Lessons Learned for Responsible Use of Cloud in the Cirrus Project, Following the CrowdStrike Outage Event

A disruption in CrowdStrike’s Falcon cybersecurity platform on July 19th, 2024, caused worldwide chaos. This event highlights the imperative need for cloud security measures for networks that are critically reliant on cloud technology. This incident negatively impacted air travel, government networks, and critical infrastructure sectors such as hospitals and financial institutions. While no electric utilities had a physical impact, and few had an IT impact, there were issues created by loss of cloud services, and other interrelated industries. For utilities and energy distribution organizations, understanding and mitigating these risks is essential. The Cirrus tool offers a strategic solution engineered to weave cloud integration seamlessly into the fabric of operational management, thereby enhancing resilience and streamlining efficiency in the face of digital challenges.

25 ENERGY STORAGE↗

Topological Machine Learning Methods for Power System Responses to Contingencies

While deep learning tools, coupled with the emerging machinery of topological data analysis, are proven to deliver various performance gains in a broad range of applications, from image classification to biosurveillance to blockchain fraud detection, their utility in areas of high societal importance such as power system modeling and, particularly, resilience quantification in the energy sector yet remains untapped. To provide fast acting synthetic regulation and contingency reserve services to the grid while having minimal disruptions on customer quality of service, we propose a new topology-based system that depends on a neural network architecture for impact metric classification and prediction in power systems. This novel topology-based system allows one to evaluate the impact of three power system contingency types, in conjunction with transmission lines, transformers, and transmission lines combined with transformers. We show that the proposed new neural network architecture equipped with local topological measures facilitates more accurate classification of unserved load as well as the amount of unserved load. In addition, we are able to learn more about the complex relationships between electrical properties and local topological measurements on their simulated response to contingencies for the NREL-SIIP power system.

contingency analysis↗

Oak Ridge National Laboratory Pilot Demonstration of an Attestation and Anomaly Detection Framework using Distributed Ledger Technology for Power Grid Infrastructure

This report summarizes the design and pilot demonstration of a framework called Grid Guard that was created to provide increased data and device trustworthiness to electric grid devices by leveraging distributed ledger technology (DLT), specifically blockchain. Grid Guard contains a combination of core cryptographic methods such as the secure hash algorithm (SHA), and asymmetric cryptography, private permissioned blockchain, baselining configuration data, consensus algorithm (Raft) and the Hyperledger Fabric (HLF) framework. The system implements a low energy, fast, and robust enhancement to system trustworthiness within and across electric grid systems such as substations, control centers and metering infrastructures. Blockchain is a distributed database structured that provides a practically unalterable (immutable) timeline of stored transactions. By relying on hashing and the Raft consensus algorithm, if an entity tries to illegitimately alter a record at one instance of the database the other ledger nodes are not altered. They work to cross-reference each other and easily locate any incorrectly added data and remove it. The bulk raw data is stored in an off-chain storage (outside of the blockchain ledger) and a hash of this baseline data is stored in the Blockchain ledger via hashing windows of time-series and configuration data, after aggregation and filtering. The bulk off-chain data repository is then considered to be trust-anchored using the hashes stored in the blockchain. To secure the electric grid testbed devices and data, device configuration baselines were compared to those baselines that had been previously stored in the ledger. Statistical baselines for device configurations, network communication patterns, and high-speed sensor data are calculated and then stored off-chain and hashes stored in the ledger. Measurements such as three-phase voltage and current, frequency, breaker status, protection scheme settings, network configuration settings (and other device configuration artifacts) and network traffic features (packet interarrival times) are compared every minute or other selected time windows. During phase 1 of the Grid Guard DLT project different DLT technologies were studies, and an assessment was performed on DLT technology vulnerabilities, uses, and key characteristics. DLT consensus protocols were studies (e.g., RAFT, named after Reliable, Replicated, Redundant, And Fault-Tolerant). Also, cryptography, public, private and permissioned or permissionless systems were assessed. Grid Guard implements a permissioned private DLT. Consensus algorithm selection and choice of DLT implementation depended heavily on the use-case. For this use-case, parameters were selected to measure performance and existing tools for assessment. Benchmarking was performed theoretically and practically. During phase 2 hashed transactions/blocks were inserted into the ledger every second. During phase 2 of the Grid Guard DLT project, a prototype framework was developed and demonstrated for attestation of critical substation devices and data using precision timing systems that use PTP and IRIG-B protocols) on a testbed of operational devices that emulated a distribution substation, control center, and power metering infrastructure using real Operational Technology (OT). The testbed includes OT devices such as protective relays, human machine interfaces (HMI), and power meters. To determine when to collect and compare system and network baselines, an initial examination of an anomaly detection capability to identify malicious manipulation of data streams was conducted. The resulting anomaly detection was demonstrated in a set of experiments and leveraged to trigger device artifact attestation checks. Attestation checks occur against device configuration baselines when compared with the immutable blockchain-stored baselines, which provided a cryptographically supported means by which to store baselines. The electrical substation-grid testbed was created to test the Grid Guard framework. The testbed emulates the operations of a portion of a power grid and SCADA systems as closely as possible. The testbed integrates real protocols, mainly IEC 61850 standard protocols, such as the Sampled Value (SV) and the GOOSE protocols. The testbed also supports DNP3 and other layer 2 and layer 3 protocols such as Telnet, SSH, SFTP/FTP and other proprietary protocols needed to connect to industrial control system equipment. The testbed emulates real power conditions using the OpalRT hardware-in-the-loop (HIL) device which can create fault situations that cannot be easily tested on real systems. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that electrical utilities commonly use.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time-Sensitive Quantum Key Distribution (TSQKD)

