Simple tool removes IC flat packs

Handtool has bifurcated handle that can be tightened so that clamping head grips pack securely. Tool easily removes hybrid integrated-ciruit flat packs from printed-wiring boards. It does not damage circuit or board; thus, board can be reused with replacement circuit, and old circuit can be analyzed for faults and, if possible, repaired.

Eggebeen, J.↗

Slip sensor

Slippage of one surface, relative to another is detected by "ball bearing" magnetic sensor. Omnidirectional sensor responds to slippage in any direction. Sensor is mounted in "finger" of mechanical claw manipulator and signals operator who tightens grip by remote control when object slips.

Bejczy, A. K.↗

The 13th Aerospace Mechanisms Symposium

Technological areas covered include propulsion, motion compensation, instrument pointing and adjustment, centrifuge testing, bearing design, vehicle braking, and cargo handling. Devices for satellite, missile, and hypersonic-wind-tunnel applications; space shuttle mechanical and thermal protection systems; and techniques for building large space structures are described. In addition, a fluid drop injector device for a Spacelab experiment, a helical grip for cable cars, and applications of rare earth permanent magnets are discussed.

Bond, A. C.↗

Zero-torque spanner wrench

Wrench converts gripping action of hand to rotary motion without imparting reactive moments or forces on part being turned or on operator. Wrench should be useful in undersea operations and other delicate work where reactive forces and torques have to be controlled. In design for valve tightening, tool resembles cross between conventional spanner wrench and pilers. One handle engages valve body; second handle has ratchet pawl that engages toothed coupling ring on perimeter of valve handle. When operator squeezes wrench handles, valve handle rotates with respect to valve body.

Friedell, M. V.↗

Effects of method of loading and specimen configuration on compressive strength of graphite/epoxy composite materials

Three test schemes were examined for testing graphite/epoxy (Narmco T300/5208) composite material specimens to failure in compression, including an adaptation of the IITRI "wedge grip" compression fixture, a face-supported-compression fixture, and an end-loaded-coupon fixture. The effects of specimen size, specimen support arrangement and method of load transfer on compressive behavior of graphite/epoxy were investigated. Compressive stress strain, strength, and modulus data obtained with the three fixtures are presented with evaluations showing the effects of all test parameters, including fiber orientation. The IITRI fixture has the potential to provide good stress/strain data to failure for unidirectional and quasi-isotropic laminates. The face supported fixture was found to be the most desirable for testing + or - 45 s laminates.

Clark, R. K.↗

Project FIRES. Volume 4: Prototype Protective Ensemble Qualification Test Report, Phase 1B

The qualification testing of a prototype firefighter's protective ensemble is documented. Included are descriptions of the design requirements, the testing methods, and the test apparatus. The tests include measurements of individual subsystem characteristics in areas relating to both physical testing, such as heat, flame, impact penetration and human factors testing, such as dexterity, grip, and mobility. Also, measurements related to both physical and human factors testing of the complete ensemble, such as water protection, metabolic expenditures, and compatibility are considered.

Abeles, F. J.↗

Blind Fastener Is Easy To Install

Panels, sheets, doors and other structures could be easily attached to and removed from mating part by proposed new fastener. Fastener is permanently anchored in removable part only. Its protruding end is inserted into a hole in mating part. When wedge pin is screwed tightly closed, segmented collar contracts or expands to release parts or to grip them. Installation has no loose parts, and no rear nut is needed.

Peterson, S. A.↗

Cam-Design Torque Wrench

New Torque wrench for electrical connnectors automatically tightens its grip with increasing torque to insure against slippage. Tool requires only minimal clearance between connector and adjacent structures or components. Wrench is operated with one hand and can be used on connectors of various shapes.

Schick, P. H. J.↗

Articulated Vacuum Chuck

Vacuum chuck conforms to complex surface contours. Gripping surface is polyurethane panel embedded with links of roller chain. Panel flexes under vacuum to adjust to surface contour, and then bolts are tightened to lock configuration. Possible applications of new chuck are in pull-testing contoured surfaces, holding assemblies together for repairs, or for handling unusually-shaped parts.

Peterson, S. A.↗

Robot End Effector To Place and Solder Solar Cells

Encapsulated in robot end effector is RF induction-heating coil for heating solar cell while in transit. Holes in encapsulant permit end of unit to act as vacuum pickup to grip solar cell. Use of RF induction heating allows cell to be heated without requiring direct mechanical and thermal contact of bonding tool such as soldering iron.

Hagerty, J. J.↗

Tubing Cutter is Activated Hydraulically

Hydraulically-actuated tubing cutter severs tubing when operator squeezes handle grip. "Gooseneck" extension enables cutter to be used in areas where accessiblity is limited. Cutter has potential as flight-line tool and is useful in automobile and fire rescue work.

Mcsmith, D. G.↗

Pressure suit joint analyzer

A measurement system for simultaneously measuring torque and angular flexure in a pressure suit joint is described. One end of a joint under test is held rigid. A torque transducer is pivotably supported on the other movable end of a joint. A potentiometer is attached to the transducer by an arm. The wiper shaft of the potentiometer is gripped by a reference arm that rotates the wiper shaft the same angle as the flexure of joint. A signal is generated by the potentiometer which is representative of the joint flexure. A compensation circuit converts the output of the transducer to a signal representative of joint torque.

