Search NASA⌕ Search

SEARCH · Search NASA

Results for “distribution system operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

An Operational Resilience Metric for Modern Power Distribution Systems

The electrical power system is the backbone of our nations critical infrastructure. It has been designed to withstand single component failures based on a set of reliability metrics which have proven acceptable during normal operating conditions. However, in recent years there has been an increasing frequency of extreme weather events. Many have resulted in widespread long-term power outages, proving reliability metrics alone do not provide adequate energy security. As a result, researchers have focused their efforts on a new set of metrics based on the concept of resilience to ensure efficient operation of power systems during extreme events. A resilient system has the ability to resist, adapt, and recover from disruptions. Therefore, resilience has demonstrated itself as a promising concept for currently faced challenges in power distribution systems. In this work, we propose a real-time resilience metric for modern power distribution systems. The metric is an aggregation of the controllable assets adaptive capacity, or their temporal flexibility in real and reactive power. This metric gives information to the magnitude and duration of a disturbance which the system can respond to without having to drop loads or have stability issues in voltage or frequency. We demonstrate the impact to resilience in a case study under normal operation and during a power contingency on a microgrid. In the future, this information can be used by operators to make more informed decisions based on system resilience in an effort to prevent power outages.

42 ENGINEERING↗

Launch Processing System operations with a future look to Operations Analyst (OPERA)

The Launch Processing System architecture and the ground support operations required to provide Shuttle System engineers with the capability to safely process and launch an Orbiter are described. The described ground operations are the culmination of eleven years of experience and redesign. Some of the 'lessons learned' are examined, and problem areas which ground support operations have identified over the years as the Shuttle and Launch Processing Systems continue to grow in complexity are discussed. The Operational Analyst for Distributed Systems (OPERA), a proposed set of expert systems for the Launch Processing System Operational assistance, is discussed along with its extensions to prospective future configurations and components for the Launch Processing System.

Heard, Astrid E.↗

A Hierarchical Control Architecture: Utilization of Behind-the-Meter Appliances with Increased Visibility and Controllability

Optimal operations of distribution systems to enhance reliability and resiliency can be achieved if information with higher fidelity can be accessed from grid premise devices. This paper discusses a hierarchical control architecture that can introduce higher visibility and controllability by utilizing the estimated injection and absorption of different behind-the-meter controllable loads, and DERs, including EVs, within a premise. The acquired information is used to make control decisions for scheduling the premise appliances to reduce energy consumptions. The premise controller can also optimize the consumptions on a day-to-day basis in addition to taking input signals from the utility operators to support grid-service events (e.g., peak shaving). The entire control architecture is designed in a modular and scalable fashion that provides benefits to the utility from the reuse of existing infrastructure while creating opportunities for various grid services to be enabled by the operation of premise controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Lake Elsinore, California

This report presents the long-term evaluation results from a hot-dry climate project that examines the room-to-room temperature conditions that exist in a high performance envelope, the performance of a simplified air distribution system, and a comparison of modeled energy performance with measured energy use. The project, a prototype house built by K. Hovnanian Homes’ Ontario Group, is located in Lake Elsinore, Riverside County, California, and achieves a 50% level of whole house source energy savings with respect to the Building America (BA) Benchmark Definition 2009 (Hendron and Engebrecht 2010). Temperature measurements in three rooms indicate that the temperature difference between the measured locations and the thermostat were within recommendations 90.3% of the time in heating mode and 99.3% of the time in cooling mode. The air distribution system is operating efficiently with average delivered temperatures adequate to facilitate proper heating and cooling and only minor average temperature differences observed between the system’s plenum and farthest register. Monitored energy use results for the house indicate that it is using less energy than predicted from modeling. A breakdown of energy use according to end use determined little agreement between comparable values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Lake Elsinore, Californi

This report presents the long-term evaluation results from a hot-dry climate project that examines the room-to-room temperature conditions that exist in a high performance envelope, the performance of a simplified air distribution system, and a comparison of modeled energy performance with measured energy use. The project, a prototype house built by K. Hovnanian Homes’ Ontario Group, is located in Lake Elsinore, Riverside County, California, and achieves a 50% level of whole house source energy savings with respect to the Building America (BA) Benchmark Definition 2009 (Hendron and Engebrecht 2010). Temperature measurements in three rooms indicate that the temperature difference between the measured locations and the thermostat were within recommendations 90.3% of the time in heating mode and 99.3% of the time in cooling mode. The air distribution system is operating efficiently with average delivered temperatures adequate to facilitate proper heating and cooling and only minor average temperature differences observed between the system’s plenum and farthest register. Monitored energy use results for the house indicate that it is using less energy than predicted from modeling. A breakdown of energy use according to end use determined little agreement between comparable values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Results from Evaluation of Advanced New Construction Packages in Test Homes: Lake Elsinore, California

