Aerodynamic roughness measured in the field and simulated in a wind tunnel

This study evaluates how well values of aerodynamic surface roughness, z sub 0, measured over scale models in wind tunnels correlate with values of z sub 0 measured at full scale in the field. A field experiment was conducted in which values of z sub 0 and u* (wind friction speed) were measured over three arrays of non-erodible roughness elements on a dry lake bed. Wind profiles were measured by ten anemometers on a 15 m mast under thermally neutral atmospheric conditions. Values of z sub 0 increased from .00014 m (dry lake bed only) to .026 m with increasing roughness element density. The three roughness element arrays were simulated at 1/10 and 1/20 scale in an open-circuit atmospheric boundary-layer wind tunnel. Velocities were measured with a boundary-layer pitot-tube rake from the same relative position within the scale model arrays as the anemometers were relative to the field arrays. Each array at each scale was sampled three times at five freestream velocities. Average values of z sub 0 for each model array at each scale were compared with full-scale values of z sub 0 obtained in the field. The field vs. wind tunnel correspondence of z sub 0 is found to be z sub 0 field = 0.2661 x (z sub(0 model) x scale(exp -1))exp .8159.

Sullivan, Robert↗

A new approach to high-speed flow measurements using constant voltage anemometry

The paper addresses the basic features of conventional instrumentation, such as the constant temperature (CTA) and the constant current (CCA) anemometers, their limitations, and describes a totally new approach to high-speed dynamic measurements using a constant voltage anemometer (CVA). The paper describes the design features of a newly developed CVA and compares preliminary results obtained with CVA and conventional anemometry in low- and high-speed flows.

Mangalam, S. M.↗

The Effect of Turbulence on the Drag of Flat Plates

in determining the effect of turbulence on the forces exerted on bodies in the air stream of a wind tunnel, it is commonly assumed that the indications of the standard Pitot-static tube used to determine the air speed are not dependent on the turbulence. To investigate the truth of this assumption, the drag of a normally exposed flat plate, the difference in pressure between the front and rear of a thin circular disk, the rate of rotation of a vane anemometer, and the pressure developed by a standard Pitot-static tube were measured in an air stream for several conditions of turbulence. The results may be interpreted as indicating that there is no appreciable effect of turbulence on the vane anemometer and the standard pitot-static tube, but that there is small effect on the drag of a flat plate and the pressure difference between front and rear of a disk.

Schubauer, G B↗

Comparison between 1-minute and 15-minute averages of turbulence parameters

Sonic anemometers are good instruments for measuring temperature and wind speed and are fast enough to calculate the temperature and wind structure parameters used to calculate the variance in the acoustic index of refraction. However, the turbulence parameters are typically 15-minute averaged point measurements. There are several problems associated with making point measurements and using them to represent a turbulence field. Some of the sonic anemometer data analyzed from the Joint Acoustic Propagation Experiment (JAPE) conducted during July 1991 at DIRT Site located at White Sands Missile Range, New Mexico, are examined.

Noble, John M.↗

Improved Solid-State Microanemometer

Improved solid-state microanemometer suitable for measuring flows in variety of biomedical, industrial, and other applications. Small size, unique design, and one-piece construction provides combination of short response time, structural rigidity, optimal dissipation of heat, and versatility in application. Device includes four integral sensing resistors exposed to flow measured and serves as hot-film anemometer subunits. Sensing resistors connected to external excitation-and-measurement circuits operating in any of standard hot-film-anemometer modes; constant input voltage, constant input current, or constant resistance with feedback.

Henderson, H. Thurman↗

Calculation of tip clearance effects in a transonic compressor rotor

The flow through the tip clearance region of a transonic compressor rotor (NASA rotor 37) was computed and compared to aerodynamic probe and laser anemometer data. Tip clearance effects were modeled both by gridding the clearance gap and by using a simple periodicity model across the ungridded gap. The simple model was run with both the full gap height, and with half the gap height to simulate a vena-contracta effect. Comparisons between computed and measured performance maps and downstream profiles were used to validate the models and to assess the effects of gap height on the simple clearance model. Recommendations were made concerning the use of the simple clearance model. Detailed comparisons were made between the gridded clearance gap solution and the laser anemometer data near the tip at two operating points. The computer results agreed fairly well with the data but overpredicted the extent of the casing separation and underpredicted the wake decay rate. The computations were then used to describe the interaction of the tip vortex, the passage shock, and the casing boundary layer.

