Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator test facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Large dynamic range diagnostics for high current electron LINACs

The Jefferson Lab FEL driver accelerator - Energy Recovery Linac has provided a beam with average current of up to 9 mA and beam energy of 135 MeV. The high power beam operations have allowed developing and testing methods and approaches required to set up and tune such a facility simultaneously for the high beam power and high beam quality required for high performance FEL operations. In this contribution we briefly review this experience and outline problems that are specific to high current - high power non-equilibrium linac beams. While the original strategy for beam diagnostics and tuning have proven to be quite successful, some shortcomings and unresolved issues were also observed. The most important issues are the non-equilibrium (non-Gaussian) nature of the linac beam and the presence of small intensity - large amplitude fraction of the beam a.k.a. beam halo. Thus we also present a list of the possible beam halo sources and discuss possible mitigations means. We argue that for proper understanding and management of the beam halo large dynamic range (>10{sup 6}) transverse and longitudinal beam diagnostics can be used. We also present results of transverse beam profile measurements with the dynamic range approaching 10{sup 5} and demonstrate the effect the increased dynamic range has on the beam characterization, i.e., emittance and Twiss parameters measurements. We also discuss near future work planned in this field and where the JLab FEL facility will be used for beam tests of the developed of new diagnostics.

43 PARTICLE ACCELERATORS↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

DOSECALCX, A Bremsstrahlung Radiation Dose Code for Electron Beam Targets

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility is a two-axis, linear induction electron accelerator designed to produce Bremsstrahlung radiation for imaging hydrodynamic physics within rapidly compressed targets. The radiation dose code DOSECALC, used to obtain approximate results for experiments, was modified to include new materials and renamed DOSECALCX. Calculations were compared with results from the MCNP code. Photon spectra was found to agree visibly and quantitatively while angular dose data was only comparable within an order of magnitude.

43 PARTICLE ACCELERATORS↗

DARHT Axis 1 Time-Resolved Injector Energy Measurement

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injected electron beam energy. The DARHT Axis 1 injector of produces a 3-4 MeV, 1-2 kA, 80-ns-FWHM electron beam. Injector capacitive monitors (EVACSUM) are summed to give the injector beam energy. Calibration of EVACSUM was last done in 1999 and is needed. In addition, the flatness of the injector drive voltage is controlled by a peaking capacitor in a Blumlien that is charged by the prime power tank. Time resolved measurements are used to optimize the value of this capacitor.

47 OTHER INSTRUMENTATION↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

A Human Factors Evaluation of a Methodology for Pressurized Crew Module Acceptability for Zero-Gravity Ingress of Spacecraft

This project aimed to develop a methodology for evaluating performance and acceptability characteristics of the pressurized crew module volume suitability for zero-gravity (g) ingress of a spacecraft and to evaluate the operational acceptability of the NASA crew return vehicle (CRV) for zero-g ingress of astronaut crew, volume for crew tasks, and general crew module and seat layout. No standard or methodology has been established for evaluating volume acceptability in human spaceflight vehicles. Volume affects astronauts'ability to ingress and egress the vehicle, and to maneuver in and perform critical operational tasks inside the vehicle. Much research has been conducted on aircraft ingress, egress, and rescue in order to establish military and civil aircraft standards. However, due to the extremely limited number of human-rated spacecraft, this topic has been un-addressed. The NASA CRV was used for this study. The prototype vehicle can return a 7-member crew from the International Space Station in an emergency. The vehicle's internal arrangement must be designed to facilitate rapid zero-g ingress, zero-g maneuverability, ease of one-g egress and rescue, and ease of operational tasks in multiple acceleration environments. A full-scale crew module mockup was built and outfitted with representative adjustable seats, crew equipment, and a volumetrically equivalent hatch. Human factors testing was conducted in three acceleration environments using ground-based facilities and the KC-135 aircraft. Performance and acceptability measurements were collected. Data analysis was conducted using analysis of variance and nonparametric techniques.

