Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Tracking Steady Light Sources Amid Luminous Transients

The Transient Event Rejection for Acquisition and Tracking (TERAT) algorithm governs operation of image-data-acquisition and -processing system. TERAT processes digitized image data to acquire (that is, identify) candidate steady source of light, validate candidate source, and track validated source, all in presence of real or apparent luminous transients represented in image data. Source of light tracked could be star or distant luminous beacon. Transients caused by impacts of ionizing radiation on imaging array of photodetectors or by unsteady light sources not meant to be tracked. TERAT functions with limited data-processing resources. TERAT algorithm currently operational on NASA's TOPEX mission.

Kissh, Frank↗

Multi-band automatic sun and sky scanning radiometer system for measurement of aerosols

A weather resistant automatic scanning Sun photometer system is assessed and demonstrated as practical for measurements of aerosol concentrations and properties at remote sites. Interfaced with a transmitter using the Geostationary Data Collection System (GDCS), the data are processed in near real time. The processing allows a time dependence of the aerosols and water vapor and an ongoing assessment of the health and calibration of the instruments. The system's automatic data acquisition, transmission, and processing offer immediate application to atmospheric monitoring and modeling on a regional to global scale and validation of satellite retrievals. It is estimated that under normal circumstances the retrieved aerosol optical thickness has a network wide accuracy of +/- 0.02 from 340 nm to 1020 nm, water vapor +/- 0.2 cm and size distribution from 0.1 to 3 micrometers.

Holben, B. N.↗

Inflight calibration of AVIRIS in 1992 and 1993

In order to pursue the quantitative research objective of AVIRIS, the spectral, radiometric characteristic of the sensor must be known at the time of flight data acquisition. AVIRIS is rigorously calibrated in the laboratory. In addition, three times each year these characteristics of AVIRIS are validated through an inflight calibration experiment. Absolute radiometric calibration and signal-to-noise results are present for the inflight calibration experiment orchestrated in 1992 and 1993.

Green, Robert O.↗

The Novel Nonlinear Adaptive Doppler Shift Estimation Technique and the Coherent Doppler Lidar System Validation Lidar

The signal processing aspect of a 2-m wavelength coherent Doppler lidar system under development at NASA Langley Research Center in Virginia is investigated in this paper. The lidar system is named VALIDAR (validation lidar) and its signal processing program estimates and displays various wind parameters in real-time as data acquisition occurs. The goal is to improve the quality of the current estimates such as power, Doppler shift, wind speed, and wind direction, especially in low signal-to-noise-ratio (SNR) regime. A novel Nonlinear Adaptive Doppler Shift Estimation Technique (NADSET) is developed on such behalf and its performance is analyzed using the wind data acquired over a long period of time by VALIDAR. The quality of Doppler shift and power estimations by conventional Fourier-transform-based spectrum estimation methods deteriorates rapidly as SNR decreases. NADSET compensates such deterioration in the quality of wind parameter estimates by adaptively utilizing the statistics of Doppler shift estimate in a strong SNR range and identifying sporadic range bins where good Doppler shift estimates are found. The authenticity of NADSET is established by comparing the trend of wind parameters with and without NADSET applied to the long-period lidar return data.

Beyon, Jeffrey Y.↗

Inflight Calibration of AVIRIS in 1992 and 1993

In order to pursue the quantitative research objective of AVIRIS, the spectral, radiometric characteristic of the sensor must be known at the time of flight data acquisition. AVIRIS is rigorously calibrated in the laboratory. In addition, three times each year these characteristics of AVIRIS are validated through an inflight calibration experiment. Absolute radiometric calibration and signal-to-noise results are present for the inflight calibration experiment orchestrated in 1992 and 1993.

