In addition, detectors fabricated with Ti/Au TES films with Tc between 400 mK 560 mK are presented and their thermal characteristics are evaluated. Optical characterization of the arrays is presented as well, indicating that the response of the detectors is in good agreement with the design values for all three spectral bands (95 GHz, 150 GHz, and 220 GHz). The measured optical efficiency of the detectors is between 0.3 and 0.8. Our results discussed here are extracted from a batch of research of development wafers used to develop the baseline process for the fabrication of the arrays of detectors to be deployed with the SPT-3G receiver. Results from these research and development wafers have been incorporated into the fabrication process to get the baseline fabrication process presented here. SPT-3G is scheduled to deploy to the South Pole Telescope in late 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Searches for dark matter subhaloes with wide-field Cherenkov telescope surveys

The presence of substructures in dark matter haloes is an unavoidable consequence of the cold dark matter paradigm. Indirect signals from these objects have been extensively searched for with cosmic rays and {gamma} rays. At first sight, Cherenkov telescopes seem not very well suited for such searches, due to their small fields of view and the random nature of the possible dark matter substructure positions in the sky. However, with long enough exposure and an adequate observation strategy, the very good sensitivity of this experimental technique allows us to constrain particle dark matter models. We confront here the sensitivity map of the HESS experiment built out of their Galactic scan survey to the state-of-the-art cosmological N-body simulation Via Lactea II. We obtain competitive constraints on the annihilation cross section, at the level of 10{sup -24}-10{sup -23} cm{sup 3} s{sup -1}. The results are extrapolated to the future Cherenkov Telescope Array, in the cases of a Galactic plane survey and of an even wider extragalactic survey. In the latter case, it is shown that the sensitivity of the Cherenkov Telescope Array will be sufficient to reach the most natural particle dark matter models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Loads Surrogates for Waked Turbines in an Array

Accurately and efficiently predicting wind turbine structural loading is a crucial step in wind farm design. Without considering structural loading, wind farm optimization could negatively impact turbine fatigue and ultimate loads, especially for waked and partially waked turbines, which could result in higher maintenance costs and reduced turbine lifetime. However, predicting turbine loads throughout an array is a costly step, as these quantities require time-accurate results across long time histories, which is often intractable for large array optimization. Therefore, surrogate models that link array spacing to load outputs are often used, but the surrogates are then unique to the inflow conditions and array configurations in the training library. This work develops surrogate models for many wind turbine load outputs based solely on rotor plane velocity measurements, with no required input about array configuration or freestream inflow parameters. Surrogate models were constructed for many turbine quantities of interest (QoI), considering mean, standard deviation, ultimate, and fatigue loads. In general, most QoI statistics were accurately captured, as measured by predicted vs. actual correlation coefficient, confirming the suitability of the approach. Temporal mean values of the QoI required only temporal mean measurements of the rotor plane inflow velocity. However, accurate prediction of temporal standard deviation, ultimate, and fatigue values of QoI also required temporal standard deviations of the rotor plane velocity field. Poor surrogate performance was observed when too many correlated inputs were used, such as multiple velocity components. If the fewest inflow parameters are used to construct the surrogates, the average correlation coefficient value for all output QoI statistics is 0.89. Surrogates for standard deviations and damage equivalent loads (DELs) of turbine QoIs generally had lower accuracy and tower-base and shaft load channels posed the most difficult to capture accurately. The results suggest that these surrogates could be easily paired with analytic wake models, which are frequently used for pre-construction wind farm array optimization, to account for turbine loading in addition to power production. By including the optimal inflow conditions, the surrogate accuracy can improve to an average correlation coefficient value for all output QoI statistics of 0.92. This work has established the ability to build accurate surrogates for mean, standard deviation, ultimate load, and DEL turbine QoI values based on the rotor plane inflow velocity, and identified which inflow conditions lead to greater surrogate accuracy.

17 WIND ENERGY↗

Surface Interaction and Quantum Kinetic Molecular Sieving for H2 and D2 Adsorption on a Mixed-Metal-Organic Framework Material

