Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

Rapid deployment of residential photovoltaic (PV) systems helps decarbonize our electricity supplies, but under certain circumstances, high-penetration PV may pose challenges to the electrical distribution grid. In a project funded by the U.S. Department of Energy's Solar Energy Technologies Office and Building Technologies Office, the National Renewable Energy Laboratory and its partners studied how flexible building loads and battery storage, when coordinated at home-level and community-level scales, can be used to address those challenges and enhance grid resilience. In this webinar, we will discuss the methodology, simulation and field pilot results, insights from partners, and lessons learned from the project.

artificial intelligence↗

Characterizing Current THD’s Dependency on Solar Irradiance and Supraharmonics Profiling for a Grid-Tied Photovoltaic Power Plant

The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.

14 SOLAR ENERGY↗

Bifacial Vertical Testbed and Ground Irradiance Data in Golden, Colorado

This data was collected for Tonita et al., “Vertical bifacial photovoltaic system model validation: study with field data, various orientations, and latitudes,” for validation of optical models for vertically-oriented photovoltaics under high albedo. Ground irradiance data for vertical PV arrays modeling in agrivoltaics is also provided. The dataset is provided for further use or study as open source. For any questions on the dataset, email silvana.ovaitt@nlr.gov.

14 SOLAR ENERGY↗

From IEC 61853 power measurements to PV system simulations.

The IEC 61853 PV module energy rating standard requires measuring module power (and hence efficiency) over a matrix of irradiance and temperature conditions. These matrix points represent nearly the full range of operating conditions encountered in the field in all but the most extreme locations, and create an opportunity to develop alternative approaches to existing modelssuch as the single-diode models and the Sandia Array Performance Modelfor calculating system performance. This report begins by discussing the bilinear interpolation and extrapolation method from IEC 61853-3, and then describes four existing model-based methods that could be used with matrix measurements. Then a new model is developed and all options are compared according to seven objective criteria using the matrix measurements of four PV modules of different technologies. The results show that the new model is an excellent candidate for launching power matrix-based PV system simulations.

14 SOLAR ENERGY↗

DuraMAT: Building a Consortium to Accelerate the Photovoltaic Module Reliability Learning Cycle

Durable and reliable photovoltaic (PV) modules are critical to enabling an efficient transition to sustainable energy generation. The rate at which new module designs and materials are developed and deployed currently outpaces the rate at which we can identify failure mechanisms and understand degradation rates. Increasing the service life of PV modules, and our ability to predict performance over time, requires more durable materials and designs, better durability testing, more extensive material characterization, robust modeling, and methods to cross-examine historical performance data to extract meaningful results. This is a multidisciplinary challenge that requires expertise from a broad range of fields and, therefore, benefits significantly from a collaborative approach. In this Perspective, we outline the approach taken by the Durable Module Materials Consortium (DuraMAT), present a few case studies where our approach was successful, and provide an outlook on where this approach might be applied as the PV technology landscape continues to rapidly evolve. Published by the American Physical Society 2024

14 SOLAR ENERGY↗

Thermally Conductive Backsheets (TCB) of PV Modules: Positive Impacts on Performance, Lifetime and LCOE

The operating temperatures of photovoltaic (PV) modules can be impacted by the selection of specific packaging materials, e.g., backsheets and encapsulants. This research focuses on the evaluation of operating temperature reduction of one-cell modules by comparing conventional Tedlar/polyester/Tedlar (TPT) backsheet with novel thermally conductive backsheets (TCBs) materials. A large number of one-cell modules with two TCB types (TCB_A and TCB_B) and baseline TPT type were fabricated and installed in three different climatic conditions of the hot-dry desert in Arizona (high and low wind speed locations) and North Carolina (temperate with low wind speed location). In this study, these two TCBs were compared with conventional TPT backsheet in terms of performance, lifetime and levelized cost of energy (LCOE). The field results were analyzed for thermal performance of TCBs compared to TPT at three sites for two and half years. This study concludes that the thermal and electrical performances of the PV modules can be improved by using TCB_A in hot and dry climate sites and TCB_B at temperate climate sites. Therefore, the lifetime of TCB-based modules is expected to be higher than TPT-based modules. Using backsheet-specific power degradation levels and assuming the same cost for both types of backsheets, the LCOE of modules using TCBs is estimated to be lower than that of TPT.

