Search NASA⌕ Search

SEARCH · Search NASA

Results for “NANOSECOND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

EMP-Resilient Electric Grid Transformer Analysis

The response of a high - voltage (HV) transformer to fast rise time voltages, such as that from a electromagnetic pulse (EMP) can result in interruption of power distribution and possibly system failure. To help identify these potential occurrences, it is necessary to develop a transformer model that not only captures the input/output response of the transformer but also the internal behavior. The model constructed should cover the frequency band of interest while capturing the internal physical and electrical characteristics. This broad-band, high-fidelity model would enable the prediction of unwanted effects through simulation. A proposed modeling scheme for a HV transformer is described in Part 1 of this report. Part 2 of this report details assessments of internal voltage and electrical field holdoff testing of transformer insulation dielectric breakdown, including comparison of low frequency (DC/60 Hz) holdoff to rise times characteristic of lightning (1 s) and EMP E1 transients (10 - 30 ns). This initial project is a path toward establishing electrical grid transformer failure criteria for EMP voltage transients. We developed modeling methods and measured breakdown electrical field statistical distributions for direct current, 60 Hz, lightning and EMP characteristic voltage rise times. Methods of nanosecond-scale capacitive discharge unit high voltage source development, suggestions for derating of 60 Hz insulation maximum electrical fields for EMP nanosecond pulse voltage withstand rating, and potential methods for increasing transformer resilience to such fast rise time pulses are described.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phase Transitions in (Mg,Fe) 2 SiO 4 Olivine under Shock Compression

The response of forsterite, Mg 2 SiO 4 , under dynamic compression is of fundamental importance for understanding its phase transformations and high-pressure behavior. Here, we have carried out an in situ X-ray diffraction study of laser-shocked polycrystalline and single-crystal forsterite from 19 to 122 GPa using the Matter in Extreme Conditions end-station of the Linac Coherent Light Source. Under laser-based shock loading, forsterite does not transform to the high-pressure equilibrium assemblage of MgSiO 3 bridgmanite and MgO periclase, as has been suggested previously. Instead, we observe forsterite and forsterite III, a metastable polymorph of Mg 2 SiO 4 , coexisting in a mixed-phase region from 33 to 75 GPa for both polycrystalline and single-crystal samples. Densities inferred from X-ray diffraction are consistent with earlier gas-gun shock data. At higher stress, the response is sample-dependent. Polycrystalline samples undergo amorphization above 79 GPa. For [010]- and [001]-oriented crystals, a mixture of crystalline and amorphous material is observed to 108 GPa, whereas the [100]-oriented forsterite adopts an unknown phase at 122 GPa. The first two sharp diffraction peaks of amorphous Mg 2 SiO 4 show a similar trend with compression as those observed for MgSiO 3 in both recent static- and laser-driven shock experiments. This study provides new insight into the transformation of forsterite under nanosecond-duration shock loading. This work emphasizes the importance of formation of metastable phases along the Hugoniot and adds to evidence that the 300-K single-crystal diamond anvil cell experiments have relevance for understanding structures formed under shock compression. In particular, the metastable phase forsterite III has now been shown to form under dynamic compression from 10s to 100s of nanoseconds as well as under 300-K static compression. Upon compression to higher pressures, Mg 2 SiO 4 transforms to an amorphous phase. These results have broad relevance for understanding the behavior of silicates under dynamic compression.

36 MATERIALS SCIENCE↗

A multi-institution collaboration to study copper wire hybrid and laser-cut foil X-pinches

X-pinches are a pulsed power wire-array configuration that produce nanosecond and micron-scale X-ray sources with numerous applications. The earliest embodiment of the X-pinch inspired its name, as it is typically composed of two or more fine (5-50 µm) wires crossed into the shape of an X (Fig. 1a). The ‘X’ ablates when subjected to large (10 1 -10 4 kA), fast-rising (~1 kA/ns) currents, and extreme magnetic pressure at the cross-point constricts the ablated plasma, which develops instabilities and then pinches to near-zero radius, localized ‘hot spots’, emitting X-rays from a sub-nanosecond and 1 µm scale source characteristic of a hot (~1 keV), dense (10% solid density) plasma. A subsequent gap forms where the hot spot(s) occurred, across which substantial potential accelerates electron beams (e-beams) that generate larger, longer-lasting X-ray bursts composed of harder X-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Imaging And Assessment Of Non-Perturbing Magnetic Diagnostics For Intermediate-Density Fusion Experiments

