Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A generalized a priori dose uncertainty model of IMRT delivery

Multileaf collimator-based intensity modulated radiation therapy (IMRT) is complex because each intensity modulated field consists of hundreds of subfields, each of which is associated with an intricate interplay of uncertainties. In this study, the authors have revised the previously introduced uncertainty model to provide an a priori accurate prediction of dose uncertainty during treatment planning in IMRT. In the previous model, the dose uncertainties were categorized into space-oriented dose uncertainty (SOU) and nonspace-oriented dose uncertainty (NOU). The revised model further divided the uncertainty sources into planning and delivery. SOU and NOU associated with a planning system were defined as inherent dose uncertainty. A convolution method with seven degrees of freedom was also newly applied to generalize the model for practical clinical cases. The model parameters were quantified through a set of measurements, accumulated routine quality assurance (QA) data, and peer-reviewed publications. The predicted uncertainty maps were compared with dose difference distributions between computations and 108 simple open-field measurements using a two-dimensional diode array detector to verify the validity of the model parameters and robustness of the generalized model. To examine the applicability of the model to overall dose uncertainty prediction in IMRT, a retrospective analysis of QA measurements using the diode array detector for 32 clinical IM fields was also performed. A scatter diagram and a correlation coefficient were employed to investigate a correlation of the predicted dose uncertainty distribution with the dose discrepancy distribution between calculation and delivery. In addition, a {gamma} test was performed to correlate failed regions in dose verification with the dose uncertainty map. The quantified model parameters well correlated the predicted dose uncertainty with the probable dose difference between calculations and measurements. It was visually validated with the scatter diagrams. The average correlation coefficient between uncertainty and dose difference of 108 verification measurements was 0.80{+-}0.04, indicating a strong linear correlation. In the clinical IM field studies, the dose uncertainty map mimicked the probable dose difference distribution. The average correlation coefficient between the overall dose uncertainty and the dose difference of 32 QA measurements (total 13 184 comparison points) was 0.75{+-}0.07, which also indicated a strong linear correlation between them. The failed regions of the {gamma} test remarkably corresponded to relatively high dose uncertainty. In conclusion, the dose uncertainty map was able to highlight high dose uncertainty regions, where more care should be taken during the treatment plan. The a priori accurate prediction of dose uncertainty in IMRT will significantly improve the treatment plan evaluation process, thus improving the quality of radiation treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MagMicro with Ultra-High Energy Resolution (FY19 Q3 Progress Report)

The fabrication of the MMC detector arrays involves two photolithographic procedures. The first is to fabricate the Nb magnetization coil and pick-up coils, the SQUID preamplifiers and the associated wiring. This is done on a full 4” Si wafer, which is subsequently diced into ~0.5 cm2 SQUID chips and ~1 cm2 detector chips. The detector chips are then processed separately by depositing and patterning the paramagnetic Ag:Er sensor and support structures and then electroplating the Au absorber. In Q3, we have successfully completed the full wafer processing for the 32-pixel MMC detector arrays, diced the 4” wafer into the smaller chips and tested the individual components. The coils have the required critical current, the heat switches have a critical temperature in the desired range, and the SQUIDs have the required low noise. Unfortunately, the sputter deposition of the paramagnetic Ag:Er sensor failed several times. We spent considerable time to trace the problem to contaminations of the purifier for the Ar sputtering gas that had been exposed to atmosphere for an extended time during an earlier clean room upgrade. We then determined that the purifier is not essential for high-quality Ag:Er sensor films (Fig. 1), and successfully deposited the Ag:Er sensor film on the ~1 cm 2 detector chip.