This is the final report for the Time-Sensitive Quantum Key Distribution (TSQKD) project and summarizes the demonstration and longer-term field testing at an electric utility, EPB of Chattanooga, in Chattanooga, TN. The demonstration was held virtually (due to the COVID pandemic) and successfully executed the tests outlined in a prior report, “Task 10: Develop a QKD Time-Sensitive Networking Test Suite” submitted 9/30/2020. The portable test equipment explained in Task 10 and earlier task reports was tested at GE Research remotely connected with Qubitekk’s QKD equipment in San Diego, CA. Then the equipment was shipped to Qubitekk for physical integration with Qubitekk’s Quantum DataLoc™ Key Server 1570nm (http://qubitekk.com/products/qkd-for-industrial-control-systems-ics/). The portable test equipment was shipped from Qubitekk to EPB for demonstration and extended field testing. A summary of the demonstration and test results are described in this report. The demo and extended field test results are enabled by the NETCONF/YANG IEEE P1913 data management model developed as part of this project (Task 5). The NETCONF/YANG IEEE P1913 data management model demonstrated significant practical utility in providing a common means of monitoring and configuring the QKD system. All data in this report comes from the IEEE P1913 data management model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study on Conversion from an Existing Alternating Current Medium-Voltage Line to a Direct Current Line: A Case of Load or Source Expansion

Simultaneous increase of power generation through renewable systems and load due owing to the rapid growth in electrified road transportation systems, leads to new challenges in the design, operation, and protection of distribution-level electrical power systems. This paper addresses challenges related to the integration of new sources or loads to a distribution grid through long alternating current lines. The International Council on Large Electric Systems medium-voltage benchmark model developed for North America was used for simulation studies. Use cases were developed to illuminate the issues related to long alternating current lines and the usefulness of medium-voltage direct current lines in a distribution network.