Chrien, Tom↗

X-ray scatter correction method for dedicated breast computed tomography

Purpose: To improve image quality and accuracy in dedicated breast computed tomography (BCT) by removing the x-ray scatter signal included in the BCT projections. Methods: The previously characterized magnitude and distribution of x-ray scatter in BCT results in both cupping artifacts and reduction of contrast and accuracy in the reconstructions. In this study, an image processing method is proposed that estimates and subtracts the low-frequency x-ray scatter signal included in each BCT projection postacquisition and prereconstruction. The estimation of this signal is performed using simple additional hardware, one additional BCT projection acquisition with negligible radiation dose, and simple image processing software algorithms. The high frequency quantum noise due to the scatter signal is reduced using a noise filter postreconstruction. The dosimetric consequences and validity of the assumptions of this algorithm were determined using Monte Carlo simulations. The feasibility of this method was determined by imaging a breast phantom on a BCT clinical prototype and comparing the corrected reconstructions to the unprocessed reconstructions and to reconstructions obtained from fan-beam acquisitions as a reference standard. One-dimensional profiles of the reconstructions and objective image quality metrics were used to determine the impact of the algorithm. Results: The proposed additional acquisition results in negligible additional radiation dose to the imaged breast ({approx}0.4% of the standard BCT acquisition). The processed phantom reconstruction showed substantially reduced cupping artifacts, increased contrast between adipose and glandular tissue equivalents, higher voxel value accuracy, and no discernible blurring of high frequency features. Conclusions: The proposed scatter correction method for dedicated breast CT is feasible and can result in highly improved image quality. Further optimization and testing, especially with patient images, is necessary to characterize its impact on clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data Acquisition in Wireless Router Link Testbed using GNU Radio Companion

An IEEE 802.11g WLAN wireless-router link test-bed is under development at the Idaho National Laboratory-Wireless Research Center. The project objective is to generate repeatable, high-quality, controlled-noise wireless transmission for software-defined radio (SDR) analysis and research. Signal acquisition for the data link will include both an Ettus X310 (with GNU Radio Companion) in parallel with a Tektronix RSA 306a spectrum analyzer. The integration and validation of the SDR is described. Preliminary results indicate the router test-bed comprised of readily-available WiFi and RF hardware will provide low-noise and repeatable signal captures.

47 OTHER INSTRUMENTATION↗

Full data acquisition in Kelvin Probe Force Microscopy: Mapping dynamic electric phenomena in real space

Kelvin probe force microscopy (KPFM) has provided deep insights into the role local electronic, ionic and electrochemical processes play on the global functionality of materials and devices, even down to the atomic scale. Conventional KPFM utilizes heterodyne detection and bias feedback to measure the contact potential difference (CPD) between tip and sample. This measurement paradigm, however, permits only partial recovery of the information encoded in bias- and time-dependent electrostatic interactions between the tip and sample and effectively down-samples the cantilever response to a single measurement of CPD per pixel. This level of detail is insufficient for electroactive materials, devices, or solid-liquid interfaces, where non-linear dielectrics are present or spurious electrostatic events are possible. Here, we simulate and experimentally validate a novel approach for spatially resolved KPFM capable of a full information transfer of the dynamic electric processes occurring between tip and sample. General acquisition mode, or G-Mode, adopts a big data approach utilising high speed detection, compression, and storage of the raw cantilever deflection signal in its entirety at high sampling rates (> 4 MHz), providing a permanent record of the tip trajectory. We develop a range of methodologies for analysing the resultant large multidimensional datasets involving classical, physics-based and information-based approaches. Physics-based analysis of G-Mode KPFM data recovers the parabolic bias dependence of the electrostatic force for each cycle of the excitation voltage, leading to a multidimensional dataset containing spatial and temporal dependence of the CPD and capacitance channels. We use multivariate statistical methods to reduce data volume and separate the complex multidimensional data sets into statistically significant components that can then be mapped onto separate physical mechanisms. Overall, G-Mode KPFM offers a new paradigm to study dynamic electric phenomena in electroactive interfaces as well as offer a promising approach to extend KPFM to solid-liquid interfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interconnection Standard Grid-Support Function Evaluations Using an Automated Hardware-in-the-Loop Testbed