Chima, R. V.↗

Study of a Wake Recovery Mechanism in a High-Speed Axial Compressor Stage

This work addresses the significant differences in compressor rotor wake mixing loss which exist in a stage environment relative to a rotor in isolation. The wake decay for a rotor in isolation is due solely to viscous dissipation which is an irreversible process and thus leads to a loss in both total pressure and efficiency. Rotor wake decay in the stage environment is due to both viscous mixing and the inviscid strain imposed on the wake fluid particles by the stator velocity field. This straining process, referred to by Smith (1993) as recovery, is reversible and for a 2D rotor wake leads to an inviscid reduction of the velocity deficit of the wake. A model for the rotor wake decay process is developed and used to quantify the viscous dissipation effects relative to those of inviscid wake stretching. The model is verified using laser anemometer measurements acquired in the wake of a transonic rotor operated in isolation and in a stage configuration at near peak efficiency and near stall operating conditions. Additional insight is provided by a time-accurate 3D Navier-Stokes simulation of the compressor stator flow field at the corresponding stage loading levels. Results from the wake decay model exhibit good agreement with the experimental data. Data from the model, laser anemometer measurements, and numerical simulations indicate that for the rotor/stator spacing used in this work, which is typical of core compressors, rotor wake straining (stretching) is the primary decay process in the stator passage with viscous mixing playing only a minor role. The implications of these results on compressor stage design are discussed.

VanZante, Dale E.↗

Calculation of Tip Clearance Effects in a Transonic Compressor Rotor

The flow through the tip clearance region of a transonic compressor rotor (NASA rotor 37) was computed and compared to aerodynamic probe and laser anemometer data. Tip clearance effects were modeled both by gridding the clearance gap and by using a simple periodicity model across the ungridded gap. The simple model was run with both the full gap height, and with half the gap height to simulate a vena-contracta effect. Comparisons between computed and measured performance maps and downstream profiles were used to validate the models and to assess the effects of gap height on the simple clearance model. Recommendations were made concern- ing the use of the simple clearance model Detailed comparisons were made between the gridded clearance gap solution and the laser anemometer data near the tip at two operating points. The computed results agreed fairly well with the data but overpredicted the extent of the casing separation and underpredicted the wake decay rate. The computations were then used to describe the interaction of the tip vortex, the passage shock, and the casing boundary layer.

Chima, R. V.↗

Investigation of Point Doppler Velocimetry (PDV) for Transition Detection in Boundary Layers

A two-component Point Doppler Velocimeter (PDV) system has been improved through the use of vapor-limited iodine cells that have responses that are insensitive to temperature variations. Two-component PDV velocity measurements have been obtained for a 1 inch diameter uniform circular jet flow at a nominal exit velocity of 60 m/sec, corresponding to a Reynolds number of 100,000. Similar data have also been obtained for an annular jet and a swirling jet, These PDV data runs have been duplicated to judge the repeatability of these measurements, and also have been compared with hot wire anemometer data for the same flow conditions. PDV mean velocity results are repeatable to within approximately 1-2 meters per second; the PDV RMS velocity results are also quite repeatable. Exit profiles of PDV mean axial velocity data generally agree with hot wire anemometer results to within about 2 meters per second as well. However, the PDV RMS velocity results are consistently lower than the hot wire results everywhere but at the exit of the standard jet, where they are too high relative to the hot wire data. This is believed to at least be partially due to the method used to compute the RMS (Root Mean Square).

