Search NASASearch

SEARCH · Search NASA

Results for “Room Temperature Ionic Liquids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

479 records · Page 16

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Method and apparatus for providing thermal wear leveling

Exemplary embodiments provide thermal wear spreading among a plurality of thermal die regions in an integrated circuit or among dies by using die region wear-out data that represents a cumulative amount of time each of a number of thermal die regions in one or more dies has spent at a particular temperature level. In one example, die region wear-out data is stored in persistent memory and is accrued over a life of each respective thermal region so that a long term monitoring of temperature levels in the various die regions is used to spread thermal wear among the thermal die regions. In one example, spreading thermal wear is done by controlling task execution such as thread execution among one or more processing cores, dies and/or data access operations for a memory.

Roberts, David A.

Iron surface corrosion in supercritical CO2 at atomic scale investigated by molecular dynamics simulations

Understanding the corrosion behavior of steels in supercritical carbon dioxide (S-CO2) is essential for ensuring the safe application of S-CO2 as a heat-transfer fluid in high-temperature energy systems, including advanced nuclear reactors. In this work, molecular dynamics (MD) simulations using ReaxFF potential are performed to explore the atomic-scale corrosion mechanisms of body-centered cubic iron (BCC-Fe) in S-CO2. The results show that CO2 molecules in S-CO2 decompose at the Fe surface, generating free C and O atoms that form Fe-C and Fe-O bonds and subsequently produce oxides and carbides. Concurrently, Fe atoms dissolve from the surface and diffuse into the S-CO2 region, resulting in interdiffusion of Fe, C and O atoms at the interface. The corrosion-layer thickness calculations show that high pressure and temperature induced by S-CO2 have stronger effects than surface orientation on the corrosion process. In addition, surface Fe atoms undergo substantial displacement under S-CO2 exposure, further accelerating corrosion. When a radiation-induced void is introduced near the Fe surface, the corrosion is enhanced. The void-matrix interface expands the reaction surface area and simultaneously induces corrosion reactions inside the bulk, resulting in a deeper penetration of C and O and thicker corrosion layers. All these results indicate that high-temperature, high-pressure and radiation-induced voids can seriously affect the corrosion of Fe in S-CO2, and must be considered to better use S-CO2 in nuclear facilities.

Li, Wenhua

Process control-enabled mitigation of microstructural and plastic heterogeneities in additively manufactured Grade 91 steel

Synergizing wire arc-directed energy deposition (WA-DED) additive manufacturing (AM) with particle-strengthened creep strength-enhanced ferritic (CSEF) steels enables fabrication and repair of critical power-plant components. Investigations focused on fusion-welded particle-strengthened CSEF steels, such as Grade 91 steel, have linked microstructurally heterogeneous regions—forming due to heat affected zones (HAZ)—with premature failure during elevated temperature service. Fusion-based AM, including WA-DED, likewise generates microstructurally and plastically heterogeneous regions due to spatiotemporally varying thermokinetics during deposition. However, works investigating such microstructural heterogeneities, their implications for mechanical behavior, and strategies to mitigate their formation remain scarce. This work identifies microstructurally and plastically heterogeneous regions within the WA-DED-processed Grade 91 steel. Spatial microhardness variations in the as-fabricated specimen correlate with the variation in the attributes of grain, martensitic microstructure, and precipitates across the fusion zone and HAZ. Digital image correlation-enabled tensile tests performed at 500 °C revealed pronounced deformation localization and a wave-like strain distribution, with wavelength close to the melt pool depth, indicating susceptibility of the as-fabricated components to premature creep failure. Such heterogeneity in microstructural and mechanical behavior was attributed to recurring solid-state phase transformations. Subsequently, an interlayer temperature control strategy was implemented, wherein maintaining interlayer temperature above the martensitic start temperature mitigated the heterogeneous microstructural and plastic response in the as-fabricated condition. Findings open pathways to achieving deformation-localization- and creep-resistant microstructures in WA-DED fabricated particle-strengthened CSEF steel components, reducing reliance on post-welding heat treatments—conventionally required to enhance creep resistance—and enabling on-demand, short lead-time fabrication of next-generation power-plant components.

