Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Towards resolving protein structures at the atomic scale using atom probe tomography

In the field of Structural Biology, Atom Probe Tomography (APT) is in the nascent stages of development wherein coarse-grained visuals of proteins have been captured. The characterization of organic samples or biomolecules through the technique is currently limited to the detection of a few dominant signatures. The problem of indecipherable characterization can inherently be traced back to multiple forms of technique-specific responses to organic samples and consequent triggers leading to organic-sample and sample-medium interactions. While it is possible for captured manifestations of protein reconstructions to seemingly appear intact from a basic visual purview, the parameter-protein associative responses throughout the structure as a direct consequence of the inherent workings of the technique (until harmonized with organic sample complexity and behavior) and field evaporation-based factors make non-aberrative atomic associations infeasible. The work focused on identifying and theorizing the (above stated and other) fundamental mechanisms that stronghold the study of intricate atomic to higher order associations in proteins through APT. Attempts at structure elucidation of the cryogenic sample under study, through indirect associations (and methods) based on other imaging techniques, further revealed the distinct and highly distortive nature at the atomic scale deterring structural tunability and thus characterization of APT based cryogenic samples under analysis. As a direct counter to the atomic scale characterization problem, by taking the experiment-specific uncertainties, and probable APT-centric organic sample-based variabilities into account, a basic result is extracted and presented. Through mass-spectrometric and computational analysis, specific individual amino acids (Sulfur-containing protein-bound amino acids) in proteins and aspects of protein structure (probable backbone fragments, partial sequence - partial backbone portions) have been identified and characterized. Under analysis considerations, a few of the simplest known and easily inferable segments that favor structural deteriorations in the reconstructions are stated. Additionally, to overcome technique-specific deterrents to the characterization of biomolecules in cryogenic sample medium, the development of a protein-labeling strategy tailored to APT is suggested.

59 BASIC BIOLOGICAL SCIENCES↗

Automated defect detection in spent nuclear fuel using combine Cerenkov and Gamma Emission Tomography data

Spent fuel monitoring and characterization has been a pillar of safeguards and nuclear facility monitoring for many years. The Digital Cerenkov Viewing Device (DCVD) has been used since the 1980s as a method of defect detection in spent fuel. In recent years, the accounting of large quantities of spent fuel before storage has renewed interest in this relatively quick and inexpensive method. This has an impact not only in safeguards, but also in for nuclear power facilities, as accounting can be a long and arduous process. Additionally, the DCVD demonstrates limited accuracy in more complex cases such as substitution of a fuel rod with steel, or a partial defect detection. A second method, Gamma Emission Tomography (GET) has been explored as an improved defect detection method, but is much more expensive and invasive than DCVD. This work identifies deficiencies in both methods, and proposes a combination of data gathered from each method to address these deficiencies for improved spent fuel characterization. Initial results are promising, showing 97% detection of a single missing fuel rod when the data types are combined, versus approximately 50% and 70%respectively for DCVD and GET data on their own. Finally, these classification results are obtained with algorithms derived from facial recognition and applied to this problem, yielding unique accuracy in near real-time while also maintaining the information barrier between output and measurement desired in safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Three-Dimensional Reconstruction and Analysis of All-Solid Li-Ion Battery Electrode Using Synchrotron Transmission X-ray Microscopy Tomography

A synchrotron transmission X-ray microscopy tomography system with a spatial resolution of 58.2 nm at the Advanced Photon Source was employed to obtain three-dimensional morphological data of all-solid Li-ion battery electrodes. The three-phase electrode was fabricated from a 47:47:6 (wt %) mixture of Li(Ni 1/3 Mn 1/3 Co 1/3 )O 2 as active material, Li 1.3 Ti 1.7 Al 0.3 (PO 4 ) 3 as Li-ion conductor, and Super-P carbon as electron conductor. Furthermore, the geometric analysis show that particle-based all-solid Li-ion battery has serious contact interface problem which significantly impact the Li-ion transport and intercalation reaction in the electrode, leading to low capacity, poor rate capability and cycle life.