Grid operators are increasingly turning to advanced grid-support functions in distributed energy resources (DER) to assist with distribution circuit voltage regulation, bulk system frequency control, and power system protection. The U.S. DER certification standard, Underwriters Laboratories (UL) 1741, was revised in September 2016 to add test procedures for multiple grid-support functions. Sandia National Laboratories, SunSpec Alliance, and growing community of collaborators have undertaken a multiyear effort to create an open-source system validation platform (SVP) that automates DER interconnection and interoperability test procedures by communicating with grid simulators, photovoltaic (PV) simulators, data acquisition systems, and interoperable equipment under test. However, the power hardware required for generating the test conditions may be untenable for many organizations. In this paper, we discuss development of the SVP testing capabilities for UL 1741 tests utilizing a controller hardware-in-the-loop testbed that precludes the need for power hardware using a 34.5 kW Austrian Institute of Technology smart grid controller. Finally, analysis of normal ramp rate, soft start ramp rate, specified power factor, volt-VAr, and frequency-watt advanced grid functions, and the effectiveness of the UL 1741 test protocols are included.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-J-23: Characteristics of X-Rays From ExacTrac and Patient Dose From Imaging Procedures

Purpose: The purpose of this investigation is 1) provide the beam characteristics of x-rays produced by a Novalis TX ExacTrac system; 2) present a method to commission such beams, 3) present radiation dose to patients resulting from the imaging procedures. Methods: The Monte Carlo simulations were used to obtain the characteristics of kV beams and validated by measurements. The calculated beam HVLs, profiles and depth-dose curves were benchmarked against measurements. Twelve different image acquisition protocols were studied. The x-ray tube voltage ranges from 70 - 145 kV and milliampere-second (mAs) ranges from 8 - 80 mAs depending on the selection of Cranium, Head & Neck, Thorax or Abdomen imaging protocols. The beam output of each image acquisition protocol was determined by using an ionization chamber. The air kerma calibration factors of the ion chamber were obtained from an Accredited Dosimetry Calibration Laboratory for specified HVLs. Results: The agreements between measured and simulated results were within the uncertainties for HVLs, dose profiles and depth-dose curves. When %dd was normalized at 1 cm depth, its values at depth of 5 cm ranged from 45% to 66% of in water for kV beams range from 70 kVp to 145 kVp respectively. For head images, a typical dose to eye resulting from single projection ranged from 0.008 cGy to 0.025 cGy depending on the cranial image protocols selected. For a single pelvic image the skin dose could reach up to 0.1 cGy from an abdominal protocol. Conclusion: Although multiple pairs of x-ray images are commonly acquired during a daily patient treatment, the imaging doses to patients resulting from the sum of these projected x-rays are generally much less than 0.5 cGy. The knowledge obtained from this investigation can be used to estimate the image dose and optimize the used of the system.

60 APPLIED LIFE SCIENCES↗

Hardware authentication using transmission spectra modified optical fiber.

The ability to authenticate the source and integrity of data is critical to the monitoring and inspection of special nuclear materials, including hardware related to weapons production. Current methods rely on electronic encryption/authentication codes housed in monitoring devices. This always invites the question of implementation and protection of authentication information in an electronic component necessitating EMI shielding, possibly an on board power source to maintain the information in memory. By using atomic layer deposition techniques (ALD) on photonic band gap (PBG) optical fibers we will explore the potential to randomly manipulate the output spectrum and intensity of an input light source. This randomization could produce unique signatures authenticating devices with the potential to authenticate data. An external light source projected through the fiber with a spectrometer at the exit would 'read' the unique signature. No internal power or computational resources would be required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orbit IMU alignment: Error analysis

A comprehensive accuracy analysis of orbit inertial measurement unit (IMU) alignments using the shuttle star trackers was completed and the results are presented. Monte Carlo techniques were used in a computer simulation of the IMU alignment hardware and software systems to: (1) determine the expected Space Transportation System 1 Flight (STS-1) manual mode IMU alignment accuracy; (2) investigate the accuracy of alignments in later shuttle flights when the automatic mode of star acquisition may be used; and (3) verify that an analytical model previously used for estimating the alignment error is a valid model. The analysis results do not differ significantly from expectations. The standard deviation in the IMU alignment error for STS-1 alignments was determined to the 68 arc seconds per axis. This corresponds to a 99.7% probability that the magnitude of the total alignment error is less than 258 arc seconds.

