Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reservoir operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Progress of Gas Injection EOR Surveillance in the Bakken Unconventional Play—Technical Review and Machine Learning Study

Although considerable laboratory and modeling activities were performed to investigate the enhanced oil recovery (EOR) mechanisms and potential in unconventional reservoirs, only limited research has been reported to investigate actual EOR implementations and their surveillance in fields. Eleven EOR pilot tests that used CO2, rich gas, surfactant, water, etc., have been conducted in the Bakken unconventional play since 2008. Gas injection was involved in eight of these pilots with huff ‘n’ puff, flooding, and injectivity operations. Surveillance data, including daily production/injection rates, bottomhole injection pressure, gas composition, well logs, and tracer testing, were collected from these tests to generate time-series plots or analytics that can inform operators of downhole conditions. A technical review showed that pressure buildup, conformance issues, and timely gas breakthrough detection were some of the main challenges because of the interconnected fractures between injection and offset wells. The latest operation of co-injecting gas, water, and surfactant through the same injection well showed that these challenges could be mitigated by careful EOR design and continuous reservoir monitoring. Reservoir simulation and machine learning were then conducted for operators to rapidly predict EOR performance and take control actions to improve EOR outcomes in unconventional reservoirs.

Energy & Fuels↗

Thermocatalytic Heat Pipes for Geothermal Resource Recovery

Heat pipes are an important technology that allow orders of magnitude faster heat transfer than simple conduction. However, operating principles in heat pipes place fundamental bounds on their performance (critical heat flux and efficiency). Conventional heat pipe functionality is inherently tied to vaporization and condensation of the working fluid charged in the heat pipe. These fluids each have different operating temperature ranges based on the capillary, entrainment, sonic, and boiling limits of the heat pipe design. These limits, typically the capillary limit, dictate the maximum heat flux a heat pipe can carry, and most importantly for geothermal systems, the distance over which the pipes can operate (100 to 200 m maximum under optimum conditions). A thermocatalytic heat pipe breaks the inherent limitations of phase change thermo- and hydrodynamics and can transform heat pipe technology as a potentially more efficient means of extracting heat from a geothermal resource. The thermocatalytic heat pipe uses a working fluid to transport both sensible and chemical heat. An endothermic chemical reaction at depth removes heat from the reservoir and produces reactive intermediates, which are transported to the surface and used to run a reverse exothermic reaction that releases heat for use in power generation or other useful purposes. This technology offers two distinct advantages over conventional geothermal heat recovery technologies: (1) lower heat loss to the rock outside of the geothermal reservoir, and (2) higher heat transfer rates to the well field within the geothermal reservoir. Both advantages offer opportunity to reduce risks and lower costs of geothermal energy recovery. In this report, we discuss an initial effort to assess the efficacy and limitations of this technology for extracting heat from both porous/permeable and nominally impermeable geothermal reservoirs. Numerical simulation capabilities of the STOMP-GT code were enhanced to enable simulations of thermochemical heat pipes traversing geothermal reservoirs. An array of potential thermochemical reaction systems was evaluated and screened. Of these, an ethanol dehydration reaction was most promising in the vapor-liquid reaction set. A solid-phase dehydration reaction (CuSO4·5H2O) showed the highest reaction enthalpy per unit volume but would require development of a nonaqueous carrier fluid to implement it in a heat pipe. Subsurface reservoir simulations predicted long-term performance of the heat pipes for each geothermal reservoir type. The performance of U-shaped wells and coaxial wells was evaluated for a suite of reactions for both hydrothermal and hot dry rock reservoirs and was compared with a baseline case of simply pumping water through the wells. The heat pipe technology was additionally evaluated for an enhanced geothermal system (EGS) with an injection borehole, production borehole, and intervening hydraulically conductive fracture. All reservoir types showed significant improvement in heat recovered over a 20-year operating period ranging from a 1.8X increase for the hot dry rock case to more than 2.5X more energy recovered for the EGS case.

