Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Polarizing 3 He via metastability exchange optical pumping using a 1.2 mbar sealed cell at magnetic fields up to 5 T

Here, we report high nuclear polarization of 1.2 mbar 3 He gas in a sealed cell in magnetic fields up to 5 T using Metastability Exchange Optical Pumping (MEOP). The creation of a highly polarized 3 He gas target for use in the 5 T field of Jefferson Lab’s CLAS12 spectrometer would enable new studies of spin-dependent asymmetries on the neutron. We describe a systematic study which was conducted for the first time up to the full 5 T field required for the final target design to evaluate the effects of discharge intensity, pump laser power, and optical pumping transition schemes on nuclear polarization and pumping rates. Steady-state polarizations up to 86% in magnetic fields between 2 and 5 T were achieved, with a discharge-on relaxation time of 898 s at 5 T. These results underscore the potential of MEOP for high-field applications in nuclear physics experiments.

3He polarization↗

Design and commissioning of readout electronics for a $K$$^{0}_{L}$ and $μ$ detector at the Belle II experiment

The K-long and muon detector (KLM) constitutes the outer-most volume of the Belle II spectrometer at the interaction region of the SuperKEKB collider in Tsukuba, Japan. The KLM detector was partially upgraded since the Belle experiment by replacing many of its resistive-plate chambers with scintillators containing wavelength-shifting fibers and instrumenting it with silicon photomultipliers. Here, we describe the readout electronics, firmware, and software created to control and acquire data from the scintillators and resistive-plate chambers.

Belle II↗

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

Optimizing a detection system for fissile material in nuclear disarmament verification

In arms control treaties, verification plays a crucial role in detecting non-compliance, deterring future violations, and building trust between state parties. Neutron interrogation that induces fission reactions in fissile isotopes and measures the resulting fission neutrons, could be employed for this purpose. This study aims to develop a system which can determine the presence of fissile material while intrinsically protecting information. In this paper, we focus on optimizing the system for discriminating between an enriched uranium block from a depleted uranium (DU) block. The system was built and we report on benchmark measurements with DU and 16% enriched uranium blocks. Furthermore, the Excalibur (Experiment for Calibration with Uranium) neutron source, a neutron spectrometer (redBubble Technology Industries (BTI) N-Probe), and superheated droplet detectors were used for these measurements. MCNP simulations provided insights into detector responses to fissile materials with varying isotopic compositions, confirming that the system functioned as designed.

Active neutron interrogation↗

A novel, steerable, low-energy proton source for detector characterization

We report on the conversion of the Manitoba II mass spectrometer into a versatile low-energy proton beam facility. This infrastructure is adaptable to any detector-under-test (DUT), and has proven itself effective with the characterization of silicon detectors used in subatomic beyond-the-Standard-Model (BSM) searches, namely the Nab experiment. A pencil beam of mono-energetic protons can be produced in a range from 25 keV to 35 keV, achieving a beam current of ~1 x 10 -18 A. Electrostatic steering plates were constructed to direct the Gaussian-profile proton beam over a 117 mm diameter area-of-interest with full-width at half-maxima (FWHM) ranging from 0.6 mm to 1.26 mm. This work discusses the modifications and subsequent tests to confirm the beam specifications met the demands of the aforementioned detectors.

Fundamental neutron physics↗

The MUSE Target Chamber Post Veto

The Muon Scattering Experiment (MUSE) was developed to address the proton radius puzzle through simultaneous electron–proton and muon-proton scattering using the Paul Scherrer Institute’s πM1 secondary beamline. MUSE uses a large-solid-angle, non-magnetic spectrometer to detect beam particles scattering from a liquid hydrogen cell contained within a vacuum chamber. Due to the large scattering windows, the structural integrity of the chamber is supported by posts located at small scattering angles. While out of the acceptance, particles in the tails of the beam distribution can strike these posts, causing a significant trigger background. We describe the design and performance of the Target Chamber Post Veto (TCPV) detector installed inside the vacuum chamber to remove these background events at the trigger level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of nitrogen molecular breakup on divertor conditions in JET L-mode plasmas using SOLPS-ITER

