Search NASA⌕ Search

SEARCH · Search NASA

Results for “total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Estimating Uncertainty in Long Term Total Ozone Records from Multiple Sources

Total ozone measurements derived from the TOMS and SBUV backscattered solar UV instrument series cover the period from late 1978 to the present. As the SBUV series of instruments comes to an end, we look to the 10 years of data from the AURA Ozone Monitoring Instrument (OMI) and two years of data from the Ozone Mapping Profiler Suite (OMPS) on board the Suomi National Polar-orbiting Partnership satellite to continue the record. When combining these records to construct a single long-term data set for analysis we must estimate the uncertainty in the record resulting from potential biases and drifts in the individual measurement records. In this study we present a Monte Carlo analysis used to estimate uncertainties in the Merged Ozone Dataset (MOD), constructed from the Version 8.6 SBUV2 series of instruments. We extend this analysis to incorporate OMI and OMPS total ozone data into the record and investigate the impact of multiple overlapping measurements on the estimated error. We also present an updated column ozone trend analysis and compare the size of statistical error (error from variability not explained by our linear regression model) to that from instrument uncertainty.

TOMS and SBUV↗

The 27-Day Rotational Variations in Total Solar Irradiance Observations: from SORCE-TIM, ACRIMSAT-ACRIM III, and SOHO-VIRGO

During the last decade, observations from SORCE (Solar Radiation and Climate Experiment)/TIM (Total Irradiance Monitor), ACRIMSAT (Active Cavity Radiometer Irradiance Monitor Satellite)/ACRIM III, and SOHO (Solar and Heliospheric Observatory)VIRGO (Variability of IRradiance and Gravity Oscillations Sun PhotoMeter) provided the Total Solar Irradiance (TSI) measurements with unprecedented accuracy and stability to determine the amount of solar irradiance reaching the top of the atmosphere and how solar irradiance varies in different time scales. These three independent measurements are analyzed using the EEMD (Ensemble Empirical Mode Decomposition) method to characterize the phase and amplitude of 27-day solar rotational variation in TSI. The mode decomposition clearly identifies a 27-day solar rotational signature in TSI measurements. The rotational variations of TSI from the three independent observations are generally consistent with each other, despite different mean TSI values. During the declining phase of solar cycle 23, the amplitude of TSI 27-day variations is as high as 0.8 watts per square meter (approximately 0.05 percent), while during the rising phase of solar cycle 24, the amplitude is up to 0.4 watts per square meter (approximately 0.04 percent). During the minimum phase (2008-2009), the amplitude of the rotational mode is only 0.1 watts per square meter. The correlation of this rotational mode between TIM and ACRIM III is approximately 0.92 and the slope of the local peak values is approximately 0.98. The correlation between TIM and VIRGO is approximately 0.96 and the slope of the local peak values isapproximately 0.98, very similar to the slope with ACRIM III.

ACRIM III↗

LTC1877 High Efficiency Regulator Total Ionizing Dose Test Report

This report presents total ionizing dose evaluation data for the Linear Technology Corporation LTC1877 high efficiency monolithic synchronous step-down regulator. Data sheet parameters were tracked as a function of ionizing dose up to a total of 20 krad(SiO2). Control devices were also used.

total ionizing dose (TID)↗

New Approach to Total Dose Specification for Spacecraft Electronics

Variability of the space radiation environment is investigated with regard to total dose specification for spacecraft electronics. It is shown to have a significant impact. A new approach is developed for total dose requirements that replaces the radiation design margin concept with failure probability during a mission.

Device Failure Probability↗

Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA Goddard Space Flight Center and NASA Electronic Parts and Packaging Program

Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices. Displacement Damage, Optoelectronics, Proton Damage, Single Event Effects, and Total Ionizing Dose.

Proton Damage↗

Total Dose Survivability of Hubble Electronic Components

A total dose analysis for exposure of electronic parts at the box level is presented for the Hubble Space Telescope. This was done using solid angle sectoring/3-dimensional ray trace and Monte Carlo radiation transport simulations. Results are discussed in terms of parts that are potential total dose concerns.

Monte Carlo radiation transport simulation↗

U309 N-Channel Silicon Junction Field Effect Transistor Total Ionizing Dose Characterization Report

The purpose of this testing was to characterize the InterFET Corporation U309 for total dose response. This test shall serve as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. The U309 is a discrete Junction Field Effect Transistor (JFET). High dose rate (HDR) irradiations were performed in this test so that the device susceptibility to Total Ionizing Dose (TID) could be determined.

Total Ionizing Dose (TID)↗

Development of the Miniature Total Organic Carbon Analyzer

Monitoring the Total Organic Carbon (TOC) in spacecraft potable water will be of major importance in long-duration human space exploration. In-flight analysis of potable water produced from a regenerative water processor provides immediate feedback on the quality of reclaimed water for crew health as well as water processing system health monitoring. This paper updates the progress in development of the next generation Total Organic Carbon Analyzer (TOCA) designed for the unique requirements of an exploration-class mission. The current objective is to design, build, certify, deliver, and operate a TOCA technology demonstration on the International Space Station (ISS). The next generation analyzer system technology was previously developed and selected among a feasibility study of other options. The new system provides primary advantages of reduced mass and volume through reduced system complexity and reduced need for consumables; therefore, the flight project is named MiniTOCA. The project has recently completed design of the tech demo instrument and assembled and tested a flight-like engineering development unit. The engineering unit has undergone performance testing and environmental testing which provides confidence for the project to move forward with flight unit production and certification activities. Test results are summarized in this paper. The flight unit is targeted for delivery to ISS in late 2025.