15 GEOTHERMAL ENERGY↗

Hybrid Uses of High-Temperature Reservoir Thermal Energy Storage: Lessons Learned from Previous Projects

One of the critical challenges of the green energy transition is resolving the mismatch between energy generation provided by intermittent renewable energy sources such as solar and wind and the demand for energy. There is a need for large amounts of energy storage over a range of time scales (diurnal to seasonal) to better balance energy supply and demand. Subsurface geologic reservoirs provide the potential for storage of hot water that can be retrieved when needed and used for power generation or direct-use applications, such as district heating. It is important to identify potential issues associated with high-temperature reservoir thermal energy storage (HT-RTES) systems so that they can be mitigated, thus reducing the risks of these systems. This paper reviews past experiences from moderate and high-temperature reservoir thermal energy storage (RTES) projects, along with hot water and steam flood enhanced oil recovery (EOR) operations, to identify technical challenges encountered and evaluate possible ways to address them. Some of the identified technical problems that have impacted system performance include: 1) insufficient site characterization that failed to identify reservoir heterogeneity; 2) scaling resulting from precipitation of minerals having retrograde solubility that form with heating of formation brines; 3) corrosion from low pH or high salinity brines; 4) thermal breakthrough between hot and cold wells due to insufficient spacing. Proper design, characterization, construction, and operational practices can help reduce the risk of technical problems that could lead to reduced performance of these thermal energy storage systems.

energy storage↗

Reactive Transport Modeling of Anthropogenic Carbon Mineralization in Stacked Columbia River Basalt Reservoirs

Numerical simulation of CO2 storage in basalts and related reactive lithologies requires modeling complex, coupled hydrologic and chemical processes, including multi-phase flow and transport, partitioning of CO2 into the aqueous phase, and chemical interactions with aqueous fluids and rock minerals. We conducted reactive transport simulations of the Wallula pilot-scale CO2 injection into the flow tops of the Grande Ronde Basalt using our PNNL STOMP-CO2 simulator with the ECKEChem reactive module. Our mineralization simulation of the ~1,000 tons of injected CO2 into the interflow zones was based on the hydrologic transport model we previously developed. For this work, the simulations considered geochemical reactions involving the basalt components, precipitates, formation brine, and injected CO2. In our benchmark case, carbonate minerals precipitated, resulting in ~20% of the CO2 being mineralized in 10 years. Increasing the reaction rate of a single primary mineral phase (clinopyroxene) by an order of magnitude resulted in a carbon mineralization reaction extent of ~90% over the same time interval. Based on these initial sensitivity analysis results, it is clear that a thorough understanding of primary mineral dissolution rates is required for accurately predicting long-term fate and transport of injected CO2 into basalt formations. Our reactive transport numerical simulations will be key components of commercial-scale CO2 storage operation permitting, de-risking, and optimization in mafic and ultramafic reservoirs.

Cao, Ruoshi↗

International Space Station United States Orbital Segment Oxygen Generation System On-Orbit Operational Experience

The International Space Station (ISS) United States Orbital Segment (USOS) Oxygen Generation System (OGS) was originally intended to be installed in ISS Node 3. The OGS rack delivery was accelerated, and it was launched to ISS in July of 2006 and installed in the US Laboratory Module. Various modification kits were installed to provide its interfaces, and the OGS was first activated in July of 2007 for 15 hours, In October of 2007 it was again activated for 76 hours with varied production rates and day/night cycling. Operational time in each instance was limited by the quantity of feedwater in a Payload Water Reservoir (PWR) bag. Feedwater will be provided by PWR bag until the USOS Water Recovery System (WRS) is delivered to SS in fall of 2008. This paper will discuss operating experience and characteristics of the OGS, as well as operational issues and their resolution.