Sanchez, Merri J.↗

The use of aluminum nitride to improve Aluminum-26 Accelerator Mass Spectrometry measurements and production of Radioactive Ion Beams

We present results and discuss the use of aluminum nitride as a promising source material for Accelerator Mass Spectrometry (AMS) and Radioactive Ion Beams (RIBs) science applications of 26 Al isotopes. The measurement of 26 Al in geological samples by AMS is typically conducted on Al 2 O 3 targets. However, Al 2 O 3 is not an ideal source material because it does not form a prolific beam of Al- required for measuring low-levels of 26 Al. Multiple samples of aluminum oxide (Al 2 O 3 ), aluminum nitride (AlN), mixed Al 2 O 3 –AlN as well as aluminum fluoride (AlF 3 ) were tested and compared using the ion source test facility and the stable ion beam (SIB) injector platform at the 25-MV tandem electrostatic accelerator at Oak Ridge National Laboratory. Negative ion currents of atomic and molecular aluminum were examined for each source material. It was found that pure AlN targets produced substantially higher beam currents than the other materials and that there was some dependence on the exposure of AlN to air. The applicability of using AlN as a source material for geological samples was explored by preparing quartz samples as Al 2 O 3 and converting them to AlN using a carbothermal reduction technique, which involved reducing the Al 2 O 3 with graphite powder at 1600 °C within a nitrogen atmosphere. The quartz material was successfully converted to AlN. Thus far, AlN proves to be a promising source material and could lead towards increasing the sensitivity of low-level 26 Al AMS measurements. The potential of using AlN as a source material for nuclear physics is also very promising by placing 26 AlN directly into a source to produce more intense radioactive beams of 26 Al.

Janzen, Meghan S.↗

Accelerator Technology Magnets

The Snowmass community exercise started in April 2020 to identify and document a scientific vision for the future of particle physics in the US and international partners. The AF7-Magnets working group was charged to a) address the potential contributions of magnet technology to future HEP facilities, b) evaluate the R&D required to enable these opportunities, c) estimate the time and cost scales of these efforts, and d) assess the needs for associated fabrication infrastructure and test facilities. This report addresses the working group charge, summarizes the status of accelerator and detector magnet technologies, and discuss ideas and plans to push this key area of the US and international HEP to new horizons.

43 PARTICLE ACCELERATORS↗

Record high-gradient SRF beam acceleration at Fermilab

Here, many modern and future particle accelerators employ high gradient superconducting RF (SRF) to generate beams of high energy, high intensity and high brightness for research in high energy and nuclear physics, basic energy sciences, etc. In this paper we report the record performance large-scale SRF system with average beam accelerating gradient matching the International Linear Collider (ILC) specification of 31.5 MV m –1 . Design of the eight cavity 1.3 GHz SRF cryomodule, its performance without the beam and results of the system commissioning with high intensity electron beam at Fermilab Accelerator Science and Technology (FAST) facility are presented. We also briefly discuss opportunities for further beam studies and tests at FAST including those on even higher gradient and more efficient SRF acceleration, as well as exploration of the system performance with full ILC-type beam specifications.

43 PARTICLE ACCELERATORS↗

Studies as a function of different ALD capping layers on cavity losses for QIS and accelerators

Niobium-based bulk SRF cavities have demonstrated exceptional performance. To further improve niobium cavity performance, we present studies involving a novel surface engineering process designed to prevent the formation of amorphous niobium oxides on the surface. This is achieved by encapsulating the niobium surface using thermal Atomic-Layer-Deposition (ALD). This technique has been shown to enhance the properties of niobium cavities and 2D resonators. This study not only aims to improve SRF performance at high fields but also has the potential to enhance the quality factor in low-field regimes, particularly for quantum applications. For the method to be effective, it is essential to have a clean interface between the encapsulating layer and the bulk niobium. Achieving this requires a uniform coating across the entire cavity surface and efficient removal of the underlying niobium oxides. To optimize the process, a variety of material characterization tools have been utilized to refine parameters such as thin film thickness and annealing conditions. Cavity RF measurements were performed at the vertical test facilities at FNAL to assess the Q vs. Eacc curves for accelerator applications, as well as at the SQMS dilution refrigerators to investigate the full two-level system (TLS) losses at milliKelvin and single-photon levels. Based on the results, we characterized the loss of different oxides in various regimes and applications, comparing them to natural niobium pentoxide.