Corson, R. W.↗

Novel Composites for Wing and Fuselage Applications: Novel Wing Design Concepts - Task 1

Design trade studies were conducted to arrive at advanced wing designs that integrated new material forms with innovative structural concepts and cost-effective fabrication methods. A representative spar was selected for design, fabrication, and test to validate the predicted performance. Textile processes, such as knitting, weaving and stitching, were used to produce fiber preforms that were later fabricated into composite span through epoxy Resin Transfer Molding (RTM), Resin Film Infusion (RFI), and consolidation of commingled thermoplastic and graphite tows. The target design ultimate strain level for these innovative structural design concepts was 6000 mu in. per in. The spars were subjected to four-point beam bending to validate their structural performance. The various material form /processing combination Y-spars were rated for their structural efficiency and acquisition cost. The acquisition cost elements were material, tooling, and labor.

Suarez, J. A.↗

Atmospheric Correction Inter-comparison eXercise, ACIX-II Land: An Assessment of Amospheric Correction Processors for Landsat 8 and Sentinel-2 Over Land

The correction of the atmospheric effects on optical satellite images is essential for quantitative and multi-temporal remote sensing applications. In order to study the performance of the state-of-the-art methods in an integrated way, a voluntary and open-access benchmark Atmospheric Correction Inter-comparison eXercise (ACIX) was initiated in 2016 in the frame of Committee on Earth Observation Satellites (CEOS) Working Group on Calibration & Validation (WGCV). The first exercise was extended in a second edition wherein twelve atmospheric correction (AC) processors, a substantially larger testing dataset and additional validation metrics were involved. The sites for the inter-comparison analysis were defined by investigating the full catalogue of the Aerosol Robotic Network (AERONET) sites for coincident measurements with satellites' overpass. Although there were more than one hundred sites for Copernicus Sentinel-2 and Landsat 8 acquisitions, the analysis presented in this paper concerns only the common matchups amongst all processors, reducing the number to 79 and 62 sites respectively. Aerosol Optical Depth (AOD) and Water Vapour (WV) retrievals were consequently validated based on the available AERONET observations. The processors mostly succeeded in retrieving AOD for relatively light to medium aerosol loading (AOD < 0.2) with uncertainties <0.08, while the overall uncertainty values were typically 0.23 ± 0.15. Better performances were observed for WV retrievals with >90% of the results falling within the suggested empirical specifications and with the Root Mean Square Error (RMSE) being mostly <0.25 g/cm2. Regarding Surface Reflectance (SR) validation two main approaches were followed. For the first one, a simulated SR reference dataset was computed over all of the test sites by using the 6SV (Second Simulation of the Satellite Signal in the Solar Spectrum vector code) full radiative transfer modelling (RTM) and AERONET measurements for the required aerosol variables and water vapour content. The performance assessment demonstrated that the retrievals were not biased for most of the bands. The uncertainties ranged from approximately 0.003 to 0.01 (excluding B01) for the best performing processors in both sensors' analyses. For the second one, measurements from the radiometric calibration network RadCalNet over La Crau (France) and Gobabeb (Namibia) were involved in the validation. The performance of the processors was in general consistent across all bands for both sensors and with low standard deviations (<0.04) between on-site and estimated surface reflectance. Overall, our study provides a good insight of AC algorithms' performance to developers and users, pointing out similarities and differences for AOD, WV and SR retrievals. Such validation though still lacks of ground-based measurements of known uncertainty to better assess and characterize the uncertainties in SR retrievals.

