Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical Impedance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Electrochemical characterization of evolving ionomer/electrocatalyst interactions throughout accelerated stress tests

Here, the degradation of polymer electrolyte membrane fuel cells (PEMFCs) catalyst layers used for heavy-duty vehicles was examined using a catalyst-specific accelerated stress test (AST). High surface area carbon supported dispersed Pt (Pt/HSC), annealed Pt (a-Pt/HSC) and PtCo (PtCo/HSC) alloy catalysts were examined over the course of 90,000 cycles by measuring changes in mass activity, O 2 transport resistance, electrochemical active surface area (ECSA), catalyst accessibility and ionomer-electrocatalyst interactions. Compared to a-Pt/HSC and Pt/HSC catalyst, the PtCo/HSC showed better initial mass activity, a larger initial mass transport loss, and faster degradation after the first 30k AST cycles, as a large portion of Co leached out during potential cycling. Pt/HSC showed higher initial performance relative to a-Pt/HSC but had faster degradation. STEM characterizations show that the ECSA losses are largely related to Pt dissolution resulting in either catalyst particle growth via the Ostwald ripening mechanism or redeposition in the membrane. Catalyst accessibility measurements showed decreased RH sensitivity for all three samples, while CO impedance measurements revealed a decrease in both Pt-water and carbon-water interactions. This implies that, Pt is either preferentially redepositing on the exterior of the carbon support, or that the ionomer is undergoing morphological changes enabling the enhanced intrusion of mesopores.

25 ENERGY STORAGE↗

Unravelling fast-charging degradation in NMC/Gr pouch cells: Lithium plating and SEI properties

As fast-charging technology expands across the electric vehicle and emerging energy-storage applications, understanding its impact on battery performance and longevity is critical. In this study, 1.8 Ah LiNi 0.6 Mn 0.2 Co 0.2 O 2 /graphite pouch cells were charged at various charging rates (0.5C, 2C, 4C, and 6C) to investigate the degradation mechanisms. Our results showed that well-designed NMC/Gr pouch cells could reach over 1000 cycles with a 2C charging rate, while only reaching around 500 cycles with 4C and 6C charging rates. Fast-charging effects on NMC and graphite electrodes were obtained through a series of post-mortem characterizations, including electrochemical impedance spectroscopy (EIS), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS). Although higher charging rates cause pulverization of NMC secondary particles, the dominant degradation mechanism driving the fading of fast-charging-related performance lies in the graphite anode, where lithium plating and LiF-rich solid electrolyte interphase (SEI) formation result in Li inventory loss and impedance growth. The postmortem results suggest that the formation of a LiF-rich SEI, which exacerbates anode impedance and some irreversible Li + ion loss, is likely driven by the substantial decomposition of PF 6 − during fast charging, an effect often overlooked in smaller laboratory-scale studies.

Luo, Mei [Argonne National Laboratory (ANL), Argon↗

Nano-Engineered Interfaces in Dual-Layer Electrodes for Protonic Ceramic Cells with Enhanced Stability and Kinetics

Enhancing interfacial stability and charge transfer in protonic ceramic cells (PCCs) remains a critical challenge, as structural degradation and interfacial resistance often compromise durability and efficiency. Here, we report a nanoengineered dual-layer oxygen electrode architecture designed to address these limitations by introducing a fine-grained nanoparticle interfacial contact layer beneath a porous catalytic backbone. The nanoscale powders, through enhanced sintering activity, densify into a robust interfacial layer that promotes strong chemical bonding, uniform adhesion, and continuous ionic/electronic pathways with the BCZYYb electrolyte. This hierarchical architecture mitigates delamination, redistributes mechanical stress, and establishes efficient charge and mass transport channels without relying on corrosive surface treatments. Electrochemical evaluation demonstrates that the dual-layer design markedly reduces interfacial polarization resistance and accelerates electrode kinetics. Compared to the single-layer counterpart, the architecture achieves a peel strength of 44.53 N/cm 2 , a 40% improvement in peak power density (0.96 W cm –2 at 600 °C), and a 130% enhancement in electrolysis current density (4.78 A cm –2 at 1.57 V). Faradaic efficiency remains as high as 88% under high steam concentrations, underscoring minimal charge loss during practical operation. Notably, the electrode retains stability across 450–600 °C and under transient voltage cycling, with impedance spectra confirming suppressed interfacial resistance growth over prolonged use. These results highlight nanoscale interface engineering as a powerful route to enhance both mechanical robustness and electrochemical kinetics in PCCs. The demonstrated scalability and durability of this architecture provide a versatile platform for advancing solid-state electrochemical systems, including reversible fuel cells and high-efficiency hydrogen production technologies.