This report presents the long-term evaluation results from a hot-dry climate project that examines the room-to-room temperature conditions that exist in a high performance envelope, the performance of a simplified air distribution system, and a comparison of modeled energy performance with measured energy use. The project, a prototype house built by K. Hovnanian Homes' Ontario Group, is located in Lake Elsinore, Riverside County, California, and achieves a 50% level of whole house source energy savings with respect to the Building America (BA) Benchmark Definition 2009 (Hendron and Engebrecht 2010). Temperature measurements in three rooms indicate that the temperature difference between the measured locations and the thermostat were within recommendations 90.3% of the time in heating mode and 99.3% of the time in cooling mode. The air distribution system is operating efficiently with average delivered temperatures adequate to facilitate proper heating and cooling and only minor average temperature differences observed between the system's plenum and farthest register. Monitored energy use results for the house indicate that it is using less energy than predicted from modeling. A breakdown of energy use according to end use determined little agreement between comparable values.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Impact of Distributed Energy Resources on the Bulk Electric System: Combined Modeling of Transmission and Distribution Systems and Benchmark Case Studies

The high penetration of distributed energy resources (DERs) on modern distribution systems introduces intermittent power generation, stochastic system operating conditions, and bi-directional power flows that impact the system responses to various types of disturbances and may pose challenges to the operations and reliability of the Bulk Electric System (BES). In order to understand the impact of DERs on the planning and operation of the BES, the distribution system can no longer be represented as a single load at a node on the transmission system. At the same time, advanced control capabilities of DERs offer potential opportunities for improving BES reliability by transforming DERs from a passive “do no harm” resource to an active “support reliability” resource when applied in a planned and well-thought-out manner. This concept is often described as DER “flexibility.” With the persistent trend towards a high- penetration of DERs in distribution systems, regulators such as the North American Electric Reliability Corporation (NERC), planning coordinators and grid operators are in serious need of understanding the full-spectrum impact of DERs on the BES to ensure secure and reliable grid planning and operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Piecewise Linear Optimization for Public EV Charging Depots in Different Utility Environments

With the proliferation of electric vehicles (EVs), EV supply equipment technology is being pushed to increasingly higher power levels, such as extreme fast charging (XFC) at 300kW or more. As more public XFC depots are connected to electric distribution systems, utility operators will mitigate their impact with pricing schemes and programs such as demand response, demand charges, and time-varying prices. In this paper we describe an XFC management system that combines an on-site battery energy storage system and an optimization application that minimizes the cost to operate the depot in light of the utility pricing programs. We have designed the optimizer specially to use fast and simple linear programming so that it can be deployed to low-cost computing platforms. We also describe how several utility pricing schemes are integrated into a single piecewise model, reducing the engineering effort to implement the optimizer in different utility environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Convolutional Neural Network-Based Protection-Zone Classification of Faults in Distribution Feeders with Photovoltaics.

Fault detection and isolation is critical for reliable operation of distribution systems. The ride-through requirements for the distributed energy resources (DER), mandated by the IEEE 1547-2018 standard, makes it challenging to use undervoltage (UV) conditions for fault detection. In addition, with low fault current contribution from these inverter-based DERs, the time-overcurrent relays are also less effective. Thus motivated, this paper presents a learning-based approach for fault detection and localization. A convolutional neural network (CNN)-based model is proposed which uses local voltage and current waveforms from DER locations and feeder substations, for training a zonal classifier. The classifier can be adopted into any relay-like device for discriminating between faults originating from different protection zones. The performance of the proposed approach was tested on publicly available test feeders with distributed photovoltaics (PVs).

Fault localization, convolutional neural networks,↗

Simplified Transactive Distribution Grids for Bulk Power System Mechanism Development

As distributed energy resources and smart devices become omnipresent in the electrical power grid, transactive energy control mechanisms are evolving. From real-time to day-ahead markets, these transactive energy algorithms involve more and more agents, whose behavior is going to affect the transmission and generation network. In order to study the interaction between the wholesale and retail energy markets, extensive co-simulations are performed. To be able to redesign, evaluate, and verify new control algorithms, the simulations need to provide results in a fast and reliable manner. This work has built and tested a transactive distribution grid model, the DSO-Stub, meant to offer a configurable distribution retail market while ensuring the computational burden is not significantly increased.

Transactive Energy, , Distribution System Operator↗

Leveraging AMI data for distribution system model calibration and situational awareness

The many new distributed energy resources being installed at the distribution system level require increased visibility into system operations that will be enabled by distribution system state estimation (DSSE) and situational awareness applications. Reliable and accurate DSSE requires both robust methods for managing the big data provided by smart meters and quality distribution system models. This paper presents intelligent methods for detecting and dealing with missing or inaccurate smart meter data, as well as the ways to process the data for different applications. It also presents an efficient and flexible parameter estimation method based on the voltage drop equation and regression analysis to enhance distribution system model accuracy. Finally, it presents a 3-D graphical user interface for advanced visualization of the system state and events. Moreover, we demonstrate this paper for a university distribution network with the state-of-the-art real-time and historical smart meter data infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Interoperable SCADA Communications for PV Inverters through Embedded Controllers

The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.

