Search NASA⌕ Search

SEARCH · Search NASA

Results for “vacuum drying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Ultra sound absorption measurements in rock samples at low temperatures

A new technique, comparable with the reverberation method in room acoustics, is described. It allows Q-measurements at rock samples of arbitrary shape in the frequency range of 50 to 600 kHz in vacuum (.1 mtorr) and at low temperatures (+20 to -180 C). The method was developed in particular to investigate rock samples under lunar conditions. Ultrasound absorption has been measured at volcanics, breccia, gabbros, feldspar and quartz of different grain size and texture yielding the following results: evacuation raises Q mainly through lowering the humidity in the rock. In a dry compact rock, the effect of evacuation is small. With decreasing temperature, Q generally increases. Between +20 and -30 C, Q does not change much. With further decrease of temperature in many cases distinct anomalies appear, where Q becomes frequency dependent.

Herminghaus, C.↗

Patterning Metal Grids for GaAs Solar Cells with Cracked Film Lithography: Quantifying the Cost/Performance Tradeoff

We introduce cracked film lithography (CFL) as a way to reduce the cost of III–V photovoltaics (PV). We spin-coat nanoparticle suspensions onto GaAs thin-film device stacks. The suspensions dry in seconds, forming crack networks that we use as templates through which to electroplate the solar cells’ front metal grids. For the first time, we show that heating the crack template allows it to flow and refill cracks, which decreases crack footprint and improves final grid transmittance. We demonstrate 24.7%-efficient single-junction GaAs solar cells using vacuum-free CFL grids. These devices are only 1.7% (absolute) less efficient than the baseline grids patterned by photolithography with the loss mostly resulting from the reduced transparency of the CFL pattern. Additional optimization could decrease this difference. Initial cost modeling suggests that CFL is more scalable than photolithography: In particular, CFL’s lower materials and equipment costs could greatly reduce the levelized cost of electricity of III–V PV at scale, a potential step toward terrestrial deployment.

14 SOLAR ENERGY↗

Management of the Three Mile Island, Unit 2, Accident Corium and Severely Damaged Fuel Debris

The Three Mile Island, Unit Two (TMI-2) pressurized water reactor core melted down in 1979 due to an untimely combination of maintenance problems that led to a loss of feedwater, followed by a series of operational misunderstandings and errors. The melted core recovery process required development of a wide array of tools. After approximately three years of water management and other cleanup actions, the first views of the core revealed a much higher degree of damage than previously expected. Approximately 62 metric tons of the core had melted, leaving only 42 of the 177 fuel assemblies standing with a majority of rods intact. The core to be recovered was composed of loose debris and a solidified mass of formerly molten fuel. Robotic tools that had been designed for the task were of limited effectiveness due to the range of material types and phases. Over a period of several years, the central melt was broken up, primarily by use of a core-boring drill originally designed to acquire samples through the depth of the debris field. The broken pieces were loaded into specially designed debris canisters by use of long-handled pick-and-place tools and suctioned into baffled knockout canisters using an airlift vacuum system. A remotely operable underwater plasma arc torch was developed for removal of the lower core support structure to be able to retrieve the fuel pieces and secondary melt that had accumulated on the bottom reactor vessel head. Canister design played a central role in defining the initial retrieval process and later affected transportation, interim wet and its current interim dry storage. Due to concerns about the potential for radiolysis of residual water in the debris and other canister material, the canisters were fitted with hydrogen recombiner catalyst units to prevent a buildup of flammable gas and potential pressurization. To confirm the effectiveness of the recombiners during shipping, eight dewatered canisters were kept sealed for up to 205 days with periodic sampling of the headspace gas. The highest hydrogen value (9 vol%) was observed in a canister held for 147 days while the longest stored canister resulted in a 5% hydrogen concentration. The oxygen concentration never exceeded 0.5 %, and the primary backfill was >80% argon, meaning there was no flammability risk. Radiolytic hydrogen was also observed in wet pool storage, where the vented canisters discharged a portion of the water backfill as a result of gas production. The 344 canisters (268 fuel debris, 62 filter, and 12 knockout type) were dewatered, loaded in groups of seven into a double barrier shipping cask, and transported to the U.S. Department of Energy site in Idaho for 10 years of pool storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Process for the preparation of calcium superoxide

Calcium superoxide is prepared in high yields by spreading a quantity of calcium peroxide diperoxyhydrate on the surface of a container, positioning said container in a vacuum chamber on a support structure through which a coolant fluid can be circulated, partially evacuating said vacuum chamber, allowing the temperature of the diperoxyhydrate to reach the range of about 0 to about 40 C; maintaining the temperature selected for a period of time sufficient to complete the disproproriation of the diperoxyhydrate to calcium superoxide, calcium hydroxide, oxygen, and water; constantly and systematically removing the water as it is formed by sweeping the reacting material with a current of dry inert gas and/or by condensation of said water on a cold surface; backfilling the chamber with a dry inert gas; and finally, recovering the calcium superoxide produced.