42 ENGINEERING↗

Preliminary RAM-RODD results for the MUSiC subcritical configurations

The Measurement of Uranium Subcritical and Critical (MUSiC) was performed at the DOE’s National Criticality Experiments Research Center (NCERC) located in the Nevada National Security Site (NNSS). The measurement utilized the Rocky Flats shells to perform benchmark measurements of similar highly enriched uranium (HEU) systems that span a wide range of reactivities. The Rocky Flats (RF) shells are 93.16% U-235 enriched metal hemishells that can be stacked concentrically. Ten configurations were measured with effective multiplication factors spanning between deeply subcritical (~ 0.64) through delayed critical. Details of the measured configurations are listed in Table 1. This unique set of measurements with its large span of reactivies is being used to determine the range over which neutron noise techniques such as Feynman variance-to-mean, Rossi-alpha, and pulsed neutron source techniques can be accurately employed for a bare HEU system. The results of the measurements will be published as a benchmark in The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results will support the growing amount of subcritical benchmark data, such as the SCRaP measurements, that is available to the community. The measurements were performed using several different detector systems for the purposes of cross-validation and obtaining detector independent results. Four detector systems were deployed, three by the NCERC team and one from the University of Michigan. The detector systems included a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (Ø) × 7.59 cm 3 He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), the Rossi Alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAM-RODD), and the Organic Scintillator Array (OSCAR). RAM-RODD is an array of eight 5.08 cm (Ø) × 5.08 cm EJ-309 organic scintillator detectors. OSCAR is a University of Michigan system and is an array of twelve 5.08 cm (Ø) × 5.08 cm stilbene detectors. Details of measurements performed with OSCAR will be discussed in a separate talk. The focus of this work is preliminary results obtained by RAM-RODD for the 8 subcritical configurations. Additional details on the measurements and on the setup and deployment of RAM-RODD will be discussed. Preliminary neutron noise analysis results including Rossi-alpha and Feynman-alpha will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Results from the Majorana Demonstrator

Neutrinoless double-beta decay searches seek to determine the nature of neutrinos, the existence of a lepton violating process, and the eective Majorana neutrino mass. The Majorana Collaboration is assembling an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is composed of 44.8 kg (29.7 kg enriched in 76Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. The initial goals of the Demonstrator are to establish the required background and scalability of a Ge-based, next-generation, tonne-scale experiment. Following a commissioning run that began in 2015, the rst detector module started physics data production in early 2016. We will discuss initial results of the Module 1 commissioning and rst physics run, as well as the status and potential physics reach of the full Majorana Demonstrator experiment. The collaboration plans to complete the assembly of the second detector module by mid-2016 to begin full data production with the entire array.

Majorana Demonstrator↗

Distance-of-Flight Mass Spectrometry: A New Paradigm for Mass Separation and Detection

Distance-of-flight mass spectrometry (DOFMS) offers the advantages of physical separation of ions, array-detection of ions, focusing of initial ion energy, great simplicity, and truly unlimited mass range. DOFMS instrumentation is similar to that of time-of-flight mass spectrometry (TOFMS) and shares its ion source versatility, batch analysis, and rapid spectral generation rate. With constant-momentum ion acceleration and an ion mirror, there is a time at which ions of all m/z values are energy-focused at their particular distance along the flight path. A pulsed field orthogonal to the flight path drives the ions to reach the detector array at this specific time. Results from a 0.31-m proof-of-principle instrument verify the theoretically predicted energy focus and demonstrate how the range of m/z values impinging on the detector array can be readily changed. DOFMS can potentially be combined sequentially with TOFMS to enable simultaneous scanless MS/MS.

dynamic range↗

TH-C-19A-01: Analytic Design Method to Make a 2D Planar, Segmented Ion Chamber Water-Equivalent for Proton Dose Measurements

Purpose: Quality Assurance (QA) measurements of proton therapy fields must accurately measure steep longitudinal dose gradients as well as characterize the dose distribution laterally. Currently, available devices for two-dimensional field measurements perturb the dose distribution such that routine QA measurements performed at multiple depths require multiple field deliveries and are time consuming. Methods: A design procedure for a two-dimensional detector array is introduced whereby the proton energy loss and scatter are adjusted so that the downstream dose distribution is maintained to be equivalent to that which would occur in uniform water. Starting with the design for an existing, functional two-dimensional segmented ion chamber prototype, a compensating material is introduced downstream of the detector to simultaneously equate the energy loss and lateral scatter in the detector assembly to the values in water. An analytic formalism and procedure is demonstrated to calculate the properties of the compensating material in the general case of multiple layers of arbitrary material. The resulting design is validated with Monte Carlo simulations. Results: With respect to the specific prototype design considered, the results indicate that a graphite compensating layer of the proper dimensions can yield proton beam range perturbation less than 0.1mm and beam sigma perturbation less than 2% across the energy range of therapeutic proton beams. Conclusion: We have shown that, for a 2D gas-filled detector array, a graphite-compensating layer can balance the energy loss and multiple Coulomb scattering relative to uniform water. We have demonstrated an analytic formalism and procedure to determine a compensating material in the general case of multiple layers of arbitrary material. This work was supported by the US Army Medical Research and Materiel Command under Contract Agreement No. DAMD17-W81XWH-04-2-0022. Opinions, interpretations, conclusions and recommendations are those of the author and are not necessarily endorsed by the US Army.

