Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy reductions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Decarbonization Technology Snapshot: Heat Pump Water Heaters

Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. In many cases they replace gas-fired water heaters and are significantly more energy efficient, reducing on-site Scope 1 emissions and often resulting in reduced total emissions.

building decarbonization↗

Cosmic ray decreases and shock structure: A multispacecraft study

We examine greater than 60-MeV/amu ion data from three spacecraft (IMP 8 and Helios 1 and 2) at the time of a number of short term (less than 20-day duration) cosmic ray decreases (greater than 1 GeV) detected by ground-based neutron monitors in the years 1976 to 1979. The multispacecraft data allow us to investigate the structure of the modulation region and in particular the relative importance, as a function of location, of the shock and shock driver (ejecta) in causing the reduction in particle densities. Although the shocks contributing to cosmic ray decrease often have particle enhancements associated with them in the greater than 60-meV/amu data, this is not the case for three of the events discussed in this paper where a shock-associated decrease is also evident. Whereas the shock can cause an increase or decrease at low (i.e., less than neutron monitor) energies, the reduction of particle densities in the driver, if it is intercepted, is usually evident at all energies. Thus the overall shape of a decrease at greater than 60 MeV/amu depends primarily on whether the ejecta is intercepted. We find that the particle density inside ejecta increases with increasing radical distance from the Sun. In many of the events in this study, entry and exit of ejecta are accompanied by abrupt changes in the decrease and recovery rates which indicate that the effect of the ejecta is local. In contrast, the effect of the shock lasts many days after the shock has passed by and is evident at large angular distances from the longitude of the solar source, i.e., the effect of the shock is nonlocal. Within 1 AU there seems to be no radial dependence of the shock effect. One cosmic ray decrease seen at Earth, which had an unusual profile, can be understood if the median plane of the ejecta was inclined to the ecliptic.

Cane, H. V.↗

Genetic and Biochemical Investigation of Seed Fatty Acid Accumulation in Arabidopsis

As a vegetable oil, consisting principally of triacylglycerols, is the major storage form of photosynthetically-fixed carbon in oilseeds which are of significant agricultural and industrial value. Photosynthesis in chlorophyll-containing green seeds, along with photosynthesis in leaves and other green organs, generates ATP and reductant (NADPH and NADH) needed for seed fatty acid production. However, contribution of seed photosynthesis to fatty acid accumulation in seeds have not been well-defined. Here, we report the contribution of seed-photosynthesis to fatty acid production by probing segregating green (photosynthetically-competent) and non-green or yellow (photosynthetically-non-competent) seeds in siliques of an Arabidopsis chlorophyll synthase mutant. Using this mutant, we found that yellow seeds lacking photosynthetic capacity reached 80% of amounts of oil in green seeds at maturity. Combining this with studies using shaded siliques, we determined that seed-photosynthesis accounts for 20% and silique and leaf/stem photosynthesis each account for ~40% of the ATP and reductant for seed oil production. Transmission electron microscopy (TEM) and pyridine nucleotides and ATP analyses revealed that seed photosynthesis provides ATP and reductant for oil production mostly during early development, as evidenced by delayed oil accumulation in non-green seeds. Transcriptomic analyses suggests that the oxidative pentose phosphate pathway could be the source of carbon, energy and reductants required for fatty acid synthesis beyond the early stages of seed development.

Nwafor, Chinedu Charles↗

Direct Air Capture of CO 2 and Delivery to Photobioreactors for Algal Biofuel Production (Final Report)