Kuhlman, John↗

Thin-Film Air-Mass-Flow Sensor of Improved Design Developed

Researchers at the NASA Glenn Research Center have developed a new air-mass-flow sensor to solve the problems of existing mass flow sensor designs. NASA's design consists of thin-film resistors in a Wheatstone bridge arrangement. The resistors are fabricated on a thin, constant-thickness airfoil to minimize disturbance to the airflow being measured. The following photograph shows one of NASA s prototype sensors. In comparison to other air-mass-flow sensor designs, NASA s thin-film sensor is much more robust than hot wires, causes less airflow disturbance than pitot tubes, is more accurate than vane anemometers, and is much simpler to operate than thermocouple rakes. NASA s thin-film air-mass-flow sensor works by converting the temperature difference seen at each leg of the thin-film Wheatstone bridge into a mass-flow rate. The following figure shows a schematic of this sensor with air flowing around it. The sensor operates as follows: current is applied to the bridge, which increases its temperature. If there is no flow, all the arms are heated equally, the bridge remains in balance, and there is no signal. If there is flow, the air passing over the upstream legs of the bridge reduces the temperature of the upstream legs and that leads to reduced electrical resistance for those legs. After the air has picked up heat from the upstream legs, it continues and passes over the downstream legs of the bridge. The heated air raises the temperature of these legs, increasing their electrical resistance. The resistance difference between the upstream and downstream legs unbalances the bridge, causing a voltage difference that can be amplified and calibrated to the airflow rate. Separate sensors mounted on the airfoil measure the temperature of the airflow, which is used to complete the calculation for the mass of air passing by the sensor. A current application for air-mass-flow sensors is as part of the intake system for an internal combustion engine. A mass-flow sensor is used to provide accurate information about the amount of air entering the engine so that the amount of fuel can be adjusted to give the most efficient combustion. The ideal mass-flow sensor would be a rugged design that minimizes the disturbance to the flow stream and provides an accurate reading of both smooth and turbulent flows; NASA's design satisfies these requirements better than any existing design. Most of the mass-flow sensors used today are the hot wire variety. Hot wires can be fragile and cannot accurately measure a turbulent or reversing flow, which is often encountered in an intake manifold. Other types of mass-flow sensors include pitot tubes, vane anemometers, and thermocouple rakes-all of which suffer from some type of performance problem. Because it solves these performance problems while maintaining a simple design that lends itself to low-cost manufacturing techniques, NASA s thin-film resistance temperature detector air-mass-flow sensor should lead to more widespread use of mass-flow sensors.

Fralick, Gustave C.↗

Validation of Multi-Dimensional Stirling Engine Design Codes: Measurements in the 90-Degree Turn Test Section

The work to be presented herein was motivated largely by a desire to improve the understanding of oscillatory fluid mechanics inside a Stirling engine. To this end, a CFD project was undertaken at Cleveland State University with the goal of accurately predicting the fluid dynamics within an engine or engine component. Along with the CFD efforts, a code validation project was undertaken at the University of Minnesota. The material covered herein consists of four main parts. In section 1, an experimental investigation of a small aspect ratio impinging jet is discussed. Included in this discussion is a description of the test facilities and instrumentation. A presentation of the collected data is given and comments are made. Next, in section 2, a parallel experimental investigation is presented in which the same geometry as that of section 1 is used, but the flow conditions are changed from steady unidirectional flow to sinusoidally oscillating flow. In section Two, collected data are presented and comments are made. In section 3, a comparison is made between the results of sections 1 and 2, namely, sinusoidally oscillating flow results are compared to steady, unidirectional flow results from the same geometry. Finally, in section 4, a comparison is made between experimentally collected data (the main subject of this work) and CFD generated results. Furthermore, in appendix A, an introductory description of the primary measurement tool used in the experimental process the hot wire anemometer is given for the unfamiliar. The anemometer calibration procedure is described in appendix B. A portfolio of data reduction and data processing codes is provided in appendix C and lastly, a DVD and a roadmap of its contents is provided in an appendix D. 1.0 Unidirectional Flow Investigations 1.1 Introduction This unidirectional experimental program was undertaken to complement an oscillatory flow investigation conducted at the University of Minnesota. The oscillatory investigation is discussed thoroughly in section 2. We defer the description of the motivation behind these experiments until the introduction of section 2. The work that is discussed in this thesis began (chronologically) with oscillatory flow visualization experiments. It was decided that it would be valuable and important to investigate the flow under unidirectional conditions in the same geometry as that of the oscillatory experiments. The thought was that the unidirectional case would be less complicated to model with a CFD program (a moving boundary would be replaced with a steady state boundary condition). Thus, a series of unidirectional experiments were carried out to capture the important features of the flow within the test section. The purpose of these experiments was to provide a data set for comparison to CFD generated velocity fields. Hot-wire anemometry data were taken and flow visualization was conducted as a standard for code validation. The flow geometry was simple, such that it could be easily gridded in a CFD program. However, the geometry provided separation and transition zones, shear layers and recirculation zones. These characteristics made the flow complex and challenging for CFD computation. We comment that the order of experiments that produced this report is as follows: experimental flow visualization under oscillatory flow conditions was carried out; this was followed by unidirectional flow visualization and hot wire anemometry; finally, oscillatory hot wire anemometry was conducted. We present the results out of chronological order for the following reason: the unidirectional results are easier