Jaldanki, Sreenivasa↗

A Modeling Toolkit for Comparing AC and DC Electrical Distribution Efficiency in Buildings

Recently, there has been considerable research interest in the potential for DC distribution systems in buildings instead of the traditional AC distribution systems. Due to the need for performing power conversions between DC and AC electricity, DC distribution may provide electrical efficiency advantages in some systems. To support comparative evaluations of AC-only, DC-only, and hybrid AC/DC distribution systems in buildings, a new modeling toolkit called the Building Electrical Efficiency Analysis Model (BEEAM) was developed and is described in this paper. To account for harmonics in currents or voltages arising from nonlinear devices, the toolkit implements harmonic power flow, along with nonlinear device behavioral descriptions derived from empirical measurements. This paper describes the framework, network equations, device representations, and an implementation of the toolkit in an open source software package, including a component library and graphical interface for creating circuits. Simulations of electrical behavior and device and system efficiencies using the toolkit are compared with experimental measurements of a small office environment in a variety of operating and load configurations. A detailed analysis of uncertainty estimation is also provided. Key findings were that a comparison of predicted versus measured efficiencies and power losses in the validation testbed using the initial toolkit implementation predicted device- and system-level efficiencies with reasonably good accuracy under both balanced and unbalanced AC scenarios. An uncertainty analysis also revealed that the maximum estimated error for system efficiency across all scenarios was 3%, and measured and modeled system efficiency agreed within the experimental uncertainty in approximately half of the scenarios. Based on the correspondence between simulation and measurement, the toolkit is proposed by the authors as a potentially useful tool for comparing efficiency in AC, DC, and hybrid AC/DC distribution systems in buildings.

DC distribution↗

Regulatory Protection and Control Standards Applicable to The Vietnam Grid Under High Inverter-Based Resource (IBR) Penetration: A Review of Standards Applicable for Vietnam Grid

This report provides a review of the current standards and practices followed by regulatory authorities for interconnection of inverter-based resources (IBR). With the increased penetration of IBRs into the transmission and distribution networks, the legacy protection methodologies are getting challenged. Due to the lack of regulations on IBR operations under a fault it is essential to have a thorough understanding of the present-day interconnection standards to ensure proper IBR operations. A focus is placed on the regulation and standards enforced by the North American Reliability Corporation (NERC), Federal Energy Regulatory Commission (FERC), Institute of Electrical and Electronics Engineer (IEEE), Underwriters Laboratories (UL) and other regulations proposed by the responsible commissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Deep Generative Model for Non-Intrusive Identification of EV Charging Profiles

The proliferation of electric vehicles (EVs) brings environmental benefits and technical challenges to power grids. An identification algorithm which can accurately extract individual EV charging profiles out of widely available smart meter measurements has attracted great interests. This paper proposes a non-intrusive identification framework for EV charging profile extraction, which is driven by deep generative models (DGM). First, the proposed DGM is designed as a representation layer embedded into the Markov process and used to model the joint probability distribution of available time-series data. A novel contribution is to approximate posterior distributions by neural networks whose parameters are obtained by variational inference and supervised learning. Second, the EV charging status is inferred from the DGM via dynamic programming. Lastly, the desired EV charging profile can be reconstructed by the rated power of EV models and inferred status. Compared with the benchmark Hidden Markov Models, the proposed framework can better handle noise in data with less computational complexity and better overall accuracy performances with smaller recall. The proposed framework is validated by numerical experiments on the Pecan Street dataset.

33 ADVANCED PROPULSION SYSTEMS↗

Spatial Interactions in Hydrogenated Perovskite Nickelate Synaptic Networks

A key aspect of how the brain learns and enables decision-making processes is through synaptic interactions. Electrical transmission and communication in a network of synapses are modulated by extracellular fields generated by ionic chemical gradients. Emulating such spatial interactions in synthetic networks can be of potential use for neuromorphic learning and the hardware implementation of artificial intelligence. Here, in this work, we demonstrate that in a network of hydrogen-doped perovskite nickelate devices, electric bias across a single junction can tune the coupling strength between the neighboring cells. Electrical transport measurements and spatially resolved diffraction and nanoprobe X-ray and scanning microwave impedance spectroscopic studies suggest that graded proton distribution in the inhomogeneous medium of hydrogen-doped nickelate film enables this behavior. We further demonstrate signal integration through the coupling of various junctions.