A mobile DAC system was designed and constructed to pair with photobioreactors growing algae for biofuel production. The DAC system was designed as a versatile research system, rather than a compact production unit. The system was constructed and mounted on a mobile skid to facilitate transportation to the algae production site. Within the DAC system, CO 2 was captured using amine-loaded monoliths that allow for high CO 2 uptake with low pressure drop. The CO 2 is collected using a Global Thermostat patented temperature/vacuum swing adsorption (TVSA) process. Amine sorbents and process conditions were optimized to produce 10 to >20 g CO 2 .h-1. The stability of the amine sorbents was also studied, with sorbent modifications made to improve stability to degradation by oxidation. An Algenol-developed Spirulina strain (Arthrospira platensis AB2293) was selected as the production cyanobacterial strain. AB2293 cultured was inoculum for outdoor production following PBR installation by Algenol. The PBR system was composed of three independent PBRs, with each PBR composed of four hanging bags internally recirculated by a liquid turnover pump. The PBRs were operated outdoors in Atlanta, GA, and integrated with the DAC system. Algae were grown with similar productivity using DAC-CO 2 as algae grown using pure CO 2 obtained commercially (Airgas). Throughout the experimental duration, no discoloration was observed, and cellular morphology was consistent between the two experimental treatments. An LCA including lifecycle greenhouse gas emissions, full life cycle inventory of the Algenol system and the DAC system and integrated DAC+PBR system was developed. Lifecycle greenhouse gas emissions were calculated for capture of carbon dioxide using input from Global Thermostat and the National Renewable Energy Laboratory. Three scenarios for energy provision were evaluated: a natural gas combined heat and power system sized to meet the electricity requirement, a natural gas combined heat and power system sized to meet the process heat requirements, and a system without on-site power that procures the electricity from the grid. In all three cases, as expected, the major contributor to the emissions is the energy consumption associated with the desorption step of the DAC process. The LCA quantified the reduced potential energy and greenhouse gas emissions of heat and mass integration of DAC and Algenol compared to unintegrated DAC and Algenol systems. A life cycle assessment of the role of sorbent productivity and lifetime was also developed. The development of more robust, oxidation resistant DAC sorbents may enable small reductions in energy requirements and in lifecycle greenhouse gas emissions and other environmental impacts. NREL performed techno-economic analysis (TEA) to identify the integration scenario most likely to achieve a 15% cost reduction target versus the baseline. Heat and mass integration of DAC and the PBR is critical to minimizing the MFSP. The baseline case utilizes no heat and mass integration, and the DAC system provides 100% of the CO 2 required by the photobioreactors (20 tonnes/hr), operating for 12 hours/day capturing 40 tonnes CO 2 /operating hour. The minimum fuel selling price (MFSP) of ethanol calculated from the baseline case was $10.68/gal ethanol. This corresponds with a targeted MFSP of $9.07/gal ethanol (or 15% reduction). This target was achieved by integration Option 2a with the greatest cost reduction of 17.8% (or $8.78/gal) and integration Option 2b with a cost reduction of 16.4% (or $8.93/gal). Reductions in MFSP are attributed to two primary process considerations: (a) CO 2 storage at night reduces the capital expenses associated with DAC (i.e., increasing on-stream time); and (b) distributed DAC scenarios (DAC-PBR integration Options 2a and 2b) make use of boiler and DAC CHP flue gas CO 2 (free). Direct air capture on-stream time was one of the largest contributors to MFSP reduction.

09 BIOMASS FUELS↗

Supply Chain Energy and Greenhouse Gas Analysis Using the Materials Flows Through Industry (MFI) Tool: Examination of Alternative Technology Scenarios for the U.S. Chemical Sector

Chemical manufacturing is a large and diverse sector of the U.S. economy, with products, fuels, and a wide assortment of materials used daily by both the public and businesses. Currently, several of the largest volume chemicals produced in the United States rely on fossil fuels as a feedstock, energy source, or both. The list of chemicals includes steam cracking products such as ethylene, propylene, benzene, and xylenes as well as products such as ammonia and methanol. The focus for this work is on platform chemicals that are both produced in the largest volume and have a high potential for subsequent processing into more specialized products. In this study, we explore several new pathways that reduce the overall energy consumption and greenhouse gas (GHG) emissions for each product. These pathways include energy efficiency measures applied to existing production methods, the use of bio‐based fuels and/or feedstocks as new production methods, and electrification of high‐energy‐input stages within current production methods. Scenarios for energy demand and GHG reduction were conducted with the National Renewable Energy Laboratory's Materials Flows through Industry tool. Projections of the energy demand and GHG emissions in 2030 and 2050 are included, using grid composition projections from the NREL ReEDS model. The alternative scenarios selected showcase the effect of realistic changes the industry could make, focusing on technologies with a high level of technical readiness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multitask Machine Learning of Collective Variables for Enhanced Sampling of Rare Events