25 ENERGY STORAGE↗

Physical cryptographic verification of nuclear warheads

Significance We provide a method for potentially solving one of the central problems in arms control: proving the authenticity of a nuclear warhead without revealing information about its construction. The proposal is the first, to our knowledge, to be proof-theoretically sound (i.e., unspoofable) and information-theoretically secure. The method uses a tomography technique which can resolve the spatial distribution of mass with isotopic specificity. The soundness and security emerge from an integral-geometric transform that is able to uniquely map 3D geometries from zero-dimensional point measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total Internal Reflection Tomography (TIRT) for Three-Dimensional Sub-Wavelength Imaging

We will present a novel new form of near-field microscopy known as total internal reflection tomography (TIRT), which allows for true three-dimensional sub-wavelength imaging. It is based on recent theoretical advances regarding the fundamental interaction of light with sub-wavelength structures, as well as stable algorithms for the near-field inverse problem. We will discuss its theoretical underpinnings, as well describe current efforts at the NASA Glenn Research Center to implement a TIRT system for biofluid research.

Fischer, David G.↗

DOLCE: A Model-Based Probabilistic Diffusion Framework for Limited-Angle CT Reconstruction

Limited-Angle Computed Tomography (LACT) is a non-destructive evaluation technique used in a variety of applications ranging from security to medicine. The limited angle coverage in LACT is often a dominant source of severe artifacts in the reconstructed images, making it a challenging inverse problem. We present DOLCE, a new deep model-based framework for LACT that uses a conditional diffusion model as an image prior. Diffusion models are a recent class of deep generative models that are relatively easy to train due to their implementation as image denoisers. DOLCE can form high-quality images from severely under-sampled data by integrating data-consistency updates with the sampling updates of a diffusion model, which is conditioned on the transformed limited-angle data. We show through extensive experimentation on several challenging real LACT datasets that, the same pre-trained DOLCE model achieves the SOTA performance on drastically different types of images. Additionally, we show that, unlike standard LACT reconstruction methods, DOLCE naturally enables the quantification of the reconstruction uncertainty by generating multiple samples consistent with the measured data.

Kim, Hyojin↗

A Bayesian Measurment Error Model for Misaligned Radiographic Data

An understanding of the inherent variability in micro-computed tomography (micro-CT) data is essential to tasks such as statistical process control and the validation of radiographic simulation tools. The data present unique challenges to variability analysis due to the relatively low resolution of radiographs, and also due to minor variations from run to run which can result in misalignment or magnification changes between repeated measurements of a sample. Positioning changes artificially inflate the variability of the data in ways that mask true physical phenomena. We present a novel Bayesian nonparametric regression model that incorporates both additive and multiplicative measurement error in addition to heteroscedasticity to address this problem. We also use this model to assess the effects of sample thickness and sample position on measurement variability for an aluminum specimen. Supplementary materials for this article are available online.

97 MATHEMATICS AND COMPUTING↗

Imaging properties and its improvements of scanning/imaging x-ray microscope

A scanning / imaging X-ray microscope (SIXM) system has been developed at SPring-8. The SIXM consists of a scanning X-ray microscope with a one-dimensional (1D) X-ray focusing device and an imaging (full-field) X-ray microscope with a 1D X-ray objective. The motivation of the SIXM system is to realize a quantitative and highly-sensitive multimodal 3D X-ray tomography by taking advantages of both the scanning X-ray microscope using multi-pixel detector and the imaging X-ray microscope. Data acquisition process of a 2D image is completely different between in the horizontal direction and in the vertical direction; a 1D signal is obtained with the linear-scanning while the other dimensional signal is obtained with the imaging optics. Such condition have caused a serious problem on the imaging properties that the imaging quality in the vertical direction has been much worse than that in the horizontal direction. In this paper, two approaches to solve this problem will be presented. One is introducing a Fourier transform method for phase retrieval from one phase derivative image, and the other to develop and employ a 1D diffuser to produce an asymmetrical coherent illumination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iatrogenic Subtotal Stenosis of the Right Subclavian Artery Treated With Percutaneous Transluminal Angioplasty

This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplasty (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ru supported on micro and mesoporous carbons as catalysts for biomass-derived molecules hydrogenation

