Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A MARKOV CHAIN MONTE CARLO ALGORITHM FOR ANALYSIS OF LOW SIGNAL-TO-NOISE COSMIC MICROWAVE BACKGROUND DATA

We present a new Markov Chain Monte Carlo (MCMC) algorithm for cosmic microwave background (CMB) analysis in the low signal-to-noise regime. This method builds on and complements the previously described CMB Gibbs sampler, and effectively solves the low signal-to-noise inefficiency problem of the direct Gibbs sampler. The new algorithm is a simple Metropolis-Hastings sampler with a general proposal rule for the power spectrum, C {sub l}, followed by a particular deterministic rescaling operation of the sky signal, s. The acceptance probability for this joint move depends on the sky map only through the difference of {chi}{sup 2} between the original and proposed sky sample, which is close to unity in the low signal-to-noise regime. The algorithm is completed by alternating this move with a standard Gibbs move. Together, these two proposals constitute a computationally efficient algorithm for mapping out the full joint CMB posterior, both in the high and low signal-to-noise regimes.

79 ASTRONOMY AND ASTROPHYSICS↗

Sequential Kalman tuning of the t -preconditioned Crank-Nicolson algorithm: efficient, adaptive and gradient-free inference for Bayesian inverse problems

Ensemble Kalman Inversion (EKI) has been proposed as an efficient method for the approximate solution of Bayesian inverse problems with expensive forward models. However, when applied to the Bayesian inverse problem EKI is only exact in the regime of Gaussian target measures and linear forward models. Here, in this work we propose embedding EKI and Flow Annealed Kalman Inversion, its normalizing flow (NF) preconditioned variant, within a Bayesian annealing scheme as part of an adaptive implementation of the t-preconditioned Crank-Nicolson (tpCN) sampler. The tpCN sampler differs from standard pCN in that its proposal is reversible with respect to the multivariate t-distribution. The more flexible tail behaviour allows for better adaptation to sampling from non-Gaussian targets. Within our Sequential Kalman Tuning (SKT) adaptation scheme, EKI is used to initialize and precondition the tpCN sampler for each annealed target. The subsequent tpCN iterations ensure particles are correctly distributed according to each annealed target, avoiding the accumulation of errors that would otherwise impact EKI. We demonstrate the performance of SKT for tpCN on three challenging numerical benchmarks, showing significant improvements in the rate of convergence compared to adaptation within standard SMC with importance weighted resampling at each temperature level, and compared to similar adaptive implementations of standard pCN. The SKT scheme applied to tpCN offers an efficient, practical solution for solving the Bayesian inverse problem when gradients of the forward model are not available. Code implementing the SKT schemes for tpCN is available at https://github.com/RichardGrumitt/KalmanMC.