Simon, Terrence W.↗

Calibration of Instruments for Measuring Wind Velocity and Direction

Signal Corps wind equipment AN/GMQ-1 consisting of a 3-cup anemometer and wind vane was calibrated for wind velocities from 1 to 200 miles per hour. Cup-shaft failure prevented calibration at higher wind velocities. The action of the wind vane was checked and found to have very poor directional accuracy below a velocity of 8 miles per hour. After shaft failure was reported to the Signal Corps, the cup rotors were redesigned by strengthening the shafts for better operation at high velocities. The anemometer with the redesigned cup rotors was recalibrated, but cup-shaft failure occurred again at a wind velocity of approximately 220 miles per hour. In the course of this calibration two standard generators were checked for signal output variation, and a wind-speed meter was calibrated for use with each of the redesigned cup rotors. The variation of pressure coefficient with air-flow direction at four orifices on a disk-shaped pitot head was obtained for wind velocities of 37.79 53.6, and 98.9 miles per hour. A pitot-static tube mounted in the nose of a vane was calibrated up to a dynamic pressure of 155 pounds per square foot, or approximately 256 miles per hour,

Vogler, Raymond D.↗

Sensors for Using Times of Flight to Measure Flow Velocities

Thin-film sensors for measuring flow velocities in terms of times of flight are undergoing development. These sensors are very small and can be mounted flush with surfaces of airfoils, ducts, and other objects along which one might need to measure flows. Alternatively or in addition, these sensors can be mounted on small struts protruding from such surfaces for acquiring velocity measurements at various distances from the surfaces for the purpose of obtaining boundary-layer flow-velocity profiles. These sensors are related to, but not the same as, hot-wire anemometers. Each sensor includes a thin-film, electrically conductive loop, along which an electric current is made to flow to heat the loop to a temperature above that of the surrounding fluid. Instantaneous voltage fluctuations in segments of the loop are measured by means of electrical taps placed at intervals along the loop. These voltage fluctuations are caused by local fluctuations in electrical resistance that are, in turn, caused by local temperature fluctuations that are, in turn, caused by fluctuations in flow-induced cooling and, hence, in flow velocity. The differential voltage as a function of time, measured at each pair of taps, is subjected to cross-correlation processing with the corresponding quantities measured at other pairs of taps at different locations on the loop. The cross-correlations yield the times taken by elements of fluid to travel between the pairs of taps. Then the component of velocity along the line between any two pairs of taps is calculated simply as the distance between the pairs of taps divided by the travel time. Unlike in the case of hot-wire anemometers, there is no need to obtain calibration data on voltage fluctuations versus velocity fluctuations because, at least in principle, the correlation times are independent of the calibration data.