Ballou, E. V.↗

Sample Polishing Without Epoxy

In recent years, we have received requests for meteorite sample sections to be prepared without using epoxy impregnation or mounting. The reasoning for these requests ranges from potential contamination of analyses from epoxy chemical components to degradation of instrumental vacuum from epoxy outgassing (e.g., SEM, SIMS, EPMA, etc.). An alternative approach that we employ involves sawing off a 1-5 mm thick wafer of the sample. The wafer is ground using silica carbide lapping media wetted with 190 proof ethyl alcohol to make both sides flat and parallel. The sample is then polished on one or both sides using diamond paste or dry diamond powder on a rotating lap wheel until the desired finish is obtained. The sample is cleaned in between steps using 200 proof ethyl alcohol in an ultrasonic cleaner. Friable and altered samples need to have higher thickness in order for polishing to be attempted. Without epoxy to hold the sample together or a glass slide for backing, the sample needs additional material to provide the necessary support structure. The machining steps of this process need to be undertaken at a much slower speed than in traditional thin or thick section preparation.

Meteorite↗

Quasi-In-Situ Analysis of Electrode Top Atomic Layers via High-Sensitivity Low-Energy Ion Scattering and Potential-Controlled Sample Transfer

Electrocatalytic reactions involve interfacial interactions between the surfaces of electrodes and reactive species at an electrolyte interface. There are presently no universal or unambiguous methods to directly assay the active top atomic layer composition that influences the reactivity of these electrodes under relevant operating conditions. Low-energy ion scattering (LEIS) spectroscopy is a surface characterization technique that yields compositional analysis of the outermost atomic layer of a material, but it must be performed in ultrahigh vacuum (UHV). Application of LEIS measurements to electrochemical materials that are removed from ambient liquid-phase environments thus leaves an open question as to whether the surface that is transferred to UHV is truly the surface that manifested during the electrochemical reaction. Toward the goal of preserving the active surface state, we developed a sample transfer workflow for LEIS enabling air-free removal and drying of an electrode from an electrochemical cell while maintaining control of the potential using an auxiliary electrode. The potential-controlled emersion method was demonstrated to give distinct potential-dependent surface compositions for a Cu−Pd alloy relative to removal after uncontrolled return to open-circuit potential. A Cu-enriched surface was found at anodic potential and a Pd-enriched surface at cathodic potential, suggesting that the approach can be used to retain representative atomic configurations during transfer. Since adsorbates will often persist from the reaction environment, conventional sample pretreatment methods for removal, including atomic O and atomic H exposure, were also contrasted. Both methods were found to differ with results from incidental low-dose depth profiling by the LEIS primary ion source, which removes adventitious species and surface atoms during the course of repeated measurements. These depth profiles were found to be sensitive to sample history and thus qualitatively informative, despite the possible changes induced by ion damage. The results exhibit (i) the need for complete control over the polarization state of the sample at all times (no excursions to open circuit during transfer) and (ii) the utility of low-dose depth profiling to capture changes in the near-surface composition.