97 MATHEMATICS AND COMPUTING↗

Solids Accumulation Scouting Studies

The objective of Solids Accumulation activities was to perform scaled testing to understand the behavior of remaining solids in a Double Shell Tank (DST), specifically AW-105, at Hanford during multiple fill, mix, and transfer operations. It is important to know if fissionable materials can concentrate when waste is transferred from staging tanks prior to feeding waste treatment plants. Specifically, there is a concern that large, dense particles containing plutonium could accumulate in poorly mixed regions of a blend tank heel for tanks that employ mixing jet pumps. At the request of the DOE Hanford Tank Operations Contractor, Washington River Protection Solutions, the Engineering Development Laboratory of the Savannah River National Laboratory performed a scouting study in a 1/22-scale model of a waste staging tank to investigate this concern and to develop measurement techniques that could be applied in a more extensive study at a larger scale. Simulated waste tank solids: Gibbsite, Zirconia, Sand, and Stainless Steel, with stainless steel particles representing the heavier particles, e.g., plutonium, and supernatant were charged to the test tank and rotating liquid jets were used to mix most of the solids while the simulant was pumped out. Subsequently, the volume and shape of the mounds of residual solids and the spatial concentration profiles for the surrogate for heavier particles were measured. Several techniques were developed and equipment designed to accomplish the measurements needed and they included: 1. Magnetic particle separator to remove simulant stainless steel solids. A device was designed and built to capture these solids, which represent the heavier solids during a waste transfer from a staging tank. 2. Photographic equipment to determine the volume of the solids mounds. The mounds were photographed as they were exposed at different tank waste levels to develop a composite of topographical areas. 3. Laser rangefinders to determine the volume of the solids mounds. The mounds were scanned after tank supernatant was removed. 4. Core sampler to determine the stainless steel solids distribution within the solids mounds. This sampler was designed and built to remove small sections of the mounds to evaluate concentrations of the stainless steel solids at different special locations. 5. Computer driven positioner that placed the laser rangefinders and the core sampler in appropriate locations over solids mounds that accumulated on the bottom of a scaled staging tank where mixing is poor. These devices and techniques were effective to estimate the movement, location, and concentrations of the solids representing heavier particles and could perform well at a larger scale The experiment contained two campaigns with each comprised of ten cycles to fill and empty the scaled staging tank. The tank was filled without mixing, but emptied, while mixing, in seven batches; the first six were of equal volumes of 13.1 gallons each to represent the planned fullscale batches of 145,000 gallons, and the last, partial, batch of 6.9 gallons represented a full-scale partial batch of 76,000 gallons that will leave a 72-inch heel in the staging tank for the next cycle. The sole difference between the two campaigns was the energy to mix the scaled staging tank, i.e., the nozzle velocity and jet rotational speed of the two jet pumps. Campaign 1 used 22.9 ft/s, at 1.54 rpm based on past testing and Campaign 2 used 23.9 ft/s at 1.75 rpm, based on visual observation of minimum velocity that allowed fast settling solids, i.e., sand and stainless steel, to accumulate on the scaled tank bottom.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comprehensive Air Monitoring Report for Measurements during the Las Conchas Fire at Los Alamos National Laboratory

During the Las Conchas Fire, ambient air was monitored for radionuclides and particulate matter at and around Los Alamos National Laboratory (the Laboratory). During the fire, a variety of samplers were deployed, including the radiological air sampling network, high-volume air samplers, Tapered Element Oscillating Microbalances (PM 2.5 and PM 10), and environmental continuous air monitors. These different types of samplers provided real time, more in-depth retrospective information on air quality. In total, roughly 220 air samples were collected, and the results were consistent with other regional fires. Laboratory officials and Los Alamos County used real-time data to make public health risk determinations according to the Air Quality Index. Particulate levels were elevated and exceeded the National Ambient Air Quality Standard during the fire because of smoke. Elevated levels of naturally occurring radon decay products, consistent with all forest fires, were detected. Gross-alpha measurements had an average of range of 400 aCi/m 3 to 13,400 aCi/m 3 . Measurements of gross beta during the fire had a range of 34,000 aCi/m 3 to 74,000 aCi/m 3 . These values are not statistically different from national or regional averages.

54 ENVIRONMENTAL SCIENCES↗

SRS environmental air surveillance program 1954-2015: General trends

The radiological monitoring program at SRS was established under the DuPont Company in June 1951 and was used as a measurement of the effectiveness of plant controls and as an authoritative record of environmental conditions surrounding the plant. It also served as a method of demonstrating compliance with applicable federal regulations and guidance. This document serves as a general summary of changes made specifically to the environmental air monitoring program since its inception, and a discussion of the general trends seen in the air monitoring program at SRS from 1954 to 2015. Initially, the environmental air surveillance program focused not only on releases from SRS but also on fallout from various weapons testing performed through the end of 1978. Flypaper was used to measure the amount of fallout in the atmosphere during this period, and was present at each of the 10 monitoring stations. By 1959, all site stacks were included in the air monitoring program to determine their contribution to the airborne radioactivity onsite, and the number of air surveillance samplers rose to 18. This trend of an increased number of sampling locations continued to a peak of 35 sampling locations before shifting to a downward trend in the mid-1990s. In 1962, 4 outer-range samplers were placed in Savannah and Macon, GA, and in Greenville and Columbia, SC. Until 1976, air samplers were simply placed around the perimeter of the various operation locations (after 1959, this included stacks to determine their contribution to the airborne radioactivity), with the intent of creating as representative a distribution as possible of the air surrounding operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigations into the origins of polyatomic ions in inductively coupled plasma-mass spectrometry