A rational strategy has been used to immobilize open metal sites in ultramicroporosity for stronger binding of multiple H{sub 2} molecules per unsaturated metal site for H{sub 2} storage applications. The synthesis and structure of a mixed zinc/copper metal/organic framework material Zn{sub 3}(BDC){sub 3}[Cu(Pyen)] {center_dot} (DMF){sub 5}(H{sub 2}O){sub 5} (H{sub 2}BDC = 1,4 benzenedicarboxylic acid and PyenH{sub 2} = 5-methyl-4-oxo-1,4-dihydro-pyridine-3-carbaldehyde) is reported. Desolvation provides a bimodal porous structure Zn{sub 3}(BDC){sub 3}[Cu(Pyen)] (M{prime}MOF 1) with narrow porosity (<0.56 nm) and an array of pores in the bc crystallographic plane where the adsorbate-adsorbent interactions are maximized by both the presence of open copper centers and overlap of the potential energy fields from pore walls. The H{sub 2} and D{sub 2} adsorption isotherms for M{prime}MOF 1 at 77.3 and 87.3 K were reversible with virtually no hysteresis. Methods for determination of the isosteric enthalpies of H{sub 2} and D{sub 2} adsorption were compared. A virial model gave the best agreement (average deviation <1 standard deviation) with the isotherm data. This was used in conjunction with the van't Hoff isochore giving isosteric enthalpies at zero surface coverage of 12.29 {+-} 0.53 and 12.44{+-} 0.50 kJ mol{sup -1} for H{sub 2} and D{sub 2} adsorption, respectively. This is the highest value so far observed for hydrogen adsorption on a porous material. The enthalpy of adsorption, decreases with increasing amount adsorbed to 9.5 kJ mol{sup -1} at {approx} 1.9 mmol g{sup -1} (2 H{sub 2} or D{sub 2} molecules per Cu corresponding to adsorption on both sides of planar Cu open centers) and is virtually unchanged in the range 1.9-3.6 mmol g{sup -1}. Virial analysis of isotherms at 87.3 K is also consistent with two H{sub 2} or D{sub 2} molecules being bound to each open Cu center. The adsorption kinetics follow a double exponential model, corresponding to diffusion along two types of pores, a slow component with high activation energy (13.35 {+-} 0.59 kJ mol{sup -1}) for the narrow pores and a faster component with low activation energy (8.56 0.41 kJ mol{sup -1}). The D{sub 2} adsorption kinetic constants for both components were significantly faster than the corresponding H{sub 2} kinetics for specific pressure increments and had slightly lower activation energies than the corresponding values for H{sub 2} adsorption. The kD{sub 2}/kH{sub 2} ratio for the slow component was 1.62 {+-} 0.07, while the fast component was 1.38 {+-} 0.04 at 77.3 K, and the corresponding ratios were smaller at 87.3 K. These observations of kinetic isotope quantum molecular sieving in porous materials are due to the larger zero-point energy for the lighter H{sub 2}, resulting in slower adsorption kinetics compared with the heavier D{sub 2}. The results show that a combination of open metal centers and confinement in ultramicroporosity leads to a high enthalpy for H{sub 2} adsorption over a wide range of surface coverage and quantum effects influence diffusion of H{sub 2} and D{sub 2} in pores in M{prime}MOF 1.

08 HYDROGEN↗

Method for measuring the focal spot size of an x-ray tube using a coded aperture mask and a digital detector

Purpose: The goal of this study is to evaluate a new method based on a coded aperture mask combined with a digital x-ray imaging detector for measurements of the focal spot sizes of diagnostic x-ray tubes. Common techniques for focal spot size measurements employ a pinhole camera, a slit camera, or a star resolution pattern. The coded aperture mask is a radiation collimator consisting of a large number of apertures disposed on a predetermined grid in an array, through which the radiation source is imaged onto a digital x-ray detector. The method of the coded mask camera allows one to obtain a one-shot accurate and direct measurement of the two dimensions of the focal spot (like that for a pinhole camera) but at a low tube loading (like that for a slit camera). A large number of small apertures in the coded mask operate as a ''multipinhole'' with greater efficiency than a single pinhole, but keeping the resolution of a single pinhole. Methods: X-ray images result from the multiplexed output on the detector image plane of such a multiple aperture array, and the image of the source is digitally reconstructed with a deconvolution algorithm. Images of the focal spot of a laboratory x-ray tube (W anode: 35-80 kVp; focal spot size of 0.04 mm) were acquired at different geometrical magnifications with two different types of digital detector (a photon counting hybrid silicon pixel detector with 0.055 mm pitch and a flat panel CMOS digital detector with 0.05 mm pitch) using a high resolution coded mask (type no-two-holes-touching modified uniformly redundant array) with 480 0.07 mm apertures, designed for imaging at energies below 35 keV. Measurements with a slit camera were performed for comparison. A test with a pinhole camera and with the coded mask on a computed radiography mammography unit with 0.3 mm focal spot was also carried out. Results: The full width at half maximum focal spot sizes were obtained from the line profiles of the decoded images, showing a focal spot of 0.120 mmx0.105 mm at 35 kVp and M=6.1, with a detector entrance exposure as low as 1.82 mR (0.125 mA s tube load). The slit camera indicated a focal spot of 0.112 mmx0.104 mm at 35 kVp and M=3.15, with an exposure at the detector of 72 mR. Focal spot measurements with the coded mask could be performed up to 80 kVp. Tolerance to angular misalignment with the reference beam up to 7 deg. in in-plane rotations and 1 deg. deg in out-of-plane rotations was observed. The axial distance of the focal spot from the coded mask could also be determined. It is possible to determine the beam intensity via measurement of the intensity of the decoded image of the focal spot and via a calibration procedure. Conclusions: Coded aperture masks coupled to a digital area detector produce precise determinations of the focal spot of an x-ray tube with reduced tube loading and measurement time, coupled to a large tolerance in the alignment of the mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tailored Silicon Nanopost Arrays for Resonant Nanophotonic Ion Production

Nanostructures that have dimensions commensurate with the wavelength of the electromagnetic radiation exhibit near-field effects1,2 and, as optical antennas, can couple laser radiation to the local environment3. Laser-induced silicon microcolumn arrays behave as nanophotonic ion sources that can be modulated by rotating the plane of light polarization4,5. Here we demonstrate that nanopost arrays (NAPA) can be tailored to exhibit resonant ion production. Ion yields from posts with subwavelength diameter show sharp resonances at high aspect ratios. The resonant enhancement in ion intensities can be modulated by adjusting the periodicity. In addition to strong molecular ion formation, the presence of high energy fragmentation channels is observed. Ion yields from NAPA exhibit dramatic differences for p- and s-polarized laser beams, indicating that energy coupling is similar to antenna arrays. These nanophotonic ion sources can control the degree of ion fragmentation and could eventually be integrated with micromachined mass spectrometers and microfluidic devices.

74 ATOMIC AND MOLECULAR PHYSICS↗