Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Position sensor for linear synchronous motors employing halbach arrays

A position sensor suitable for use in linear synchronous motor (LSM) drive systems employing Halbach arrays to create their magnetic fields is described. The system has several advantages over previously employed ones, especially in its simplicity and its freedom from being affected by weather conditions, accumulated dirt, or electrical interference from the LSM system itself.

33 ADVANCED PROPULSION SYSTEMS↗

Field-structured chemiresistors : tunable sensors for chemical-switch arrays.

We have developed a significantly improved composite material for applications to chemiresistors, which are resistance-based sensors for volatile organic compounds. This material is a polymer composite containing Au-coated magnetic particles organized into electrically conducting pathways by magnetic fields. This improved material overcomes the various problems inherent to conventional carbon-black chemiresistors, while achieving an unprecedented magnitude of response. When exposed to chemical vapors, the polymer swells only slightly, yet this is amplified into large, reversible resistance changes - as much as 9 decades at a swelling of only 1.5 %. These conductor-insulator transitions occur over such a narrow range of analyte vapor concentration that these devices can be described as chemical switches. We demonstrate that the sensitivity and response range of these sensors can be tailored over a wide range by controlling the stress within the composite, including through the application of a magnetic field. Such tailorable sensors can be used to create sensor arrays that can accurately determine analyte concentration over a broad concentration range, or can be used to create logic circuits that signal a particular chemical environment. It is shown through combined mass-sorption and conductance measurements, that the response curve of any individual sensor is a function of polymer swelling alone. This has the important implication that individual sensor calibration requires testing with only a single analyte. In addition, we demonstrate a method for analyte discrimination based on sensor response kinetics, which is independent of analyte concentration. This method allows for discrimination even between chemically similar analytes. Lastly, additional variables associated with the composite and their effects on sensor response are explored.

36 MATERIALS SCIENCE↗

Methods for fabrication of positional and compositionally controlled nanostructures on substrate

Fabrication methods disclosed herein provide for a nanoscale structure or a pattern comprising a plurality of nanostructures of specific predetermined position, shape and composition, including nanostructure arrays having large area at high throughput necessary for industrial production. The resultant nanostracture patterns are useful for nanostructure arrays, specifically sensor and catalytic arrays.

36 MATERIALS SCIENCE↗

Flow Enhanced Electrochemical Sensor Performance in Complex Salt Systems

To advance MSR MC&A practices, Argonne National Laboratory developed and optimized robust flow enhanced electrochemical sensors (FEES) and multielectrode array voltammetry sensors (MAVS) which provide accurate near-real time measurements of actinides in molten salts. Flow-enhanced electrochemical sensors are installed directly into MSR flow conduits for inline salt chemistry measurement, while MAVS are deployed in quiescent salt conditions enabling online species concentration determination in stationary salt vessels. This report summarizes efforts to improve electrochemical sensor technological readiness through (1) sensor testing in complex, high concentration molten salt systems to demonstrate low uncertainty actinide measurements in MSR-representative solutions and (2) demonstrations of sensor performance in challenging real-world conditions in collaboration with partner MSR institutions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Preliminary Assessment of Microwave Readout Multiplexing Factor

Ultra-high resolution microcalorimeter gamma spectroscopy is a new non-destructive assay technology for measurement of plutonium isotopic composition, with the potential to reduce total measurement uncertainty to a level competitive with destructive analysis methods [1-4]. Achieving this level of performance in practical applications requires not only the energy resolution now routinely achieved with transition-edge sensor microcalorimeter arrays (an order of magnitude better than for germanium detectors) but also high throughput. Microcalorimeter gamma spectrometers have not yet achieved detection efficiency and count rate capability that is comparable to germanium detectors, largely because of limits from existing readout technology. Microcalorimeter detectors must be operated at low temperature to achieve their exceptional energy resolution. Although the typical 100 mK operating temperatures can be achieved with reliable, cryogen-free systems, the cryogenic complexity and heat load from individual readout channels for large sensor arrays is prohibitive. Multiplexing is required for practical systems. The most mature multiplexing technology at present is time-division multiplexing (TDM) [3, 5-6]. In TDM, the sensor outputs are switched by applying bias current to one SQUID amplifier at a time. Transition-edge sensor (TES) microcalorimeter arrays as large as 256 pixels have been developed for X-ray and gamma-ray spectroscopy using TDM technology. Due to bandwidth limits and noise scaling, TDM is limited to a maximum multiplexing factor of approximately 32-40 sensors on one readout line [8]. Increasing the size of microcalorimeter arrays above the kilopixel scale, required to match the throughput of germanium detectors, requires the development of a new readout technology with a much higher multiplexing factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Miniaturized Magnetoelastic Sensor System