Alloys↗

Flight Validation of Atomic Oxygen Resistant Resistant Polymers

Because of its high reactivity, atomic oxygen causes surface erosion on polymeric materials. although the reaction efficiency depends on the chemical structure of the polymer. We have found an organotin compound, bis(triphenyltin) oxide (BTO), which has an unusually high solubility in solutions of a number of commercial high performance polymers. Films of these polymers containing BTO showed a substantial reduction in erosion by atomic oxygen when compared with films of the pure material. Analysis has shown that in the presence of atomic oxygen, erosion of the exposed surfaces of the BTO-containing films leaves a residual protective tin oxide coating . Since the additive is uniformly distributed throughout the polymeric material, any break or puncture in the protective coating is "healed" by the material below. Samples were exposed to the environment of the low earth orbit (LEO) on two Space Shuttle flights, STS-46, in June of 1992, and STS-51 in September of 1993. The analysis of these samples has been reported previously. For both flights, the samples were small (1.3 cm and 1.9 cm respectively) thus limiting the scope of analysis. In the research under this cooperative agreement, films of a polyetherimide, were exposed to the LEO environment on Space Shuttle flight STS-85 in August of 1997 as part of the Evaluation of Space Environment and Effects on Materials (ESEM) experiment. The polyetherimide chosen is available commercially as Ultem, registered to the General Electric Company. Films of pure Ultem, Ultem with 10% BTO by mass, and Ultem with 20% BTO by mass were exposed in the ram direction for 40 hours during STS-85. Ultem has a Tg of 215 deg C and is soluble in common chlorinated solvents. Granules of the polymer were dried at 120 deg C, but otherwise were used as received. Films were cast on a glass plate from a solution of the polymer in a 60/40 (w/w) mixture of chloroform and 1,1,2,2-tetrachloroethane. The plate was placed in a dust-free box for at least 24 hours to allow much of the solvent to evaporate, and then was moved to a vacuum oven and slowly heated from 20 to 220 deg C over a period of two weeks to completely remove all solvent. Each exposed sample was 7.6 cm long and 2.2 cm wide and about 0.025 mm thick. The structures of Ultem and bis(triphenyltin) oxide are shown.

Kiefer, Richard L.↗

High-resolution submillimeter-wave radiometry of supersonic flow

The recent development of a high-resolution submillimeter-wave heterodyne radiometer has made possible the first measurements of H2O molecule rotational line excitation temperatures and detailed profiles in supersonic flow. Absorption signals were measured across the flow for the 2/11/ from 2//02/ (752 GHz) para-H2O rotational transition against a hot background. These signals decrease downstream owing to the volume expansion of the gas away from the sonic nozle exit in the high-vacuum chamber. Radiative transfer calculations based on the large-velocity-gradient approximation and multilevel statistical equilibrium agree with these results and with the measured spectral line shapes. The data reveal nearly isentropic gas expansion and cooling. These studies have shown that submillimeter-wave heterodyne radiometry can be useful for remote sensing of supersonic flow with low mass flux, provided the signal transmission is through a dry or thin atmosphere.

Dionne, G. F.↗

Some unusual oscillating bearing applications in liquid propellant rocket engines

Liquid propellant rocket engines have some unique applications for highly loaded oscillating-motion bearings operating at cryogenic temperatures and vacuum environment conditions. Among these are (1) thrust attitude control gimbal bearings that permit pivoting of the entire rocket engine and (2) bearings in the linkages of ducting bellows joints that articulate when the engine gimbals. The main rocket engines for first, second, and third stages of the Saturn vehicle have thrust vector control gimbals which use PTFE liner bearing materials and ducting linkage bearings using solid film dry lubricants, both to reduce friction and provide required wear life. Data on the frictional and wear characteristics of these materials, while operating under varying temperature and atmospheric pressure conditions, are presented. A discussion of the bearing designs for flexible bellows joint linkages is also presented.

Daniels, C. M.↗

A Study of Some Factors Affecting Rolling-Contact Fatigue Life

A series of investigations using the fatigue spin rig to study the effect of several factors contributing to rolling contact fatigue life is summarized. Ball specimens of 1/2 and 9/16 inch diameter were tested at maximum theoretical Hertz compressive stresses in the range of 600,000 to 750,000 psi. Life was found to vary inversely with the tenth power of stress. In forging fiber studies, a greater concentration of failures and poorer life were observed where the greatest angle of intersection between the fiber flow lines and the surface occurred. This effect was independent of alloy composition. Higher lubricant viscosity was found to increase fatigue life, Lubricants having the same viscosity but of different base stock produced wide differences in life that correlated with the pressure viscosity coefficient of the lubricant. Higher temperature produced lower fatigue life. Dry powder lubricants produced poor fatigue life at 450 F; failure appearance indicated that the lubricant particles probably acted as minute stress raisers. In metallographic studies, nonmetallic inclusions were found to have a deleterious effect on fatigue life the inclusion size, location, composition, and condition of the matrix being contributing factors; failures were by shear cracking in the subsurface zone of maximum shear stress and eventual propagation into a shallow surface spall. Vacuum melting improved fatigue life, although a general correlation between cleanliness and fatigue life was not found. Life results for ten different bearing materials are presented.

Carter, Thomas L.↗

Handling and analysis of ices in cryostats and glove boxes in view of cometary samples

Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples.