14 SOLAR ENERGY↗

Viewing convection as a solar farm phenomenon broadens modern power predictions for solar photovoltaics

We report heat mitigation for large-scale solar photovoltaic (PV) arrays is crucial to extend lifetime and energy harvesting capacity. PV module temperature is dependent on site-specific farm geometry, yet common predictions consider panel-scale and environmental factors only. Here, we characterize convective cooling in diverse PV array designs, capturing combined effects of spatial and atmospheric variation on panel temperature and production. Parameters, including row spacing, panel inclination, module height, and wind velocity, are explored through wind tunnel experiments, high-resolution numerical simulations, and operating field data. A length scale based on fractal lacunarity encapsulates all aspects of arrangement (angle, height, etc.) in a single value. When applied to the Reynolds number Re within the canonical Nusselt number heat transfer correlation, lacunarity reveals a relationship between convection and farm-specific geometry. This correlation can be applied to existing and forthcoming array designs to optimize convective cooling, ultimately increasing production and PV cell life.

14 SOLAR ENERGY↗

Using Artificial Soiling to Rank Anti-Soiling Coatings for Arid Climates

A simple method to evaluate (e.g., screen and rank) the performance of coatings that are fully or partially anti-soiling (AS) is lacking within the PV industry. Artificial soiling may be used as a rapid and economical assessment approach, offering an efficient alternative to time-intensive, site-specific field testing. In this study, we present an artificial soiling method to replicate the anti-soiling performance rankings of two groups of coated glass samples supplied by two manufacturers (group C with CA, CP, and CS coatings; group A with AC coating). These are compared to field aging in two climates: semi-arid Lemoore, California over 4 months, and the hot desert in Mesa, Arizona over 7 months. Both field and indoor performance ranking utilize the transmittance ratio, defined as the optical transmittance between a coated sample and an uncoated reference in each group, as an evaluation metric to assess the effectiveness of the artificial soiling approach in replicating field soiling. It is critical to mimic the dominant field meteorological conditions associated with soiling-prone days and vulnerable times of day during the soiling season. Our results reveal that the use of artificial soiling for field performance ranking among coatings strongly depends on the soil type (composition and particle distribution), dust surface density, and prevalent environmental factors (wetting saturation by humidity, dew condensation extent, and prior weathering history of the coating). The similar rank order relative to the field suggests that the artificial soiling approach presented may be used for down-selecting anti-soiling coatings prior to prolonged field validation.

14 SOLAR ENERGY↗

Determining blood and plasma volumes using bioelectrical response spectroscopy

We hypothesized that an electric field (inductance) produced by charged blood components passing through the many branches of arteries and veins could assess total blood volume (TBV) or plasma volume (PV). Individual (N = 29) electrical circuits (inductors, two resistors, and a capacitor) were determined from bioelectrical response spectroscopy (BERS) using a Hewlett Packard 4284A Precision LCR Meter. Inductance, capacitance, and resistance from the circuits of 19 subjects modeled TBV (sum of PV and computed red cell volume) and PV (based on 125I-albumin). Each model (N = 10, cross validation group) had good validity based on 1) mean differences (-2.3 to 1.5%) between the methods that were not significant and less than the propagated errors (+/- 5.2% for TBV and PV), 2) high correlations (r > 0.92) with low SEE (< 7.7%) between dilution and BERS assessments, and 3) Bland-Altman pairwise comparisons that indicated "clinical equivalency" between the methods. Given the limitation of this study (10 validity subjects), we concluded that BERS models accurately assessed TBV and PV. Further evaluations of the models' validities are needed before they are used in clinical or research settings.

NASA Discipline Number 00-00↗

Optimizing Bifacial PV Systems (Q3 FY2020 Project Report)

This project has four main technical objectives. Develop and improve bifacial performance models by adding the capability to evaluate electrical behavior and performance of bifacial modules and arrays under realistic field conditions including irradiance variability caused by racking, module frame, and position in the array. Instrument and monitor performance of fielded bifacial systems to validate performance models and to measure, analyze and publish on bifacial energy gain. These should include both research and commercial bifacial systems and cover a variety of deployment applications. Evaluate optimal bifacial system designs using simulations leveraging high performance computing, and also using full sized and miniaturized experimental field deployments. Establish and contribute to international test standards for bifacial system performance, testing, and safety, and work with the community to establish installation and siting best practices.