Grassellino, L. [Fermilab]↗

IOTA Proton Injector Beamline Installation

The IOTA Proton Injector (IPI), currently under installation at the Fermilab Accelerator Science and Technology facility, is a beamline capable of delivering 20-mA pulses of protons at 2.5 MeV to the Integrable Optics Test Accelerator (IOTA) ring. First beam in the IPI beamline is anticipated in 2023, when it will operate alongside the existing electron injector beamline to facilitate further fundamental physics research and continued development of novel accelerator technologies in the IOTA ring. This report details the expected operational profile, known challenges, and the current state of installation.

43 PARTICLE ACCELERATORS↗

Corrosion impact of reductant on DWPF and downstream facilities

Glycolic acid is being evaluated as an alternate reductant in the preparation of high level waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid is not completely consumed and small quantities of the glycolate anion are carried forward to other high level waste (HLW) facilities. The impact of the glycolate anion on the corrosion of the materials of construction throughout the waste processing system has not been previously evaluated. A literature review had revealed that corrosion data in glycolate-bearing solution applicable to SRS systems were not available. Therefore, testing was recommended to evaluate the materials of construction of vessels, piping and components within DWPF and downstream facilities. The testing, conducted in non-radioactive simulants, consisted of both accelerated tests (electrochemical and hot-wall) with coupons in laboratory vessels and prototypical tests with coupons immersed in scale-up and mock-up test systems. Eight waste or process streams were identified in which the glycolate anion might impact the performance of the materials of construction. These streams were 70% glycolic acid (DWPF feed vessels and piping), SRAT/SME supernate (Chemical Processing Cell (CPC) vessels and piping), DWPF acidic recycle (DWPF condenser and recycle tanks and piping), basic concentrated recycle (HLW tanks, evaporators, and transfer lines), salt processing (ARP, MCU, and Saltstone tanks and piping), boric acid (MCU separators), and dilute waste (HLW evaporator condensate tanks and transfer line and ETF components). For each stream, high temperature limits and worst-case glycolate concentrations were identified for performing the recommended tests. Test solution chemistries were generally based on analytical results of actual waste samples taken from the various process facilities or of prototypical simulants produced in the laboratory. The materials of construction for most vessels, components and piping were not impacted with the presence of glycolic acid or the impact is not expected to affect the service life. However, the presence of the glycolate anion was found to affect corrosion susceptibility of some materials of construction in the DWPF and downstream facilities, especially at elevated temperatures. The following table summarizes the results of the electrochemical and hot wall testing and indicates expected performance in service with the glycolate anion present.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CLAS12 Silicon Vertex Tracker Module Test

This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory and the experimenters of CLAS12 collaboration who have committed to participate in beam tests to be carried out during the 2013-2014 Fermilab Test Beam Facility program.

43 PARTICLE ACCELERATORS↗

Status and Planned Experiments of the Hiradmat Pulsed Beam Material Test Facility at CERN SPS

HiRadMat (High Irradiation to Materials) is a facility at CERN designed to provide high-intensity pulsed beams to an irradiation area where material samples as well as accelerator component assemblies (e.g. vacuum windows, shock tests on high power targets, collimators) can be tested. The beam parameters (SPS 440 GeV protons with a pulse energy of up to 3.4 MJ, or alternatively lead/argon ions at the proton equivalent energy) can be tuned to match the needs of each experiment. It is a test area designed to perform single pulse experiments to evaluate the effect of high-intensity pulsed beams on materials in a dedicated environment, excluding long-time irradiation studies. The facility is designed for a maximum number of 1016 protons per year, in order to limit the activation of the irradiated samples to acceptable levels for human intervention. This paper will demonstrate the possibilities for research using this facility and go through examples of upcoming experiments scheduled in the beam period 2015/2016.