Roessler, K.↗

Extraction technique for the determination of oxygen-18 in water using preevacuated glass vials

The need for a rapid, inexpensive technique for routine 18O/16O extraction from water has arisen recently through applications in the medical sciences and in hydrology. The traditional experimental technique for determining the oxygen isotope composition of water, the CO2-H2O equilibration method, is tedious, time consuming, and involves the use of custom-made glass apparatus. Furthermore, because of potential memory effects from one sample to the next, the glassware needs to be thoroughly cleaned between runs. A few attempts have been made to improve upon the method. Attempts to analyze water directly in the source of the mass spectrometer produced large memory effects and questionable results. Commercially available apparatus for automated extraction of 18O/16O from water is generally prohibitively expensive and often is designed to interface only with the manufacturer's own mass spectrometer. The method described in this paper utilizes inexpensive, off-the-shelf, preevacuated, glass vials. Preevacuated vials have been used by others for the isotopic analysis of breath CO2 and are well tested. The vials can be purchased in bulk from scientific apparatus suppliers at a relatively low cost. These are coupled with a simplified extraction line consisting of a stainless steel syringe needle and a glass cold trap. Vials are filled with CO2 and H2O and shaken in a constant-temperature water bath for at least 90 min. Since the vials are discarded after use, no cleaning is necessary, essentially eliminating any memory effect. Reproducibility is generally better than +/- 0.05%. The only reagents required are gaseous CO2 for equilibration, a dry ice/alcohol mixture for trapping water, and liquid nitrogen for transferring the CO2.

NASA Discipline Number 52-10↗

Veggie Hardware Validation Test Preliminary Results and Lessons Learned

The Veggie hardware validation test, VEG-01, was conducted on the International Space Station during Expeditions 39 and 40 from May through June of 2014. The Veggie hardware and the VEG-01 experiment payload were launched to station aboard the SpaceX-3 resupply mission in April, 2014. Veggie was installed in an Expedite-the-Processing-of-Experiments-to-Space-Station (ExPRESS) rack in the Columbus module, and the VEG-01 validation test was initiated. Veggie installation was successful, and power was supplied to the unit. The hardware was programmed and the root mat reservoir and plant pillows were installed without issue. As expected, a small amount of growth media was observed in the sealed bags which enclosed the plant pillows when they were destowed. Astronaut Steve Swanson used the wet/dry vacuum to clean up the escaped particles. Water insertion or priming the first plant pillow was unsuccessful as an issue prevented water movement through the quick disconnect. All subsequent pillows were successfully primed, and the initial pillow was replaced with a backup pillow and successfully primed. Six pillows were primed, but only five pillows had plants which germinated. After about a week and a half it was observed that plants were not growing well and that pillow wicks were dry. This indicated that the reservoir was not supplying sufficient water to the pillows via wicking, and so the team reverted to an operational fix which added water directly to the plant pillows. Direct watering of the pillows led to a recovery in several of the stressed plants; a couple of which did not recover. An important lesson learned involved Veggie's bellows. The bellows tended to float and interfere with operations when opened, so Steve secured them to the baseplate during plant tending operations. Due to the perceived intensity of the LED lights, the crew found it challenging to both work under the lights and read crew procedures on their computer. Although the lights are not a safety hazard, for visual comfort crewmembers were advised to wear sunglasses when working with the plants and then they can lift glasses to read procedures. Steve Swanson had already trail-blazed this procedure when he initiated VEG-01. The temperature and humidity data logger was relocated mid-experiment to provide measurements on both sides of the unit. Images of the plants were downlinked weekly, and videos of installation and harvest were recorded. This imaging frequency was not sufficient to monitor and respond to changes in plant growth. Plants, samples, and data loggers will be returned on SpaceX-4, scheduled to return the fall of 2014. Lessons learned will be translated into hardware and operational modifications for future Veggie payloads.

International Space Station↗

Influence of Hydroponically Grown Hoyt Soybeans and Radiation Encountered on Mars Missions on the Yield and Quality of Soymilk and Tofu