36 MATERIALS SCIENCE↗

Final Report DE-FE0031785 Mohsen Ahmadian, Ph.D. Demonstration of Proof of Concept of a Multiphysics Approach for Real-Time Remote Monitoring of Dynamic Changes in Pressure and Salinity in Hydraulically Fractured Networks

Hydraulic fracturing has evolved into a multistep process with varying flow rates, carrier fluids (e.g., gel or slickwater), proppant loadings, and proppant grain sizes. As a result, primary recovery from a hydraulically fractured tight-oil reservoir is often a tiny fraction of the original oil in place, ranging between 5 and 10%. As stated in the FOA1990, “part of this problem is due to the inability of current well completion processes to effectively stimulate the entire reservoir volume in contact with the wellbore. Innovative technologies are needed that can help improve the effectiveness of reservoir completion methods, maximize stimulated reservoir volumes, and optimize recovery over the entire producing life span of a well”. We first need to enhance the current fracture diagnostic techniques to improve a well-completion design. However, detecting and delineating a subsurface hydraulic fracture is extremely difficult because the induced fracture network is only fractionally propped, and these propped fractures are generally very thin. Microseismic and tiltmeter monitoring techniques can provide information on the fracture extent but provide little or no information on the movement and final distribution of proppant or production fluids. On the other hand, electromagnetic (EM) imaging has shown the capability to monitor proppant distribution throughout the fracture area, especially in the presence of Electrically Active Proppants (EAPs). A previous EM survey of hydraulic fracturing at the Devine Fracture Pilot Site (DFPS) and subsequent EM code developments demonstrated this survey as a robust technique to remotely interrogate the extent of the EAP-filled hydraulic fracture during its propagation. The objectives of the project were threefold: (1) to capitalize on the material properties of an EAP to demonstrate remote monitoring of relative changes in pressure, pressure, and flow that are commonly encountered during production from a hydraulically fractured reservoir; (2) to evaluate EM imaging tools, to achieve Objective 1 in near real-time; and (3) to develop a multi-physics joint inversion approach to precisely predict flow patterns and physiochemical changes within an EAP-filled fracture network. This research project was built upon our previous work at the Devine Test Site managed by the Bureau of Economic Geology (BEG) at The University of Texas at Austin (UT-Austin). It also leveraged a significant investment from the Advanced Energy Consortium (AEC) to address the DOE's interest in subsurface flow, containment, and characterization by multiple signals. This three-year and three-month project succeeded in demonstrating the feasibility of a real-time dynamic fluid flow mapping technique at Technology Readiness Level 5 (TRL5) by utilizing a commercially available surface-based Controlled-Source Electromagnetic (CSEM) method (Objectives 1, 2). We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, the observed electric field in our study is influenced by bottomhole pressure, flow rate, and salinity, which is demonstrated by comparing these parameters with the electrical field potentials. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce the whole measured electric field magnitudes. Preliminary estimates showed that including Streaming Potential (SP) in our geophysical model is likely needed to reduce the simulation misfit.

02 PETROLEUM↗

Copper–Carbon Nanotube Composites Enabled by Electrospinning for Advanced Conductors

The power losses associated with the electrical resistance of copper (Cu) have generated considerable interest in the development of advanced conductors that incorporate carbon nanotubes (CNTs) into the Cu matrix—ultraconductive Cu (UCC) composites—to increase energy efficiency in various industrial and residential applications, ranging from electric power transmission and rotating machinery to electronic devices. To meet this demand, we describe an electrospinning-based polymer nanofiber templating strategy for the fabrication of UCC composites with electrical and mechanical performance exceeding that of Cu. Our approach involves electrospinning of polyvinylpyrrolidone (PVP)-based solutions containing CNTs into aligned PVP/CNT nanofibers onto Cu foil substrates, followed by vacuum-assisted thermal removal of organic solvent/polymer from the CNT matrix to achieve a uniformly distributed CNT layer on the Cu surface. Following additional Cu deposition, the Cu–CNT–Cu composites demonstrated similar electrical conductivity, higher current carrying capacity, and improved mechanical properties compared with those obtained from reference Cu. Importantly, after the heat treatment, Raman analysis of the CNT network displayed an increased metallic character that supports the enhanced electrical properties of the UCC composites. Thus, we believe that these performance characteristics together with the commercial viability of the present approach could open new possibilities in designing advanced conductors for a broad range of electrical systems and industrial applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Location Selection of Fast-Charging Station for Heavy-Duty EVs Using GIS and Grid Analysis: Preprint