An inductively coupled plasma-mass spectrometer (ICP-MS) is an elemental analytical instrument capable of determining nearly all elements in the periodic table at limits of detection in the parts per quadrillion and with a linear analytical range over 8-10 orders of magnitude. Three concentric quartz tubes make up the plasma torch. Argon gas is spiraled through the outer tube and generates the plasma powered by a looped load coil operating at 27.1 or 40.6 MHz. The argon flow of the middle channel is used to keep the plasma above the innermost tube through which solid or aqueous sample is carried in a third argon stream. A sample is progressively desolvated, atomized and ionized. The torch is operated at atmospheric pressure. To reach the reduced pressures of mass spectrometers, ions are extracted through a series of two, approximately one millimeter wide, circular apertures set in water cooled metal cones. The space between the cones is evacuated to approximately one torr. The space behind the second cone is pumped down to, or near to, the pressure needed for the mass spectrometer (MS). The first cone, called the sampler, is placed directly in the plasma plume and its position is adjusted to the point where atomic ions are most abundant. The hot plasma gas expands through the sampler orifice and in this expansion is placed the second cone, called the skimmer. After the skimmer traditional MS designs are employed, i.e. quadrupoles, magnetic sectors, time-of-flight. ICP-MS is the leading trace element analysis technique. One of its weaknesses are polyatomic ions. This dissertation has added to the fundamental understanding of some of these polyatomic ions, their origins and behavior. Although mainly continuing the work of others, certain novel approaches have been introduced here. Chapter 2 includes the first reported efforts to include high temperature corrections to the partition functions of the polyatomic ions in ICP-MS. This and other objections to preceeding papers in this area were addressed. Errors in the measured T gas values were found for given errors in the experimental and spectroscopic values. The ionization energy of the neutral polyatomic ion was included in calculations to prove the validity of ignoring more complicated equilibria. Work was begun on the question of agreement between kinetics of the plasma and interface and the increase and depletion seen in certain polyatomic ions. This dissertation was also the first to report day to day ranges for T gas values and to use a statistical test to compare different operating conditions. This will help guide comparisons of previous and future work. Chapter 4 was the first attempt to include the excited electronic state 2 in the partition function of ArO + as well as the first to address the different dissociation products of the ground and first electronic levels of ArO + . Chapter 5 reports an interesting source of memory in ICP-MS that could affect mathematical corrections for polyatomic ions. For future work on these topics I suggest the following experiments and investigations. Clearly not an extensive list, they are instead the first topics curiosity brings to mind. (1) Measurement of T gas values when using the flow injection technique of Appendix B. It was believed that there was a fundamental difference in the plasma when the auto-sampler was used versus a continuous injection. Is this reflected in T gas values? (2) The work of Chapter 3 can be expanded and supplemented with more trials, new cone materials (i.e. copper, stainless steel) and more cone geometries. Some of this equipment is already present in the laboratory, others could be purchased or made. (3) T gas values from Chapter 3 could be correlated with instrument pressures during the experiment. Pressures after the skimmer cone were recorded for many days but have yet to be collated with the measured T gas values. (4) The work in Chapter 5 could be expanded to include more metals. Does the curious correlation between measured T gas and element boiling point persist? (5) Investigate non-linear correlations to T gas values of the MO + memory in Chapter 5. Temperatures along the skimmer walls are not a linear gradient. Ring deposits have been observed on the cone and photographs of the interface show light intensities shaping a sort of tailing peak along the outside skimmer wall. Is there a physical property of the metals or metal oxides that would give this peak with the T gas values? (6) Chemical state speciation of the metal deposits on the skimmers of Chapter 5. There may be a more logical correlation between Tgas and a physical property of the deposit-ing chemical if all the metals do not deposit in the same form. (7) A collaboration with our computational collegues would be most welcome. Newer calculations for ArO + and RuO + would be very helpful.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Dimensional Bayesian Optimization via Semi-Supervised Learning with Optimized Unlabeled Data Sampling

