Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Neutron detector simultaneously measures fluence and dose equivalent

Neutron detector acts as both an area monitoring instrument and a criticality dosimeter by simultaneously measuring dose equivalent and fluence. The fluence is determined by activation of six foils one inch below the surface of the moderator. Dose equivalent is determined from activation of three interlocked foils at the center of the moderator.

Dvorak, R. F.↗

Integral dose during constant velocity motion near a space power reactor

The dose rate in a rotationally-symmetric radiation field near a space power reactor is assumed to be inversely proportional to separation distance squared and directly proportional either to a constant or a constant times the sine-cubed of a polar angle. Constant velocity motion is examined in both cases in both two and three dimensional geometries. The two dimensional geometry occurs when the line of motion and the field axis of symmetry are co-planar. The dose integral in the sine-cubed region may be integrated directly, but a more useful form is obtained after a change of variable. A coordinate system rotation greatly simplifies the results. The three dimensional problem is integrated after a change of variable. Finally, tables of normalized functions are presented and discussed.

Manning, H. S.↗

On the use of quality factors and fluence to dose rate conversion in human radiation exposures

It is shown that various combinations of numbers and factors arrive at estimates of dose and dose effectiveness from values of fluence; but as yet it has not been possible to use biological data with the same degree of precision to estimate the physical data. It would seem that the most reasonable way to use the human data that exist is to apply them as far as possible to the human animal as a whole.

Sondhaus, C. A.↗

Hardening electronic devices against very high total dose radiation environments

The possibilities and limitations of hardening silicon semiconductor devices to the high neutron and gamma radiation levels and greater than 10 to the eighth power rads required for the NERVA nuclear engine development are discussed. A comparison is made of the high dose neutron and gamma hardening potential of bipolar, metal insulator semiconductors and junction field effect transistors. Experimental data is presented on device degradation for the high neutron and gamma doses. Previous data and comparisons indicate that the JFET is much more immune to the combined neutron displacement and gamma ionizing effects than other transistor types. Experimental evidence is also presented which indicates that p channel MOS devices may be able to meet the requirements.

Buchanan, B.↗

Response of mouse epidermal cells to single doses of heavy-particles

The survival of mouse epidermal cells to heavy-particles has been studied In Vivo by the Withers clone technique. Experiments with accelerated helium, lithium and carbon ions were performed. The survival curve for the helium ion irradiations used a modified Bragg curve method with a maximum tissue penetration of 465 microns, and indicated that the dose needed to reduce the original cell number to 1 surviving cell/square centimeters was 1525 rads with a D sub o of 95 rads. The LET at the basal cell layer was 28.6 keV per micron. Preliminary experiments with lithium and carbon used treatment doses of 1250 rads with LET's at the surface of the skin of 56 and 193 keV per micron respectively. Penetration depths in skin were 350 and 530 microns for the carbon and lithium ions whose Bragg curves were unmodified. Results indicate a maximum RBE for skin of about 2 using the skin cloning technique. An attempt has been made to relate the epidermal cell survival curve to mortality of the whole animal for helium ions.

Leith, J. T.↗

Proton dose approximation in arbitrary convex geometry

An expansion is derived for the solution to the transport equation in two dimensions subject to boundary conditions given for an arbitrary convex region. Questions of high-energy transport are considered along with the properties of the dose response function. The expansion of the solution of the transport equation is presented in terms of a parameter which measures the lateral dispersion of an unidirectional beam. This parameter is usually small and the expansion is expected to converge rapidly. The dominant term in the expansion is related to fluence-to-dose conversion factors in a semiinfinite slab for normal incidence. A convenient parameterization of the conversion factors is provided along with numerical examples.

Wilson, J. W.↗

Justification of permissible doses of radiation during prolonged space flights

Maximum permissible radiation doses for astronauts are reported based on chronic radiation experiments with dogs and actual measurements during space flights. Observed were clinical conditions, peripheral blood and marrow, the state of the cardiovascular system, higher nervous activity, the state of the vestibular analyzer, the organ of vision, spermatogenic function and the ability to reproduce, the state of immunity and a number of biological indices in blood and tissues. The following maximum permissible doses are determined as preliminary values: 1 year of flight - 200 rem; 2 years of flight - 250 rem; 3 years of flight - 275 rem.

Grigoryev, Y. G.↗

Lymphoid cell kinetics under continuous low dose-rate gamma irradiation: A comparison study

A comparison study was conducted of the effects of continuous low dose-rate gamma irradiation on cell population kinetics of lymphoid tissue (white pulp) of the mouse spleen with findings as they relate to the mouse thymus. Experimental techniques employed included autoradiography and specific labeling with tritiated thymidine (TdR-(h-3)). The problem studied involved the mechanism of cell proliferation of lymphoid tissue of the mouse spleen and thymus under the stress of continuous irradiation at a dose rate of 10 roentgens (R) per day for 105 days (15 weeks). The aim was to determine whether or not a steady state or near-steady state of cell population could be established for this period of time, and what compensatory mechanisms of cell population were involved.

