Search NASA⌕ Search

SEARCH · Search NASA

Results for “system noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

HgCdTe photodiodes for CO2 laser systems

A recently developed long-wave infrared detector, the photovoltaic HgCdTe, has many advantages which may solve some of the system problems that have impeded the development of carbon dioxide systems. The detectors are available for operation in the temperature range from 77 K to 146 K. Noise problems inherent in a number of conventional detection techniques can be overcome by a suitably implemented optical heterodyne method. Aspects of heterodyne detector development are discussed along with questions concerning the HgCdTe photodiodes which are available.

Koehler, T.↗

Thermotile Refrigerators

Thermoelectric tiles provide cooling exactly where needed. Thermotile is modular thermoelectric cooling unit that incorporates sensor and electronic circuitry in addition to thermoelectric device. Refrigerator/freezer is lined with thermotiles clipped into supporting lattices. Small fans used to circulate air in refrigerator and freezer compartments. Elimination of conventional mechanical refrigeration machinery reduces number of moving parts and completely eliminates noise and vibration. Data capabilities of thermotile refrigeration system used for diagnosis of defects or monitoring local temperatures. Thermotiles produced by automated manufacturing techniques. Custom shapes molded as needed.

Park, Brian V.↗

Origin of mechanical and dielectric losses from two-level systems in amorphous silicon

Amorphous silicon contains tunneling two-level systems, which are the dominant energy loss mechanisms for amorphous solids at low temperatures. These two-level systems affect both mechanical and electromagnetic oscillators and are believed to produce thermal and electromagnetic noise and energy loss. However, it is unclear whether the two-level systems that dominate mechanical and dielectric losses are the same; the former relies on the coupling between phonons and two-level systems, with an elastic field coupling constant γ while the latter depends on a two-level systems dipole moment p0, which couples to the electromagnetic field. Mechanical and dielectric loss measurements as well as structural characterization were performed on amorphous silicon thin films grown by electron beam deposition with a range of growth parameters. Samples grown at 425 °C show a large reduction of mechanical loss (34 times) and a far smaller reduction of dielectric loss (2.3 times) compared to those grown at room temperature. Additionally, mechanical loss shows lower loss for thicker films, while dielectric loss shows lower loss for thinner films. Overall, analysis of these results indicate that mechanical loss correlates with atomic density, while dielectric loss correlates with dangling-bond density, suggesting a different origin for these two energy dissipation processes in amorphous silicon.

36 MATERIALS SCIENCE↗

Aeroacoustics of Three-Stream Jets

Results from acoustic measurements of noise radiated from a heated, three-stream, co-annular exhaust system operated at subsonic conditions are presented. The experiments were conducted for a range of core, bypass, and tertiary stream temperatures and pressures. The nozzle system had a fan-to-core area ratio of 2.92 and a tertiary-to-core area ratio of 0.96. The impact of introducing a third stream on the radiated noise for third-stream velocities below that of the bypass stream was to reduce high frequency noise levels at broadside and peak jet-noise angles. Mid-frequency noise radiation at aft observation angles was impacted by the conditions of the third stream. The core velocity had the greatest impact on peak noise levels and the bypass-to-core mass flow ratio had a slight impact on levels in the peak jet-noise direction. The third-stream jet conditions had no impact on peak noise levels. Introduction of a third jet stream in the presence of a simulated forward-flight stream limits the impact of the third stream on radiated noise. For equivalent ideal thrust conditions, two-stream and three-stream jets can produce similar acoustic spectra although high-frequency noise levels tend to be lower for the three-stream jet.

Henderson, Brenda↗

Aeroacoustics of Three-Stream Jets

Results from acoustic measurements of noise radiated from a heated, three-stream, co-annular exhaust system operated at subsonic conditions are presented. The experiments were conducted for a range of core, bypass, and tertiary stream temperatures and pressures. The nozzle system had a fan-to-core area ratio of 2.92 and a tertiary-to-core area ratio of 0.96. The impact of introducing a third stream on the radiated noise for third-stream velocities below that of the bypass stream was to reduce high frequency noise levels at broadside and peak jet-noise angles. Mid-frequency noise radiation at aft observation angles was impacted by the conditions of the third stream. The core velocity had the greatest impact on peak noise levels and the bypass-to-core mass flow ratio had a slight impact on levels in the peak jet-noise direction. The third-stream jet conditions had no impact on peak noise levels. Introduction of a third jet stream in the presence of a simulated forward-flight stream limits the impact of the third stream on radiated noise. For equivalent ideal thrust conditions, two-stream and three-stream jets can produce similar acoustic spectra although high-frequency noise levels tend to be lower for the three-stream jet.

