Strain prediction and benchmark with measurement in the Spallation Neutron Source mercury target without gas injection
Not Available
Evidence of a halo formation mechanism in the Spallation Neutron Source linac
Not Available
Benchmarking shielding simulations for an accelerator-driven spallation neutron source
Not Available
Ewald: an extended wide-angle Laue diffractometer for the second target station of the Spallation Neutron Source
Visualizing hydrogen atoms in biological materials is one of the biggest remaining challenges in biophysical analysis. While X-ray techniques have unrivaled capacity for high-throughput structure determination, neutron diffraction is uniquely sensitive to hydrogen atom positions in crystals of biological materials and can provide a more complete picture of the atomic and electronic structures of biological macromolecules. This information can be essential in providing predictive understanding and engineering control of key biological processes, for example, in catalysis, ligand binding and light harvesting, and to guide bioengineering of enzymes and drug design. One very common and large capability gap for all neutron atomic resolution single-crystal diffractometers is the weak flux of available neutron beams, which results in limited signal-to-noise ratios giving a requirement for sample volumes of at least 0.1 mm 3 . The ability to operate on crystals an order of magnitude smaller (0.01 mm 3 ) will open up new and more complex systems to studies with neutrons which will help in our understanding of enzyme mechanisms and enable us to improve drugs against multi resistant bacteria. With this is mind, an extended wide-angle Laue diffractometer, `Ewald', has been designed, which can collect data using crystal volumes below 0.01 mm 3 .
Updates on the Progress of the Alternate Topology Modulator (AT-HVCM) to support the Proton Power Upgrade (PPU) at the Spallation Neutron Source
The AT-HVCM, achieved by series-stacking the dual-function resonant filter capacitors following each rectification stage, is the baseline design for the PPU project at the SNS [1]. The project requires three AT-HVCM modulators to power 28 additional 700kW klystrons and associated high beta cavities to accelerate 38mA of beam current to 1.3GeV. Each modulator produces an 82 kV, 120A output pulse of 1.35ms duration at a 60Hz repetition rate. The AT design approach improves upon the existing HVCM topology, reducing stresses on the H bridge IGBTs using zero voltage (ZVS) and current switching (ZCS) techniques and on the resonant filter capacitors by limiting voltage reversal. This paper reviews the prototype development progress, currently focused on evaluating system reliability, and discusses some design techniques to achieve the modulator performance requirements.
Incident Beamline Simulation for Ei= 510 meV on the ARCS spectrometer at the Spallation Neutron Source.
An mcpl of simulated neutron events captured at a location 20 cm upstream of the sample position.
Analysis of the Preliminary Bunker Shielding Design with a Mix of Populated and Unpopulated Neutron Beamlines at the Spallation Neutron Source Second Target Station
Explore the source record for details and available documents.
Development of Nuclear Data Measurements Capabilities at the Spallation Neutron Source
Explore the source record for details and available documents.
Machine learning at the Spallation Neutron Source accelerator and target
We describe the ongoing efforts to apply Machine Learning techniques to improve the performance of our accelerator and target. Specially, we are looking to minimize halo beam losses in the absence of a proper physics model, automatically detect and log anomalies in the target support systems such as cooling, and detect and prevent errant beam pulses in the linac. We also describe the infrastructure we use to acquire and stream data to the GPU cluster for training, our code development cycle, and edge computing for model inference. To minimize halo beam losses, we use a Reinforcement Learning technique tested on a virtual accelerator. The target anomaly detection is trained on archived data using incomplete physics models and is made part of the existing target reporting system. The errant beam prevention analyzes beam current and beam phase waveforms as well as accelerator configuration data to predict errant pulses. We also develop continual learning to adapt to changes in the accelerator.
