Search NASA⌕ Search

SEARCH · Search NASA

Results for “SINGLE PHOTON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Search For Low-Mass Quark-Antiquark Resonances Produced With an Initial State Photon at 13 TeV Using the CMS Detector

We present a search for low-mass narrow qq̅ resonances. This search uses data from LHC pp collisions at a center of mass of 13 TeV in Run 2, and corresponds to an integrated luminosity of 137 fb^{-1}, currently using 10\% of data. Utilizing full Run 2 data allows the use of a lower photon pT threshold trigger than a previous analysis performed with only 2016 data, allowing this analysis to be more sensitive to resonances in the low mass region. We require an initial state photon recoiling against the narrow resonance, leading to the resonance having a high transverse momentum. The high pT decay products of the resonance collimate and are reconstructed as a single large jet with an internal two-pronged substructure. A two-pronged dijet score based on the ParticleNet tagger is used to select jets with two-pronged substructure. The background is estimated via a data-driven method using a transfer factor between the distributions which fail and pass the two-pronged substructure requirement. The new physics signal is searched for as a narrow peak excess above the Standard Model backgrounds in the jet mass spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search For Low-Mass Quark-Antiquark Resonances Produced With an Initial State Photon at 13 TeV Using the CMS Detector

We present a search for low-mass narrow qq̅ resonances. This search uses data from LHC pp collisions at a center of mass of 13 TeV in Run 2, and corresponds to an integrated luminosity of 137 fb^{-1}, currently using 10\% of data. Utilizing full Run 2 data allows the use of a lower photon pT threshold trigger than a previous analysis performed with only 2016 data, allowing this analysis to be more sensitive to resonances in the low mass region. We require an initial state photon recoiling against the narrow resonance, leading to the resonance having a high transverse momentum. The high pT decay products of the resonance collimate and are reconstructed as a single large jet with an internal two-pronged substructure. A two-pronged dijet score based on the ParticleNet tagger is used to select jets with two-pronged substructure. The background is estimated via a data-driven method using a transfer factor between the distributions which fail and pass the two-pronged substructure requirement. The new physics signal is searched for as a narrow peak excess above the Standard Model backgrounds in the jet mass spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of High-Performance Photon-Number-Resolving Photodetectors Based on Coherently Interacting Nanoscale Elements

A number of applications in basic science and technology would benefit from high-fidelity photon-number-resolving photodetectors. While some recent experimental progress has been made in this direction, the requirements for true photon number resolution are stringent, and no design currently exists that achieves this goal. Here we employ techniques from fundamental quantum optics to demonstrate that detectors composed of subwavelength elements interacting collectively with the photon field can achieve high-performance photon number resolution. We propose a new design that simultaneously achieves photon number resolution, high efficiency, low jitter, low dark counts, and high count rate. Finally, we discuss specific systems that satisfy the design requirements, pointing to the important role of nanoscale device elements.

47 OTHER INSTRUMENTATION↗

Hard X-ray Fluorescence measurements with TESs at the Advanced Photon Source

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20keV energy range. We are building a TES-based instrument for time Advanced Photon Source (APS) synchrotron, to be made available to beamline users. 24-pixel prototype arrays have recently been fabricated and tested. the first, spectroscopy measurements using these arrays are promising, with a best single-pixel energy resolution of 11.2 eV and saturation energy > 20 keV. We present a series of recent X-ray Fluorescence measurements involving transition metal elements and multi-element samples with closely spaced emission lines, in particular a Cu-Ni-Co thin film and a foil of Cu and Hf, The TES-measured spectra are directly compared to spectra measured with silicon drift detectors at an APS beamline, demonstrating the improved X-ray science made possible by TES spectrometers.

Guruswamy, Tejas↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Search for Isoscalar Resonances in yp ¿ wnp AT GLUEX

The GlueX experiment has produced the world?s largest statistics for peripheral photoproduction of mesons with a goal to search for exotic mesons. This document presents results on the search for possible intermediate resonances which decay to ??. Little is known for the states seen in this decay channel such as the ?(1420) and ?(1650). This channel also allows to search for the never seen exotics JPC = 0??, 2+?, and the elusive 2??. The ?, in this reaction, is identified via the ?+???0 decay mode and the ? and ?0 are identified via the decay to 2?. Data from the GlueX Phase I was analyzed. This data was obtained at the Thomas Jefferson National Accelerator Facility utilizing the GlueX detector and a tagged linearly polarized photon beam incident on a liquid hydrogen target. A model using the expected major wave contributors, 1+? and 1??, shows two structure in the region where the ?(1420) and ?(1650) are expected. A third structure is seen at threshold with the quantum numbers of an h1 resonance, however, more studies are needed to assert the nature of this structure. Instabilities on the m = ±1 were shown to come from mathematical ambiguities. This only occurs between the m = 1 and m = ?1 projections when both reflectivities are present in close amount. Expanding the intensity equation for a single wave allows to extract coefficients that can help describe the data. A tangent study is also presented in this document which consists on a direct fit to the lineshape of an isolated N(1535). This baryonic resonance is well established, but its Breit-Wigner parameters have only been obtained from partial wave analysis. In contrast, this study obtained the Breit-Wigner parameters using a direct fit and finds the value of the width to be 70.5± 9.2 MeV; this is half of the accepted value.

