Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE CONTRAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

'Edge illumination' in X-ray Phase Contrast Imaging

In the late '90s, the concept of 'edge illumination' was developed at ELETTRA in Italy as an alternative method to increase the phase sensitivity of an imaging system. The main idea was to be able to reproduce the fine angular selection of 'analyzer' crystals without actually using a crystal, as this would allow employing the method with divergent and polychromatic (i.e. conventional) x-ray sources. It was observed that this could be achieved by illuminating only the edges of the detector pixels, and that the method's sensitivity could be progressively increased by illuminating smaller pixel fractions closer to its physical edge. A few years later the idea was adapted for use with a conventional source by means of two sets of x-ray masks ('coded aperture' masks), which enabled obtaining the same effect for each row (or column) of pixels of an area detector illuminated by a cone beam. This article reviews the method and presents recent examples of application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser speckle contrast imaging of cerebral autoregulation in rats at a macro- and microcirculation level

Using the method of laser speckle imaging for the simultaneous study of macro- and microcirculation in cerebral vessels of healthy rats, we show that the mechanisms underlying cerebral autoregulation depend on the initial condition of the organism and the sex of individual animals. The pharmacological dose-dependent stimulation of the peripheral arterial pressure increase is not accompanied by the cerebral circulation responses of analogous intensity, but manifests itself as 'compensating' reactions, namely, the redistribution of the blood flow at the level of macro- (in females) and microcirculation (in females and males). The obtained results extend our understanding of the capabilities of laser speckle imaging technique in neurophysiological studies of reserve abilities of cerebral circulation autoregulation under the conditions of hypertensive status formation. (laser biophotonics)

60 APPLIED LIFE SCIENCES↗

A UNIFORM ANALYSIS OF 118 STARS WITH HIGH-CONTRAST IMAGING: LONG-PERIOD EXTRASOLAR GIANT PLANETS ARE RARE AROUND SUN-LIKE STARS

We expand on the results of Nielsen et al., using the null result for giant extrasolar planets around the 118 target stars from the Very Large Telescope (VLT) NACO H- and Ks-band planet search (conducted by Masciadri and collaborators in 2003 and 2004), the VLT and MMT Simultaneous Differential Imager survey, and the Gemini Deep Planet Survey to set constraints on the population of giant extrasolar planets. Our analysis is extended to include the planet luminosity models of Fortney et al., as well as the correlation between stellar mass and frequency of giant planets found by Johnson et al. Doubling the sample size of FGKM stars strengthens our conclusions: a model for extrasolar giant planets with power laws for mass and semimajor axis as given by Cumming et al. cannot, with 95% confidence, have planets beyond 65 AU, compared to the value of 94 AU reported by Nielsen et al., using the models of Baraffe et al. When the Johnson et al. correction for stellar mass (which gives fewer Jupiter-mass companions to M stars with respect to solar-type stars) is applied, however, this limit moves out to 82 AU. For the relatively new Fortney et al. models, which predict fainter planets across most of parameter space, these upper limits, with and without a correction for stellar mass, are 182 and 234 AU, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Design considerations for an ultrahigh-bandwidth Phase Contrast Imaging system applied to fusion grade devices

Abstract The PCI diagnostic is an internal reference interferometer that creates an image of absolutely calibrated electron density fluctuations integrated along the line of sight of the probing light beam. While conventional PCI diagnostics installed on fusion experiments worldwide employ light of wavelength equal to 10.59 μm, the same system using light at 1.55 μm wavelength would extend the spectral response in wave-number and frequency by factors of seven and over one hundred, respectively, thereby potentially providing quantitative measurements of the internal structure of density perturbations induced by either turbulent or radio-frequency waves, simultaneously covering ion to electron gyro-radius scales up to the GHz frequency region. Based on a previously developed 1.55 μm PCI prototype system, constraints to the design for such a diagnostic in fusion grade devices are presented and compared to those faced with the conventional method.

Instruments & Instrumentation↗

Continuous measurement feedback control of a Bose-Einstein condensate using phase-contrast imaging

We consider the theory of feedback control of a Bose-Einstein condensate (BEC) confined in a harmonic trap under a continuous measurement constructed via nondestructive imaging. A filtering theory approach is used to derive a stochastic master equation (SME) for the system from a general Hamiltonian based upon system-bath coupling. Numerical solutions for this SME in the limit of a single atom show that the final steady-state energy is dependent upon the measurement strength, the ratio of photon kinetic energy to atomic kinetic energy, and the feedback strength. Simulations indicate that for a weak measurement strength, feedback can be used to overcome heating introduced by the scattering of light, thereby allowing the atom to be driven toward the ground state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noninterferometric phase-contrast images obtained with incoherent x-ray sources

We report on what are believed to be the first full-scale images obtained with the coded aperture concept, which uses conventional x-ray sources without the need to collimate/aperture their output. We discuss the differences in the underpinning physical principles with respect to other methods, and explain why these might lead to a more efficient use of the source. In particular, we discuss how the evaluation of the first imaging system provided promising indications on the method's potential to detect details invisible to conventional absorption methods, use an increased average x-ray energy, and reduce exposure times--all important aspects with regards to real-world implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Referenceless, grating-based, single shot X-ray phase contrast imaging with optimized laser-driven K-α sources

With its ability to efficiently probe low-Z materials, X-ray phase imaging methods have recently raised high interest in multiple fields from biology and medical applications to high energy density (HED) physics. Initially developed with synchrotron light and X-ray tubes, we present a novel grating based Talbot X-ray deflectometer (TXD) diagnostic that was coupled with laser-generated K-α X-ray sources. The multi-terawatt laser (I > 1 × 10 14 W cm -2 ) was used as a testbed for diagnostic development. It was found that X-ray source chromaticity plays an important role in TXD. Indeed, the broadband spectrum of laser-generated X-ray sources may strongly impact image quality and thus diagnostic performance. We qualified X-ray emission from different laser-produced sources and determined laser, target, and deflectometer parameters that optimize TXD performance. We present the first results of referenceless grating-based X-ray imaging at high-power laser facilities and discuss the implications of this new development in HED research.

47 OTHER INSTRUMENTATION↗

Direct detection system for full-field nanoscale X-ray diffraction-contrast imaging

Recent developments in X-ray science provide methods to probe deeply embedded mesoscale grain structures and spatially resolve them using dark field X-ray microscopy (DFXM). Extending this technique to investigate weak diffraction signals such as magnetic systems, quantum materials and thin films prove challenging due to available detection methods and incident X-ray flux at the sample. We present a direct detection method developed in conjunction with KAImaging which focuses on DFXM studies in the hard X-ray range of 10s of keV and above capable of approaching nanoscale resolution. Additionally, we compare this direct detection scheme with routinely used scintillator-based optical detection and achieve an order of magnitude improvement in exposure times allowing for imaging of weakly diffracting ordered systems.

47 OTHER INSTRUMENTATION↗