Faradaic efficiency↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Microstructural, Corrosion and Mechanical Characterization of Friction-Stir Welded Joints Between Aluminum and Magnesium Alloys

Friction Stir Welding (FSW) of Aluminum-Magnesium (Al-Mg) alloys has garnered increasing attention due to its wide-ranging applications in the automotive and aerospace industries. The microstructural, corrosion, and mechanical properties of FSW Al-Mg welds under selected conditions are critical factors that must be well-investigated to ensure their durability and performance. In this study, electrochemical tests, including Open Circuit Potential (OCP), Linear Polarization Resistance (LPR), Potentiodynamic Polarization Scan (PD), and Electrochemical Impedance Spectroscopy (EIS), have been used to analyze the corrosion resistance of these welds, along with weight loss measurements through cyclic corrosion testing (CCT) and surface evolution via SEM over an 8-week period. Mechanical properties are evaluated through microindentation, nanoindentation, fatigue, and lap-shear tests. The results of the electrochemical tests reveal that the corrosion properties of the center weld zone differ from those of the two base alloys. Indentation tests indicate that the weld zone behaves differently from the base alloys. Surprisingly, the lap shear strength did not decrease significantly even after 8 weeks of cyclic corrosion testing, indicating that the joint prevented any ingress of the electrolyte. Fatigue testing showed that applying an adhesive between the Al and Mg joint improved the fatigue life to some extent, although the corrosion resistance reduced due to the discontinuous bonding of the adhesive layer. Overall, these findings highlight the importance of investigating the corrosion and mechanical properties of FSW Al-Mg welds and provide valuable insights for future modeling works.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impedance Controlled Twisted String Actuators for Tensegrity Robots

We are developing impedance controlled twisted string actuators (TSA) for use in tensegrity robots, as an alternative to traditional spooled cable actuation. Tensegrity robots are composed of continuous tension and discontinuous compression elements, with no rigid joints between elements, which give them unique force distribution properties. The use of tensegrity robots is strongly motivated by biological examples, and they are capable of locomotion and manipulation by changing lengths of their continuous network of tensional elements, which is also the primary pathways for load transfer through the structure. TSA show the potential to address some of the unique engineering challenges faced by tensegrity structures, and provide unique qualities well suited to an actively controlled tension system, such as compact, light-weight mechanical structures, inherent compliance, variable gearing'', and the ability to transmit high forces with a very low input torque. The inherent variable compliance of impedance control is essential for tensegrity robots to move through and manipulate the environment, and is a natural match to the unique qualities of TSA. This paper briefly introduces the tensegrity robots in the NASA Ames Intelligent Robotics Group and an overview of their future application to space planetary exploration. Then the effectiveness and robustness of TSA are verified through the performance of impedance control modes.

Park, In-Won↗

The Two-Cavity Method for Characterizing Acoustical Materials—an Interlaboratory Study

This study focuses on understanding the sound absorption characteristics of porous acoustic materials, which are determined by two key parameters independent of material thickness: characteristic impedance and propagation constant. These parameters can be characterized by testing a porous sample concept in a normal incidence impedance tube using either the two-thickness or the two-cavity method. In the two-thickness method, two samples of varying thicknesses are required. In contrast, the two-cavity method requires testing one sample at two different air cavity depths behind the porous material. This method is particularly advantageous for materials that are costly or challenging to fabricate. This interlaboratory study evaluates the variability of characteristic properties determined using the two-cavity method. Porous acoustic materials were additively manufactured and tested in the Liner Technology Facility(LTF)at NASA Langley Research Center and the Mechanics, Acoustics and Dynamics Lab (MADLab) at Michigan Technological University. The characteristic properties derived from various cavity depth combinations were used to predict the surface impedance of the sample with a rigid backing. The prediction was then compared the measured impedance spectrum. It was also found that the combinations of cavity depths can significantly influence the accuracy of the deduced properties.

acoustic liners↗

Ability of Impedance-Based Health Monitoring To Detect Structural Damage of Propulsion System Components Assessed

Impedance-based structural-health-monitoring uses piezoelectric (PZT) patches that are bonded onto or embedded in a structure. Each individual patch behaves as both an actuator of the surrounding structural area as well as a sensor of the structural response. The size of the excited area varies with the geometry and material composition of the structure, and an active patch is driven by a sinusoidal voltage sweep. When a PZT patch is subjected to an electric field, it produces a mechanical strain; and when it is stressed, it produces an electric charge. Since the patch is bonded to the structure, driving a patch deforms and vibrates the structure. The structure then produces a localized dynamic response. This structural system response is transferred back to the PZT patch, which in turn produces an electrical response. The electromechanical impedance method is based on the principle of electromechanical coupling between the active sensor and the structure, which allows researchers to assess local structural dynamics directly by interrogating a distributed sensor array. Because of mechanical coupling between the sensor and the host structure, this mechanical effect is picked up by the sensor and, through electromechanical coupling inside the active element, is reflected in electrical impedance measured at the sensor s terminals.