We introduce a novel semi-supervised learning approach, named Teacher-Student Bayesian Optimization (TSBO ), integrating the teacher-student paradigm into BO to minimize expensive labeled data queries for the first time. TSBO incorporates a teacher model, an unlabeled data sampler, and a student model. The student is trained on unlabeled data locations generated by the sampler, with pseudo labels predicted by the teacher. The interplay between these three components implements a unique selective regularization to the teacher in the form of student feedback. This scheme enables the teacher to predict high-quality pseudo labels, enhancing the generalization of the GP surrogate model in the search space. To fully exploit TSBO , we propose two optimized unlabeled data samplers to construct effective student feedback that well aligns with the objective of Bayesian optimization. Furthermore, we quantify and leverage the uncertainty of the teacher-student model for the provision of reliable feedback to the teacher in the presence of risky pseudo-label predictions. TSBO demonstrates significantly improved sample-efficiency in several global optimization tasks under tight labeled data budgets. The implementation is available at https://github.com/reminiscenty/TSBO-Official.

Yin, Yuxuan↗

Unlimbering Viking's scoop

A number of difficulties which were encountered in deploying the Viking 1 lander's surface-sampler arm are discussed. When the surface sampler jammed during its initial operation, the problem was studied with the aid of tests on a full-scale lander mock-up. It was found that the difficulty was caused by a boom latch pin which had failed to fall clear. The surface-sampler arm could subsequently be freed by modifying the original command sequence. Another difficulty could be overcome by a similar approach.

Spitzer, C. R.↗

Description and field test of an in situ coliform monitoring system

A prototype in situ system for monitoring the levels of fecal coliforms in shallow water bodies was developed and evaluated. This system was based on the known relationship between the concentration of the coliform bacteria and the amount of hydrogen they produce during growth in a complex organic media. The prototype system consists of a sampler platform, which sits on the bottom; a surface buoy, which transmits sampler-generated data; and a shore station, which receives, displays the data, and controls the sampler. The concept of remote monitoring of fecal coliform concentrations by utilizing a system based on the electrochemical method was verified during the evaluation of the prototype.

Grana, D. C.↗

Volcanic impact on stratospheric aerosol chemistry

Samples collected by the National Center for Atmospheric Research (NCAR) using the multiple-filter sampler on the U-2 were analyzed. The sampler is capable of exposing a number of 110 mm filters in sequence to ram air flow. Two types of filters, IPC cellulose and polystrene, were used, both of which have high blank levels for the trace elements determined. The levels of most trace elements in the stratosphere are so low under normal circumstances that none can be seen. Results from the eruption of Mt. St. Helens, a mystery cloud (probably volcanic in origin) in 1982, and the El Chichonal eruption in 1983 are discussed. To improve the collection of particles for chemical analysis, a new sampling system was developed for use on the U-2. The sampler consisted of an electrostatic collection of particles between 1 and 0.001 micron diameter dierectly onto electron microscopic grids, followed by a thermal precipitation for the smaller particles. The system was built and tested in the laboratory, but never flown on the U-2.