SOLPS-ITER simulations of nitrogen-seeded, low-confinement mode plasmas in the Joint European Torus (JET) predict that the electron temperature in the low-field side (LFS) divertor leg is reduced locally by up to an order of magnitude when nitrogen is assumed to recycle as molecules (N 2 ) instead of atoms using a fixed nitrogen injection rate. The LFS divertor temperature reduction under the assumption of molecular recycling occurs due to a three-step mechanism: (1) the plasma penetration of nitrogen atoms is increased due to the strong triple bond of the N 2 molecule and the kinetic energy release in the dissociation event, both mechanisms contributing equally, (2) the abundance of (particularly multiply-charged) nitrogen ions in the divertor is increased and (3) the electron temperature is reduced due to the increase in radiation (by up to a factor of 4) from nitrogen ions. Setting the volume-integrated nitrogen radiated power to a constant value (0.6 MW) instead of the nitrogen injection rate, SOLPS-ITER predicts under the molecular nitrogen recycling assumption that the peak line-integrated N II, N III and N IV intensities in the LFS divertor are approximately within 15%, 35% and 5%, respectively, of the reference atomic nitrogen recycling case. The predicted peak N II, N III and N IV intensities under either assumption are within 30%, 65% and 5%, respectively, of measurements using the vertically viewing mirror-link divertor spectrometer (Meigs et al., 2010) in nitrogen-seeded JET L-mode plasmas (Lomanowski et al., 2019). ERO2.0 simulations using a constant nitrogen seeding rate on static background plasma solutions from EDGE2D-EIRENE (previously presented in Mäenpää et al., (2022), revised here to include fast reflections) predict that N II to N IV line emission is increased by 20% to 30% when nitrogen is assumed to recycle as molecules, demonstrating the importance of considering the effect of molecular dissociation reactions on the divertor plasma in a self-consistent manner.

Divertor↗

Temperature-dependent optical constants of vanadium dioxide thin films deposited on polar dielectrics

Coating polar dielectrics with thin film vanadium dioxide (VO 2 ) enables one to exploit the temperature-dependent phase transition within VO 2 to actively tune and modulate surface phonon polaritons at mid-infrared. However, controlling the behavior of such systems requires intimate knowledge of the temperature-dependent optical constants of VO 2 , which depend greatly on the growth conditions and substrate material. Here, in this work, we accurately determine the complex optical constants of VO 2 on polar dielectrics across the insulator-to-metal phase transition (IMT) using only normal incident reflectance spectra by analyzing the reflectance with Kramers–Kronig relations and thin film Fresnel equations. This non-ellipsometry technique offers an advantage in determining the refractive index using a standard infrared spectrometer.

36 MATERIALS SCIENCE↗

Evolution of the nuclear spin-orbit splitting explored via the 32 Si( d,p ) 33 Si reaction using SOLARIS

The spin-orbit splitting between neutron 1p orbitals at 33 Si has been deduced using the single-neutron-adding (d,p) reaction in inverse kinematics with a beam of 32 Si, a long-lived radioisotope. Reaction products were analyzed by the newly implemented SOLARIS spectrometer at the reaccelerated-beam facility at the National Superconducting Cyclotron Laboratory. The measurements show reasonable agreement with shell-model calculations that incorporate modern cross-shell interactions, but they contradict the prediction of proton density depletion based on relativistic mean-field theory. The evolution of the neutron 1p-shell orbitals is systematically studied using the present and existing data in the isotonic chains of N = 17, 19, and 21. In each case, a smooth decrease in the separation of the 1p 3/2 - 1p 1/2 orbitals is seen as the respective p-orbitals approach zero binding, suggesting that the finite nuclear potential strongly influences the evolution of nuclear structure in this region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for axion-like particles through nuclear Primakoff production using the GlueX detector

We report on the results of the first search for the production of axion-like particles (ALPs) via Primakoff production on nuclear targets, γA → aA, in the “SRC-CT” experiment using the GlueX detector at Jefferson Lab. This search uses an integrated luminosity of 100 pb -1 nucleon on a 12 C target with a real photon beam of energies 6 < E γ < 10.8 GeV, and explores the mass region of 200 < m a < 450 MeV via the decay a → γγ. This mass range is between the π 0 and η meson masses, which enables the use of the measured η meson production rate to obtain absolute bounds on the ALP production with reduced sensitivity to experimental luminosity and detection efficiency. We find no evidence for an ALP, consistent with previous searches in the quoted mass range, and present limits on the effective photon coupling scale of $\mathscr{O}$(1 TeV -1 ). We further find that the ALP production limit we obtain is hindered by the peaking structure of the non-target-related dominant background the in GlueX spectrometer, which we treat by using data on 4 He to estimate and subtract it. We comment on how this search can be improved in a future higher-statistics dedicated measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise mass measurements of A = 133 isobars with the Canadian Penning Trap: Resolving the Q β − anomaly at 133Te