This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-cost scalable quartz crystal microbalance array for environmental sensing

Proliferation of environmental sensors for internet of things (IoT) applications has increased the need for low-cost platforms capable of accommodating multiple sensors. Quartz crystal microbalance (QCM) crystals coated with nanometer-thin sensor films are suitable for use in high-resolution (~1 ng) selective gas sensor applications. We demonstrate a scalable array for measuring frequency response of six QCM sensors controlled by low-cost Arduino microcontrollers and a USB multiplexer. Gas pulses and data acquisition were controlled by a LabVIEW user interface. We test the sensor array by measuring the frequency shift of crystals coated with different compositions of polymer composites based on poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) while films are exposed to water vapor and oxygen inside a controlled environmental chamber. Our sensor array exhibits comparable performance to that of a commercial QCM system, while enabling high-throughput 6 QCM testing for under $1,000. We use deep neural network structures to process sensor response and demonstrate that the QCM array is suitable for gas sensing, environmental monitoring, and electronic-nose applications.

Anazagasty, Cristain↗

Measuring Cities with Software-Defined Sensors

The Chicago Array of Things (AoT) project, funded by the US National Science Foundation, created an experimental, urban-scale measurement capability to support diverse scientific studies. Initially conceived as a traditional sensor network, collaborations with many science communities guided the project to design a system that is remotely programmable to implement Artificial Intelligence (AI) within the devices-at the “edge” of the network-as a means for measuring urban factors that heretofore had only been possible with human observers, such as human behavior including social interaction. The concept of “software-defined sensors” emerged from these design discussions, opening new possibilities, such as stronger privacy protections and autonomous, adaptive measurements triggered by events or conditions. We provide examples of current and planned social and behavioral science investigations uniquely enabled by software-defined sensors as part of the SAGE project, an expanded follow-on effort that includes AoT.

97 MATHEMATICS AND COMPUTING↗

An Experimental Investigation of Distributed Acoustic Sensing (DAS) on Lake Ice

A vibration-sensitive, Distributed Acoustic Sensor (DAS) array, using fiber-optic cables, was deployed in a triangularly shaped geometry on the frozen surface of Lake Mendota in Madison, Wisconsin, USA. The purpose of the array and testing program was to analyze the DAS response and to utilize the high spatial density of the distributed array for system response characterization in a well-constrained, small, surface array. A geophone array was also deployed to provide a reference system. The design of the array allowed us to assess the response of DAS with respect to distance from the seismic sources, the degradation of the response with length of the cable, the directivity of the fiber response with respect of the direction of the particle motion, and the quality of the signal with respect to cable type. The DAS array was examined for different cable constructions and orientations relative to the source propagation direction. Tight-buffered and loose-tube fiber-optic cable constructions were used, with both having good signal responses when well-coupled to the ice. In general, the tight-buffered cable was better suited for DAS applications. Directional sensitivity of the DAS was also inspected for several directions of wave propagation and particle motion. The results showed that the strongest DAS signals were recorded when the direction of the fiber was oriented parallel to the direction of particle motion. Lastly, the DAS and geophone data sets were examined together to qualitatively determine, in conjunction with established DAS best practices, how the high spatial density offered by DAS could improve results over traditional point sensor arrays in certain situations.

15 GEOTHERMAL ENERGY↗

Facile microwave synthesis of zirconium metal-organic framework thin films on gold and silicon and application to sensor functionalization

Zirconium-based metal-organic frameworks, including UiO-66 and related frameworks, have become the focus of considerable research in the area of chemical warfare agent (CWA) decontamination. However, little work has been reported exploring these metal-organic frameworks (MOFs) for CWA sensing applications. For many sensing approaches, the growth of high-quality thin films of the active material is required, and thin film growth methods must be compatible with complex device architectures. Several approaches to synthesize thin films of UiO-66 have been described but many of these existing methods are complex or time consuming. In this work, we describe the development of a simple and rapid microwave assisted synthesis of oriented UiO-66 thin films on unmodified silicon (Si) and gold (Au) substrates. Thin films of UiO-66 and UiO-66-NH 2 can be grown in as little as 2 min on gold substrates and 30 min on Si substrates. The film morphology and orientation are characterized and the effects of reaction time and temperature on thin film growth on Au are investigated. Both reaction time and temperature impact the overgrowth of protruding discrete crystallites in the thin film layer but, surprisingly, no strong correlation is observed between film thickness and reaction time or temperature. We also briefly describe the synthesis of Zr/Ce solid solution thin films of UiO-66 on Au and report the first synthesis of a solid solution thin film MOF. Finally, we demonstrate the utility of the microwave method for the facile functionalization of two sensor architectures, plasmonic nanohole arrays and microresonators, with UiO-66 thin films.

