Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A New Source Biasing Approach in ADVANTG

The ADVANTG code has been developed at Oak Ridge National Laboratory to generate biased sources and weight window maps for MCNP using the CADIS and FW-CADIS methods. In preparation for an upcoming RSICC release, a new approach for generating a biased source has been developed. This improvement streamlines user input and improves reliability. Previous versions of ADVANTG generated the biased source from ADVANTG input, writing an entirely new general fixed-source definition (SDEF). Because volumetric sources were translated into SDEF-format as a finite set of points, the user had to perform a convergence study to determine whether the number of source points used accurately represented the source region. Further, the large number of points that must be written in SDEF-format made the MCNP input and output files excessively long and difficult to debug. ADVANTG now reads SDEF-format distributions and generates corresponding source biasing cards, eliminating the need for a convergence study. Many problems of interest use complicated source regions that are defined using cell rejection. In cell rejection, the source distribution in space is defined using an arbitrarily complex cell and a simple bounding region. Source positions are sampled within the bounding region but accepted only if they fall within the cell; otherwise, the position is resampled entirely. When biasing in space is applied to sources that use rejection sampling, current versions of MCNP do not account for the rejection in setting the source weight of histories, resulting in an 'unfair game'. This problem was circumvented in previous versions of ADVANTG by translating volumetric sources into a finite set of points, which does not alter the mean history weight ({bar w}). To use biasing parameters without otherwise modifying the original cell-rejection SDEF-format source, ADVANTG users now apply a correction factor for {bar w} in post-processing. A stratified-random sampling approach in ADVANTG is under development to automatically report the correction factor with estimated uncertainty. This study demonstrates the use of ADVANTG's new source biasing method, including the application of {bar w}.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Pulsar-Calibrated Timing Source for Synchronized Sampling

The Global Positioning System (GPS) is critical to the real-time synchronized sampling of phasor measurement units (PMUs). Unfortunately, GPS signals are occasionally unstable due to several factors such as weak satellite signal and GPS spoofing, thereby leaving the PMU with a degraded sampling performance. In this letter, a novel Pulsar-calibrated Timing Source (PTS) is proposed as the alternative timing source for synchronized sampling. Further, the PTS can generate the timing signal with a 1 μs drift error within 91 holdover minutes to ensure continuity of sampling accuracy. Experimental tests are conducted and the results reveal the reliability and accuracy of the PTS for PMU synchronization.

42 ENGINEERING↗

Influence of Nitrogen on Hydrogenated Amorphous Carbon Thin Films Deposited by Plasma Focus Device

To carry out our research, a plasma focus device is used to deposit thin films of nitrogen doped hydrogenated amorphous carbon (a-C:H:N) onto the stainless steel-AISI-304 substrates at room temperature. Thin films are deposited with the same numbers of focus shots, at the same distance from the anode tip and with different partial pressures of nitrogen in the mixtures of acetylene/nitrogen as working gas. The nitrogen contents of deposited films are studied using nuclear reaction analysis (NRA) techniques. The results prove that nitrogen contents of the samples do not increase significantly by increasing partial pressure of nitrogen of the working gas for both sets of the samples. Moreover, NRA results exhibit the limitation of nitrogen incorporated into the samples, when this experimental setup is used. G-peak position and peak intensity ratio of the D-band to G-band (I{sub D}/I{sub G}) are used to investigate the diamond characters. Also, they show that sp{sup 2} clustering is highly dependent on the nitrogen atomic contents and angular position of the samples. Scanning electron microscopy (SEM) shows the granular surface morphology of the films. Furthermore, it shows that angular position of the samples with respect to the anode axis plays an important role in the grain size of the surface of the samples. The thickness of the films decreases significantly by increasing angular position of the samples, while it decreases slightly by increasing partial pressure of nitrogen of the working gas. The Vickers surface hardness of the thin films exhibits significant dependency on the sp{sup 2} clustering.

36 MATERIALS SCIENCE↗

Magneto-optic superlattice thin films: Fabrication, structural and magnetic characterization

During this quarter studies were extended to determine the electronic contribution to the perpendicular interface anisotropy in Co-based multilayers. Using in situ Kerr effect measurements, the influences of different transition metals (TM = Ag, Au, Cu, and Pd) on the magnetic properties of single-crystal Co films grown on Pd (111) and Au (111) surfaces are investigated. Last quarter the discovery of a large peak in the perpendicular anisotropy when approximately one monolayer of Cu or Ag is deposited on the Co surface was reported. We now have added a computer-controlled stepper-motor drive to our MBE sample transfer mechanism. The motor allows us to move the sample at a constant velocity from behind a shutter during deposition. The film, therefore, is deposited as a wedge with a linear variation of thickness across the substrate. In this way, a continuous range of coverage on a single sample is studied. The stepper motor also provides the necessary control for precisely positioning the sample in the laser beam for Kerr effect measurements at the different coverages.