Foster, B. R.↗

Proton-tissue dose buildup factors

When an object is exposed to external radiation, the dose field within the object is a complicated function of the character of the external radiation, the shape of the object (including orientation), and the object's material composition. In this note, the dose conversion factors for protons in tissue are represented using buildup factors. A parametric form for the buildup factors is obtained. The values of the parameters are derived from Monte Carlo calculations of various authors. All the necessary information to estimate nuclear reaction effects in proton irration of convex objects of arbitrary shape is included.

Wilson, J. W.↗

Depth-dose relations for heavy ion beams

Radiation transport of heavy ions in matter is of interest to radiological protection in space and high-altitude aircraft. In addition, heavy ion beams are expected to be of advantage in radiotherapy since their characteristic Bragg curve allows a relative reduction of the dose in reaching a tumor site and the near elimination of exposure beyond the tumor region as the beam exits the body. Furthermore, the radioresistance of tumorous cells due to their hypoxic state may be reduced or eliminated by the high specific ionization of heavy ion beams. The depth-dose distribution of heavy ion beams consists of energy deposited by the attenuated primary beam with its characteristic Bragg curve and a relatively unstructured background due to secondary radiations produced in nuclear reactions. As the ion mass increases, the secondary contribution becomes more structured and may add significantly to the Bragg peak of the primary ions. The result for heavy ions (z greater than 20) is a greatly broadened Bragg peak region, especially in comparison to straggling effects, which may prove to be of importance in radiotherapy and biomedical research.

Wilson, J. W.↗

Total-dose radiation effects data for semiconductor devices, volume 2

Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

Price, W. E.↗

Total dose effects in the 54HC family of microcircuits

Motorola and National Semiconductor 54HC00 and 54HC74 microcircuits were evaluated using CO-60 to determine their total dose radiation hardness. The devices were found to be radiation soft failing parametrically between 5 and 10 K rads and functionally between 20 and 40 K rads. The failures were bias dependent, relatively insensitive to dose rate, and only annealed moderately when left unbiased at room temperature.

Ropiak, S.↗

Total-dose radiation effects data for semiconductor devices. 1985 supplement. Volume 2, part A

Steady-state, total-dose radiation test data, are provided in graphic format for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. This volume provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done using the JPL or Boeing electron accelerator (Dynamitron) which provides a steady-state 2.5 MeV electron beam. However, some radiation exposures were made with a Cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose.

Martin, K. E.↗

Total-dose radiation effects data for semiconductor devices. 1985 Supplement. Volume 2, part B

Steady-state, total-dose radiation test data are provided in graphic format, for use by electronic designers and other personnel using semiconductor devices in a radiation environment. The data were generated by JPL for various NASA space programs. The document is in two volumes: Volume 1 provides data on diodes, bipolar transistors, field effect transistors, and miscellaneous semiconductor types, and Volume 2 (Parts A and B) provides data on integrated circuits. The data are presented in graphic, tabular, and/or narrative format, depending on the complexity of the integrated circuit. Most tests were done steady-state 2.5-MeV electron beam. However, some radiation exposures were made with a Cobalt-60 gamma ray source, the results of which should be regarded as only an approximate measure of the radiation damage that would be incurred by an equivalent electron dose. All data were generated in support of NASA space programs by the JPL Radiation Effects and Testing Group (514).

Martin, K. E.↗

Radiation dose prediction for Space Station

A detailed examination is conducted of the basis for the significant differences in Space Station radiation dose predictions that result from magnetic field model extrapolations into the future, with attention to the radiation attenuation effects of the residual atmospheric layer at altitudes of less than 1000 km. A model adjustment is proposed to supplant the arbitrary procedure of magnetic field extrapolation into the future. At altitudes below 500 km and low inclination, and with nominal module wall thicknesses, the new predictions for a 90-day Space Station tour are found to be well within current radiation dose limit guidelines.

Mccormack, Percival D.↗

Low altitude flux and dose measurements during two solar flare events

The dosimeter on board the low altitude polar orbiting DMSP/F7 satellite makes dose and flux measurements for electrons with energies greater than 1.0, 2.5, 5.0 and 10.0 MeV; and for protons with energies greater than 20, 35, 51, and 75 MeV. The characteristics and performance of the dosimeter are illustrated by presenting dose and flux data taken during the solar flare proton events of February 16 and April 26, 1984.

Brautigam, D. H.↗

Effects Of Dose Rates On Radiation Damage In CMOS Parts

Report describes measurements of effects of ionizing-radiation dose rate on consequent damage to complementary metal oxide/semiconductor (CMOS) electronic devices. Depending on irradiation time and degree of annealing, survivability of devices in outer space, or after explosion of nuclear weapons, enhanced. Annealing involving recovery beyond pre-irradiation conditions (rebound) detrimental. Damage more severe at lower dose rates.

Goben, Charles A.↗