14 SOLAR ENERGY↗

High performance architecture for robot control

Practical aspects of the design and implementation of a modular, high performance, parallel computer control system for telerobots are discussed. Topics of consideration include system architecture, operator interface, and control execution. In a laboratory environment, a telerobotics test control configuration is used to obtain measurements on communications and control loop timing for use in an effective full scale operational system design. The feasibility of the selected architectural approach has been successfully demonstrated. The modularity of the software and hardware enables ease of transport for use in the operational system. The distributed partioning of the control algorithms and the performance measurements acquired during control system implementation are discussed.

Byler, E.↗

Using Transparent Informed Prefetching (TIP) to reduce file read latency

As processor performance gains continue to outstrip Input/Output gains, I/O performance is becoming critical to overall system performance. File read latency is the most significant bottleneck for high performance I/O. Other aspects of I/O performance benefit from recent advances in disk bandwidth and throughput resulting from disk arrays, and in write performance derived from buffered write behind and the Log-structured File System. The access gap problem limiting improvements in read latency is exacerbated by distributed file systems operating over networks with diverse bandwidth. Focus is on extending the power of caching and prefetching to reduce file read latencies by exploiting hints from high-levels of a system. Such Transparent Informed Prefetching, TIP, and its benefits are described. It is argued that hints that disclose high level knowledge are a means for transferring optimization information across, without violating, module boundaries. How TIP can be used to convert the high throughput of new technologies such as disk arrays and log-structured file systems into low latency for applications is discussed. Our preliminary experiments show reductions in wall - clock execution time of 13 percent and 20 percent for a multiple module compilation tool (make) accessing data on a local disk and remote Coda file server, respectively, and a reduction of 30 percent for a text search (grep) remotely accessing many small files.

Patterson, R. H.↗

Batching System for Superior Service

Veridian's Portable Batch System (PBS) was the recipient of the 1997 NASA Space Act Award for outstanding software. A batch system is a set of processes for managing queues and jobs. Without a batch system, it is difficult to manage the workload of a computer system. By bundling the enterprise's computing resources, the PBS technology offers users a single coherent interface, resulting in efficient management of the batch services. Users choose which information to package into "containers" for system-wide use. PBS also provides detailed system usage data, a procedure not easily executed without this software. PBS operates on networked, multi-platform UNIX environments. Veridian's new version, PBS Pro,TM has additional features and enhancements, including support for additional operating systems. Veridian distributes the original version of PBS as Open Source software via the PBS website. Customers can register and download the software at no cost. PBS Pro is also available via the web and offers additional features such as increased stability, reliability, and fault tolerance.A company using PBS can expect a significant increase in the effective management of its computing resources. Tangible benefits include increased utilization of costly resources and enhanced understanding of computational requirements and user needs.

Source record↗

A New Definition for Ground Control

LandForm(R) VisualFlight(R) blends the power of a geographic information system with the speed of a flight simulator to transform a user's desktop computer into a "virtual cockpit." The software product, which is fully compatible with all Microsoft(R) Windows(R) operating systems, provides distributed, real-time three-dimensional flight visualization over a host of networks. From a desktop, a user can immediately obtain a cockpit view, a chase-plane view, or an airborne tracker view. A customizable display also allows the user to overlay various flight parameters, including latitude, longitude, altitude, pitch, roll, and heading information. Rapid Imaging Software sought assistance from NASA, and the VisualFlight technology came to fruition under a Phase II SBIR contract with Johnson Space Center in 1998. Three years later, on December 13, 2001, Ken Ham successfully flew NASA's X-38 spacecraft from a remote, ground-based cockpit using LandForm VisualFlight as part of his primary situation awareness display in a flight test at Edwards Air Force Base, California.

Source record↗

Aspect-Oriented Programming

Computer science has experienced an evolution in programming languages and systems from the crude assembly and machine codes of the earliest computers through concepts such as formula translation, procedural programming, structured programming, functional programming, logic programming, and programming with abstract data types. Each of these steps in programming technology has advanced our ability to achieve clear separation of concerns at the source code level. Currently, the dominant programming paradigm is object-oriented programming - the idea that one builds a software system by decomposing a problem into objects and then writing the code of those objects. Such objects abstract together behavior and data into a single conceptual and physical entity. Object-orientation is reflected in the entire spectrum of current software development methodologies and tools - we have OO methodologies, analysis and design tools, and OO programming languages. Writing complex applications such as graphical user interfaces, operating systems, and distributed applications while maintaining comprehensible source code has been made possible with OOP. Success at developing simpler systems leads to aspirations for greater complexity. Object orientation is a clever idea, but has certain limitations. We are now seeing that many requirements do not decompose neatly into behavior centered on a single locus. Object technology has difficulty localizing concerns invoking global constraints and pandemic behaviors, appropriately segregating concerns, and applying domain-specific knowledge. Post-object programming (POP) mechanisms that look to increase the expressiveness of the OO paradigm are a fertile arena for current research. Examples of POP technologies include domain-specific languages, generative programming, generic programming, constraint languages, reflection and metaprogramming, feature-oriented development, views/viewpoints, and asynchronous message brokering. (Czarneclu and Eisenecker s book includes a good survey of many of these technologies).

Elrad, Tzilla↗