Heat affected zones

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]

Machine learning approach for vibronically renormalized electronic band structures

Here, we present a machine learning (ML) method for efficient computation of vibrational thermal expectation values of physical properties from first principles. Our approach is based on the nonperturbative frozen phonon formulation in which stochastic Monte Carlo algorithm is employed to sample configurations of nuclei in a supercell at finite temperatures based on a first-principles phonon model. A deep-learning neural network is trained to accurately predict physical properties associated with sampled phonon configurations, thus bypassing the time-consuming ab initio calculations. To incorporate the point-group symmetry of the electronic system into the ML model, group-theoretical methods are used to develop a symmetry-invariant descriptor for phonon configurations in the supercell. We apply our ML approach to compute the temperature dependent electronic energy gap of silicon based on density functional theory (DFT). We show that, with less than a hundred DFT calculations for training the neural network model, an order of magnitude larger number of sampling can be achieved for the computation of the vibrational thermal expectation values. Our work highlights the promising potential of ML techniques for finite temperature first-principles electronic structure methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Development of a Framework and Methodology for an Advanced Reactor Materials Environmental Effects Design Guide

Advanced non-light-water reactor components may operate at elevated temperature while experiencing cyclic loading, significant neutron irradiation, and exposure to reactor coolant. ASME Boiler and Pressure Vessel Code, Section III, Division 5, provides design rules for elevated-temperature service but does not include specific procedures to account for environmental effects on material properties. This report develops an initial framework and methodology for an Environmental Effects Design Guide (EEDG) focused on neutron irradiation; coolant-environment effects are reserved for future work. The proposed approach treats irradiation as a property-based overlay on the existing Division 5 design process, with two routes: a sparse-data route applying two reduction factors — FCR on creep-rupture strength and FF on fatigue life — for the creep-fatigue evaluations that typically control the design of advanced high-temperature reactor components, and a fuller framework developing the property-to-rule chain across the four Division 5 checks (primary load, strain limits and ratcheting, creep-fatigue, and buckling), together with swelling and weldments as scope items. Both routes are scoped by an in-pile qualification that restricts the use of post-irradiation-examination-derived properties in regimes where an in-pile mechanism could control the design outcome. Illustrative outputs derived on a compiled annealed Type 316 database — FCR ≈ 0.78–0.86 and FF ≈ 0.4 — demonstrate the calculation method within that specific dataset. The framework is an initial, testable design-rule concept; it identifies a practical path for preliminary design evaluations under sparse data and the material data and testing needed to develop the framework further.

Barua, Bipul (ORCID:0000000247184113)

Topological prethermal strong zero modes on superconducting processors

Abstract Symmetry-protected topological phases 1–4 cannot be described by any local order parameter and are beyond the conventional symmetry-breaking model 5 . They are characterized by topological boundary modes that remain stable under symmetry respecting perturbations 1–4,6–8 . In clean, gapped systems without disorder, the stability of these edge modes is restricted to the zero-temperature manifold; at finite temperatures, interactions with mobile thermal excitations lead to their decay 9–11 . Here we report the observation of a distinct type of topological edge mode 12–14 , which is protected by emergent symmetries and persists across the entire spectrum, in an array of 100 programmable superconducting qubits. Through digital quantum simulation of a one-dimensional disorder-free stabilizer Hamiltonian, we observe robust long-lived topological edge modes over up to 30 cycles for a wide range of initial states. We show that the interaction between these edge modes and bulk excitations can be suppressed by dimerizing the stabilizer strength, leading to an emergent U(1) × U(1) symmetry in the prethermal regime of the system. Furthermore, we exploit these topological edge modes as logical qubits and prepare a logical Bell state, which exhibits persistent coherence, despite the system being disorder-free and at finite temperature. Our results establish a viable digital simulation approach 15–18 to experimentally study topological matter at finite temperature and demonstrate a potential route to construct long-lived, robust boundary qubits in disorder-free systems.

Science & Technology - Other Topics

MRV Challenge 3: velocity and passive scalar comparison in a 3D turbulent flow

The third iteration of a magnetic resonance velocimetry (MRV) challenge comparison activity consisting of 3D flow measurements for a turbulent flow in a water channel moving past centrally positioned cubic obstacles is reported. In this challenge iteration, MRV measurements are coupled with either temperature or concentration measurements to extend the diagnostic utility. Five research teams from around the world conducted the measurements on a single shared apparatus. The water channel included partial elements along the channel sidewalls that varied in height and precluded easy optical accessibility. In addition to a turbulent mainstream flow, a secondary flow entered the channel between the second and third cubic elements from a square injector hole at the channel bottom wall. The injector jet interacts with the mainstream flow and mixes turbulently as it advects downstream. For the selected flow regime and water solutions used as working fluids, the mixing of the higher temperature or concentration through the secondary flow with the mainstream flow satisfies the same dynamics so that both temperature and concentration fields behave as passive scalars and can be directly compared. The measurements are explained in detail by each participating team, and the results are interpolated onto a common grid and compared using line profiles, contour plots, and isosurfaces.