Barriga, Edmundo↗

X-ray Response of the Fully-Depleted, p-Channel SiSeRO-CCD

We present an X-ray characterization of a fully depleted, 725 $μ$m thick p-channel SiSeRO CCD. Measurements with a $^{55}$Fe source yield an energy resolution of $54 \pm 0.9$ eV ($14.6 \pm 0.25 e^{-}$) at 5.9 keV for single-pixel events, demonstrating that the SiSeRO amplifier preserves the intrinsic charge resolution of the CCD under multi-sample non-destructive readout. Characterization with a $^{241}$Am source extends the response to higher-energy photons, with reconstructed spectral features observed between 9-26 keV and the 59.5 keV $γ$ emission. These measurements, together with a muon-derived diffusion calibration, show that charge transport and diffusion are consistent with interactions spanning the full sensor depth. These results demonstrate that the SiSeRO CCD simultaneously achieves sub-electron noise performance and efficient charge collection in a thick, fully depleted silicon detector. This combination enables X-ray spectroscopy across a broad energy range while maintaining sensitivity to faint signals.

Cuevas-Zepeda, Julian↗

Background studies and normalization of signal events in the Mu2e experiment

The Mu2e experiment is currently being constructed at Fermilab to search for the neutrino-less conversion of negative muons into electrons in the field of an aluminum nucleus. The experiment aims at a sensitivity of four orders of magnitude higher than previous related experiments, which implies highly demanding accuracy requirements both in the design and during the operation. To achieve such a goal, two important tasks should be accomplished. First, it is essential to estimate precisely the particle yields and all the backgrounds that could mimic the monoenergetic conversion electron signal. Second, it is necessary to normalize the signal events accurately. The normalization of the signal events is planned to be done using a detector system made of an HPGe detector and a Lanthanum Bromide detector, which will measure the rate of muons stopped on the aluminum target by looking at the emitted characteristic X-and γ-rays of energies up to 1809 keV. Therefore, it is essential to evaluate the detector system's performance before the start of the actual experiment. In this study, the first task was addressed by an extensive campaign of Monte Carlo simulations to investigate the relevant parameters and their impact on the experiment's sensitivity. The second task was handled by taking advantage of the Helmholtz-Zentrum Dresden-Rossendorf (HZDR) pulsed Bremsstrahlung photon beam at the ELBE facility. The detector system was tested at the ELBE facility under timing and background conditions similar to the ones expected at the Mu2e experiment. The study presents and discusses the simulation results and the detector system testing campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

areaDetector/ADTimePix3

ADTimePix3 is an open‑source EPICS areaDetector driver for TimePix3 pixel detectors from Advanced Scientific Instruments (ASI). It provides a complete control and data‑acquisition interface between EPICS and the Serval server, supporting both real detectors (single‑chip and 2×2 quad configurations) and the TimePix3 emulator. The driver configures measurements via an HTTP/JSON REST API and acquires data through high‑rate TCP streams for raw events, images, and histograms. It offers real‑time preview and accumulated images, Time‑of‑Flight histogram processing, pixel masking (including Binary Pixel Configuration files and hot‑pixel tools), extensive health and status monitoring, and integration with standard areaDetector plugins for file saving and downstream analysis. ADTimePix3 is designed for Linux 64‑bit systems (tested on Ubuntu and RHEL) and is distributed under an MIT license with additional institutional disclaimers, enabling reuse and extension in photon science beamlines and other TimePix3‑based experimental facilities.

Gofron, Kaz↗

Measurement of the Higgs boson mass with H → γγ decays in 140 fb –1 of $\sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector

The mass of the Higgs boson is measured in the H→γγ decay channel, exploiting the high resolution of the invariant mass of photon pairs reconstructed from the decays of Higgs bosons produced in proton–proton collisions at a centre-of-mass energy $\sqrt{s}$ = 13 TeV. The dataset was collected between 2015 and 2018 by the ATLAS detector at the Large Hadron Collider, and corresponds to an integrated luminosity of 140 fb –1 . The measured value of the Higgs boson mass is 125.17 ± 0.11(stat.) ± 0.09(syst.) GeV and is based on an improved energy scale calibration for photons, whose impact on the measurement is about four times smaller than in the previous publication. A combination with the corresponding measurement using 7 and 8 TeV pp collision ATLAS data results in a Higgs boson mass measurement of 125.22 ± 0.11(stat.) ± 0.09(syst.) GeV. With an uncertainty of 1.1 per mille, this is currently the most precise measurement of the mass of the Higgs boson from a single decay channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low voltage AC electroluminescence in silicon MOS capacitors