This research adds to the understanding of when, why, where, and how fusion-grade plasmas generate X-rays. Normal fusion reactions create different spectra of X-rays from unwanted spurious situations so examination of the X-ray spectra provides information on whether a fusion device is operating properly or not. The characteristic time scale of the X-rays ranges from a few nanoseconds to a microseconds so a movie camera having a very high framing rate is required. The energy of the X-rays is not known and so the camera should provide information on what this energy is. The mechanism by which the X-rays are generated varies depend on whether the X-rays are from normal operation or from unwanted spurious effects. This project developed prototypes of a high-speed X-ray movie camera using two different technologies. These were tested on pulsed plasma experiments at Caltech. Despite having modest plasma parameters these experiments generated transient X-ray bursts suitable for developing and testing these cameras. One of the cameras was used on the MIFTI fusion-related experiment at UCSD and provided information on the energy, location, and timing of X-rays produced there. The camera could measure X-rays having energies from about 5 kilovolts to about 30 kilovolts with 40 nanosecond time resolution and space resolution of a few mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sampling Rare Events in Aqueous Systems Using Molecular Simulations

Birth of a new distinct phase is a phenomenon encountered in a myriad of processes, and has wide ranging consequences in material processing, biological self-assembly, separations and several other processes. Several phase transitions are nucleation driven. The nucleation events occur over nanosecond timescales and involve hundreds to thousands of molecules. These length and timescales are difficult to access in experiments, thereby making experimental studies of nucleation challenging. On the other hand, molecular simulations sample the nanosecond and nanometer scales making them ideal to study nucleation. However, nucleation is a rare event, meaning that the waiting time to observe one nucleation event is significant. This makes simulation studies of rare events challenging. The project focused on a multi-pronged approach to address such challenges to develop the next generation rare event sampling methods for molecular simulations. The key outcomes of our work include developing more effective methods for sampling rare events, utilizing machine learning to better elucidate nucleation mechanisms, development of software for easy implementation of the methodologies, and applications of the methods to realistic systems to push the method applicability beyond model systems. Overall, this work has enabled pushing the frontiers of molecular simulations to study rare events with a focus on nucleation in aqueous solutions.

36 MATERIALS SCIENCE↗

Exploration of Options for Ultra-Fast Mass Spectroscopy for Pulsed Power Applications

Mega-ampere class pulsed power machines drive intense currents into small volumes to study high energy and density environments. Power lost during these events is a difficult and paramount problem to solve. For example, facilities such as Sandia National Laboratories’ Z machine experience meaningful power loss, which can be linked to non-linear ohmic heating at high currents (i.e., 26 MA on Z) leading to thermal desorption of contaminants and subsequent shunt plasma formation. Characterizing and understanding this type of thermal desorption is key to design optimizations necessary to minimize current loss, which will be even more important for next generation pulsed power. This type of characterization requires the ability to identify and determine concentration of analytes with nanosecond resolution given the pulse width of Z is on the order of 100 ns. This report summarizes progress on a small exploratory project focused on investigating options to meet this challenge using mass spectrometry. The main focus of these efforts utilized an Energy and Velocity Analyzer for Distributions of Electric Rockets intending to determine how quickly transient data could be resolved. This probe combines an electrostatic analyzer with a Wien velocity filter (ExB) to obtain ion energy and velocity distributions. Primary results from this exploratory project indicate significant additional work is needed to demonstrate a nanosecond time scale mass spectrometer for this application and also highlight that alternative detection methods such as laser-based diagnostics should be considered to meet the need for ultra-fast detection.

42 ENGINEERING↗

2024 Milestone Report: Site 300 mPDV Optical Fiducials

In the early 2000s Photon Doppler Velocimetry (PDV) replaced the Fabry-Perot many beam system1 and has since become ubiquitous across dynamic experimental platforms to measure velocity and event times such as shock breakout, key variables for high pressure physics research. The advent of optically multiplexed oscilloscope channels to create multiplexed PDV (mPDV) increased portability and reduced price per data point. However, these advantages came with the cost of additional fielding complexity and thermally induced timing drift, which directly affects the ability to use PDV for high precision time measurement. Controlling the temperature or incorporating optical fiducials allows researchers to characterize, reduce, and correct this thermal drift in analysis. Our implemented optical fiducial or “timing marker” allows us to reduce thermal drift uncertainty from the 10s of nanoseconds down to the 100s of picoseconds with minimal added complexity to existing systems. The implementation of this timing marker normalizes uncertainty across optical delays, brings our facility cross timing into the sub nanosecond regime and lets us identify/study anomalies in our data. This improvement increases experiment reliability and quality enabling a new class of high precision experiments at S300.