Vykukal, H. C.↗

Apparatus for sequentially transporting containers

Apparatus for transferring and manipulating a plurality of containers in a sequence is disclosed including a mechanical manipulator arm having a gripping device which automatically picks up a container at a fixed pickup position P and transfers it to a processing station. At a processing station X, the container is loaded with silicon wafers and thereafter returned by the arm to the fixed position P at the pickup and return station Y. A plurality of the containers may be processed in sequence from the fixed pickup position by providing a movable carriage upon which container pedestal platforms are supported, at least one of which is an elevator platform. The platforms include abutments for properly positioning the containers for accurate pickup by the manipulator arm.

Hudgins, J. L.↗

The enchanted loom

The evolution of intelligence began with the movement of Crossopterygian fish onto land. The eventual appearance of large dinosaurs eliminated all but the smallest of mammalian creatures, with the survivors forced to move only nocturnally, when enhanced olfactory and aural faculties were favored and involved a larger grey matter/body mass ratio than possessed by the dinosaurs. Additionally, the mammals made comparisons between the inputs of various senses, implying the presence of significant memory capacity and an ability to abstract survival information. More complex behavior occurred with the advent of tree dwellers (forward-looking eyes), hands, color vision, and the ability to grip and manipulate objects. An extra pound of brain evolved in the human skull in less than a million years. The neural processes that can lead to an action by a creature with a brain are mimicked by the basic AND and OR gates in computers, which are rapidly approaching the circuit density of the human brain. It is suggested that humans will eventually produce computers of higher intelligence than people possess, and computer spacecraft, alive in an electronic sense, will travel outward to explore the universe.

Jastrow, R.↗

The physiological effects of simultaneous exposures to heat and vibration

Determination of the effects of exposure to vibration on the body's ability to handle heat stress, and, if so, identification of the specific vibration parameters (frequency and intensity) for both whole-body (wbv) and segmental-body vibration (sbv) that would have the most detrimental effect on the body's ability to maintain thermal homeostasis were studied. Rectal and skin temperatures, heart rates, localized sweat rates, arm-segment blood perfusion rates, respiration rates, oxygen uptakes, and respiratory exchange ratios were measured in six men (22 to 33 yr) during simultaneous exposures to heat and vibration - either wbv or sbv, and during a heated 50 min recovery period. The heat conditions were T (sub db) = 43.5 + or - 0.5 C (mean + or S.E.M.), and RH = 20 + or - 4%. All vibration exposures were divided into two exposure conditions - identical frequencies but at a high intensity (HI) and a low intensity (LI) level. The HI wbv exposure was for 25 min/day at 5 Hz, 0.37 g-rms; 10 Hz, 0.46 g-rms; 16 Hz, 0.72 g-rms; 30 Hz, 1.40 g-rms; 80 Hz, 3.70 g-rms. The LI wbv exposure was for 2.5 hr/day at the same frequencies but at the following accelerations: 0.14 g-rms; 0.18 g-rms; 0.28 g-rms; 0.55 g-rms; 1.44 g-rms. During the sbv the subject stood and grasped a vibrating, in the Z-axis, hand grip with both hands.

Spaul, W. A.↗

Effect of load introduction in compression testing of composite laminates

Compression testing of composite materials is affected by the manner in which the compressive load is introduced. Two such effects are studied in this paper: (a) the constrained edge effect, in which transverse expansion of the edges is prevented while the axial load is introduced, and (b) nonuniform gripping, as manifested by inplane bending of the test specimen. The principle of minimum complementary energy is used to develop an analytical model that quantifies these two effects upon the measured elastic properties of laminated composites. Numerical results are presented for selected high-strength graphite/epoxy composites.

Reiss, R.↗

Quantification of Cross-coupling and Motion Feedthrough for Multiaxis Controllers Used in an Air Combat Flying Task

A real-time piloted simulation of an air-to-air combat flying task using a wings-level-turn aircraft and various novel controllers was conducted. One objective is to quantify how the pilot interacts with the controllers and control modes, including: (1) controller versus aircraft response; (2) proprioceptive cross-coupling among axes of the controllers; and (3) biodynamic cross-coupling between the aircraft motions and the controllers. In order to aid in identifying the items listed above, both the target aircraft and the large amplitude multimode aerospace research simulator (LAMARS) motion system were distributed with quasi-random sums-of-sinusoids. Since the disturbances were separated in frequency, spectral analysis techniques were used to identify the three items listed. The results of the spectral analysis of controller motions from the two-axis side stick, a twist grip mounted on the side stick, a thumb button mounted on the side stick, and conventional rudder pedals are presented. Conclusions and recommendations for further research are also presented.

Jewell, W. E.↗

A balloon-borne imaging gamma-ray telescope

A balloon-borne coded-aperture gamma-ray telescope for galactic and extragalactic astronomy observations is described. The instrument, called GRIP (Gamma Ray Imaging Payload), is designed for measurements in the energy range from 30 keV to 5 MeV with an angular resolution of 0.6 deg over a 20 deg field of view. Distinguishing characteristics of the telescope are a rotating hexagonal coded-aperture mask and a thick NaI scintillation camera. Rotating hexagonal coded-apertures and the development of thick scintillation cameras are discussed.