Martin, Richard E.↗

Thermoelectric coolers for high-power-density 3D electronics heat management

Future advancements in three-dimensional (3D) electronics require robust thermal management methodology. Thermoelectric coolers (TECs) are reliable and solid-state heat pumping devices with high cooling capacity that can meet the requirements of emerging 3D microelectronic devices. In this work, we first provide the design of TECs for electronics cooling using a computational model and then experimentally validate the main predictions. Key device parameters such as device thickness, leg density, and contact resistance were studied to understand their influence on the performance of TECs. Our results show that it is possible to achieve high cooling power density through optimization of TE leg height and packing density. Scaling of TECs is shown to provide ultra-high cooling power density.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overcoming Challenges to Continuous Integration in HPC

Continuous integration (CI) has become a ubiquitous practice in modern software development, with major code hosting services offering free automation on popular platforms. CI offers major benefits, as it enables detecting bugs in code prior to committing changes. While high-performance computing (HPC) research relies heavily on software, HPC machines are not considered “common” platforms. This presents several challenges that hinder the adoption of CI in HPC environments, making it difficult to maintain bug-free HPC projects, and resulting in adverse effects on the research community. Here we explore the challenges that impede HPC CI, such as hardware diversity, security, isolation, administrative policies, and non-standard authentication, environments, and job submission mechanisms. We propose several solutions that could enhance the quality of HPC software and the experience of developers. Implementing these solutions would require significant changes at HPC centers, but if these changes are made, it would ultimately enable faster and better science.

97 MATHEMATICS AND COMPUTING↗

Method and apparatus for determination of material residual stress

A device for the determination of residual stress in a material sample consisting of a sensor coil, adjacent to the material sample, whose resistance varies according to the amount of stress within the material sample, a mechanical push-pull machine for imparting a gradually increasing compressional and tensional force on the material sample, and an impedance gain/phase analyzer and personal computer (PC) for sending an input signal to and receiving an input signal from the sensor coil is presented. The PC will measure and record the change in resistance of the sensor coil and the corresponding amount of strain of the sample. The PC will then determine, from the measurements of change of resistance and corresponding strain of the sample, the point at which the resistance of the sensor coil is at a minimum and the corresponding value and type of strain of the sample at that minimum resistance point, thereby, enabling a calculation of the residual stress in the sample.

Chern, Engmin J.↗

Niobium addition improves the corrosion resistance of TiHfZrNb x high-entropy alloys in Hanks’ solution

High-strength TiHfZrNb x high-entropy alloys could become the ideal materials for small-diameter endovascular stents once their corrosion resistance in the physiological milieu is confirmed. Here, this work aims at evaluating the corrosion resistance of a TiHfZrNb x high-entropy-alloys family in Hanks’ solution at 37 °C and revealing the influence of niobium on the mechanisms of dissolution and passivation. The alloys were subjected to a series of static and dynamic electrochemical tests and surface characterization, employing the static/dynamic/cyclic polarizations, impedance spectroscopy, XPS, AFM, and SEM. Results confirm a higher corrosion resistance of the alloys compared to that of CP-Ti and Ti6Al4V. The addition of niobium considerably improves the microstructural homogeneity that ensures a low dissolution rate and a greater resistance of the film due to the lower concentration of point defects. The passive film behaves as an n-type semiconductor and is composed of a mixture of TiO 2 , Nb 2 O 5 , ZrO 2 , and HfO 2 oxides, with the presence of metallic hydroxides on the outermost layer. A detailed description of the niobium influence on the mechanisms of the dissolution and passivation is presented in this work.