42 ENGINEERING↗

Plasma-Bubble Imaging and Spectroscopy (Final Report)

The aim of this research was to capture time- and space-resolved behavior of breakdown initiation and development in water with gas bubbles injected between the electrodes when excited with microsecond voltage pulses. The results were directly compared to our previous results from a PCRF collaboration on the development of an electrical discharge in a gas bubble immersed in liquids with different conductivities when excited by nanosecond voltage pulses. For nanosecond regimes, cavitation seems to play a major role in plasma breakdown for low conductivities and discharge initiates at an electrode. On microsecond timescales, where cavitation does not play a role, it has been hypothesized that breakdown in water occurs first in bubbles on or near the electrodes, pre-existing or formed thermally.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation of longitudinal scraping of $H-$ bunches via photo-detachment

Longitudinal emittance growth is a significant challenge in RF linacs, especially for poorly bunched beams. This stems from particles occupying outer synchrotron oscillation orbits in the LBET, causing unwanted bunch-bunch interactions and degraded beam quality. To address this, we proposed using temporally spaced laser pulses to selectively photo-detach electrons from the longitudinal head and tail regions of H- ion bunches. This approach aims to reduce particle density in extreme orbits, enhancing beam uniformity and limiting emittance growth. Our experiments employed Fermilab's 'LaserNotcher' system at the font end of the linac, delivering 1.6 MW peak power with sub-nanosecond precision. By neutralizing the first and last half-nanosecond of several H- bunches, we measured their propagation injection into the booster. Measurements of pulse width, average height, and temporal spacing over booster cycles were compared between the scraped and unscraped bunches. Statistical analysis evaluated the results’ significance, highlighting the feasibility of laser-based scraping for future linac designs to achieve higher beam energies with improved emittance control.

Landon, P. [Boston U.; Fermilab]↗

Study of Protein Dynamics via Neutron Spin Echo Spectroscopy

Most human body proteins' activity and functionality are related to configurational changes of entire subdomains within the protein crystal structure. The crystal structures build the basis for any calculation that describes the structure or dynamics of a protein, most of the time with strong geometrical restrictions. However, these restrictions from the crystal structure are not present in the solution. The structure of the proteins in the solution may differ from the crystal due to rearrangements of loops or subdomains on the pico to nanosecond time scale (i.e., the internal protein dynamics time regime). This study describes how slow motions on timescales of several tens of nanoseconds can be accessed using neutron scattering. In particular, the dynamical characterization of two major human proteins, an intrinsically disordered protein that lacks a well-defined secondary structure and a classical antibody protein, is addressed by neutron spin echo spectroscopy (NSE) combined with a wide range of laboratory characterization methods. Further insights into protein domain dynamics were achieved using mathematical modeling to describe the experimental neutron data and determine the crossover between combined diffusive and internal protein motions. The extraction of the internal dynamic contribution to the intermediate scattering function obtained from NSE, including the timescale of the various movements, allows further vision into the mechanical properties of single proteins and the softness of proteins in their nearly natural environment in the crowded protein solution.

59 BASIC BIOLOGICAL SCIENCES↗

Pulse stretcher has improved dynamic range and linearity

Current-switching pulse stretcher overcomes the diode nonlinearity and capacitive feedthrough of voltage switching diode-capacitor stretchers and lengthens nanosecond pulses so that their amplitude may be determined and extends the dynamic range of the pulse stretcher. The rise time of the output pulse in response to a step function is approximately 5 nanoseconds.