07 ISOTOPE AND RADIATION SOURCES↗

The Atacama Cosmology Telescope: The Polarization-Sensitive ACTPol Instrument

The Atacama Cosmology Telescope (ACT) makes high angular resolution measurements of anisotropies in the Cosmic Microwave Background (CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3° field of view, 100 mK cryogenics with continuous cooling, and meta material antireflection coatings. ACTPol comprises three arrays with separate cryogenic optics: two arrays at a central frequency of 148 GHz and one array operating simultaneously at both 97 GHz and 148 GHz. The combined instrument sensitivity, angular resolution, and sky coverage are optimized for measuring angular power spectra, clusters via the thermal Sunyaev–Zel'dovich (SZ) and kinetic SZ signals, and CMB lensing due to large-scale structure. The receiver was commissioned with its first 148 GHz array in 2013, observed with both 148 GHz arrays in 2014, and has recently completed its first full season of operations with the full suite of three arrays. This paper provides an overview of the design and initial performance of the receiver and related systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Megavoltage imaging with a photoconductor based sensor

A photodetector for detecting megavoltage (MV) radiation comprises a semiconductor conversion layer having a first surface and a second surface disposed opposite the first surface, a first electrode coupled to the first surface, a second electrode coupled to the second surface, and a low density substrate including a detector array coupled to the second electrode opposite the semiconductor conversion layer. The photodetector includes a sufficient thickness of a high density material to create a sufficient number of photoelectrons from incident MV radiation, so that the photoelectrons can be received by the conversion layer and converted to a sufficient of recharge carriers for detection by the detector array.

47 OTHER INSTRUMENTATION↗

High-resolution x-ray spectroscopy with the EBIT Calorimeter Spectrometer

The EBIT Calorimeter Spectrometer (ECS) is a production-class 36 pixel x-ray calorimeter spectrometer that has been continuously operating at the Electron Beam Ion Trap (EBIT) facility at Lawrence Livermore National Laboratory for almost 2 years. The ECS was designed to be a long-lifetime, turn-key spectrometer that couples high performance with ease of operation and minimal operator intervention. To this end, a variant of the Suzaku/XRS spaceflight detector system has been coupled to a low-maintenance cryogenic system consisting of a long-lifetime liquid He cryostat, and a closed cycle, {sup 3}He pre-cooled adiabatic demagnetization refrigerator. The ECS operates for almost 3 weeks between cryogenic servicing and the ADR operates at 0.05 K for more than 60 hours between automatic recycles under software control. Half of the ECS semiconductor detector array is populated with mid-band pixels that have a resolution of 4.5 eV FWHM, a bandpass from 0.05-12 keV, and a quantum efficiency of 95% at 6 keV. The other half of the array has thick HgTe absorbers that have a bandpass from 0.3 to over 100 keV, an energy resolution of 33 eV FWHM, and a quantum efficiency of 32% at 60 keV. In addition, the ECS uses a real-time, autonomous, data collection and analysis system developed for the Suzaku/XRS instrument and implemented in off-the-shelf hardware for the ECS. Here we will discuss the performance of the ECS instrument and its implementation as a turnkey cryogenic detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excitation and $\gamma$-decay coincidence measurements at the GRAF beamline for studies of pygmy and giant dipole resonances

Physical studies of electric dipole excitations in atomic nuclei e.g. the structure of pygmy dipole resonances and isovector giant dipole resonances are attracting much attention recently. In this article, we describe a technical development in the coincidence measurement of the excitation processes with the Grand Raiden high-resolution magnetic spectrometer and the γ-decay processes by the CAGRA and SCγ LLA efficient γ-detector arrays at the Research Center for Nuclear Physics at Osaka University. Specifically, we describe how we developed a new beamline (GRAF), for γ detection at the target position by placing the spectrometer at an angle of 4.5-19.0° and by transporting the primary beam to a well-shielded beam dump. Experimental conditions and representative data are shown for each of the two γ-detector arrays.