Zoller, W. H.↗

How successful were the lunar sampling tools: Implications for sampling Mars

Like the Mars Sample Return endeavor, the Apollo lunar-sample program began with definition of strategy for sample collection and of scientific requirements for sampling hardware design. Several lessons can be illustrated by specific tools. The evolution of drive tubes from narrow 2 cm diameter, thick-walled tubes (used on Apollo 11, 12 and 14) to 4 cm diameter, thin-walled tubes used on Apollo 15, 16, and 17) as an example of the improvements made possible during multiple missions. The original Apollo 11 drive tube was designed to work in fluffy soil; thus, only 50 percent of the relatively dense lunar soil was recovered, and the core was distorted. The final configuration resulted in nearly 100 pct recovery with little distortion. The surface samplers (Contact Soil Sampling Devices) were designed to collect the upper 100 micrometer or the upper 1 mm of soil. It was over 2 years after the mission before these particularly specific samplers were opened because interest in them waned. Both core tubes and surface samplers were difficult to open in the laboratory. The Apollo Lunar Sample Return Containers (ALSRCs) were constructed with one indium and 2 Viton seals. They were closed on the lunar surface. Interior container pressures measured upon return to the laboratory indicate that these seals were not reliable in the lunar environment. Also, choice of indium as a sealing material interfered with siderophile analyses of samples.

Allton, J. H.↗

A Side by Side Comparison of Filter-Based PM(sub 2.5) Measurements at a Suburban Site: A Closure Study

Reliable determination of the effects of air quality on public health and the environment requires accurate measurement of PM(sub 2.5) mass and the individual chemical components of fine aerosols. This study seeks to evaluate PM(sub 2.5) measurements that are part of a newly established national network by comparing them with a more conventional sampling system. Experiments were carried out during 2002 at a suburban site in Maryland, United States, where two samplers from the U.S. Environmental Protection Agency (USEPA) Speciation Trends Network: Met One Speciation Air Sampling System STNS and Thermo Scientific Reference Ambient Air Sampler STNR, two Desert Research Institute Sequential Filter Samplers DRIF, and a continuous TEOM monitor (Thermo Scientific Tapered Element Oscillating Microbalance) were sampling air in parallel. These monitors differ not only in sampling configuration but also in protocol-specific sample analysis procedures. Measurements of PM(sub 2.5) mass and major contributing species were well correlated among the different methods with r-values > 0.8. Despite the good correlations, daily concentrations of PM(sub 2.5) mass and major contributing species were significantly different at the 95% confidence level from 5 to 100% of the time. Larger values of PM(sub 2.5) mass and individual species were generally reported from STNR and STNS. The January STNR average PM(sub 2.5) mass (8.8 (micro)g/per cubic meter) was 1.5 (micro)g/per cubic meter larger than the DRIF average mass. The July STNS average PM(sub 2.5) mass (27.8 (micro)g/per cubic meter) was 3.8 (micro)g/per cubic meter larger than the DRIF average mass. These differences can only be partially accounted for by known random errors. Variations in flow control, face velocity, and sampling artifacts likely influence the measurement of PM(sub 2.5) speciation and mass closure. Simple statistical tests indicate that the current uncertainty estimates used in the STN network may underestimate the actual uncertainty.

Haines, Jennifer C.↗

Integrated Modeling of Spacecraft Touch-and-Go Sampling

An integrated modeling tool has been developed to include multi-body dynamics, orbital dynamics, and touch-and-go dynamics for spacecraft covering three types of end-effectors: a sticky pad, a brush-wheel sampler, and a pellet gun. Several multi-body models of a free-flying spacecraft with a multi-link manipulator driving these end-effectors have been tested with typical contact conditions arising when the manipulator arm is to sample the surface of an asteroidal body. The test data have been infused directly into the dynamics formulation including such information as the mass collected as a function of end-effector longitudinal speed for the brush-wheel and sticky-pad samplers, and the mass collected as a function of projectile speed for the pellet gun sampler. These data represent the realistic behavior of the end effector while in contact with a surface, and represent a low-order model of more complex contact conditions that otherwise would have to be simulated. Numerical results demonstrate the adequacy of these multibody models for spacecraft and manipulator- arm control design. The work contributes to the development of a touch-and-go testbed for small body exploration, denoted as the GREX Testbed (GN&C for Rendezvous-based EXploration). The GREX testbed addresses the key issues involved in landing on an asteroidal body or comet; namely, a complex, low-gravity field; partially known terrain properties; possible comet outgassing; dust ejection; and navigating to a safe and scientifically desirable zone.