36 MATERIALS SCIENCE↗

Probing phonon softening in ferroelectrics by scanning probe microwave spectroscopy

Microwave measurements have recently been successfully applied to measure ferroelectric materials on the nanoscale, including detection of polarization switching and ferroelectric domain walls. In this study we discuss the question of whether scanning probe microscopy operating at microwave frequency can identify the changes associated with the soft phonon dynamics in a ferroic. The analytical expressions for the electric potential, complex impedance, and dielectric losses are derived and analyzed, since these physical quantities are linked to experimentally measurable properties of the ferroic. As a ferroic we consider virtual or proper ferroelectric with an optic phonon mode that softens at a Curie point. We also consider a decay mechanism linked to the conductance of the ferroic, thus manifesting itself as the dielectric loss in the material. Our key finding is that the influence of the soft phonon dispersion on the surface potential distribution, complex impedance, and dielectric losses are evidently strong in the vicinity (~10–30 K) of the Curie temperature. Additionally, we quantified how the spatial distribution and frequency spectra of the complex impedance and the dielectric losses react on the dynamics of the soft phonons near the Curie point. These results set the stage for characterization of polar phase transitions with nanoscale microwave measurements, providing a complementary approach to well established electromechanical measurements for fundamental understanding of ferroelectric properties as well as their applications in telecommunication and computing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unraveling the Mechanism of Water-Mediated Sulfur Tolerance via Operando Surface-Enhanced Raman Spectroscopy

While several proton-conducting anode materials have shown excellent tolerance to sulfur poisoning, the mechanism is still unclear due largely to the inability to probe miniscule amounts of sulfur-containing species using conventional surface characterization techniques. Here we present our findings in unraveling the mechanism of water-mediated sulfur tolerance of a proton conductor under operating conditions empowered by surface-sensitive, operando surface-enhanced Raman spectroscopy (SERS) coupled with impedance spectroscopy. Contrary to the conventional view that surface-adsorbed sulfur is removed mainly by oxygen anions, it is found that –SO 4 groups on the surface of the proton conductor are converted to SO 2 by a water-mediated process, as confirmed by operando SERS analysis and density functional theory (DFT)-based calculations. Furthermore, the combination of operando SERS performed on a model electrode and theoretical computation offers an effective approach to investigate into complex mechanisms of electrode processes in various electrochemical systems, providing information vital to achieve the rational design of better electrode materials.

25 ENERGY STORAGE↗

The Effects of Morphology and Hydration on Anion Transport in Self-Assembled Nanoporous Membranes

Ordered nanoporous polymer membranes offer opportunities for systematically probing the mechanisms of ion transport under confinement and for realizing useful materials for electrochemical devices. Here, we examine the impact of morphology and ion hydration on the transport of hydroxide and bromide anions in nanostructured polymer membranes with 1 nm scale pores. We use aqueous lyotropic self-assembly of an amphiphilic monomer, with a polymerizable surfactant to create direct hexagonal (H I ) and gyroid mesophases. UV-induced cross-linking leads to the formation of nanoporous polymers with water continuous channels. The membranes are mechanically robust and chemically durable, resisting degradation during extended exposure to 1 M NaOH solutions. We use a combination of electrochemical impedance spectroscopy, pulsed-field gradient NMR spectroscopy, and molecular simulations to elucidate anion and water transport. The as-prepared hexagonal systems display higher conductivity and lower activation energies for both anions relative to the gyroid system. When compared at equivalent hydration, however, gyroid and hexagonal membranes show similar activation energies, with nearly identical conductivities at ambient temperatures. Both ionic conductivity and water diffusivity increase with increasing hydration. Here, the water uptake as a function of relative humidity for the hexagonal and gyroid mesophases ultimately dictates the water diffusion and magnitude of the ionic conductivity, with the hexagonal system showing overall higher capacity for hydration and thus faster ion transport. The durability of these materials under aggressive alkaline conditions and their relatively high hydroxide ion conductivity suggest that these nanostructured polymers could be of interest as membranes for alkaline fuel cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.

30 DIRECT ENERGY CONVERSION↗

Random and systematic measurement errors in acoustic impedance as determined by the transmission line method

The effect of random and systematic errors associated with the measurement of normal incidence acoustic impedance in a zero-mean-flow environment was investigated by the transmission line method. The influence of random measurement errors in the reflection coefficients and pressure minima positions was investigated by computing fractional standard deviations of the normalized impedance. Both the standard techniques of random process theory and a simplified technique were used. Over a wavelength range of 68 to 10 cm random measurement errors in the reflection coefficients and pressure minima positions could be described adequately by normal probability distributions with standard deviations of 0.001 and 0.0098 cm, respectively. An error propagation technique based on the observed concentration of the probability density functions was found to give essentially the same results but with a computation time of about 1 percent of that required for the standard technique. The results suggest that careful experimental design reduces the effect of random measurement errors to insignificant levels for moderate ranges of test specimen impedance component magnitudes. Most of the observed random scatter can be attributed to lack of control by the mounting arrangement over mechanical boundary conditions of the test sample.

Parrott, T. L.↗