Benson, Mike [ORNL] (ORCID:000000023210116X)

Mechanism of H 2 plasma-enabled reduction of hematite thin films

Hydrogen plasma is gaining significant interest as a promising pathway for direct iron ore reduction and for lowering process temperatures but the reduction mechanism remains poorly understood. In this work we analyzed the plasma and thermal reduction of thin-film hematite (Fe 2 O 3 ) at temperatures below 340 °C using X-ray diffraction and scanning electron microscopy with energy-dispersive X-ray spectroscopy. Plasma reduced the incubation period by an order of magnitude and increased the reduction rate by a factor of 2.6 compared to thermal reduction. Plasma-produced H-atoms facilitate the formation of numerous iron nucleation sites, bypassing the energetically unfavorable dissociative adsorption of H 2 on iron oxide. These iron nuclei can autocatalyze the reduction of the surrounding hematite via a hydrogen spillover mechanism. Our results demonstrate that plasma-derived H-atoms primarily impact the initial nucleation-limited stage. These new insights provide a mechanistic framework that can aid the implementation and optimization of hydrogen plasma-assisted iron oxide reduction at reduced temperatures.

08 HYDROGEN

Egg yolk as a model for gelation: From rheometry to flow physics

Egg yolks are an excellent model for studying sol-gel transitions, particularly the power law viscoelasticity that defines the critical point of gelation. However, prior studies lack comprehensive datasets and fail to visualize flow behavior linked to temperature and time-dependent linear and nonlinear rheology. Here, we present a detailed dataset characterizing egg yolk viscoelasticity across temperature, time, and forcing amplitude using oscillatory shear, step strain, step stress, and constant high strain rate. Novel protorheology visualizations link rheological properties with observable flow behavior. Our findings highlight the nuanced determination of the critical gel point, emphasizing observation timescale dependencies. We compare methods to identify critical temperatures for gelation, including power law viscoelasticity, moduli crossover, diverging zero-shear viscosity, and emerging equilibrium elastic modulus, while visualizing flow consequences near these transitions. Egg yolk is an accessible, realistic, and nontoxic material relevant to the physicist and the chef alike, making it ideal for understanding the rheology of critical gels. By integrating protorheology photos and videos with rigorous rheometric data, we deepen the understanding of critical gels, with broader impacts for studying other materials with sol-gel transitions.

Marsh, Maxwell C. [Department of Mechanical Scienc

Simple device modification simultaneously enhances indoor passive evaporative cooling power and duration

Passive evaporative cooling from a damp cloth or vessel can be used for localized cooling of perishables such as food and medicine, drinking water, and even people. Such applications have two key objectives, which are normally in tension with each other: minimizing the water consumption rate and maximizing the cooling (steady-state temperature swing between the cool cloth and the warm surroundings). Here, we present a simple device that delivers higher performance in both metrics simultaneously by adding a perforated aluminum foil sheet suspended over a stagnant air layer to thermally shield the evaporating surface while also facilitating mass transfer. Experimental results demonstrate a simultaneous 10%–25% increase in temperature swing and 2–3× reduction in water consumption rate as compared to conventional evaporative cooling. This improvement is achieved through careful modeling to optimize the coupled heat and mass transfer through the airgap (thermally insulating and vapor permeable) and perforated foil (infrared reflective and vapor permeable).

Chen, Sarah Mizuno

Heat metrics and thresholds reshape population exposure and inequality signals

Extreme heat is intensifying worldwide, yet estimates of heat hazard and exposure inequality depend on both the heat metric and how extreme days are defined. Using summer 2022 across the Mediterranean, we quantify population heat exposure with four metrics—land surface temperature (LST), air temperature (Ta), heat index (HI), and wet-bulb globe temperature (WBGT)—under absolute (fixed-value) and relative (anomaly-based) thresholds. Under absolute thresholds, total heat exposure differs by more than two orders of magnitude across metrics (31.3 billion person-days for Ta vs 0.3 billion for HI). Geographic hotspots also diverge: WBGT concentrates in humid coastal North Africa (e.g. the Nile Delta), whereas Ta and LST are more widespread. Under relative thresholds, exposure totals converge and cross-metric hotspot agreement increases (e.g. Ta–WBGT top-tercile overlap increases from 10.7% to 29.0%), shifting hotspots toward densely populated southern Europe. Crucially, the exposure–deprivation relationship also reverses across threshold frameworks: absolute thresholds concentrate exposure in more deprived North Africa and the Middle East, whereas relative thresholds shift the burden toward less-deprived European cities. This sensitivity is decision-relevant: city rankings based on WBGT exposure duration are almost completely reordered when switching threshold frameworks. Threshold choice therefore systematically reshapes hotspot patterns and inequality signals. Reporting both absolute and relative exposures can reveal hidden hotspots and support more targeted heat-risk monitoring and intervention planning.