Erickson, Robert J.↗

Pressure Barrier Applicability to Polymer Flood Design

Effective oil displacement from a reservoir requires adequate and properly directed pressure gradients in areas of high oil saturation. If the polymer bank is too large or too viscous during a polymer flood, the pressure drop from the injection well to the polymer front may act as a pressure barrier by usurping most of the downstream driving force for oil displacement. Polymer injection pressures must be limited. The maximum allowable injection pressure is commonly constrained by caprock integrity, injection equipment, and/or regulations, even though fractures can be beneficial to polymer injectivity (and even sweep efficiency in some cases). This paper examines when the pressure-barrier concept limits the size and viscosity of the polymer bank during a polymer flood. Both analytical and numerical methods are used to address this issue. We examine the relevance of the pressure barrier concept for a wide variety of circumstances, including oil viscosities ranging from 10-cp (like at Daqing, China) to 1650-cp (like at Pelican Lake, Alberta), vertical wells (like at Tambaredjo, Suriname) versus horizontal wells (like at Milne Point, Alaska), single versus multiple layered reservoirs, permeability contrast, and with versus with crossflow between layers. We also examine the relation between the pressure-barrier concept and fractures and fracture extension during polymer injection. We demonstrate that in reservoirs with single layers, the pressure-barrier concept only limits the optimum viscosity of the injected polymer if the mobility of the polymer bank is less than the mobility of the displaced oil bank. The same is true for multi-zoned reservoirs with no crossflow between layers. Thus, for these cases, the optimum polymer viscosity is likely to be dictated by the mobility of the oil bank, unless other factors (like fracture extension) intervene. For multi-zoned reservoirs with free crossflow between layers, the situation is different. A compromise must be reached between injected polymer viscosity and the efficiency of oil recovery. The relevance of our findings is applied to operations for several existing polymer floods. This work is particularly relevant to viscous-oil reservoirs (like Pelican Lake and others) where the injected polymer viscosities are substantially lower than the oil viscosity

Wang, Dongmei↗

Environmental parameters of the Tennessee River in Alabama. 2: Physical, chemical, and biological parameters

Physical, chemical and biological water quality data from five sites in the Tennessee River, two in Guntersville Reservoir and three in Wheeler Reservoir were correlated with climatological data for three annual cycles. Two of the annual cycles are for the years prior to the Browns Ferry Nuclear Power Plant operations and one is for the first 14 months of Plant operations. A comparison of the results of the annual cycles indicates that two distinct physical conditions in the reservoirs occur, one during the warm months when the reservoirs are at capacity and one during the colder winter months when the reservoirs have been drawn-down for water storage during the rainy months and for weed control. The wide variations of physical and chemical parameters to which the biological organisms are subjected on an annual basis control the biological organisms and their population levels. A comparison of the parameters of the site below the Power plant indicates that the heated effluent from the plant operating with two of the three reactors has not had any effect on the organisms at this site. Recommendations given include the development of prediction mathematical models (statistical analysis) for the physical and chemical parameters under specific climatological conditions which affect biological organisms. Tabulated data of chemical analysis of water and organism populations studied is given.

Rosing, L. M.↗

Enhancing Multi-Step Reservoir Inflow Forecasting: A Time-Variant Encoder–Decoder Approach

Accurate reservoir inflow forecasting is vital for effective water resource management. Reliable forecasts enable operators to optimize storage and release strategies to meet competing sectoral demands—such as water supply, irrigation, and hydropower scheduling—while also mitigating flood and drought risks. To address this need, in this study, we propose a novel time-variant encoder–decoder (ED) model designed specifically to improve multi-step reservoir inflow forecasting, enabling accurate predictions of reservoir inflows up to seven days ahead. Unlike conventional ED-LSTM and recursive ED-LSTM models, which use fixed encoder parameters or recursively propagate predictions, our model incorporates an adaptive encoder structure that dynamically adjusts to evolving conditions at each forecast horizon. Additionally, we introduce the Expected Baseline Integrated Gradients (EB-IGs) method for variable importance analysis, enhancing interpretability of inflow by incorporating multiple baselines to capture a broader range of hydrometeorological conditions. The proposed methods are demonstrated at several diverse reservoirs across the United States. Our results show that they outperform traditional methods, particularly at longer lead times, while also offering insights into the key drivers of inflow forecasting. These advancements contribute to enhanced reservoir management through improved forecasting accuracy and practical decision-making insights under complex hydroclimatic conditions.

58 GEOSCIENCES↗

Thin liquid film as an optical nonlinear-nonlocal medium and memory element in integrated optofluidic reservoir computer

Understanding light–matter interaction lies at the core of our ability to harness physical effects and to translate them into new capabilities realized in modern integrated photonics platforms. Here, we present the design and characterization of optofluidic components in an integrated photonics platform and computationally predict a series of physical effects that rely on thermocapillary-driven interaction between waveguide modes and topography changes of optically thin liquid dielectric film. Our results indicate that this coupling introduces substantial self-induced phase change and transmittance change in a single channel waveguide, transmittance through the Bragg grating waveguide, and nonlocal interaction between adjacent waveguides. We then employ the self-induced effects together with the inherent built-in finite relaxation time of the liquid film, to demonstrate that the light-driven deformation can serve as a reservoir computer capable of performing digital and analog tasks, where the gas–liquid interface operates both as a nonlinear actuator and as an optical memory element.