14 SOLAR ENERGY↗

PV Inverter Systems Enabled by Monolithically Integrated SiC based Four Quadrant Power Switch (4-QPS) [BiDFET]

The purpose of this project was to develop a new breed of Power Conversion Systems (PCS) for PV integration that is enabled by the newly developed 4-Quadrant Single Die SiC Power Semiconductor Switches (4-QPS) or also referred to as “Bidirectional FET (BIDFET)”. This work includes semiconductor die development, advanced packaging, converter design, development, and testing of 4-QPS enabled hardware prototypes at 1 kW (for single phase residential application) and 10 kW (for three phase commercial application). The BiDirectional Field-Effect Transistor (BiDFET) can enable circuit topologies requiring four-quadrant switches, that were earlier designed using discrete combinations of MOSFETs, IGBTs, GaN HEMTs, and PiN diodes. The monolithic nature of the BiDFET allows lower device count, smaller switch volume, lower inductance, and simpler packaging, and hence more reliable and commercially viable implementation in power electronics converters. The matrix converter topologies, now feasible using BiDFETs, can eliminate the bulky and unreliable dc link capacitors or inductors required for conventional voltage-source or current-source converters in ac–ac and ac–dc applications. The 1.2 kV BiDFET has the potential to disrupt all the applications utilizing 1.2 kV switches, including electric vehicle (EV) drivetrain, bidirectional EV chargers, industrial motor drives, solid-state transformers, datacenter power supplies, elevator drives, dc microgrids, energy storage grid integration, solid-state breakers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Airborne DIAL Ozone and Aerosol Trends Observed at High Latitudes Over North America from February to May 2000

Ozone (O3) and aerosol scattering ratio profiles were obtained from airborne lidar measurements on thirty-eight aircraft flights over seven aircraft deployments covering the latitudes of 40 deg.-85 deg.N between 4 February and 23 May 2000 as part of the TOPSE (Tropospheric Ozone Production about the Spring Equinox) field experiment. The remote and in situ O3 measurements were used together to produce a vertically-continuous O3 profile from near the surface to above the tropopause. Ozone, aerosol, and potential vorticity (PV) distributions were used together to identify the presence of pollution plumes and stratospheric intrusions. The number of observed pollution plumes was found to increase into the spring along with a significant increase in aerosol loading. Ozone was found to increase in the middle free troposphere (4-6 km) at high latitudes (60 deg.-85 deg. N) by an average of 4.3 ppbv/mo from about 55 ppbv in early February to over 72 ppbv in mid-May. The average aerosol scattering ratios in the same region increased at an average rate of 0.37/mo from about 0.35 to over 1.7. Ozone and aerosol scattering were highly correlated over entire field experiment. Based on the above results and the observed aircraft in-situ measurements, it was estimated that stratospherically-derived O3 accounted for less than 20% of the observed increase in mid tropospheric O3 at high latitudes. The primary cause of the observed O3 increase was found to be the photochemical production of O3 in pollution plumes.

Hair, Jonathan W.↗

Wind Conditions for Solar Energy Facility Design Based on Field Measurements at Nevada Solar One

This study characterises near-surface wind conditions at the Nevada Solar One (NSO) concentrated solar power plant using two years of measurements from a 15-m mast located 30 m west of the solar arrays. The surrounding terrain is fairly flat within 3 km, but nearby solar photovoltaic (PV) and concentrated solar power (CSP) installations introduce strong directional wind inhomogeneity, which motivates a sector-based analysis that distinguishes undisturbed inflow from waked flow. The analysis uses data from three sonic anemometers to assess whether turbulence in the surface layer can be represented as Gaussian and whether standard surface-layer scaling remains valid below 10 m height. The roughness length and displacement height are estimated for twelve directional sectors under near-neutral wind conditions, and all three velocity components show departures from Gaussian behaviour. Spectral analysis indicates that the turbulence contains low-frequency fluctuations with amplitudes higher than those predicted by standard models such as the Kaimal model or the Simiu and Scanlan model. The study introduces a new turbulence spectral model based on the eddy-surface-layer framework to better represent near-surface wind turbulence. The analysis further quantifies the influence of the surrounding power plants on mean wind profiles, one-point spectra, and vertical coherence for all velocity components. The solar collector arrays located 30 m east of the mast significantly modify the turbulence structure, whereas PV installations situated a few hundred metres away have only a limited influence on the turbulence measured at the mast. These findings highlight the limitations of conventional turbulence models for near-surface wind over solar infrastructure and provide improved parameterisations to support the structural design. The implications for the structural response of parabolic troughs and PV modules to such turbulence remain uncertain and require further investigation.