Atmospheric correction↗

NASA COAST and OCEANIA Airborne Missions Support Ecosystem and Water Quality Research in the Coastal Zone

NASA has a continuing requirement to collect high-quality in situ data for the vicarious calibration of current and next generation ocean color satellite sensors and to validate the algorithms that use the remotely sensed observations. Recent NASA airborne missions over Monterey Bay, CA, have demonstrated novel above- and in-water measurement capabilities supporting a combined airborne sensor approach (imaging spectrometer, microradiometers, and a sun photometer). The results characterize coastal atmospheric and aquatic properties through an end-to-end assessment of image acquisition, atmospheric correction, algorithm application, plus sea-truth observations from state-of-the-art instrument systems. The primary goal is to demonstrate the following in support of calibration and validation exercises for satellite coastal ocean color products: 1) the utility of a multi-sensor airborne instrument suite to assess the bio-optical properties of coastal California, including water quality; and 2) the importance of contemporaneous atmospheric measurements to improve atmospheric correction in the coastal zone. The imaging spectrometer (Headwall) is optimized in the blue spectral domain to emphasize remote sensing of marine and freshwater ecosystems. The novel airborne instrument, Coastal Airborne In-situ Radiometers (C-AIR) provides measurements of apparent optical properties with high dynamic range and fidelity for deriving exact water leaving radiances at the land-ocean boundary, including radiometrically shallow aquatic ecosystems. Simultaneous measurements supporting empirical atmospheric correction of image data are accomplished using the Ames Airborne Tracking Sunphotometer (AATS-14). Flight operations are presented for the instrument payloads using the Center for Interdisciplinary Remotely-Piloted Aircraft Studies (CIRPAS) Twin Otter flown over Monterey Bay during the seasonal fall algal bloom in 2011 (COAST) and 2013 (OCEANIA) to support bio-optical measurements of phytoplankton for coastal zone research.

Airborne Instruments↗

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Democratizing an electroluminescence imaging apparatus and analytics project for widespread data acquisition in photovoltaic materials

In this work, we present a description of an electroluminescence (EL) apparatus, easily sourced from commercially available components, with a quantitative image processing platform that demonstrates feasibility for the widespread utility of EL imaging as a characterization tool. We validated our system using a Gage R&R analysis to fnd a variance contribution by the measurement system of 80.56%, which is typically unacceptable, but through quantitative image processing and development of correction factors a variance contribution by the measurement system of 2.41% was obtained. We further validated the system by quantifying the signal-to-noise ratio (SNR) and found values consistent with other systems published in the literature, at SNR values of 10-100, albeit at exposure times of greater than 1 s compared to 10 ms for other systems. Finally, this SNR value range is acceptable for image feature recognition, providing the opportunity for widespread data acquisition and large scale data analytics of photovoltaics.

14 SOLAR ENERGY↗

Validation of an image simulation technique for two computed radiography systems: An application to neonatal imaging

Purpose: The purpose of this study is to develop a computer model to simulate the image acquisition for two computed radiography (CR) imaging systems used for neonatal chest imaging: (1) The Agfa ADC Compact, a flying spot reader with powder phosphor image plates (MD 40.0); and (2) the Agfa DX-S, a line-scanning CR reader with needle crystal phosphor image plates (HD 5.0). The model was then applied to compare the image quality of the two CR imaging systems. Methods: Monte Carlo techniques were used to simulate the transport of primary and scattered x rays in digital x-ray systems. The output of the Monte Carlo program was an image representing the energy absorbed in the detector material. This image was then modified using physical characteristics of the CR imaging systems to account for the signal intensity variations due to the heel effect along the anode-cathode axis, the spatial resolution characteristics of the imaging system, and the various sources of image noise. The simulation was performed for typical acquisition parameters of neonatal chest x-ray examinations. To evaluate the computer model, the authors compared the threshold-contrast detectability in simulated and experimentally acquired images of a contrast-detail phantom. Threshold-contrast curves were computed using a commercially available scoring program. Results: The threshold-contrast curves of the simulated and experimentally acquired images show good agreement; for the two CR systems, 93% of the threshold diameters calculated from the simulated images fell within the confidence intervals of the threshold diameter calculated from the experimentally assessed images. Moreover, the superiority of needle based CR plates for neonatal imaging was confirmed. Conclusions: The good agreement between simulated and experimental acquired results indicates that the computer model is accurate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