Falco, C. M.↗

Insights into Nb3Sn coating of CEBAF cavities from witness sample analysis

With the progress made in the Nb3Sn coatings on single-cell SRF cavities, development is ongoing to reproduce single-cell cavity results on practical structures such as CEBAF 5-cell cavities. During CEBAF cavity coating development, several changes from the single-cell procedure to the coating setup and the heating profile were introduced to improve the quality of Nb3Sn films. To witness the properties of grown Nb3Sn films in different cavity locations, 10 mm x 10 mm samples were positioned in strategic places within the coating chamber. Composition and structure of the samples were analyzed with surface analytic techniques and correlated with sample location during coatings. Implications from sample analysis to Nb3Sn coatings on different geometries are discussed in this contribution.

Eremeev, G. V.↗

K West Basin Sand Filter Backwash Sample Analysis

A sand filter is used to help maintain water clarity at the K West Basin where highly radioactive sludge is stored. Eventually that sand filter will require disposal. The radionuclide content of the solids trapped in the sand filter will affect the selection of the sand filter disposal pathway. The Pacific Northwest National Laboratory (PNNL) was contracted by the K Basin Operations & Plateau Remediation Project (operations contractor CH2M Hill) to analyze the radionuclide content of the solids collected from the backwash of the K West Basin sand filter. The radionuclide composition in the sand filter backwash solids will be used by CH2M Hill to determine if the sand filter media and retained sludge solids will be designated as transuranic waste for disposal purposes or can be processed through less expensive means. On October 19, 2015, K Basin Operations & Plateau Remediation Project staff backwashed the sand filter into the North Load-Out Pit (NLOP) and immediately collected sample slurry from a sampling tube positioned 24 in. above the NLOP floor. The 764 g sand filter backwash slurry sample, KW-105 SFBW-001, was submitted to PNNL for analysis on October 20, 2015. Solids from the slurry sample were consolidated into two samples (i.e., a primary and a duplicate sample) by centrifuging and measured for mass (0.82 g combined – wet centrifuged solids basis) and volume (0.80 mL combined). The solids were a dark brown/orange color, consistent with iron oxide/hydroxide. The solids were dried; the combined dry solids mass was 0.1113 g, corresponding to 0.0146 weight percent (wt%) solids in the original submitted sample slurry. The solids were acid-digested using nitric and hydrochloric acids. Insoluble solids developed upon dilution with 0.5 M HNO 3 , corresponding to an average 6.5 wt% of the initial dry solids content. The acid digestate and insoluble solids were analyzed separately by gamma spectrometry. Nominally, 7.7% of the 60 Co was present in the insoluble solids; less than 1% of other gamma-emitters (i.e., 137 Cs, 154/155 Eu, and 241 Am) were present in the insoluble solids. Aliquots of the acid digestate were analyzed directly using gamma energy analysis (GEA) and after separations for 238 Pu, 239+240 Pu, 237 Np, and 241 Am radioisotopes using alpha energy analysis (AEA). The 90 Sr was measured by liquid scintillation counting (LSC) on the Sr-separated fraction. The plutonium isotopic distribution of the acid digestate was analyzed following Pu separations by thermal ionization mass spectrometry (TIMS). A table summarizes the results for the primary and duplicate samples. The 239+240 Pu concentration (µCi/g dry) relative to 90 Sr and to 137 Cs concentrations (µCi/g dry) was examined. The K West Basin sludge has a 239+240 Pu/ 90 Sr ranging from 0.1 to 1.2 and the 239+240 Pu/ 137 Cs ratio ranging from 0.10 to 0.47. In contrast, the sand filter backwash solids 239+240 Pu/ 90 Sr ratio was 10.6 and the 239+240 Pu/ 137 Cs ratio was 2.0. The ratio differences indicate a relative enhancement of the Pu concentration in the sand filter solids relative to the 137 Cs and 90 Sr sludge concentrations currently in the K West Basin. A dose-to-curie radioisotope evaluation of the sand filter waste form may need to consider this dissimilarity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Epidemiology of Coccidioidomycosis (Valley fever) and the Disease Ecology of Coccidioides spp. in New Mexico (2006–2023)