This work presents a systematic methodology for the location selection of fast-charging stations for heavy-duty Electric Vehicles (EVs) based on both geospatial and electrical grid analysis. The geo-spatial analysis is based on real-world geographic information system (GIS) data of road networks and existing supportive infrastructures. The grid analysis is implemented based on node level analysis of potential impacts on voltages and power losses in distribution system. A case study using realistic three-phase unbalanced distribution feeder from California and extracted real-world GIS data is used to demonstrate the intuitiveness and effectiveness of the proposed methodology for the location selection of fast charging station for heavy duty EVs.

47 OTHER INSTRUMENTATION↗

The rise of electric vehicles—2020 status and future expectations

Electric vehicles (EVs) are experiencing a rise in popularity over the past few years as the technology has matured and costs have declined, and support for clean transportation has promoted awareness, increased charging opportunities, and facilitated EV adoption. Suitably, a vast body of literature has been produced exploring various facets of EVs and their role in transportation and energy systems. This paper provides a timely and comprehensive review of scientific studies looking at various aspects of EVs, including: (a) an overview of the status of the light-duty-EV market and current projections for future adoption; (b) insights on market opportunities beyond light-duty EVs; (c) a review of cost and performance evolution for batteries, power electronics, and electric machines that are key components of EV success; (d) charging-infrastructure status with a focus on modeling and studies that are used to project charging-infrastructure requirements and the economics of public charging; (e) an overview of the impact of EV charging on power systems at multiple scales, ranging from bulk power systems to distribution networks; (f) insights into life-cycle cost and emissions studies focusing on EVs; and (g) future expectations and synergies between EVs and other emerging trends and technologies. The goal of this paper is to provide readers with a snapshot of the current state of the art and help navigate this vast literature by comparing studies critically and comprehensively and synthesizing general insights. This detailed review paints a positive picture for the future of EVs for on-road transportation, and the authors remain hopeful that remaining technology, regulatory, societal, behavioral, and business-model barriers can be addressed over time to support a transition toward cleaner, more efficient, and affordable transportation solutions for all.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Microgrid Energy Management System Integration with Advanced Distribution Management System

The Integrated Distribution Management System (IDMS) project was initiated to demonstrate the interactive operation of microgrid systems and the distribution systems with which they interconnect. The key technologies for this are the microgrid management system and the utility distribution management system. The IDMS project successfully demonstrated that a utility’s advanced distribution management system/distributed energy resources management system (ADMS/DERMS) could effectively manage microgrids to provide visibility and control functionalities as well as use the microgrid as a dispatchable resource to support the utility grid. The DERMS accomplishes this by determining active and reactive power needs at the point of common coupling (PCC) using advanced applications like volt/VAR watt optimization (VVWO) and load relief (LR) with the underlying core applications state estimation (SE) and load flow (LF). The ADMS/DERMS can use the microgrid as a resource to resolve and prevent violations in the grid and to optimize the operational working state of the grid. The IDMS project demonstrated that a utility-operated ADMS with embedded DERMS functionality can flexibly manage a variety of microgrids and other aggregated distributed energy resources (DER) in concert with the wider distribution grid. Microgrids can provide grid services in any number of different ways to meet the operational needs of the distribution utility. The manner of aggregation — microgrid or virtual power plant — is not necessarily relevant to the utility as long as the grid services from the aggregated DER are available and can be managed by its ADMS/DERMS for the stability and reliability of the grid. The IDMS project demonstrated this integrated ADMS concept by combining hardware/software-in-the-loop testing with commercial products from different vendors and a utility’s network model. The project integrated the Schneider Electric EcoStruxure™ ADMS with DERMS with the Schweitzer Engineering Laboratories (SEL) POWERMAX ® Microgrid Control System, and the simulated resources with energy company PECO’s model of a utility-owned microgrid, establishing an operational relationship in which the utility manages the operational functionality of a microgrid at the PCC and that provides the utility with the capability to control the comprehensive power system, inclusive of the macrogrid and microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

