Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIFFRACTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

X-ray Conversion Efficiencies for Diffraction Experiments on Z

We have used a deep-depletion CCD camera in single-hit mode to measure X-ray conversion efficiencies with Z-Beamlet and Z-Petawatt. Z-Petawatt is superior to Z-Beamlet for X-rays harder than 10 keV. For diffraction samples with Z > 42, we likely require X-rays with 15 keV or higher photon energy (Z-Petawatt). We are developing a robust, reproducible setup for X-ray polycapillaries as a part for X-ray diffraction experiments (XRD).

Geissel, Matthias↗

Tracing Phase Transformation and Lattice Evolution in a TRIP Sheet Steel under High-Temperature Annealing by Real-Time In Situ Neutron Diffraction

Real-time in situ neutron diffraction was used to characterize the crystal structure evolution in a transformation-induced plasticity (TRIP) sheet steel during annealing up to 1000 °C and then cooling to 60 °C. Based on the results of full-pattern Rietveld refinement, critical temperature regions were determined in which the transformations of retained austenite to ferrite and ferrite to high-temperature austenite during heating and the transformation of austenite to ferrite during cooling occurred, respectively. The phase-specific lattice variation with temperature was further analyzed to comprehensively understand the role of carbon diffusion in accordance with phase transformation, which also shed light on the determination of internal stress in retained austenite. These results prove the technique of real-time in situ neutron diffraction as a powerful tool for heat treatment design of novel metallic materials.

Yu, Dunji [ORNL] (ORCID:0000000189467851)↗

A Compact Cryogenic Environment for In Situ Neutron Diffraction Under Mechanical Loading

Understanding the deformation mechanisms of materials at cryogenic temperatures is crucial for cryogenic engineering applications. In situ neutron diffraction is a powerful technique for probing such mechanisms under cryogenic conditions. In this study, we present the development of a compact cryogenic environment (CCE) designed to facil-itate in situ neutron diffraction experiments under mechanical loading at tempera-tures as low as 77 K. The CCE features a polystyrene foam cryogenic chamber, alumi-num blocks serving as neutron-transparent cold sinks, a liquid nitrogen dosing system for cryogen delivery, a nitrogen gas flow control system for thermal management, a process controller for temperature control, and a pair of thermally isolated grip adapt-ers for mechanical testing. The CCE achieves reliable temperature control with mini-mal neutron attenuation. Utilizing this setup, we conducted three in situ neutron dif-fraction tensile tests on a 316L stainless steel at 77 , 173 , and 298 K, respectively. The results highlight the pronounced effects of cryogenic temperatures on the material's deformation mechanisms, underscoring both the significance of cryogenic deformation studies and the effectiveness of the CCE.

Yu, Dunji [ORNL] (ORCID:0000000189467851)↗

Diffractive Physics Program at the Electron–Ion Collider’s (EIC) 2 nd Detector

The Electron–Ion Collider (EIC) will be a novel experimental facility to explore the properties of gluons in nucleons and nuclei, shedding light on their structure and dynamics. The EIC community outlined the physics program of the EIC in a White Paper, and the demanding detector re quirements and potential technologies to deploy at an EIC detector were published in a comprehensive Yellow Report. The general-purpose detector resulting from these efforts, ePIC, is designed to perform a broad physics program. At the same time, the wider EIC community is strongly in favor of a second detector at the EIC. Having two general-purpose collider detec tors to support the EIC science program allows us to have cross-checks and control of systematic uncertainties for potential scientific discoveries. The second detector should feature complementary technologies where possible. It can also focus on specific measurements that are less well-addressed by ePIC. The second interaction region provides potentially improved forward detector acceptance at low pT and a secondary beam focus that enables to enhance the exclusive, tagging, and diffractive physics program. Hereby, I will present the potential capabilities of the second detector and discuss studies related to its diffractive physics program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Noise diffraction patterns eliminated in coherent optical systems

Lens rotation technique of noise diffraction pattern elimination spreads diffracted energy, normally concentrated over small area of image, over much larger annular area. Technique advantages include simplified lens selecting process, reduced clean room requirements, and low cost equipment requirements.

Grebowsky, G. R.↗

Ray tracing program with options for diffraction gratings

Diffraction theory, developed in vectorial form and coded into ray tracing routines, permits tracing rays of any wavelength through surfaces that are plane, spherical, conical, or aspheric polynomial. Ruled diffraction gratings may run in either X-direction or Y-direction, where Z is optical axis.

Howell, B. J.↗

Diffraction of a plane wave by a three-dimensional corner

By the superposition of the conical solution for the diffraction of a plane pulse by a three dimensional corner, the solution for a general incident plane wave is constructed. A numerical program is presented for the computation of the pressure distribution on the surface due to an incident plane wave of any wave form and at any incident angle. Numerical examples are presented to show the pressure signature at several points on the surface due to incident wave with a front shock wave, two shock waves in succession, or a compression wave with same peak pressure. The examples show that when the distance of a point on the surface from the edges or the vertex is comparable to the distance for the front pressure raise to reach the maximum, the peak pressure at that point can be much less than that given by a regular reflection, because the diffracted wave front arrives at that point prior to the arrival of the peak incident wave.