Henderson, Brenda S.↗

Fermilab PIP-II Master Oscillator and Precision Reference Line Design and Construction

The phase averaging reference line system pro- vides the RF phase reference, LO and clock sig- nals to the LLRF and other accelerator sub- systems. The PIP-II linac has RF systems at three frequencies – 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase- noise oscillator is used as the master oscil- lator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each fre- quency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, Ahmed [Fermilab]↗

Aircraft measurement of radio frequency noise at 121.5 MHz, 243 MHz and 406 MHz

An airborne survey measurement of terrestrial radio-frequency noise over U.S. metropolitan areas was carried out at 121.5, 243 and 406 MHz with horizontal-polarization monopole antennas. Flights were at 25,000 feet altitude. Radio-noise measurements, expressed in equivalent antenna-noise temperature, indicate a steady-background noise temperature of 572,000 K, at 121.5 MHz, during daylight over New York City. This data is helpful in compiling radio-noise temperature maps; in turn useful for designing satellite-aided, emergency-distress search and rescue communication systems.

Taylor, R. E.↗

Aircraft measurement of radio frequency noise at 121.5 MHz, 243MHz and 406MHz

An airborne survey measurement of terrestrial radio-frequency noise over U.S. metropolitan areas has been made at 121.5, 243 and 406 MHz with horizontal-polarization monopole antennas. Flights were at 25,000 feet altitude during the period from December 30, 1976 to January 8, 1977. Radio-noise measurements, expressed in equivalent antenna-noise temperature, indicate a steady-background noise temperature of 572,000 K, at 121.5 MHz, during daylight over New York City. This data is helpful in compiling radio-noise temperature maps; in turn useful for designing satellite-aided, emergency-distress search and rescue communication systems.

Taylor, R. E.↗

Calibration of a satellite infrared radiometer

The calibration procedure is described for a two-channel imaging radiometer on board the Heat Capacity Mapping Mission, a single sensor satellite in a near polar orbit. The Heat Capacity Mapping Radiometer measures radiation temperature and reflectivity with an instantaneous FOV of 600 m and a noise equivalent temperature of 0.4 K at 280 K in the thermal IR channel. Unexplained changes in the system during satellite launch were treated through comparison with surface/atmosphere data to force agreement. This necessitated an offset from the prelaunch calibration by 5.5 K. Later comparisons showed no difference. Possible explanations are presented.

Barnes, W. L.↗

Recent Langley Aerothermodynamic Laboratory Testing (2019-2022)

In support of flight programs, multiple wind tunnel entries were conducted on reentry vehicle configurations to investigate blunt body aeroheating environments. Blunt body block thermal protection system (TPS) roughness, the Low-Earth Orbit Flight Test of an Inflatable Decelerator aeroshell scalloping, and a woven TPS all were tested to determine the effects of those parameters on increased surface heating to the vehicle. Commercial Crew Program studies also utilized the speed and ease of testing in the LAL to analyze parametric databases of low-earth reentry configurations, like the Boeing CST-100, and vehicles designed to travel to the moon or Mars, such as the SpaceX Starship. LAL wind tunnel investigations also supported several DoD and AFRL flight projects, such as HIFiRE 6 and BOLT. External customers leveraged the LAL testing capability to advance their research programs, including UPSTAR, RocketLab, and Lawrence Livermore National Laboratory. Academia groups benefitted from the inexpensive cost to test in the tunnels for many university collaborations, such as studies conducted in partnership with the University of Maryland on a flat plate, using a pressure rake and investigating fluid structure interactions. Multiple studies in collaboration with Purdue considered boundary layer transition on various cone configurations. Another study was conducted using a cone with shaped roughness elements borrowed from the Arnold Engineering Development Complex. Internal testing included studies using a phosphor thermography system that can measure higher temperatures than the current LAL phosphor capability and a characterization study of the noise in the wind tunnel flow. The breadth of testing across research and commercial paradigms, both internal and external to NASA, different configurations, a variety of test techniques and aerodynamic and aerothermal environments will be discussed in this overview presentation of the recent work conducted in the LAL.