Moderator Demonstration Facility Design and Optimization
The Spallation Neutron Source (SNS) facility at Oak Ridge National Laboratory (ORNL) is implementing a Moderator Demonstration Facility (MDF) to demonstrate the performance characteristics of advanced moderators central to the Second Target Station (STS) for SNS. The MDF will use the "spare" front-end installation within the SNS accelerator support complex – an ion source, radio-frequency quadrupole (RFQ) accelerator, and medium-energy beam transport (MEBT) chopper - to provide a 2.5 MeV proton beam of peak current 50 mA and maximum pulse length of less than 10 s at a repetition rate of no more than 60 Hz to a suitable neutron-producing target to demonstrate those aspects of moderator performance necessary to meet the goals of the STS design e ort. The accelerator beam parameters are not open to variation beyond that described above - they are fixed by the nature of the spare front-end installation (the Integrated Test Stand Facility; ITSF). Accordingly, there are some neutronic challenges in developing prototypic moderator illumination from a very non-prototypic primary neutron source; the spallation source we are attempting to mimic has an extended neutron source volume approximately 40 cm long (in the direction of the proton beam), approximately 10 cm wide (horizontally transverse to the proton beam) and approximately 5 cm high (vertically transverse to the proton beam), and an isotropic evaporation energy spectrum with mean energy above 1 MeV. In contrast, the primary neutron source available from the 7Li(p,n) reaction (the most prolific at 2.5 MeV proton energy by more than an order of magnitude) is strongly anisotropic, with an energy spectrum that is both strongly dependent on emission angle and kinematically limited to less than 700 keV, and the interaction zone between the incident protons and any target material (neutron-producing or not) is intrinsically limited to a few tens of microns. The MDF will be unique and innovative amongst the world’s moderator test facilities in that it will be intended to be very prototypic in terms of "moderator illumination" - the spatial variation of the neutron flux entering the moderator itself - as well as capable of testing so-called high-brightness moderators in a wing configuration.
Experimental capabilities with neutron beams at LANSCE. Short pulse spallation neutron sources [Slides]
Los Alamos National Laboratory (LANL) is the location of the Los Alamos Neutron Science Center (LANSCE). The presentation outlines the various components and capabilities at LANSCE.
First Experiments: New Science Opportunities at the Spallation Neutron Source Second Target Station (abridged)
This brochure is an abridged version of a more comprehensive companion report. DOE proposes to build a Second Target Station (STS) at SNS to produce beams of cold neutrons with world-leading peak brightness at a repetition rate of 15 Hz, providing broad energy/wavelength ranges that can be used simultaneously. Construction of the STS will provide transformative capabilities that allow thousands of users from national laboratories, universities, and industry to address grand scientific challenges [Hemminger 2015], advance energy research, and accelerate industrial innovations through the combination of cold (long-wavelength) neutrons of unprecedented peak brightness and short neutron pulses with broad ranges of usable wavelengths or energy. The STS Project, now in progress at ORNL, will design, construct, install, and commission the facilities and equipment needed to create a world-leading source of cold neutrons of unprecedented peak brightness at SNS. Key aspects of the STS design, including preliminary descriptions of an illustrative suite of eight instruments, are presented in the section “The STS at SNS.” The capabilities offered by the STS instruments (22 when fully built out) will complement those of the FTS and HFIR, providing the United States with unparalleled resources for neutron scattering at the world’s leading high–peak brightness cold neutron source.
Actinides and Neutron Scattering at the Spallation Neutron Source and High Flux Isotope Reactor
The importance of actinides for science, technology, and medicine is widely recognized and does not require a lengthy introduction. However, the fundamental understanding of actinides and their chemical and physical properties lags behind the knowledge of most other elements in the periodic table. Most actinides (89 ≤ Z ≤ 103) are man-made and were produced in particle accelerators or nuclear reactors in the second half of the 20th century. Although trends in bonding and electronic structure are well characterized and documented across the periodic table, fundamental questions remain regarding the chemistry and physics of the actinides. This lack of knowledge is largely because most isotopes of actinides are intensely radioactive, which greatly increases the difficultly in handling them.