Coccidioidomycosis (Valley fever), caused by Coccidioides spp., is a fungal infection endemic to semi-arid regions of the Americas. Despite 80 years of disease recognition in New Mexico, there is limited disease awareness. We incorporated clinical, epidemiological, and ecological datasets to summarize the knowledge of Valley fever in New Mexico. We analyzed 1541 human cases from 2006 to 2023. On average, 86 cases were reported each year (4.1 cases per 100,000 population per year). The highest levels of incidence were in southwestern New Mexico. American Indian or Alaska Natives in New Mexico had a 1.9 times higher incidence rate of coccidioidomycosis than White people, and among age groups, older populations in New Mexico had the highest incidence rates. We analyzed 300 soil samples near Las Cruces, New Mexico, for the presence of Coccidioides and reported the first known positive soil samples collected from the state, the majority of which were from grassland-dominated sites and from animal burrows. Sequence analyses in clinical specimens, wild animals, and soil samples confirmed that Coccidioides posadasii is the main causative species of coccidioidomycosis in New Mexico. Environmental surveillance validated that locally acquired infections could occur in, but are not limited to, Catron, Doña Ana, Sierra, and Socorro Counties.

54 ENVIRONMENTAL SCIENCES↗

Laser heating of aqueous samples on a micro-optical-electro-mechanical system

A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channel wherein the carrier fluid is not appreciably heated by the laser beam.

42 ENGINEERING↗

Laser heating of aqueous samples on a micro-optical-electro-mechanical system

A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channel wherein the carrier fluid is not appreciably heated by the laser beam.

47 OTHER INSTRUMENTATION↗

Laser heating of aqueous samples on a micro-optical-electro-mechanical system

A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channel wherein the carrier fluid is not appreciably heated by the laser beam.

47 OTHER INSTRUMENTATION↗

Laser heating of aqueous samples on a micro-optical-electro-mechanical system

A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channel wherein the carrier fluid is not appreciably heated by the laser beam.

47 OTHER INSTRUMENTATION↗

GIS-Based Modeling of Contaminated Soil Volumes at Multiple Sites in the Formerly Utilized Sites Remedial Action Program - 20149

The remediation of hazardous, toxic, and radioactive waste (HTRW) sites produces cost-related risks associated with the estimation of contaminated soil or debris volumes. Historical risk-management techniques include cost contingencies to cover volume uncertainties that affect project budgeting and decision-making. The Buffalo District teamed with project partners to lessen volume uncertainty and reduce project risks at multiple HTRW sites managed under the Formerly Utilized Sites Remedial Action Program (FUSRAP). Historical remedial investigations under FUSRAP commonly identified the presence of radiological material in site media, the associated human health risk, and then areas of remediation. To manage remedial execution and reduce risk, pre-design or remediation-phase sampling essentially 'chased' contamination, which was not conducive to efficient predictive budgeting derived from Feasibility Study (FS) cost analyses. The Buffalo District first optimized their approach to better understand volume uncertainty by utilizing the Argonne National Laboratory's Bayesian Approaches for Adaptive Spatial Sampling (BAASS) software [1]. BAASS processed soft data (e.g., gamma walk-over data) and spatial sampling data to estimate the lateral extent of contaminated soil irrespective of depth (i.e., gross contamination extent) and define areas of contaminant uncertainty. The software performed a binary transformation of contaminant concentrations at all sampling points based upon remedial action goals or a sum of ratios approach (i.e., clean, impacted, or range of impacts in soil). The model produced two-dimensional (horizontal) contaminant probability contours and statistical uncertainty in the sampling coverage and resulting contaminant extents. This method was translated vertically by partitioning the sampling data into depth brackets that produced a stacked representation of contaminant extents and uncertainty in the subsurface (i.e., similar to construction lifts). The results commonly led to a better understanding of project uncertainty and the need for sampling strategies that produce high-confidence soil volumes, which control costs. The BAASS-based delineations were eventually replaced by Empirical Bayesian Kriging (EBK) methods available in ArcGIS Spatial or 3D Analysts [2]. The EBK method calculates contaminant probability zones derived from user-controlled semivariograms of the spatial datasets. The resulting probability zones (e.g., 50% or 80% of contaminant probability) represent the two-dimensional surface delineation of the overall horizontal remedial area, similarly to BAASS. However, unlike BAASS, the vertical sampling data within these probability zones became vertical control points to contour a subterranean surface that connects subsurface points to the land-surface delineations of contamination. The resulting representation of horizontal and vertical impacts within an enclosed envelop (volume) of soil included uncertainty distributions that are used to plan uncertainty-reduction sampling. These data-driven and math-based models of three-dimensional sampling results produced well-bounded remedial volumes for project planning and better uncertainty predictions during project budgeting. The EBK method was applied to several FUSRAP sites managed by the Buffalo District and compared to less rigorously modeled sites previously remediated by the District. The comparison of modeled to actual remediated volumes provide a basis for validating the volume-estimation method. This comparison is important to ensure modeled volumes match physical boundaries of site remediation. FUSRAP sites with denser investigative sampling and lesser volume uncertainty proved useful in remedial planning and contracting. The Buffalo District noted that historical sites with sparser sampling arrays had greater disparity between estimated volumes and final remedial volumes. The benefit achieved over the cost of detailed soil sampling appears positive for FUSRAP projects, especially where impacts vary widely and appear unbounded by investigation-phase sampling. The subsequent Empirical Bayesian Kriging of contamination coupled with vertical contouring for soil estimations reduces uncertainty in soil volumes or indicates where sampling is required to reduce uncertainty, which together optimize remedial planning and budgeting. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robotic servicing system for space material experiment