42 ENGINEERING↗

Development and Testing of a Variable Conductance Thermal Acquisition, Transport, and Switching System

This paper describes the development and testing of a scalable thermal control architecture for instruments, subsystems, or systems that must operate in severe space environments with wide variations in sink temperature. The architecture is comprised by linking one or more hot-side variable conductance heat pipes (VCHPs) in series with one or more cold-side loop heat pipes (LHPs). The VCHPs provide wide area heat acquisition, limited distance thermal transport, modest against gravity pumping, concentrated LHP startup heating, and high switching ratio variable conductance operation. The LHPs provide localized heat acquisition, long distance thermal transport, significant against gravity pumping, and high switching ratio variable conductance operation. Combining two variable conductance devices in series ensures very high switching ratio isolation from severe environments like the Earth's moon, where each lunar day spans 15 Earth days (270 K sink, with a surface-shielded/space viewing radiator) and each lunar night spans 15 Earth days (80-100 K radiative sink, depending on location). The single VCHP-single LHP system described herein was developed to maintain thermal control of International Lunar Network (ILN) anchor node lander electronics, but it is also applicable to other variable heat rejection space missions in severe environments. The LHPVCHP system utilizes a stainless steel wire mesh wick ammonia VCHP, a Teflon wick propylene LHP, a pair of one-third square meter high  radiators (one capillary-pumped horizontal radiator and a second gravity-fed vertical radiator), a half-meter of transport distance, and a wick-bearing co-located flow regulator (CLFR) to allow operation with a hot (deactivated) radiator. The VCHP was designed with a small reservoir formed by extending the length of its stainless steel heat pipe tubing. The system was able to provide end-to-end switching ratios of 300-500 during thermal vacuum testing at ATK, including 3-5 W/K ON conductance and 0.01 W/K OFF conductance. The test results described herein also include an in-depth analysis of VCHP condenser performance to explain VCHP switching operation in detail. Future multi-VCHP/multi-LHP thermal management system concepts that provide scalability to higher powers/longer transport lengths are also discussed in the paper.

Bugby, D. C.↗

Optimization-based modeling and economic comparison of membrane distillation configurations for application in shale gas produced water treatment

Membrane distillation (MD) is an emerging membrane technology with great potential for treatment of hypersaline wastewater generated by unconventional (shale) oil and gas reservoirs. However, the low energy efficiency of this technology makes the operating cost of MD systems relatively high, especially in the absence of waste heat. There are several MD configurations with inherent advantages and disadvantages and varying performance. As such, there is a need for thermo-economic optimization of MD systems in a systematic manner to assess their economic performance. Here we present an optimization framework to model and compare the performance of six MD configurations (DCMD, AGMD, PGMD, CGMD, SGMD, and VMD) in continuous recirculation mode for treatment of hypersaline wastewater. The optimization results show that AGMD with small gap size operated at low stream Reynolds number outperforms all other configurations with treatment cost of 4.57 US $/m 3 of feed. However, restricting the system design to more practically relevant operating conditions, such as higher Reynolds number and larger gap size, diminishes the cost superiority of AGMD over other configurations. We also observed that treatment cost using PGMD configuration approaches those of CGMD and DCMD, particularly when modules with small gaps are used.

42 ENGINEERING↗

Deep-learning-enhanced assessment of wellbore barrier effectiveness in geologic storage systems with intermediate aquifers

For geologic systems where carbon dioxide (CO 2 ) is injected underground, existing wells represent potential pathways for fluid migration. Here, this study introduces a novel deep learning model to quantify the likelihood and potential magnitude of fluid migration through wellbores at sites with intermediate aquifers or thief zones between the injection units and underground drinking water sources. Synthetic datasets, generated using reservoir simulations, captured a wide range of subsurface conditions, well attributes, operational parameters, and fluid migration scenarios. Among the regression models developed to predict brine and CO 2 leakage rates and CO 2 saturations along leaky wellbores, convolutional neural network (CNN) outperformed both Light Gradient Boosting Machine and deep neural network. Additionally, a CNN-based classification model was created to predict whether brine and CO 2 would leak along a wellbore, further improving performance over regression alone. The best models were integrated into the National Risk Assessment Partnership Open-source Integrated Assessment Model for rapid, stochastic assessment of storage system containment and leakage risks. A case study demonstrated the model’s ability to simulate fluid migration through existing wells with multiple intermediate aquifers. This computationally efficient wellbore model offers value in support of site performance evaluation and risk-informed decision making by stakeholders.