Fralick, Gutave↗

Atmospheric Turbulence Estimates from a Pulsed Lidar

Estimates of the eddy dissipation rate (EDR) were obtained from measurements made by a coherent pulsed lidar and compared with estimates from mesoscale model simulations and measurements from an in situ sonic anemometer at the Denver International Airport and with EDR estimates from the last observation time of the trailing vortex pair. The estimates of EDR from the lidar were obtained using two different methodologies. The two methodologies show consistent estimates of the vertical profiles. Comparison of EDR derived from the Weather Research and Forecast (WRF) mesoscale model with the in situ lidar estimates show good agreement during the daytime convective boundary layer, but the WRF simulations tend to overestimate EDR during the nighttime. The EDR estimates from a sonic anemometer located at 7.3 meters above ground level are approximately one order of magnitude greater than both the WRF and lidar estimates - which are from greater heights - during the daytime convective boundary layer and substantially greater during the nighttime stable boundary layer. The consistency of the EDR estimates from different methods suggests a reasonable ability to predict the temporal evolution of a spatially averaged vertical profile of EDR in an airport terminal area using a mesoscale model during the daytime convective boundary layer. In the stable nighttime boundary layer, there may be added value to EDR estimates provided by in situ lidar measurements.

Pruis, Matthew J.↗

Hot-Film and Hot-Wire Anemometry for a Boundary Layer Active Flow Control Test

Unsteady active flow control (AFC) has been used experimentally for many years to minimize bluff-body drag. This technology could significantly improve performance of rotorcraft by cleaning up flow separation. It is important, then, that new actuator technologies be studied for application to future vehicles. A boundary layer wind tunnel was constructed with a 1ft-x-3ft test section and unsteady measurement instrumentation to study how AFC manipulates the boundary layer to overcome adverse pressure gradients and flow separation. This unsteady flow control research requires unsteady measurement methods. In order to measure the boundary layer characteristics, both hot-wire and hot-film Constant Temperature Anemometry is used. A hot-wire probe is mounted in the flow to measure velocity while a hot-film array lays on the test surface to measure skin friction. Hot-film sensors are connected to an anemometer, a Wheatstone bridge circuit with an output that corresponds to the dynamic flow response. From this output, the time varying flow field, turbulence, and flow reversal can be characterized. Tuning the anemometers requires a fan test on the hot-film sensors to adjust each output. This is a delicate process as several variables drastically affect the data, including control resistance, signal input, trim, and gain settings.

Control Test↗

Flow Quality Survey of the 8- by 6-Foot Supersonic Wind Tunnel (2015 Test) Prior to the 9- by 15-Foot Acoustic Low-Speed Wind Tunnel Acoustic Improvement Modifications

Prior to the NASA Glenn Research Center 9- by 15-Foot Low-Speed Wind Tunnel (9x15 LSWT) undergoing significant structural and acoustic modifications beginning in 2017, a flow quality survey (FQS) was conducted to characterize the flow quality of the 8- by 6-Foot Supersonic Wind Tunnel (8x6 SWT) test section and facility air dryer. The data from this FQS will be compared to data collected during a FQS following the completion of the 9x15 LSWT Acoustic Improvement Modifications. This document contains only the FQS data collected in November 2015 using the 16-inch-diameter cone cylinder and a set of twenty air dryer bed wind anemometers. The ability to reach the extents of the 8x6 SWT operating envelope with a large blockage model was verified through the 16-inch-diameter cone cylinder tests. The flow uniformity and angularity at the entrance of the facility air dryer was assessed and quantified using the air dryer bed wind anemometers.

Flow Quality Survey↗

Hot-wire Anemometry and Planned Test Entries

- Hot-wire anemometers are sensitive to mass flux and total temperature - Applications for hot-wire anemometry include - Determining the flow quality within a facility - Mapping the flowfield that is influenced by a model - Mean flow distortion - Boundary-layer instabilities & transition - It’s an especially important diagnostic if there is no line of sight - We use a constant temperature anemometer (CTA) at a high overheat & calibrate the wire using a modified King’s Law

Hypersonics↗