A containerless image furnace with an electrostatic positioning device has been developed as one of the material experiment facilities on the Japanese experimental module (JEM). It is characterized by heating/melting/cooling the sample whose position is kept without any contacts by actively controlled electrostatic force exerted between the sample and a set of electrodes. The experiment using the image furnace requires various servicing operations. We have been developing a robotic servicing system with an internal robot accommodated in the rack as an alternative to the crew. It aims to reduce the load on the crew by automating regular tasks and to increase the flexibility applicable to simple irregular tasks by introducing a remote teleoperation scheme. The present robot has poor capability to replace the crew. In order to compensate it, introducing of the concept of the robot friendliness and improving the controllability of the teleoperation by the ground operator aids are essential. In this paper, we identify the tasks to be performed by the robotic servicing system and discuss the way to compensate the capability of the robot. In addition we describe the evaluation tests using an experimental model.

Yamawaki, Toshihiko↗

Holographic thin film analyzer

A system for the analysis and measurement of thin films in which the light output of a laser is split into two beams is discribed. The first beam is focused to illuminate the entire area of a photographic plate and the second beam is colummated and directed through a relatively small portion of the photographic plate onto the sample with the film to be observed. The surface of the sample is positioned at a slight angle with respect to a plane normal to the second beam and the light reflected from the sample arrives back at the photographic plate in a region other than through which the second beam originally passes. By making two successive exposures during the deposition of material on the surface of the sample, holograms are recorded on the photographic plate. The plate is then developed and interference lines of the hologram provide a measurement of the film or material deposited between exposure.

Williams, J. R.↗

Volatiles in melt inclusions from lunar mare basalts: Bridging the gap in the H 2 O/Ce ratio between melt Inclusions in lunar pyroclastic sample 74220 and other mare samples

The H2O concentration and H 2 O/Ce ratio in olivine-hosted melt inclusions are high in lunar pyroclastic sample 74220 (H 2 O up to 1410 ppmw; H 2 O/Ce up to 77) but lower (H2O 10 to 430 ppmw; H 2 O/Ce 0.3 to 9.4) in all other lunar samples studied before this work. The difference in H 2 O concentration and in H 2 O/Ce ratio is absent for other volatile elements (F, S, and Cl) in melt inclusions in 74220 and other lunar samples. Because H 2 O (or H) is a critical volatile component with significant ramifications on the origin and evolution of the Moon, it is important to understand what causes such a large gap in H 2 O/Ce ratio between 74220 and other lunar samples. Two explanations have been advanced. One is that volcanic product in sample 74220 has the highest cooling rate and thus best preserved H 2 O in melt inclusions compared to melt inclusions in other samples. The other explanation is that sample 74220 comes from a localized heterogeneity enriched in some volatiles. To distinguish these two possibilities, here we present new data from two rapidly cooled lunar samples with glassy melt inclusions: olivine-hosted melt inclusions (OHMIs) in 79135 regolith breccia (unknown cooling rate but with glassy MIs similar in texture with those in 74220), and pyroxene-hosted melt inclusions (PHMIs) in 15597 pigeonite basalts (known high cooling rate, second only to 74220 and 15421). In addition, we also investigated new OHMIs in sample 74220. If the gap is due to the difference in cooling rates, samples with cooling rates between those of 74220 and other studied lunar samples should have preserved intermediate H2O concentrations and H 2 O/Ce ratios. Our results show that melt inclusions in 79135 and 15597 contain high H 2 O concentrations (up to 969 ppmw in 79135 and up to 793 ppmw in 15597) and high H 2 O/Ce ratios (up to 21 in 79135 and up to 13 in 15997), bridging the big gap in H 2 O/Ce ratio among 74220 and other lunar samples. Combined with literature data, we confirm that H 2 O/Ce ratios of different lunar samples are positively correlated to the cooling rates and independent of the type of mare basalts. We hence reinforce the interpretation that the lunar sample with the highest cooling rate best represents pre-eruptive volatiles in lunar basalts due to the least degassing. Based on Ce concentration in the primitive lunar mantle, we estimate that H 2 O concentration in the primitive lunar mantle (meaning bulk silicate Moon) is 121 ± 15 ppmw. Our new data also further constrain F/P, S/Dy and Cl/Ba ratios in lunar basalts and the lunar mantle. Estimated F, P, and S concentrations in the lunar primitive mantle are 4.4 ± 1.1 ppmw, 22 ± 8 ppmw, and 67 +67 −33 ppmw, respectively.