Supported ruthenium based materials are active for the catalytic hydrogenation of biomass-derived molecules. However, such catalysts still have problems regarding deactivation coming from Ru leaching and particles aggregation. In this work we demonstrate that spatial restriction on metal nanoparticles limits aggregation and eliminates performance losses upon subsequent testing. We synthesized and compared Ru supported on activated (Ru/AC) or mesoporous carbon (Ru/MC). Electron tomography characterization showed preferential Ru location depending on the material porosity; Ru nanoparticles were located inside mesoporous carbon pores and showed narrower size distribution. In catalytic reactions, Ru/MC reached the complete conversion of levulinic acid with the 96% selectivity to γ-valerolactone while it converted 74% of glycerol compared to the 34% showed by Ru/AC. Furthermore, we find that the Ru/AC materials deactivated after 1 catalytic cycle, however the Ru/MC maintained constant activity for multiple catalytic cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2D and 3D characterization of pore defects in die cast AM60

The widespread application of die castings can be hampered due to the potential of large scale porosity to act as nucleation sites for fracture and fatigue. It is therefore important to develop robust approaches to the characterization of porosity providing parameters that can be linked to the material's mechanical properties. We have tackled this problem in a study of the AM60 die cast Mg alloy, using samples extracted from a prototype shock tower. A quantitative characterization of porosity has been undertaken, analyzing porosity in both 2D (using classical metallographic methods) and in 3D (using X-ray computed tomography (XCT)). Metallographic characterization results show that shrinkage pores and small gas pores can be distinguished based on their distinct geometrical features. Shrinkage pores are irregular with multiple arms, resulting in a form factor less than 0.4. In contrast, gas pores are generally more circular in shape yielding form factors larger than 0.6. XCT provides deeper insight into the shape of pores, although this understanding is limited by the resolution obtainable by laboratory based XCT. It also shows how 2D sectioning can produce artefacts as single complex pores are sectioned into multiple small pores. - Highlights: • Mg (e.g. AM60) die castings may contain large scale porosity that act as nucleation sites for fracture and fatigue • Quantitative characterization of porosity metallography (2D) and X-ray tomography (3D) is used • Shrinkage pores and small gas pores can be distinguished based on their distinct geometrical features. • Shrinkage pores are irregular giving a form factor < 0.4; gas pores are rounder with form factors > 0.6 • XCT enables pore visualization, although limited by the resolution obtainable by laboratory based XCT.

36 MATERIALS SCIENCE↗

Bayesian soft X-ray tomography using non-stationary Gaussian Processes

In this study, a Bayesian based non-stationary Gaussian Process (GP) method for the inference of soft X-ray emissivity distribution along with its associated uncertainties has been developed. For the investigation of equilibrium condition and fast magnetohydrodynamic behaviors in nuclear fusion plasmas, it is of importance to infer, especially in the plasma center, spatially resolved soft X-ray profiles from a limited number of noisy line integral measurements. For this ill-posed inversion problem, Bayesian probability theory can provide a posterior probability distribution over all possible solutions under given model assumptions. Specifically, the use of a non-stationary GP to model the emission allows the model to adapt to the varying length scales of the underlying diffusion process. In contrast to other conventional methods, the prior regularization is realized in a probability form which enhances the capability of uncertainty analysis, in consequence, scientists who concern the reliability of their results will benefit from it. Under the assumption of normally distributed noise, the posterior distribution evaluated at a discrete number of points becomes a multivariate normal distribution whose mean and covariance are analytically available, making inversions and calculation of uncertainty fast. Additionally, the hyper-parameters embedded in the model assumption can be optimized through a Bayesian Occam's Razor formalism and thereby automatically adjust the model complexity. This method is shown to produce convincing reconstructions and good agreements with independently calculated results from the Maximum Entropy and Equilibrium-Based Iterative Tomography Algorithm methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of today’s dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study