We report precision mass measurements of 133 Sb 133g,m Te, and 133g,m I, produced at CARIBU at Argonne National Laboratory's ATLAS facility and measured using the Canadian Penning Trap mass spectrometer. These masses clarify an anomaly in the 133 Te β-decay. The masses reported in the 2020 Atomic Mass Evaluation (M. Wang et al., 2021) produce Q B - ( 133 Te)=2920(6) keV; however, the highest-lying 133 I level populated in this decay is observed at E i = 2935.83(15) keV, resulting in an anomalous Q$^i_B-$ = -16(6)keV. Our new measurements give Q B - ( 133 Te)=2934.8(11) keV, a factor of five more precise, yielding Q$^i_B$ = -1.0(12) keV, a 3σ shift from the previous results. This resolves this anomaly, but indicates further anomalies in our understanding of the structure of this isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flavor Dependence of Charged Pion Fragmentation Functions

We have measured the flavor dependence of multiplicities for π + and π - production in semi-inclusive deep-inelastic scattering (SIDIS) on proton and deuteron to explore a possible charge symmetry violation in fragmentation functions. The experiment used an electron beam with energies of 10.2 and 10.6 GeV at Jefferson Lab and the Hall-C spectrometers. The electron kinematics spanned the range 0.3 < x < 0.6, 2 < Q 2 < 5.5 GeV2, and 2.2 < W < 3.2 GeV. The pion fractional momentum range was 0.3 < z < 0.7, and the transverse momentum range was 0 < p T < 0.25 GeV/c. Assuming factorization and allowing for isospin breaking, the results can be described by two “favored” and two “unfavored” effective low p T fragmentation functions that are flavor-dependent. We find each pair converges to a common flavor-independent fragmentation function at the highest W, where factorization is most applicable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing hard/soft factorization via beam-spin asymmetry in exclusive pion electroproduction from the proton

Deep exclusive meson production (DEMP) reactions, such as $p(\vec{e}, e' π^+)n$, provide opportunities to study the three-dimensional structure of the nucleon through differential cross section and beam- and target-spin asymmetry measurements. This work aims to probe the onset of the hard/soft factorization regime through the exclusive $p(\vec{e}, e' π^+)n$ reaction, as measured in the KaonLT experiment at Jefferson Lab Hall C. A 10.6 GeV longitudinally polarized electron beam was incident on an unpolarized liquid hydrogen target, and the scattered electron and produced meson were detected in two magnetic focusing spectrometers, enabling precision cross section measurements. The cross section ratio $σ_{LT'}/σ_0$ was extracted from the beam-spin asymmetry $A_{LU}$. The t -dependence of $σ_{LT'}/σ_0$ was determined at fixed $Q^2$ and $x_B$ over a range of kinematics from 2 < $Q^2$ < 6 GeV$^2$ above the resonance region ($W$ > 2 GeV). Furthermore, these data are combined with recent results from CLAS/CLAS12 to determine the $Q^2$-dependence of at two $(x_B, t)$ settings. This was fairly flat, with $Q^2$ not having a measurable effect on the value of in the range explored. Results are compared to predictions from the generalized parton distribution (GPD) formalism, which relies explicitly on hard/soft factorization, and Regge formalism. The Regge models better predict $σ_{LT'}/σ_0$, which suggests that the factorization regime is not yet reached.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First measurement of polarized spin-density matrix elements and differential cross sections dσ/dt in ω photoproduction off the proton for 2.7 < Eγ < 5.2 GeV using CLAS at Jefferson Lab

We report on the differential cross sections dσ/dt, the unpolarized spin-density matrix elements ρ 00 0 , ρ 1 − 1 0 , Re ρ 10 0 , and the first extraction of the polarized elements Im ρ 10 3 , Im ρ 1 − 1 3 for the reaction γp → pω using the CLAS spectrometer at Jefferson Laboratory. The ω mesons were detected in their dominant charged decay mode, ω → π + π − π 0 , and all t-dependent results are presented in a fine binning for incident photon energies between 2.73 and 5.16 GeV (corresponding to the center-of-mass energy range W ∈ [ 2.45, 3.25 ] GeV). All matrix elements are first measurements for − t > 0.6 GeV2. Moreover, differential cross sections dσ/d(cos Θ c . m . ω ) and the corresponding angle-dependent unpolarized spin-density matrix elements in the Adair frame are presented for the incident photon energy range 1.56–3.80 GeV (corresponding to W ∈ [ 1.95, 2.83 ] GeV). These new ω photoproduction data are consistent with earlier CLAS results but extend the energy range well beyond the nucleon resonance region into the Regge regime. The comparison with Regge-theory-based model predictions shows that the new data impose more stringent constraints on our understanding of ω photoproduction.

Hu, T.↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