Xue Su↗

Health significance and occurrence of injured bacteria in drinking water

Enteropathogenic and indicator bacteria become injured in drinking water with exposure to sublethal levels of various biological, chemical and physical factors. One manifestation of this injury is the inability to grow and form colonies on selective media containing surfactants. The resulting underestimation of indicator bacteria can lead to a false estimation of water potability. m-T7 medium was developed specifically for the recovery of injured coliforms (both "total" and fecal) in drinking water. The m-T7 method was used to survey operating drinking water treatment and distribution systems for the presence of injured coliforms that were undetected with currently used media. The mean recovery with m-Endo LES medium was less than 1/100 ml while it ranged between 6 and 68/100ml with m-T7 agar. The majority of samples giving positive results with m-T7 medium yielded no detectable coliforms with m-Endo LES agar. Over 95% of the coliform bacteria in these samples were injured. Laboratory experiments were also done to ascribe the virulence of injured waterborne pathogens. Enteropathogens including Salmonella typhimurium, Yersinia enterocolitica and Shigella spp. required up to 20 times the chlorine levels to produce the same injury in enterotoxigenic Escherichia coli (ETEC) and nonpathogenic coliforms. Similar results were seen with Y. enterocolitica exposed to copper. The recovery of ETEC was followed by delayed enterotoxin production, both in vitro and in the gut of experimental animals. This indicates that injured waterborne enteropathogenic bacteria can be virulent.

NASA Discipline Number 13-40↗

Interactions of cesium and barium ions with calcium silicate hydrate under the condition saturated with saline water - 15247

The interaction of cesium (Cs) and barium (Ba) ions with calcium silicate hydrate (CSH gel) without drying processes was examined under the condition saturated with saline water, by monitoring the concentrations of Cs and Ba and using the Raman spectroscopy and the zeta potential. In the experiments, Ca/Si molar ratios of CSH gel were set to 0.4, 0.8, 1.2 and 1.6. Each sample was synthesized with CaO powder, SiO{sub 2} powder and NaCl solution in given combinations. The concentration of NaCl solution was set to 0.006, 0.06 and 0.6 M. At the same time, CsCl or BaCl{sub 2} solution was added to the sample in order to adjust its concentration to 1.0 mM. The curing period was set to 7, 14, 30 days. As a results, the sorption of Cs and Ba ions on CSH gel became stronger with lower Ca/Si molar ratio. On the other hand, even though the zeta potential showed the surface charge of higher Ca/Si ratio samples was positive charge which inhibits the sorption of cations, Cs and Ba ions significantly sorbed on CSH gel. In addition, Raman spectra of higher Ca/Si ratio samples showed that the degree of depolymerization of silicate chain increased with the sorption of Cs and Ba ions on CSH gel. In other words, even in higher Ca/Si ratio samples, Cs and Ba ions can sorb on CSH gel through the structural deformation of CSH gel. These results suggest that CSH gel might be able to contribute the migration retardation of Cs and/or Ba ions through the interaction with CSH gel, even if the near-field of the geological repository are saturated by saline groundwater. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic sample Dewar for MX beam-line

It is very common for crystals of large biological macromolecules to show considerable variation in quality of their diffraction. In order to increase the number of samples that are tested for diffraction quality before any full data collections at the ESRF*, an automatic sample Dewar has been implemented. Conception and performances of the Dewar are reported in this paper. The automatic sample Dewar has 240 samples capability with automatic loading/unloading ports. The storing Dewar is capable to work with robots and it can be integrated in a full automatic MX** beam-line. The samples are positioned in the front of the loading/unloading ports with and automatic rotating plate. A view port has been implemented for data matrix camera reading on each sample loaded in the Dewar. At last, the Dewar is insulated with polyurethane foam that keeps the liquid nitrogen consumption below 1.6 L/h. At last, the static insulation also makes vacuum equipment and maintenance unnecessary. This Dewar will be useful for increasing the number of samples tested in synchrotrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