36 MATERIALS SCIENCE↗

Retinal-inspired method and system for improved detection

The present disclosure provides a method and device for filtering sensor data. Signals from an array of sensor pixels are received and checked for changes in pixel values. Motion is detected based on the changes in pixel values, and motion output signals are transmitted to a processing station. If the sum of correlated changes in pixel values across a predetermined field of view exceeds a predetermined value, indicating sensor jitter, the motion output signals are suppressed. If a sum of motion values within a defined subsection of the field of view exceeds a predetermined threshold, indicating the presence of a large object of no interest, the motion output signals are suppressed for that subsection.

42 ENGINEERING↗

Ionization Gas Sensor using Aligned Multiwalled Carbon Nanotubes Array

The challenge with current conventional gas sensors which are operating using semiconducting oxides is their size. After the introduction of nanotechnology and in order to reduce the dimension and consequently the power consumption and cost, new materials such as carbon nanotubes (CNTs) are being introduced. From previous works and characterization results, it was proven that the CNTs based gas sensor has better sensitivity, selectivity and faster response time in compared with semiconducting oxides based gas sensors. As in this work, a fabrication and successful testing of an ionization-based gas sensor using aligned Multiwalled CNTs (MWCNTs) as sensing element is discussed, in which MWCNTs array and Al film are used as anode and cathode plates respectively with electrode separation ranging from 80 {mu}m to 140 {mu}m. Aligned MWCNTs array was incorporated into a sensor configuration in the gas chamber for testing of gases such as argon, air, and mixed gas of 2%H{sub 2} in air. Obtained results show that among the three gases, argon has the lowest breakdown voltage whilst air has the highest value and the breakdown voltage was found to decrease as the electrode spacing was reduced from 140 {mu}m to 80 {mu}m for all three gases.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

X-ray Characterization of a Multichannel Smart-Pixel Array Detector

The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

CMOS ASIC↗

Structure-property relationships in NO x sensor materials composed of arrays of vanadium oxide nanoclusters

Here, the mixed-valent vanadium oxide based three-dimensional framework structure species [Cd 3 (H 2 O) 12 V 16 IV V 2 V O 36 (OH) 6 (AO 4 )]∙24H 2 O, (A=V,S) (Cd 3 (VO) o ) represents a rare example of an interesting sensor material which exhibits NO x {NO+NO 2 } semiconducting gas sensor properties under ambient conditions. The electrical resistance of the sensor material Cd 3 (VO) o decreases in air. Combined characterization studies revealed that the building block, {V 18 O 42 (AO 4 )} cluster, of 3-D framework undergoes oxidation and remains intact for at least 2 months. The decrease in resistance is attributable to the reactivity of molecular oxygen towards vanadium which results in an increase in the oxidation state as well as the coordination number of vanadium center and decrease in band gap of Cd 3 (VO) o . Based on these results we propose that the changes in semiconducting properties of Cd 3 (VO) o under ambient conditions are due to the greater overlap between the O 2p and V 3d orbitals occurring during the oxidation.

36 MATERIALS SCIENCE↗

The POLARBEAR-2 and Simons Array Focal Plane Fabrication Status

We present on the status of POLARBEAR-2 A (PB2-A) focal plane fabrication. The PB2-A is the first of three telescopes in the Simons Array, which is an array of three cosmic microwave background polarization-sensitive telescopes located at the POLARBEAR site in Northern Chile. As the successor to the PB experiment, each telescope and receiver combination is named as PB2-A, PB2-B, and PB2-C. PB2-A and -B will have nearly identical receivers operating at 90 and 150 GHz while PB2-C will house a receiver operating at 220 and 270 GHz. Each receiver contains a focal plane consisting of seven close-hex packed lenslet-coupled sinuous antenna transition edge sensor bolometer arrays. Each array contains 271 dichroic optical pixels, each of which has four TES bolometers for a total of 7588 detectors per receiver. We have produced a set of two types of candidate arrays for PB2-A. The first we call Version 11 (V11) uses a silicon oxide (SiOx) for the transmission lines and crossover process for orthogonal polarizations. The second we call Version 13 (V13) uses silicon nitride (SiNx) for the transmission lines and cross-under process for orthogonal polarizations. We have produced enough of each type of array to fully populate the focal plane of the PB2-A receiver. The average wirebond yield for V11 and V13 arrays is 93.2% and 95.6%, respectively. The V11 arrays had a superconducting transition temperature (T-c) of 452 +/- 15 mK, a normal resistance (R-n) of 1.25 +/- 0.20 Omega, and saturation powers of 5.2 +/- 1.0 pW and 13 +/- 1.2 pW for the 90 and 150 GHz bands, respectively. The V13 arrays had a superconducting transition temperature (T-c) of 456 +/- 6 mK, a normal resistance (R-n) of 1.1 +/- 0.2 Omega, and saturation powers of 10.8 +/- 1.8 pW and 22.9 +/- 2.6 pW for the 90 and 150 GHz bands, respectively. Production and characterization of arrays for PB2-B are ongoing and are expected to be completed by the summer of 2018. We have fabricated the first three candidate arrays for PB2-C but do not have any characterization results to present at this time.