Low power silicon based light source and detector are attractive for on-chip photonic circuits given their ease of process integration. However, conventional silicon light emitting diodes emit photons with energies near the band edge where the corresponding silicon photodetectors lack responsivity. On the other hand, previously reported hot carrier electroluminescent silicon devices utilizing a reverse biased diode require high operating voltages. Here, we investigate hot carrier electroluminescence in silicon metal–oxide–semiconductor capacitors operating under transient voltage conditions. Further, during each voltage transient, large energy band bending is created at the edge of the source contact, much larger than what is achievable at a steady state. As a result, electrons and holes are injected efficiently from a single source contact into the silicon channel at the corresponding voltage transient, where they subsequently undergo impact ionization and phonon-assisted interband recombination. Notably, we show low voltage operation down to 2.8 V by using a 20 nm thick high-κ gate dielectric. We show further voltage scaling is possible by reducing the gate dielectric thickness, thus presenting a low voltage platform for silicon optoelectronic integrated circuits.

42 ENGINEERING↗

Photon Frequency Conversion in High-Q Superconducting Resonators: Axion Electrodynamics, QED, and Nonlinear Meissner Radiation

High-Q superconducting resonators have been proposed and developed as detectors of light-by-light scattering mediated by the hypothesized axion or virtual electron–positron pairs in quantum electrodynamics: the Euler–Heisenberg (EH) interaction. Photon frequency and mode conversion is central to the scheme for detecting such rare events. Superconducting resonators are nonlinear devices. The Meissner screening currents that confine the electromagnetic fields to the vacuum region of a superconducting RF cavity are nonlinear functions of the EM field at the vacuum–superconducting interface, and as a result can generate source currents and frequency conversion of microwave photons in the cavity. In this report we consider photon frequency and mode conversion in superconducting resonators with high quality factors from Meissner currents in single- and dual-cavity setups proposed for axion and QED searches based on light-by-light scattering. In a single cavity with two pump modes, photon frequency conversion by the Meissner screening current dominates photon generation by the EH interaction for cavities with Q≲1012⁠. The Meissner currents also generate background photons that limit the operation of the resonator for axion detection in three-mode, single-cavity setups. We also consider the leakage of photons from pump modes into the signal mode for both axion- and EH-mediated light-by-light scattering. Photon frequency conversion by the EH interaction can compete with Meissner and leakage radiation in ultra-high-Q cavities that are beyond the current state of the art. Meissner radiation and leakage backgrounds can be suppressed in dual-cavity setups with appropriate choices for pump and spectator modes, as well as the single-cavity setup proposed for heterodyne detection of galactic axion dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposal for broad-range directional detection of light dark matter in cryogenic ice

We propose hexagonal ice (H 2 ⁡O) as a new target for light dark matter (DM) direct detection. Ice, a polar material, is suitable for single phonon detection through DM scattering for which we consider light dark photon and light scalar mediator models. We report a rate sensitivity down to a DM mass of ~keV, constituting a broader mass range than other promising candidates. We find better sensitivity for near-term experimental thresholds from the presence of high-frequency phonons. These advantages, and ice’s availability, make it highly promising for single-phonon detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION↗

First results from a multiplexed and massive instrument with sub-electron noise Skipper-CCDs

Here, we present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, 1.35 Mpix sensors, from a new foundry, are glued into a Multi-Chip Module (MCM) printed circuit board on a ceramic substrate which has 16 sensors each. The instrument, that can hold up-to 16 MCMs, a total of 256 Skipper-CCD sensors (called a Super-Module with ≈ 130 grams of active mass and 346 Mpix), is part of the R&D effort of the OSCURA experiment which will have ≈ 94 super-modules. Experimental results with 10 MCMs and 160 Skipper-CCDs sensors are presented in this paper. This is already the largest ever built instrument with single electron sensitivity CCDs using nondestructive readout, both, in terms of active mass and number of channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DENNIS: a design and analysis tool for dynamic material x-ray diffraction experiments

We present DENNIS (Diffraction Experiment desigN and aNalysiS): a graphical software tool useful for the design and analysis of dynamic x-ray diffraction experiments, such as those performed on the Z Pulsed Power Facility, Thor Pulsed Power Generator, and Dynamic Compression Sector (DCS) of the Advanced Photon Source. DENNIS provides rapid powder and single-crystal diffraction pattern predictions and powder diffraction pattern image integration in three-dimensional geometries. Additional features include crystallographic information file reading, image processing, and synthetic diffraction pattern image generation. We overview the software's capabilities, detail the prediction and integration methodologies, and provide example implementations on Z and DCS experiments.

47 OTHER INSTRUMENTATION↗