Quadrelli, Marco↗

Culture-Independent Microbial Air Profiling using a Spaceflight-Compatible Nanopore Sequencing Method

Microbial monitoring of spacecraft air is critical toward assessing the efficacy of microbial controls within the environmental control and life support systems to protect both the crew and the vehicle environment. Additionally, understanding of the atmospheric microbial profiles will be essential toward Mars-forward planetary protection planning. Currently, onboard the International Space Station (ISS), the air is monitored on a quarterly basis using an impaction air sampler. With this method, bacterial and fungal cells and spores are pulled onto plates containing growth medium. Following five days of ambient incubation onboard the ISS, the crew compares the growth to density charts and provides the approximations to the ground. Upon return of the culture plates to the Johnson Space Center’s Microbiology Laboratory, the isolates present are identified for crew health risk assessments. As NASA moves beyond the low-Earth orbit of ISS, sample return will be impractical. As such, a near real-time monitoring capability for the assessment of the spacecraft atmosphere is necessary. Significant strides have been made in recent years to utilize a molecular-based method for microbial profiling of ISS surfaces. The developed method is not dependent on microbial culture, thus removing the associated risk to the crew from high microbial levels, the bias toward detecting only the culturable organisms, and eliminates the need for sample return. The work described here details the evaluation of three different air sampling platforms whose product is amenable to downstream molecular processing and nanopore sequencing. The three samplers were compared in terms of mass and power requirements, ease-of -use, and the resulting data. For the two highest ranking samplers, a basic concept of operations was developed to transfer the sample into the already established preparation and sequencing process. Using these concepts of operations, an in-depth comparison of the molecular data generated was compared to the historical culture-based method. Data from both methods detailed similar microbial profiles, while the molecular method detailed microbial identifications that could not be identified through the culture-based method. The developed method will enable the generation of near real-time microbial profiles of the spacecraft atmosphere.

Brandon J Dunbar↗

Culture-Independent Microbial Air Profiling using a Spaceflight-Compatible Nanopore Sequencing Method

Microbial monitoring of spacecraft air is critical toward assessing the efficacy of microbial controls within the environmental control and life support systems to protect the crew and vehicle environment. Currently, onboard the International Space Station (ISS), the air is monitored every quarter using an impaction air sampler. With this method, microbial cells and spores are pulled onto plates containing a growth medium. Following onboard incubation, the crew reports approximate microbial levels to the ground, but sample return is required for identification. Upon return of the plates, the isolates present are identified for crew health risk assessments. As NASA moves beyond low-Earth orbit, sample return will be impractical, and a near real-time monitoring capability is essential. Significant strides have been made in recent years to utilize a molecular-based method for microbial profiling of ISS surfaces. The developed method is independent of microbial culture, thus removing the bias toward detecting only culturable organisms, eliminating the need for sample return, and reducing the risk to crew health from exposure to high microbial levels. The work described here details the evaluation of three different air sampling platforms whose product is amenable to downstream molecular processing. The three samplers were compared in terms of mass and power requirements, ease of use, and the resulting data. For the two highest-ranking samplers, a basic concept of operations was developed to transfer the sample into the already established preparation and sequencing process. Using these concepts of operations, an in-depth comparison of the molecular data generated was compared to the historical culture-based method. Data from both methods detailed similar microbial profiles, while the molecular method detailed microbial identifications that were lacking from the culture data. The developed method will enable the generation of near real-time microbial profiles of the spacecraft atmosphere.