CMB↗

Optimizing infrasound observations for sample return capsule re-entry: Insights from OSIRIS-REx and Hayabusa2

The atmospheric entry of meteoroids presents a rare and unpredictable phenomenon, posing challenges for systematic observation and detailed characterization. Such events are nonetheless critical for advancing understanding of acoustic wave propagation, atmospheric structure, and entry dynamics. In contrast, sample return capsules (SRCs) from space missions follow well constrained re-entry trajectories, enabling planned observations of shock wave generation and propagation under controlled conditions. This study compares two SRC atmospheric entries, Hayabusa2 in 2020 and OSIRIS-REx in 2023, to assess how different infrasound array configurations influence shock wave detection and trajectory validation. Hayabusa2’s re-entry was monitored using a distributed network of 28 portable infrasound sensors across seven arrays in Woomera, Australia, permitting three-dimensional reconstruction of the trajectory and analysis of wave characteristics. For OSIRIS-REx, a compact four-sensor array deployed near Eureka Airport provided trajectory confirmation through arrival-time differences and back-azimuth estimates. Spectral and waveform analyses revealed differences in signal properties associated with variations in entry angle and velocity. The results illustrate both the strengths and the limitations of the deployed array configurations. The dense and distributed arrays during Hayabusa2’s re-entry enabled detailed trajectory reconstruction, whereas the compact array at Eureka primarily provided confirmation of signal coherence and back-azimuth consistency. These case studies highlight that even relatively small arrays, if located close to the predicted ground track, can still capture useful information on arrival direction and timing. Such insights provide practical guidance for planning future observational campaigns of SRC returns and other controlled atmospheric entries, and may also inform approaches to opportunistic observations of meteoroid events and other atmospheric acoustic phenomena.

celestial mechanics: orbit determination↗

Response of the Land-Atmosphere System Over North-Central Oklahoma During the 2017 Eclipse

On 21 August 2017, a solar eclipse occurred over the continental United States resulting in a rapid reduction and subsequent increase of solar radiation over a large region of the country. The eclipse’s effect on the land-atmosphere system is documented in unprecedented detail using a unique array of sensors deployed at three sites in north-central Oklahoma. The observations showed that turbulent fluxes of heat and momentum at the surface responded quickly to the change in solar radiation. The decrease in the sensible heat flux resulted in a decrease in the air temperature below 200 m, and a large decrease in turbulent motions throughout the boundary layer. Furthermore, the turbulent mixing in the boundary layer lagged behind the change in the surface fluxes, and this lag depended on the height above the surface. The turbulent motions increased and the convective boundary layer was reestablished as the sensible heat flux recovered.

Turner, D. D.↗

Evolving Deep Networks Using HPC

While a large number of deep learning networks have been studiedand published that produce outstanding results on natural imagedatasets, these datasets only make up a fraction of those to whichdeep learning can be applied. These datasets include text data, audiodata, and arrays of sensors that have very different characteristicsthan natural images. As these “best” networks for natural imageshave been largely discovered through experimentation and cannotbe proven optimal on some theoretical basis, there is no reasonto believe that they are the optimal network for these drasticallydifferent datasets. Hyperparameter search is thus often a very im-portant process when applying deep learning to a new problem. Inthis work we present an evolutionary approach to searching thepossible space of network hyperparameters and construction thatcan scale to 18, 000 nodes. This approach is applied to datasets ofvarying types and characteristics where we demonstrate the abilityto rapidly find best hyperparameters in order to enable practitionersto quickly iterate between idea and result.

Young, Steven↗