Ting, L.↗

High voltage electron microscopy and electron diffraction of pyroxenes in type B lunar samples from Apollo 11

Lunar pyroxene 10044 specimens cleaved and sectioned by diamond knife ultramicrotomy were examined by standard (75 to 100 kV) and high voltage (200 kV) electron microscopy and diffraction. Salient findings based on evaluation of 2000 plates show uniform 300 to 600 A-wide bands, probably corresponding to single crystal domains, with lattice spacings of 2. A High resolution bright and dark field images of iron-rich and magnesium-rich crystals were compared with corresponding electron diffraction patterns. Possible relations of observed structures to magnetic domains were considered.

Fernandez-Moran, H.↗

Electron microscopy and diffraction of layered, superconducting intercalation complexes.

Several layered, transition metal dichalcogenide intercalation complexes with unique superconducting properties have been examined by high-resolution electron microscopy and electron diffraction. Details of the crystalline lattice and of the lattice imperfections have been directly resolved. The results can be correlated with the available X-ray diffraction and chemical data, and they confirm and extend the postulated models.

Fernandez-Moran, H.↗

Optical grating evaluator - A device for detailed measurement of diffraction grating efficiencies in the vacuum ultraviolet

A device for detailed measurement of diffraction grating efficiencies and over-all performance in the VUV has been designed and constructed at the Naval Research Laboratory. The system employs semiautomated mechanisms to scan the face of the grating with a narrow monochromatic beam, and an efficiency map of the grating surface is produced on a strip chart recorder. Grating efficiency in the various diffracted orders and intensity of light scattered between orders may also be measured. A unique feature is the ability to determine the angle and effectiveness of grating blaze and variations in blaze under different conditions of illumination.

Michels, D. J.↗

Diffraction theory techniques applied to aperture antennas on finite circular and square ground planes

Expressions which represent the elevation-plane patterns of a large TEM mode coax aperture and a TM-01 mode circular aperture on finite circular and square ground planes have been derived using geometrical theory of diffraction; design curves for the coax case are presented. The expressions for the field pattern were obtained by superposing the infinite ground plane solutions, the first-order diffracted field solutions, and the axial caustic solutions in their respective regions of validity. The pattern analyses for the coax and circular apertures are verified experimentally.

Cockrell, C. R.↗

Pinhole diffraction filter

Multistage diffraction filter consisting of coalined series of pinholes on parallel sheets can be used as nondegradable UV filter. Beam is attenuated as each pinhole diffracts radiation in controlled manner into divergent beam, and following pinhole accepts only small part of that beam.

Woodgate, B. E.↗

Diffraction effects on angular response of X-ray collimators

Angular responses have been measured for X-ray collimators with half-widths ranging from minutes of arc down to 10 arcsec. In the seconds-of-arc range, diffraction peaks at off-axis angles can masquerade as side lobes of the collimator angular response. Measurements and qualitative physical arguments lead to a rule of thumb for collimator design; namely, the angle of first minimum in the Fraunhofer single-slit diffraction pattern should be less than one-fourth of the collimator geometrical full-width at half-maximum intensity.

Blake, R. L.↗

Diffraction of sound by nearly rigid barriers

The diffraction of sound by barriers with surfaces of large, but finite, acoustic impedance was analyzed. Idealized source-barrier-receiver configurations in which the barriers may be considered as semi-infinite wedges are discussed. Particular attention is given to situations in which the source and receiver are at large distances from the tip of the wedge. The expression for the acoustic pressure in this limiting case is compared with the results of Pierce's analysis of diffraction by a rigid wedge. An expression for the insertion loss of a finite impedance barrier is compared with insertion loss formulas which are used extensively in selecting or designing barriers for noise control.

Hadden, W. J., Jr.↗

Diffraction calculation of occultation light curves in the presence of an isothermal atmosphere

From diffraction theory, light curves are calculated for stellar occultations by a planetary body with an isothermal atmosphere. The character of the resulting curves is determined by the scale height H, the Fresnel zone size l, the surface atmospheric refractivity, and the planetary radius. An exact general solution and two approximations are presented which are valid when H is much greater than l. The importance is assessed of accounting for diffraction effects of the limb when deducing atmospheric parameters from occultation light curves

French, R. G.↗

Image contrast of diffraction-limited telescopes for circular incoherent sources of uniform radiance

A simple approximate formula is derived for the background intensity beyond the edge of the image of uniform incoherent circular light source relative to the irradiance near the center of the image. The analysis applies to diffraction-limited telescopes with or without central beam obscuration due to a secondary mirror. Scattering off optical surfaces is neglected. The analysis is expected to be most applicable to spaceborne IR telescopes, for which diffraction can be the major source of off-axis response.

Shackleford, W. L.↗