TOC↗

Development of the Miniature Total Organic Carbon Analyzer

Monitoring the Total Organic Carbon (TOC) in spacecraft potable water will be of major importance in long-duration human space exploration. In-flight analysis of potable water produced from a regenerative water processor provides immediate feedback on the quality of reclaimed water for crew health as well as water processing system health monitoring. This paper updates the progress in development of the next generation Total Organic Carbon Analyzer (TOCA) designed for the unique requirements of an exploration-class mission. The current objective is to design, build, certify, deliver, and operate a TOCA technology demonstration on the International Space Station (ISS). The next generation analyzer system technology was previously developed and selected among a feasibility study of other options. The new system provides primary advantages of reduced mass and volume through reduced system complexity and reduced need for consumables; therefore, the flight project is named MiniTOCA. The project has recently completed design of the tech demo instrument and assembled and tested a flight-like engineering development unit. The engineering unit has undergone performance testing and environmental testing which provides confidence for the project to move forward with flight unit production and certification activities. Test results are summarized in this paper. The flight unit is targeted for delivery to ISS in late 2025.

TOC↗

A method of treating the non-grey error in total emittance measurements

In techniques for the rapid determination of total emittance, the sample is generally exposed to surroundings that are at a different temperature than the sample's surface. When the infrared spectral reflectance of the surface is spectrally selective, these techniques introduce an error into the total emittance values. Surfaces of aluminum overcoated with oxides of various thicknesses fall into this class. Because they are often used as temperature control coatings on satellites, their emittances must be accurately known. The magnitude of the error was calculated for Alzak and silicon oxide-coated aluminum and was shown to be dependent on the thickness of the oxide coating. The results demonstrate that, because the magnitude of the error is thickness-dependent, it is generally impossible or impractical to eliminate it by calibrating the measuring device.

Heaney, J. B.↗

Divergence of the total cross section for three body rearrangement collisions with coulomb interactions

Three charged particles 1, 2, 3 collide according to the reaction 1+(2+3) yields (1+3)+2, where (2+3) and (1+3) are hydrogenlike bound states. It is shown when (1+3) is in a highly excited state n, due to the repulsive potential, the cross section in the first Born approximation behaves as 1/n which makes the total cross section to diverge like ln n. The total cross sections in the higher orders of the Born approximation are similarly divergent logarithmically.

Omidvar, K.↗

Measurement of total electron content with a geostationary satellite during the solar eclipse of March 7, 1970.

This note deals with the measurement of the total electron content of the ionosphere at the Goddard Space Flight Center, looking towards the geostationary satellite ATS 3 during the solar eclipse of Mar. 7, 1970. Obscuration at this site was nearly total. Faraday rotation was measured with a stationary circularly polarized antenna and a dual-channel phase-lock receiver tuned to 137.350 MHz. By comparing the electrical phase of the two opposite circularly polarized components, a continuous chart recording was made of Faraday rotation vs local time. A depletion of about 25% in electron content was observed from first contact to the time of minimum electron content. The time variations of the electron content during the eclipse are briefly examined in the light of current theories of ionospheric processes.

Rangaswamy, S.↗

Total emittance of lunar fines.

Description of the technique and discussion of the results of measurements of the total emittance of Apollo 11, 12, and 14 samples of lunar fines. The measurements were performed as a function of temperature upon samples of a density large enough to eliminate any significant density effect on the total emittance.

Birkebak, R. C.↗

Rocket measurements of conjugate photoelectrons during the total solar eclipse of 7 March 1970 over Wallops Island.

Results of measurements made with a retarding potential analyzer on a Nike-Tomahawk rocket during the totality of the solar eclipse, showing definite evidence for the existence of photoelectrons from the conjugate hemisphere. Photoelectrons are observed in the altitude range from 120 to 260 km. The observed flux in the energy range from 2 to 30 eV is relatively constant above about 200 km, but decreased below that altitude. The flux of 5-eV energy electrons above 200 km altitude is about 10 to the 7th power electrons/cm/sec/eV. Higher-energy electrons were also observed, and it is possible that the energy content of these observed fluxes of conjugate-point photoelectrons is sufficient to maintain the observed electron densities and temperatures during the total eclipse.

Maier, E. J.↗

Total-pressure measurement in pulsating flows

Pneumatic-type probe was used as comparison instrument with total pressure tubes to determine true average pressure and, thus, to determine if nonlinear averaging effects were significant. Since pneumatic probe is more complicated to use than a total-pressure tube, it is used only as a comparison instrument to determine extent of averaging effects.

Krause, L. N.↗

Determination of the total outgoing radiance of the earth-atmosphere system

Utilizing eighty atmospheric models, the equivalent black body temperatures for the 6-7, 10-11, 15-16 and the 20-24 micron spectral regions, corresponding to the Nimbus 3 medium resolution infrared radiometer were computed. The black body temperatures for the 5-30 micron channel and the total outgoing radiances for these atmospheres were also computed. It was found that the total radiation can be estimated from the 10-11 micron channel alone with a standard error of 2.2 watts/sq m sr.

Pasternak, M.↗

Inference of total ozone from photometric measurements of sky radiation.

Ground-based photometric measurements of spectral sky radiation have been made using a simple filter instrument. Sky radiation intensities measured in the solar vertical at 3200 and 3600 A are compared to infer total ozone. A model of a multiple scattering Rayleigh atmosphere serves as a primary reduction parameter. Spectral measurements of all-sky radiance distribution are used to study the effects of haze and clouds on the inference of total ozone. The brightness distribution of clear and overcast sky in ultraviolet is also described.

Ghazi, A.↗