Mediterranean

Photosynthetic capacity is reduced by warming but unaffected by elevated CO2 in seedlings of five boreal tree species

Abstract Increasing atmospheric CO2 concentrations fuel global warming, with boreal regions warming at a faster rate than many other areas. Boreal forests are an important component of the global carbon cycle, yet we have little data on photosynthetic responses of boreal trees to elevated CO2 (EC) and warming. We grew seedlings of 5 widespread North American boreal tree species (from Betula, Larix, Picea, and Pinus) under current (410 ppm) or elevated (750 ppm) CO2 and either ambient (+0 °C) or increased (+4 °C or +8 °C) temperature, then measured photosynthetic traits over a range of leaf temperatures. Our results were generally consistent across species: photosynthetic capacity (maximum rates of Rubisco carboxylation, Vcmax, and electron transport, Jmax) was unaffected by EC but decreased under +8 °C warming. Accordingly, net photosynthesis measured at the growth CO2 concentration (Agrowth) was reduced under warming and increased under EC. The thermal optimum for Agrowth (ToptA) increased by ∼1.8 °C with EC but increased with warming in only two species. In contrast, the activation energies and thermal optima for Vcmax and Jmax, which are used to estimate photosynthesis in Earth System Models, were unaffected by growth environment. There were a few interactions between growth, CO2, and warming. These results suggest increased photosynthesis of widespread boreal tree species under EC may be offset by future reductions in photosynthetic capacity related to warming. We also show that the temperature sensitivities of parameters used to estimate global photosynthesis in large-scale models are generally unaffected by simulated climate change in these species.

Plant Sciences

Chiral edge state control of thermoelectric effects

Thermoelectric responses in two-dimensional electron gases subjected to magnetic fields have the potential to provide unique information about quasiparticle statistics. In this study, we show that chiral edge states play a key role in thermoelectric Hall bar measurements by completely controlling the direction of the internal thermal gradient. To this end, we perform measurements of the magnetothermoelectric responses of cadmium arsenide quantum wells. The magnetothermoelectric responses in the quantum Hall regime agree with theoretical predictions if one considers the role of chiral edge states, which flow in opposite directions on either side of the Hall bar and establish an internal temperature gradient that is perpendicular to the externally applied thermal gradient. We show that the results are self-consistent within this picture under different measurement conditions. We discuss potential applications of the findings, such as in nanoscale control of local temperature gradients and thermoelectric effects along with the characterization of other topological systems with chiral edges states.

Science & Technology - Other Topics

STANDARD REFERENCE MATERIAL CHARPY TESTING FROM HIGH FLUENCE SURVEILLANCE CAPSULE

The Palisades Nuclear Generating Station included in its original surveillance program a surveillance capsule, designated A-60. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. It was harvested to perform characterization of surveillance specimens in this capsule in 2023. This capsule was irradiated to a fluence of 1.96x1020 n/cm2 (E> 1MeV) that is equivalent for more than 150 effective full power years for the current US reactor pressure vessel (RPV) fleet. This capsule contained several materials, including Charpy specimens of standard reference material (SRM) from Heavy-Section Steel Technology (HSST) A533-B Plate 01. To perform Charpy testing of this highly irradiated material, the new Charpy specimen transfer system was designed and implemented on Charpy impact testing machine in the hot cell to accommodate remote testing of these specimens. This new transfer system includes integrated environmental chamber to cool or heat Charpy specimens to the desired temperature. Testing of this highly irradiated material revealed very large shift of Charpy transition temperature, 188oC.

Sokolov, Mikhail [ORNL] (ORCID:0000000256373346)

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response

Phase stability in the Hf-N and Zr-N systems

Hf and Zr nitrides are promising compounds for many technologically important areas, including high-temperature structural applications, quantum computing, and solar and optical applications. Here, this article reports on a comprehensive first-principles statistical mechanics study of phase stability in the Hf-N and Zr-N binary systems. A high solubility of nitrogen in the hcp forms of Hf and Zr is predicted. The rocksalt forms of HfN and ZrN can also tolerate a high degree of off-stoichiometry through the introduction of nitrogen and metal vacancies. The Hf-N binary favors a family of stacking faulted parent crystal structures at intermediate nitrogen concentrations that host a unique form of short-range order among nitrogen interstitials and vacancies. These phases can accommodate some degree of configurational entropy and remain ordered to temperatures as high as 1200 K.

Monte Carlo methods