In-Situ Uranium Source Treatment Performance Assessment Elements - 20247

Field-scale in situ injection of an aqueous polyphosphate amendment was conducted to decrease uranium leaching from a vadose zone source to groundwater near the Columbia River at the U.S. Department of Energy's Hanford Site. After an initial phase of application in November 2015, this treatment was applied as an enhanced attenuation approach in September 2018, targeting uranium in a subsurface zone where water table periodically rises in response to the seasonal high river stage. Uranium within this zone is aqueous, adsorbed, and in low- and high-solubility precipitates and is mobilized into the groundwater at high river stage, resulting in a persistent groundwater plume. The polyphosphate amendment creates phosphate coatings on uranium (potentially including low solubility uranium-phosphate precipitates) that decrease the uranium leached into groundwater when the zone is periodically rewetted to improve the ability of natural attenuation to meet groundwater concentration objectives. For treatment, the amendment was injected into a network of wells within the periodically rewetted source area. Multiple lines of evidence are being applied to evaluate the performance of the phosphate treatment. Three elements of this performance assessment include 1) identifying the distribution of injected phosphate amendment to the targeted treatment zone using cross-borehole electrical resistivity tomography and comparisons of phosphate precipitates between pre- and post-treatment samples, 2) demonstrating the functional reduction in uranium mobility and leachability using laboratory tests with pre- and post- treatment sediments from the source zone, and 3) evaluating the presence of low-solubility uranium phosphate minerals and/or coatings associated with reduced uranium mobility. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Energy and power quality measurement for electrical distribution in AC and DC microgrid buildings

Today's selection of DC microgrid buildings features a diverse set of electrical topologies and turnkey solutions, each with specific design trade-offs and optimizations. Designers desperately need standardized metrics and procedures for measurement and verification (M&V) to analyze and compare the advantages of each DC solution to traditional AC building networks. This work develops M&V procedures for quantifying and comparing the energy efficiency and power quality in buildings. To calculate full-building efficiency, this work introduces the measurement-informed modeling method, a procedure that develops and refines a building's energy model with metered data. To quantify power quality, this work defines a new voltage quality index that applies to both AC and DC buildings. This article describes the equipment, instrumentation, and operation necessary to calculate the efficiency and power quality. It then demonstrates these methods with a set of field tests. We report these M&V procedures can ultimately be used to compare and improve the efficiency and power quality of various DC topologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Finding gaps in the national electric vehicle charging station coverage of the United States

Abstract The United States federal government has invested $7.5 billion into charging infrastructure, including the National Electric Vehicle Infrastructure Program, to build fast charging stations along designated highways for long-distance car travel. We develop a consecutive coverage metric to compute the percent of United States roads (traffic-weighted) that are consecutively accessible within 500 miles of each county. We answer (1) what the state of consecutive coverage is in each county and (2) what the increase in coverage is when designated highways receive fast chargers. In 2023, 10% of counties had at least 75% minimum viable coverage. We find that if all designated highways receive fast-charging stations, 94% of United States counties will reach at least 75% fast charger coverage. However, the remaining counties are rural. This demonstrates that federal funding for fast chargers will help connect most—but not all—counties to the national network of continuously accessible charging stations.

24 POWER TRANSMISSION AND DISTRIBUTION↗