43 PARTICLE ACCELERATORS↗

Fermilab Testbeam Facility Annual Report – FY 2016

This Technical Memorandum (TM) summarizes the Fermilab Test Beam operations for FY 2015. It is one of a series of annual publications intended to gather information in one place. In this case, the information concerns the individual experiments that ran at FTBF, which are tabulated. Each experiment section was prepared by the relevant authors, and was edited for inclusion in this summary.

43 PARTICLE ACCELERATORS↗

Efficacy and Delivery of Novel FAST Agents for Coronaviruses

We proposed to test and develop advanced delivery for novel agents from our collaborators Facile Accelerated Specific Therapeutics (FAST) platform to reduce coronavirus replication. Sachi Bioworks Inc., Prof. Anushree Chatterjee, and Prof. Prashant Nagpal at the University of Colorado Boulder have developed a bioinformatics and synthesis pipeline to produce sequence specific theranostic agents (agents that can be therapies and/or diagnostics) that are inherently transported into the cytoplasm of mammalian host cells and sequence-specifically interfere in nucleic acid replication. The agent comprises a small nanoparticle (2-5 nm) chosen for ideal cellular transport and/or imaging conjugated to a short, synthetic DNA analog oligomer designed for binding to one or more target viral sequences. The sequence specific binding of the FAST agent to its target prevents nucleic acid replication due to its high affinity binding. While the small nanoparticle facilitates delivery in vitro, we plan to package the FAST agents into a larger nanoparticle (80-300 nm) for future in vivo delivery applications. Our team at Sandia has expertise encapsulating biomolecules including protein, DNA, and RNA into solid lipid nanoparticles (LNP) and lipid coated mesoporous silica nanoparticles (LC-MSN) and shown successful delivery in mouse models to multiple tissues. Our team focused on formulation parameters for FAST agents into lipid nanoparticles (LNP) and lipid coated mesoporous silica nanoparticles (LC-MSN) for enhanced delivery and/or efficacy and in vivo translation. We used lipid formulas that have been shown in literature to facility in vitro and more importantly, in vivo delivery. In our work discussed below, we successfully demonstrate loading and release of FAST agents on silica core and stable LC-MSN in a reasonable size range for in vivo testing.

59 BASIC BIOLOGICAL SCIENCES↗

Status of the IOTA proton injector

The IOTA Proton Injector (IPI), currently under installation at the Fermilab Accelerator Science and Technology facility (FAST), is a machine capable of delivering 20\,mA pulses of protons at 2.5\,MeV to the Integrable Optics Test Accelerator (IOTA) ring. First beam in the IPI beamline is anticipated in the first half of~2024, when it will operate alongside the existing electron injector beamline to facilitate further beam physics research and continued development of novel accelerator technologies at the IOTA ring. This report details the expected operational profile, known challenges, and the current state of installation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the IOTA Proton Injector

The IOTA Proton Injector (IPI), currently under installation at the Fermilab Accelerator Science and Technology facility (FAST), is a machine capable of delivering 20 mA pulses of protons at 2.5 MeV to the Integrable Optics Test Accelerator (IOTA) ring. First beam in the IPI beamline is anticipated in the first half of 2024, when it will operate alongside the existing electron injector beamline to facilitate further beam physics research and continued development of novel accelerator technologies at the IOTA ring. This report details the expected operational profile, known challenges, and the current state of installation.

43 PARTICLE ACCELERATORS↗