CO2 leakage↗

Impacts of Small-Scale Heterogeneity on Large-Scale Subsurface Flow

Discussion of NETL's CT scanning and core characterization capabilities, followed by a rapid review of several recent publications that utilize these capabilities to answer reservoir questions at the micro scale with relevance to field scale operations.

core characterization↗

Electrodes for the thermionic converters, phase 2 - 3

The characteristics of electrodes for thermionic converters are discussed. A metal/ceramic Marchuk tube was constructed and operated with a quiescent cesium vapor plasma corresponding to cesium liquid reservoir temperatures from 376 to 427 K. The work function characteristics of tantalum test emitters coated with anodic films were measured to evaluate the applicability of the materials as the collector surface in a plasma mode thermionic converter. Work function minimum values between 1.4 and 1.5 electron volts were observed. The effect of the electronegative surface layers was partially obscured by additive vapor impurities detected by the clean tantalum reference emitter.

Desteese, J. G.↗

Results from the cascaded variable conductance heatpipe experiment on LDEF

A Variable Conductance Heat Pipe Experiment (CVCHPE) was successfully flown onboard the LDEF and demonstrated temperature control better than +/- 0.3 C during 50 days of on-orbit data collection in a widely varying external environment. The experiment used two series connected, dry reservoir variable conductance heat pipes which require no electrical power for operation. The heat pipes used a central artery design with ammonia working fluid and nitrogen control gas.

Grote, Michael G.↗

Results from the LDEF/A0076 cascaded variable conductance heatpipe experiment

The A0076 Variable Conductance Heat Pipe Experiment (CVCHPE) on the Long Duration Exposure Facility (LDEF) demonstrated temperature control better than +/- 0.3 C during fifty days on on-orbit data collection in a widely varying external environment. The experiment used two series connected, dry reservoir variable conductance heat pipes which require no electrical power for operation. The heat pipes used a central artery design with ammonia working fluid and nitrogen control gas. The LDEF was in orbit for almost six years rather than the planned one year mission. Although no additional data were taken during this extended period, post-test data indicated that the set point drifted upward less than 1 C per year. There were significant changes to the appearance of all external thermal control surfaces primarily due to atomic oxygen degradation, and one small anomaly in the electronics. These changes, though, had little effect on the CVCHPE performance.

Grote, Michael G.↗

Cryogenic shutter

A magnetically operated shutter mechanism is provided that will function in cryogenic or cryogenic zero gravity environments to selectively block radiation such as light from passing through a window to a target object such as a mirror or detector located inside a cryogenic container such as a dewar. The mechanism includes a shutter paddle blade that is moved by an electromagnetically actuated torquing device between an open position where the target object is exposed to ambient radiation or light and a closed position where the shutter paddle blade shields the ambient radiation or light from the target object. The purpose of the shuttering device is to prevent the mirror or other target object from being directly exposed to radiation passing through the window located on the side wall of the dewar, thereby decreasing or eliminating any temperature gradient that would occur within the target object due to exposure to the radiation. A special nylon bearing system is utilized to prevent the device from binding during operation and the paddle blade is also thermally connected to a reservoir containing cryogen to further reduce the internal temperature.

Barney, Richard D.↗

Cryogenic shutter

A magnetically operated shutter mechanism is provided that will function in cryogenic or cryogenic zero gravity environments to selectively block radiation such as light from passing through a window to a target object such as a mirror or detector located inside a cryogenic container such as a dewar. The mechanism includes a shutter paddle blade that is moved by an electromagnetically actuated torquing device between an open position where the target object is exposed to ambient radiation or light and a closed position where the shutter paddle blade shields the ambient radiation or light from the target object. The purpose of the shuttering device is to prevent the mirror or other target object from being directly exposed to radiation passing through the window located on the side wall of the dewar, thereby decreasing or eliminating any temperature gradient that would occur within the target object due to exposure to the radiation. A special nylon bearing system is utilized to prevent the device from binding during operation and the paddle blade is also termally connected to a reservoir containing the cryogen to further reduce the internal temperature.

Barney, Richard D.↗