Larsen, R. N.↗

Study of excitation transfer in a flowing helium afterglow pumped with a tuneable dye laser. 1: Measurement of the rate coefficient for selected quenching reactions involving he(5 3P)

A system is described for the measurement of excited state reaction times in the nanosecond range. A flowing afterglow produces large populations of chemically unstable species, and a pulsed, tuneable dye laser is used to selectively pump these into the reacting excited state. The transient fluorescence from the populations of reactants and end products is used to determine reaction lifetimes and yields. This radiatron is collected with a photon counting system which logs arrival times of spectrally dispersed photons with 10 nanosecond resolution.

Collins, C. B.↗

A three-electrode streamer chamber

A three electrode streamer chamber has been designed with basic components consisting of two glass boxes with overall dimensions 1.00 x 500 x 200 cu m filled with neon at 1 atm. Serving as a high voltage pulse source is a nanosecond voltage pulse generator with cutoff discharges at 16 atm nitrogen pressure. The discharges are designed for obtaining an adjustable pulse with an amplitude of 600 kV and a nanosecond pump. To match the chamber electrodes with the oscillator, the electrodes are manufactured in the shape of a three-wire strip line. The cutoff discharger plug-in and the operating instructions are also described here.

Nurgozhin, N. N.↗

Laser technology for high precision satellite tracking

Fixed and mobile laser ranging stations have been developed to track satellites equipped with retro-reflector arrays. These have operated consistently at data rates of once per second with range precision better than 50 cm, using Q-switched ruby lasers with pulse durations of 20 to 40 nanoseconds. Improvements are being incorporated to improve the precision to 10 cm, and to permit ranging to more distant satellites. These include improved reflector array designs, processing and analysis of the received reflection pulses, and use of sub-nanosecond pulse duration lasers.

Plotkin, H. H.↗

Remote profiling of lake ice using an S-band short-pulse radar aboard an all-terrain vehicle

A short-pulse (one nanosecond) S-band radar system was developed to supplement the information obtained with the aid of the SLAR system of the Great Lakes ice information system. It is the objective of the ice information system to aid in extending the winter navigation season. The SLAR imagery cannot be interpreted directly to obtain information concerning the thickness of the ice. This information is to be provided by a remote ice measuring system utilizing nanosecond radar pulses. A description is given of investigations in which such a system was installed on a C-47 aircraft. In other studies reported an S-band short-pulse radar was mounted on an all-terrain vehicle.

Cooper, D. W.↗

Gamma ray facilities at the University of Maryland cyclotron

A special beam line was set up in a separate shielded experimental room to provide a low background station for gamma-ray measurements at the University of Maryland cyclotron. The transmitted beam leaving the target is gathered in by a magnetic quadrupole lens located 1.8 m further downstream and focused on a Faraday cup located on the far side of the 2.5 m thick concrete shielding wall of the experimental room. A software computer program permits timing information ot be obtained using the cyclotron beam fine structure as a time reference for the observed gamma-ray events. Measurements indicate a beam fine structure width of less than 1.2 nanoseconds repeated, for example, in the case of 140 MeV alpha particles every 90 nanoseconds. Twelve contiguous time channels of adjustable width may be set as desired with reference to the RF signal. This allows the creation of 12 separate 8192 channel analyzers.

Hornyak, W. F.↗

VLBI clock synchronization

The potential accuracy of VLBI (very long baseline interferometry) for clock epoch and rate comparisons was demonstrated by results from long- and short-baseline experiments. It was found that atomic clocks at widely separated sites (several thousand kilometers apart) can be synchronized to within several nanoseconds from a few minutes of VLBI observations and to within one nanosecond from several hours of observations.

Counselman, C. C., III↗

Advanced spacecraft tracking techniques using the Tracking and Data Relay Satellite System /TDRSS/

The TDRSS will consist initially of two geosynchronous satellites and a common ground station at White Sands, New Mexico. According to current schedules, operations are to begin in November 1980. The overall TDRSS will provide high and low bit-rate telemetry, commands, and satellite-to-satellite tracking services. Each Tracking and Data Relay Satellite (TDRS) will have four antenna systems for NASA use. The common ground station at White Sands will have three 18-meter K-band antennas. The tracking equipment at the ground station is required to meet the following specifications: (1) 0.1-radian root-mean-square (rms) phase noise on nondestruct Doppler measurements; (2) 10-nanosecond rms range noise; (3) 50-nanosecond maximum systematic range error. Attention is given to two-way range and Doppler measurements, the bilateration tracking of TDRS, and an experiment using differenced one-way Doppler measurements.

Teles, J.↗