wind tunnel test↗

Master Oscillator and Phase Reference Line Design for the PIP-II Linac

The phase averaging reference line system provides the RF phase reference, LO and clock signals to the LLRF and other accelerator sub-systems. The PIP-II linac has RF systems at three frequencies - 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase-noise oscillator is used as the master oscillator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each frequency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

Syed, A. [Fermilab]↗

Diagnosing Noise Features Of Internally Mixed, External Plug Exhaust Systems

In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.

Noise prediction, supersonic, jet noise↗

Diagnosing Noise Features Of Internally Mixed, External Plug Exhaust Systems

In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.

Noise prediction↗

MAGIS-100 environmental characterization and noise analysis

We investigate and analyze site specific systematics for the MAGIS-100 atomic interferometry experiment at Fermi National Accelerator Laboratory. As atom interferometers move out of the laboratory environment passive and active mitigation for noise sources must be implemented. To inform the research and development of the experiment design, we measure ambient temperature, humidity, and vibrations of the installation site. We find that temperature fluctuations will necessitate enclosures for critical subsystems and a temperature controlled laser room for the laser system. We also measure and analyze the vibration spectrum above and below ground for the installation site. The seismic vibration effect of gravity gradient noise is also modeled using input from a low-noise seismometer at multiple locations and a mitigation scheme is studied using a stochastic simulation and characterized by a suppression factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dual high-energy radiography platform with 15 μ m resolution at the National Ignition Facility

To study matter at extreme densities and pressures, we need mega laser facilities such as the National Ignition Facility as well as creative methods to make observations during timescales of a billionth of a second. To facilitate this, we developed a platform and diagnostic to characterize a new point-projection radiography configuration using two micro-wires irradiated by a short pulse laser system that provides a large field of view with up to 3.6 ns separation between images. In this work, we used tungsten-carbide solid spheres as reference objects and inferred characteristics of the back-lighter source using a forward-fitting algorithm. The resolution of the system is inferred to be 15 μm (using 12.5 μm diameter wires). The bremsstrahlung temperature of the source is 70–300 keV, depending on laser energy and coupling efficiency. By adding the images recorded on multiple stacked image plates, the signal-to-noise of the system is nearly doubled. The imaging characterization technique described here can be adapted to most point-projection platforms where the resolution, spectral contrast, and signal-to-noise are important.

47 OTHER INSTRUMENTATION↗

NASA's high-temperature engine materials program for civil aeronautics

The Advanced High-Temperature Engine Materials Technology Program is described in terms of its research initiatives and its goal of developing propulsion systems for civil aeronautics with low levels of noise, pollution, and fuel consumption. The program emphasizes the analysis and implementation of structural materials such as polymer-matrix composites in fans, casings, and engine-control systems. Also investigated in the program are intermetallic- and metal-matrix composites for uses in compressors and turbine disks as well as ceramic-matrix composites for extremely high-temperature applications such as turbine vanes.

Gray, Hugh R.↗

A conceptual 34-meter antenna feed configuration for joint DSN/SETI use from 1 to 10 GHz

The very satisfactory performance of a conceptual 34-m DSS-12 type HA-Dec antenna feed sysem over the frequency range of 1 to 10 GHz is demonstrated. A seven-feedhorn baseline design is developed which will allow Search for Extra-Terrestrial Intelligence (SETI) investigations using each horn over a 1.4:1 frequency range. A gain/system noise temperature (G/T) figure of merit is calculated for the frequency range of each horn; it is found that system performance down to 20 deg elevation is possible with a G/T degradation of less than 3 dB at every frequency. The design presented here will allow shared but independent antenna use by the Deep Space Network (DSN) and SETI with a minimum of operational impacts to DSN functions and no intrusions into the DSN microwave equipment configuration.

Slobin, S. D.↗

NASA Tech Briefs, February 2011

Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.

Source record↗