Brandon Dunbar↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

Quantification of Uncertainties and Correlations in Criticality Experiments With SCALE

Uncertainties in benchmark keff values due to uncertainties in individual components, such as geometry and material compositions, are rigorously quantified and documented in evaluations provided in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). Correlations between the uncertainties may affect not only the overall uncertainty for a series of benchmarks but also the magnitude of computational biases and bias uncertainties quantified by validation methods. The impact of the correlations in experimental uncertainties is especially important in the use of advanced validation methods such as Generalized Linear Least Squares (GLLS), as implemented in the SCALE TSURFER code. In a recent study, it was demonstrated that biases computed with GLLS procedures vary by as much as 75%, depending on the selection of the experimental uncertainty correlation value. of the >4000 benchmarks documented in the IHECSBE; experimental correlation data are only available in the DICE database tool for ~60 benchmarks. Additional data are available in DICE to identify the potential for correlations between evaluations, but the values of correlations are not quantified. The new Sampler module of SCALE provides stochastic capabilities to quantify uncertainties and correlations in keff or any other measured value for one or more benchmark experiments due to uncertainties in individual sources of uncertainty, such as geometry and material composition. The values for individual parameters in the input model are randomly modified within the reported uncertainty, and a distribution function and a series of perturbed keff values are obtained. Where sufficient samples are made, the distribution of the perturbed keff values is used to determine the uncertainty in the keff due to uncertainties in the input parameters. In cases where the same uncertainty parameters influence multiple experiments, such as where the same fissile solution or fuel rods are used for many critical measurements, the simultaneous perturbation of an uncertain parameter for multiple cases provides the correlation in keff uncertainties between the different configurations. The parametric uncertainty capabilities of Sampler for a single system are demonstrated for a benchmark exercise from the Organization for Economic Cooperation and Development (OECD) Nuclear Energy Agency (NEA) Working Party on Nuclear Criticality Safety (WPNCS) Expert Group on Uncertainty Analysis for Criticality Safety Assessment (UACSA) Phase II benchmark. Sampler is further applied to quantify correlations among benchmarks from a series of highly enriched uranium (HEU) solution (SOL) thermal spectrum (THERM) systems, through the analysis of the 10 cases from HEU-SOL-THERM-001 from the IHECSBE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Laser-Based Method for On-Site Analysis of UF6 at Enrichment Plants

The International Atomic Energy Agency’s (IAEA’s) long-term research and development plan calls for more cost-effective and efficient safeguard methods to detect and deter misuse of gaseous centrifuge enrichment plants (GCEPs). The IAEA’s current safeguards approaches at GCEPs are based on a combination of routine and random inspections that include environmental sampling and destructive assay (DA) sample collection from UF6 in-process material and selected cylinders. Samples are then shipped offsite for subsequent laboratory analysis. In this paper, a new DA sample collection and onsite analysis approach that could help to meet challenges in transportation and chain of custody for UF6 DA samples is introduced. This approach uses a handheld sampler concept and a Laser Ablation, Laser Absorbance Spectrometry (LAARS) analysis instrument, both currently under development at the Pacific Northwest National Laboratory. A LAARS analysis instrument could be temporarily or permanently deployed in the IAEA control room of the facility, in the IAEA data acquisition cabinet, for example. The handheld PNNL DA sampler design collects and stabilizes a much smaller DA sample mass compared to current sampling methods. The significantly lower uranium mass reduces the sample radioactivity and the stabilization approach diminishes the risk of uranium and hydrogen fluoride release. These attributes enable safe sample handling needed during onsite LAARS assay and may help ease shipping challenges for samples to be processed at the IAEA’s offsite laboratory. The LAARS and DA sampler implementation concepts will be described and preliminary technical viability results presented.

LAARS↗