Soybeans were chosen for hmar and planetary missions due to their nutritive value and ability to produce oil and protein for further food applications. However, soybeans must be processed into foods prior to crew consumption. Wilson et al. (2003) raised questions about (1) the influence of radiation (on germination and functional properties) that the soybeans would be exposed to during bulk storage for a Mars mission, and (2) the impact of using hydroponically grown versus field grown soybeans on the yield and quality of soyfoods. The influence of radiation can be broken down into two components: (A) affect of surface pasteurization to ensure the astronauts safety from food-borne illnesses (a Hazard Analysis Critical Control Point), and (B) affect of the amount of radiation the soybeans receive during a Mars mission. Decreases in the amount of natural antioxidants and free radical formation and oxidation induced changes in the soybean (lipid, protein, etc.) will influence the nutritional value, texture, quality, and safety of soyfoods made from them. The objectives of this project are to (1) evaluate the influence of gamma and electron beam radiation on bulk soybeans (HACCP, CCP) on the microbial load, germination, ease of processing, and quality of soymilk and tofu; (2) provide scale up and mass balance data for Advanced Life Support subsystems including Biomass, Solid Waste Processing, and Water Recovery Systems; and (3) to compare Hoyt field grown to hydroponically grown Hoyt soybeans for soymilk and tofu production. The soybean cultivar Hoyt, a small standing, high protein cultivar that could grow hydroponically in the AIMS facility on Mars) was evaluated for the production of soymilk and tofu. The quality and yield of the soymilk and tofu from hydroponic Hoyt, was compared to Vinton 81 (a soyfood industry standard), field Hoyt, IA 2032LS (lipoxygenase-free), and Proto (high protein and antioxidant potential). Soymilk and tofu were produced using the Japanese method. The soymilk was coagulated with calcium sulfate dihydrate. Soybeans and tofu were evaluated using chemical, microbial, and instrumental sensory methods. The surface radiation of whole dry soybeans using electron beam or gamma rays at 10 or 30 kGy did provide microbial safety for the astronauts. However, these doses caused oxidative changes that resulted in tofu with rancid aroma, darkening of the tofu, lower tofu yields, more solid waste, and loss of the ability of the seeds to germinate. While lower doses may reduce these problems, we lose the ability to insure microbial safety (cross-contamination) of bulk soybeans for the astronauts. Counter measures could include vacuum packaging, radiating under freezing conditions. A No Effect Dose for food quality, below 10 kGy needs to be determined. Better estimates of the radiation that the food will be exposed to need to determined and shared. Appropriate shielding for the food as well as the astronauts needs to be developed. The Hoyt soybean did not provide a high yielding, high quality tofu. A new small scale system for evaluating soybeans was developed using 50 g quantities of soybeans.

Wilson, Lester A.↗

Inexpensive and durable aerogel-based VIP cores

The goal of this project was development of low-cost aerogels to be used as cores of Vacuum Insulated Panels (VIP). The specific aims were: 1. Aerogels to be based on phenolic chemistry to minimize flammability. 2. Aerogels to be in monolithic form and to have mechanical properties sufficient to allow their use as cores of VIPs without collapsing after evacuation. 3. Aerogels to have a cost per kg lower than the cost of fumed silica, one of the most common VIP cores. The achievements are: 1. Phenolic aerogels have been fabricated in monolithic form with thermal conductivity of 0.023 W/m·K, density ~ 0.25 g/cm 3 and a modulus of compression > 10 MPa. The aerogels can withstand the stresses of VIP evacuation without any appreciable deformation. 2. Drying of aerogels was carried in the initial stages of the project via sublimation of frozen solvents, following the procedure described in M. F. Bertino and T. Selden, “Fabrication of Aerogels and Aerogel Composites by Ambient Pressure Sublimation of Frozen Solvents”, PCT/US20/39485. Monoliths as large as 30 x 30 x 2 cm can be fabricated with the proprietary ambient fabrication technique which are free of cracks and warping. 3. Cost analysis was carried out and refined multiple times, cost drivers were identified, and the fabrication procedure was streamlined. Our cost model yields an aerogel cost of $\$$5.78/kg, which compares well with the price of fumed silica ($\$$6.2/kg FOB New York as of March 2023). 4. The monoliths can be cut into custom shapes and used as VIP cores. Cores fabricated with our technique have a thermal conductivity λ = 0.011 W/m·K at a pressure >10 mbar. 5. A variant of the technology yielded fireproof materials, described in M. F. Bertino, T. Moon, G. Waller, J. Ko and D. Clifford, “Fireproof thermal insulation”, Provisional Patent Application 63/415,386. 6. A spin-off company was created (ThermaGel Innovations, Inc.) which licensed technologies developed under this award. PI Bertino is a board member of the newco which is now raising capital to build a pilot plant.