Purpose: To study the performance of different dual energy computed tomography (DECT) techniques, which are available today, and future multi energy CT (MECT) employing novel photon counting detectors in an image-based material decomposition task. Methods: The material decomposition performance of different energy-resolved CT acquisition techniques is assessed and compared in a simulation study of virtual non-contrast imaging and iodine quantification. The material-specific images are obtained via a statistically optimal image-based material decomposition. A projection-based maximum likelihood approach was used for comparison with the authors’ image-based method. The different dedicated dual energy CT techniques are simulated employing realistic noise models and x-ray spectra. The authors compare dual source DECT with fast kV switching DECT and the dual layer sandwich detector DECT approach. Subsequent scanning and a subtraction method are studied as well. Further, the authors benchmark future MECT with novel photon counting detectors in a dedicated DECT application against the performance of today’s DECT using a realistic model. Additionally, possible dual source concepts employing photon counting detectors are studied. Results: The DECT comparison study shows that dual source DECT has the best performance, followed by the fast kV switching technique and the sandwich detector approach. Comparing DECT with future MECT, the authors found noticeable material image quality improvements for an ideal photon counting detector; however, a realistic detector model with multiple energy bins predicts a performance on the level of dual source DECT at 100 kV/Sn 140 kV. Employing photon counting detectors in dual source concepts can improve the performance again above the level of a single realistic photon counting detector and also above the level of dual source DECT. Conclusions: Substantial differences in the performance of today’s DECT approaches were found for the application of virtual non-contrast and iodine imaging. Future MECT with realistic photon counting detectors currently can only perform comparably to dual source DECT at 100 kV/Sn 140 kV. Dual source concepts with photon counting detectors could be a solution to this problem, promising a better performance.

60 APPLIED LIFE SCIENCES↗

X-ray microtomography

In this tutorial, we describe X-ray microtomography as a technique to nondestructively characterize material microstructure in three dimensions at a micron level spatial resolution. While commercially available laboratory scale instrumentation is available, we focus our attention on synchrotron-based systems, where we can exploit a high flux, monochromatic X-ray beam to produce high fidelity three-dimensional images. A brief description of the physics and the mathematical analysis behind the technique is followed by example applications to specific materials characterization problems, with a particular focus on the utilization of three-dimensional image processing that can be used to extract a wide range of useful information.

36 MATERIALS SCIENCE↗

Probing material nonlinearity at various depths by time reversal mirrors

In this Letter, the time reversal mirror is used to focus elastic energy at a prescribed location and to analyze the amplitude dependence of the focus signal, thus providing the nonlinearity of the medium. By varying the frequency content of the focused waveforms, the technique can be used to probe the surface, by penetrating to a depth defined by the wavelength of the focused waves. The validity of this concept is shown in the presence of gradual and distributed damage in concrete by comparing actual results with a reference nonlinear measurement and X ray tomography images.

36 MATERIALS SCIENCE↗

Experimental study of A0 Lamb wave tomography

Corrosion damage in inaccessible regions presents a significant challenge to the petrochemical industry, and determining the remaining wall thickness is important to establish the remaining service life. Guided wave tomography is one solution and involves transmitting Lamb waves through the area of interest and using the received signals to reconstruct the remaining wall thickness. This avoids the need to access all points on the surface, making the technique well suited to inspection beneath supports. For this purpose a tomography system for pipe inspections is developed using low frequency A0 Lamb waves that are excited and detected with two arrays of electromagnetic acoustic transducers (EMATs). Two different defect depths are considered with different contrasts relative to the nominal wall thickness and in a first step, the repeatability of the measurements is demonstrated. Due to the limited view array configuration, the maximum depth of the reconstruction underestimates the true depth. In a second experimental study, the influence of a pipe clamp on the thickness reconstruction is considered, representing an inspection problem with restricted access. Preliminary results have shown that the maximum defect depth is further underestimated when compared to the thickness reconstructions without the clamp. However, it is possible to detect the defect underneath the clamp for all conducted experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Production of medical {sup 99m}Tc isotope via photonuclear reaction

{sup 99m}Tc with a 6 hour half-life is one of the most important medical isotopes used for the Single-Photon Emission Computed Tomography (SPECT) inspection in hospitals of US, Canada, Europe and Japan. {sup 99m}Tc isotopes are extracted by the milking method from parent {sup 99}Mo isotopes with a 66 hour half-life. The supply of {sup 99}Mo isotopes now encounters a serious crisis. Hospitals may not suitably receive {sup 99}Mo medical isotopes in near future, due to difficulties in production by research nuclear reactors. Many countries are now looking for alternative ways to generate {sup 99}Mo isotopes other than those with research reactors. We discuss a sustained availability of {sup 99m}Tc isotopes via the {sup nat}Mo(γ, n) photonuclear reaction, and discuss to solve technical problems for extracting pure {sup 99m}Tc isotopes from other output materials of photonuclear reactions.

07 ISOTOPE AND RADIATION SOURCES↗