Spallation Neutron Source Proton Power Upgrade (PPU) Project: Lessons Learned for CD-4
The SNS PPU project goals were to design, build, install and test the equipment necessary to double the accelerator power from 1.4 MW to 2.8 MW and to deliver a 2.0 MW qualified target. PPU also included the provision of a stub-out in the SNS accumulator-ring-to-target tunnel to facilitate a rapid connection to a new proton beamline for the Second Target Station (STS) project. The power capability was doubled by increasing the proton beam energy by 33% and the peak beam current by 50%, relative to pre-PPU accelerator performance. The project also included modifications to some buildings and services. The PPU project accomplished the energy upgrade by fabricating and installing new superconducting radiofrequency (RF) cryomodules, with supporting RF equipment, in the existing linac tunnel and klystron gallery, respectively. The High Voltage Converter Modulators (HVCM) and klystrons for some of the existing installed RF equipment were upgraded to handle the higher beam current. The increased beam power of 2 MW on the First Target Station (FTS) was enabled by the addition of a new high-volume gas injection system for pressure pulse and cavitation mitigation in the mercury target and a redesigned mercury target vessel.
Novel Large Area High Resolution Neutron Detector for the Spallation Neutron Source
Neutron scattering is a powerful technique that is critically important for materials science and structural biology applications. The knowledge gained from past developments has resulted in far-reaching advances in engineering, pharmaceutical and biotechnology industries, to name a few. New facilities for neutron generation at much higher flux, such as the SNS at Oak Ridge, TN, will greatly enhance the capabilities of neutron scattering, with benefits that extend to many fields and include, for example, development of improved drug therapies and materials that are stronger, longer-lasting, and more impact-resistant. In order to fully realize this enhanced potential, however, higher neutron rates must be met with improved detection capabilities, particularly higher count rate capability in large size detectors, while maintaining practicality. We have developed a neutron detector with the technical and economic advantages to accomplish this goal. This new detector has a large sensitive area, offers 3D spatial resolution, high sensitivity and high count rate capability, and it is economical and practical to produce. The proposed detector technology is based on B-10 thin film conversion of neutrons in long straw-like gas detectors. A stack of many such detectors, each 1 meter in length, and 4 mm in diameter, has a stopping power that exceeds that of He-3 gas, contained at practical pressures within an area detector. With simple electronic readout methods, straw detector arrays can provide spatial resolution of 4 mm FWHM or better, and since an array detector of such form consists of several thousand individual elements per square meter, count rates in a 1 m^2 detector can reach 2?10^7 cps. Moreover, each individual event can be timetagged with a time resolution of less than 0.1 ?sec, allowing accurate identification of neutron energy by time of flight. Considering basic elemental cost, this novel neutron imaging detector can be commercially produced economically, probably at a small fraction of the cost of He-3 detectors. In addition to neutron scattering science, the fully developed base technology can be used as a rugged, low-cost neutron detector in area monitoring and surveying. Radiation monitors are used in a number of other settings for occupational and environmental radiation safety. Such a detector can also be used in environmental monitoring and remote nuclear power plant monitoring. For example, the Department of Energy could use it to characterize nuclear waste dumps, coordinate clean-up efforts, and assess the radioactive contaminants in the air and water. Radiation monitors can be used to monitor the age and component breakdown of nuclear warheads and to distinguish between weapons and reactor grade plutonium. The UN's International Atomic Energy Agency (IAEA) uses radiation monitors for treaty verification, remote monitoring, and enforcing the non-proliferation of nuclear weapons. As part of treaty verification, monitors can be used to certify the contents of containers during inspections. They could be used for portal monitoring to secure border checkpoints, sea ports, air cargo centers, public parks, sporting venues, and key government buildings. Currently, only 2% of all sea cargo shipped is inspected for radiation sources. In addition, merely the presence of radiation is detected and nothing is known about the radioactive source until further testing. The utilization of radiation monitors with neutron sensitivity and capability of operation in hostile port environments would increase the capacity and effectiveness of the radioactive scanning processes.
SPALLATION NEUTRON SOURCE SUPERCONDUCTING LINAC KLYSTRON TO CAVITY MISMATCH EFFECTS AND COMPENSATION*
Abstract Observations of several of the 81 klystron output waveforms into their respective superconducting cavities do not correspond with their rectangular klystron inputs in open loop mode. This can't be completely explained by a drooping high voltage power supply especially when the waveform is parabolic. Some possible causes and effects of these anomalies are presented.