43 PARTICLE ACCELERATORS↗

239Pu(n, 2n) and 241Pu(n, 2n) surrogate cross section measurements using NeutronSTARS

The goal of this project was to develop a new approach to measuring (n,2n) reactions for isotopes of interest. We set out to measure the 239 Pu(n,2n) and 241 Pu(n,2n) cross sections by directly detecting the 2n neutrons that are emitted. With the goal of improving the 239 Pu(n,2n) cross section and to measure the 241 Pu(n,2n) cross section for the first time. To that end, we have constructed a new neutron-charged-particle detector array called NeutronSTARS. It has been described extensively in Casperson et al. [1] and in Akindele et al. [2]. We have used this new neutron-charged-particle array to measure the 241 Pu and 239 Pu fission neutron multiplicity as a function of equivalent incident-neutron energy from 100 keV to 20 MeV. We have made a preliminary determination of the 239 Pu(n,2n) and 241 Pu(n,2n) cross sections from the surrogate 240 Pu(α,α’2n) and 242 Pu(α,α’2n) reactions respectively. The experimental approach, detector array, data analysis, and results to date are summarized in the following sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of spatially resolved high resolution crystal spectrometry to inertial confinement fusion plasmas

High resolution ({lambda}/{Delta}{lambda}{approx} 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-{mu}m {sup 55}Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10{sup -8}-10{sup -6} times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-81: A Study On Correlation Between Gamma Analysis for Midline and Lateralized Tumors Using VMAT

Purpose: To evaluate the fluence for the midline and lateralized tumors for VMAT technique using 2D seven29 detector array combined with the Octavius phantom. Methods: 60 cases that are already being treated with volumetric modulated arc therapy (VMAT) have selected for this study. This includes tumors situated at the medial and lateral. Medial refers to the tumor situated at the midline of the body and lateral means toward the side or away from the midline of the body. Verification plans were created for each treatment plan in Varian Eclipse treatment planning system (version10, Varian medical systems, Palo Alto,CA) with the 2D Seven29 detector array and the Octavius phantom(PTW, Freiburg, Germany). Measurements were performed on a Varian Clinac 2100 iX, linear accelerator equipped with a millennium 120 leaf collimator. Analysis was done by comparing the fluence measured for the tumors situated on the midline and tumors situated laterally. Results: Fluence measured for all the delivered plans were analyzed using Verisoft software (PTW, Freiburg, Germany). The gamma pass percentage for midline tumors were found to be higher compared with the lateralized ones. The standard deviation between gamma values for midline and lateralized tumors is 2.18 and 3.5 respectively. Also the standard deviation between the point doses for midline and lateralized tumors is 0.38 and 0.29 respectively. The average gamma passing rate for midline tumors is 96.55% and for lateralized tumors are 94.94% for 3%DD and 3mm DTA criteria. From the T test, it was found that there is no significant difference between the gamma pass percentage between midline and lateralized tumors with p value of 0.28. Conclusion: There is no particular correlation found in the gamma pass criteria for midline and lateralized tumors.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-09: Virtual IMRT QA Using Machine Learning: A Multi-Institutional Validation