36 MATERIALS SCIENCE↗

Sample Materials Considerations for Curating and Processing Pristine MSR Samples

The perseverance rover is collecting and caching samples of Mars as part of the Mars 2020 mission, which represents the first leg of a multi-mission Mars Sample Return Campaign. The MSR Campaign is an international partnership that will result in delivery of the first martian samples to Earth that were not delivered through meteoritic infall. All meteorites, regardless of how they were handled from recovery to curation, have experienced uncontrolled entry and exposure to the terrestrial environment. Whilst meteorite deliveries are serendipitous, they are also unplanned events that require reactionary responses for recovery and curation. However, with the direct return of pristine astromaterials from another body, we are afforded the ability to design a facility in advance of sample delivery to keep those samples in a pristine (i.e., as returned) state for an indefinite period of time. Given that the curation and processing infrastructure needs to be made out of something, it is important to choose materials for the pristine curation environment that will optimize between the need to effectively process samples and the need to minimize contamination of the samples. The Johnson Space Center (JSC) has an optimized list of materials that have been used in previous sample return missions that includes 304/316 Stainless Steel, Teflon, and T6061 Aluminum (1). This set of materials are compatible with inorganic, organic, and biological cleanliness requirements and protocols. Furthermore, only these materials are permitted to come in contact with pristine samples. We note that JSC uses Neoprene and Hypalon for the gloves on their gloveboxes, but the glove material never comes in direct contact with the samples, only the approved materials. The MSR sample tubes will be made of Ti, so Ti may be an acceptable material for making tools, but the minor and trace element abundances of 304 and 316 stainless steel are well known and do not inhibit scientific investigations of metals, including HSE (2). More work is needed to determine whether the same is true for Ti alloys. In addition to defining the materials in the pristine environment, one must also choose whether the pristine environment will be under vacuum or under a specific atmospheric composition and pressure. Although JAXA has successfully implemented pristine curation vacuum chambers for their Hayabusa and Hayabusa2 samples (3), a vacuum environment is not appropriate for martian samples because it may drive deliquescence of mineral phases in the samples that are sensitive to pressure and relative humidity (4). Consequently, the pristine environment for the martian samples should be under an inert gas. It will be crucial to minimize the number of gases that come into direct contact with samples and these gases will need to be high purity and consistent throughout the pristine isolators. Samples at JSC are stored under high purity gaseous nitrogen (1). Dry N2 gas has not been a problem for N isotope studies for high-T release phases, but an additional inert atmosphere like Ar may be needed for samples where there is a particular concern about low-T release of N from bulk sample analysis. References: (1) McCubbin FM, et al. (2019) Space Science Reviews, 215, 1-81. (2) Day JMD, et al. (2018) Meteorit. Planet. Sci. 53:1283-1291. (3) Yada, T., et al., (2014). Meteorit. Planet. Sci. 49, 135-153. (4) Tosca NJ, et al. (2021). Astrobiology, in press, doi:10.1089/ast.2021.0115.

F M McCubbin↗

Ion concentration ratio measurements of ion beams generated by a commercial microwave electron cyclotron resonance plasma source

A commercially available electron cyclotron resonance (ECR) plasma source (GenII Plasma Source, tectra GmbH) is widely used for surface processing. This plasma source is compatible with ultrahigh vacuum systems, and its working pressure is relatively low, around 10 –6 –10 –4 Torr even without differential pumping. Here, we report ion flux concentration ratios for each ion species in an ion beam from this source, as measured by a mass/energy analyzer that is a combination of a quadrupole mass spectrometer, an electrostatic energy analyzer, and focusing ion optics. In this study, the examined beams were those arising from plasmas produced from feed gases of H 2 , D 2 , N 2 , O 2 , Ar, and dry air over a range of input power and working pressures. H 2 (D 2 ) plasmas are widely used for nuclear fusion applications and, hence, the ion concentration ratios of H + , H 2 + , and H 3 + reported here will be useful information for research that applies this plasma source to well-controlled plasma-material interaction studies. Ion energy distributions, stability of operation, and impurity concentrations were also assessed for each of the plasma species investigated.

47 OTHER INSTRUMENTATION↗

ESD Challenges for NASA Astronauts in Upcoming Missions

Electrostatic charging of insulators is well known to pose potential threats to electronic systems under terrestrial systems. We were asked to evaluate potential hazards associated with replacement of an electronics board in the vacuum of space during the upcoming Hubble Service Repair mission in September 2008. A device called a "tribot" was built to simulate triboelectric charging of several insulators that are capable of contact charging against astronaut's gloves and suit materials. Materials were evaluated as the extent of not only the magnitude of electric fields generated by the frictional action, but also any resulting discharge which would be a source of EMI. Experimental results are quite surprising and unexpected when compared with tests performed under ambient conditions under dry and humid air.

Buhler, Charles R.↗