14 SOLAR ENERGY↗

2021 Q1 Project Report: Optimized Bifacial PV Systems (Q1 FY2021 Project Report)

This project has four main technical objectives: 1) Develop and improve bifacial performance models by adding the capability to evaluate electrical behavior and performance of bifacial modules and arrays under realistic field conditions including irradiance variability caused by racking, module frame, and position in the array. 2) Instrument and monitor performance of fielded bifacial systems to validate performance models and to measure, analyze and publish on bifacial energy gain. These should include both research and commercial bifacial systems and cover a variety of deployment applications. 3) Evaluate optimal bifacial system designs using simulations leveraging high-performance computing, and also using full sized and miniaturized experimental field deployments. 4) Establish and contribute to international test standards for bifacial system performance, testing, and safety, and work with the community to establish installation and siting best practices.

42 ENGINEERING↗

Predicting electrochemical breakdown in terrestrial photovoltaic modules

Electrochemical corrosion of PV cells can cause a cell-to-frame short circuit with two undesirable resuits: (1) catastrophic loss of source-circuit power; and (2) high field maintenance (module replacement) costs. Parameter dependencies are determined and encapsulated two-cell coupons are exposed to a range of voltage differences, temperatures, and relative humidities. Material relative performance is assessed. Nine different metallization-encapsulation combinations are tested.

Mon, G. R.↗

Transient Data Library of Solar Grid Integrated Distributed System

This submission contains an open-source library of transient events in distributed system with high solar PV. The library includes the collected data, related documents and scripts for loading the data. The data library is built for transient event detection and machine learning based analysis algorithm development. The data was collected via both field test and software simulation. The units for the data are included in the data file headers for each data series. A text editor or spreadsheet software, such as Excel, and Matlab is required to view the data.

algorithms↗

A Data Quality-Aware Framework to Reliably Forecast Photovoltaic Generation and Consumer Load for an Improved Resilience of Microgrids

Photovoltaic (PV) power and consumer load forecasting plays a critical role to ensure operational resilience of the electric grid. Most data-driven forecasting algorithms rely heavily on the continuous availability of good quality data for periodic training and validation. When deployed at the grid’s edge, prolonged disruptions to communications during extreme events degrade data quality. Factors such as missing observations, epistemic uncertainties, data drift, and concept drift are manifestations of data quality that impact the generalization of such field-deployed forecasting models. Currently, there exists no mechanism in the literature to dynamically switch between models under varying degrees of data quality as quantified by certain metrics for each factor highlighted above. This paper addresses this shortcoming by conceptually introducing a data qualityaware framework for reliable PV generation and consumer load forecasting. The framework’s design incorporates components of missing values, divergence tests, and continuous monitoring of generalization performance to detect changes in data quality caused by communications disruptions and trigger specific classes of forecasting models grouped under three use cases (UC1- UC3). As a first step towards validating this framework, real data collected from an actual field microgrid system is used to demonstrate the viability of the three use cases. Results show that the performance is the best in UC1 with an unadjusted R-square value of 0.954, followed by 0.939 for UC2 and 0.757 for UC3.

Sundararajan, Aditya↗

Predictive Models and Novel Accelerated Tests for the Reliability of Cell Metallization in Photovoltaic Modules (Final Report)

Studies of metallization corrosion m photovoltaics have mainly been limited to comparisons of modules placed in accelerated chambers to fielded modules [1]. Damp Heat accelerated tests and phenomenological equations [2] are used to assess metallization corrosion without understanding the effect of UV light and temperature and humidity cycles on encapsulant adhesion degradation. The roles of encapsulant in-and out-diffusions of moisture and encapsulant impurities are important. Furthermore, few photovoltaic metallization corrosion studies included the role of bias and leakage currents, which are crucial in the electrochemical reaction of metallization. Leakage currents can highly accelerate the corrosion mechanism and are important to include in the studies of corrosion. In our research plan, we will address the following gaps in the PV community's understanding of metallization corrosion: (1) metallization corrosion with bias, humidity, and impurities in the encapsulant or metallization; (2) humidity diffusion through fresh and degraded encapsulants; and (3) comparison of model predictions with outdoor field modules and SunPower's extensive data for its back-contact and front-contact fleets [2] along with NREL's store of >20 year old modules. Our goal is to build models and accelerated tests to predict long term degradation of metallization corrosion of photovoltaic modules in the field. Our studies will include metals used in c-Si solar cells (Cu, Ag, and Al) and commonly used encapsulants (EV A (ethylene vinyl acetate), TPO (thermoplastic olefin), and silicone).

14 SOLAR ENERGY↗