Purpose: To validate a machine learning approach to Virtual IMRT QA for accurately predicting gamma passing rates using different QA devices at different institutions. Methods: A Virtual IMRT QA was constructed using a machine learning algorithm based on 416 IMRT plans, in which QA measurements were performed using diode-array detectors and a 3%local/3mm with 10% threshold. An independent set of 139 IMRT measurements from a different institution, with QA data based on portal dosimetry using the same gamma index and 10% threshold, was used to further test the algorithm. Plans were characterized by 90 different complexity metrics. A weighted poison regression with Lasso regularization was trained to predict passing rates using the complexity metrics as input. Results: In addition to predicting passing rates with 3% accuracy for all composite plans using diode-array detectors, passing rates for portal dosimetry on per-beam basis were predicted with an error <3.5% for 120 IMRT measurements. The remaining measurements (19) had large areas of low CU, where portal dosimetry has larger disagreement with the calculated dose and, as such, large errors were expected. These beams need to be further modeled to correct the under-response in low dose regions. Important features selected by Lasso to predict gamma passing rates were: complete irradiated area outline (CIAO) area, jaw position, fraction of MLC leafs with gaps smaller than 20 mm or 5mm, fraction of area receiving less than 50% of the total CU, fraction of the area receiving dose from penumbra, weighted Average Irregularity Factor, duty cycle among others. Conclusion: We have demonstrated that the Virtual IMRT QA can predict passing rates using different QA devices and across multiple institutions. Prediction of QA passing rates could have profound implications on the current IMRT process.

60 APPLIED LIFE SCIENCES↗

SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry

Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.

60 APPLIED LIFE SCIENCES↗

SU-F-T-173: One-Scan Protocol: Verifying the Delivery of Spot-Scanning Proton Beam

Purpose: Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread use. Moreover, since there may be an energy dependence, which manifests as a depth dependence, this may require additional measurements for each patient. We present a one-scan protocol to simplify the procedure. Methods: We performed the calibration using an EBT3 film at depths of 18, 20, 24cm of Plastic Water exposed by a 6-level step-wedge plan on a Proteus Plus proton system (IBA, Belgium). The calibration doses ranged 65–250 cGy(RBE) for proton energies of 170–200MeV. A clinical prostate+nodes plan was used for validation. The planar doses at selected depths were measured with EBT3 films and analyzed using one-scan protocol (one-scan digitization of QA film and at least one film exposed to known dose). The Gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film, IBA MatriXX PT, versus TPS calculations were analyzed and compared. Results: The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate of ∼95% for 2%/2mm and slightly lower passing rates were obtained from an ion chamber array detector. We were able to demonstrate that the use of a proton step-wedge provided clinically acceptable results and minimized variations between film-scanner orientation, inter-scan, and scanning conditions. Furthermore, it could be derived from no more than two films exposed to known doses (one could be zero) for rescaling the master calibration curve at each depth. Conclusion: The use of a proton step-wedge for calibration of EBT3 film increases efficiency. The sensitivity of the calibration to depth variations has been explored. One-scan protocol results appear to be comparable to that of the ion chamber array detector. One author has a research grant from Ashland Inc., the manufacturer of the GafChromic film.

60 APPLIED LIFE SCIENCES↗

Status of the Majorana Demonstrator

The Majorana Collaboration is constructing the Majorana Demonstrator, an ultra-low background, 40-kg modular high purity Ge detector array to search for neutrinoless double-beta decay in 76 Ge. In view of the next generation of tonne-scale Ge-based neutrinoless double-beta decay searches that will probe the neutrino mass scale in the inverted-hierarchy region, a major goal of the Demonstrator is to demonstrate a path forward to achieving a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value at 2039 keV. Lastly, the current status of the Demonstrator is discussed, as are plans for its completion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the Versatile Array of Neutron Detectors at Low Energy (VANDLE)

The Versatile Array of Neutron Detectors at Low Energy (VANDLE) is a new, highly efficient plastic-scintillator array constructed for decay and transfer reaction experimental setups that require neutron detection. The versatile and modular design allows for customizable experimental setups including beta-delayed neutron spectroscopy and (d,n) transfer reactions in normal and inverse kinematics. The neutron energy and prompt-photon discrimination is determined through the time of flight technique. Fully digital data acquisition electronics and integrated triggering logic enables some VANDLE modules to achieve an intrinsic efficiency over 70% for 300-keV neutrons, measured through two different methods. A custom Geant4 simulation models aspects of the detector array and the experimental setups to determine efficiency and detector response. Lastly, a low detection threshold, due to the trigger logic and digitizing data acquisition, allowed us to measure the light-yield response curve from elastically scattered carbon nuclei inside the scintillating plastic from incident neutrons with kinetic energies below 2 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