Computing accurate reaction rates is a central challenge in computational chemistry and biology because of the high cost of free energy estimation with unbiased molecular dynamics. In this work, a data-driven machine learning algorithm is devised to learn collective variables with a multitask neural network, where a common upstream part reduces the high dimensionality of atomic configurations to a low dimensional latent space and separate downstream parts map the latent space to predictions of basin class labels and potential energies. Here, the resulting latent space is shown to be an effective low-dimensional representation, capturing the reaction progress and guiding effective umbrella sampling to obtain accurate free energy landscapes. This approach is successfully applied to model systems including a 5D Müller Brown model, a 5D three-well model, the alanine dipeptide in vacuum, and an Au(110) surface reconstruction unit reaction. It enables automated dimensionality reduction for energy controlled reactions in complex systems, offers a unified and data-efficient framework that can be trained with limited data, and outperforms single-task learning approaches, including autoencoders.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Project 1: COLLECTS Project and Project 2: M&V for Saputo Cheese Project: Cooperative Research and Development (Final Report)

Project 1: Combined Power's Hyperlight Energy and NLR will collaborate on the DOE Concentrating Optics for Lower Levelized Energy CosTS (COLLECTS) project, DE-FOA-0001268. COLLECTS funding opportunity announcement (FOA) seeks to further concentrated solar power (CSP) system technologies by soliciting disruptive, transformative projects for the concentrating solar collectors in the CSP plant. These innovative projects will seek to surpass the targets set out in the SunShot Vision Study, enabling CSP to be cost-competitive with conventional forms of electric power generation. Projects will target the design and manufacturing of novel solar collectors with the ability to significantly reduce the solar field contribution to the overall levelized cost of energy (LCOE) of the CSP plant, and which have not been previously specifically targeted by CSP FOAs. Project 2: Hyperlight will perform measurement and verification (M&V) of Green House Gases and NLR will evaluate energy consumption reduction.

14 SOLAR ENERGY↗

Electronically induced defect creation at semiconductor/oxide interface revealed by time-dependent density functional theory

Carrier induced defect creation at the semiconductor-oxide interface has been known as the origin of electronic device degradation for a long time, but how exactly the interface lattice can be damaged by carriers (especially low-energy ones) remains unclear. Here we carry out real-time time-dependent density functional theory simulations on concrete Si/SiO 2 interfaces to study the interaction between excited electrons and interface bonds. We show that the normal interface Si-H bonds are generally resistant to electrons due to the delocalized nature and high energy level of the Si-H antibonding states, and due to the high-energy barrier to break the Si-H bond. However, if an additional hydrogen atom exists by attaching to a nearby oxygen atom (forming a “Si-H···H-O” complex), the Si-H bond will be greatly weakened, including the reduction of energy barrier for bond breaking, and the lowering of the antibonding state energy level which favors electron injection. Together with the multiple vibrational excitation process, the corresponding Si-H bond can be broken much more easily. Thus we propose that the Si-H···H-O complex will be the center for defect creation and device degradation. Finally, we also explain why such a center might be relatively easy to form during the hydrogen annealing process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rating aircraft on energy

Questions concerning the energy efficiency of aircraft compared to ground transport are considered, taking into account as energy intensity the energy consumed per passenger statute mile. It is found that today's transport aircraft have an energy intensity potential comparable to that of ground modes. Possibilities for improving the energy density are also much better in the case of aircraft than in the case of ground transportation. Approaches for potential reductions in aircraft energy consumption are examined, giving attention to steps for increasing the efficiency of present aircraft and to reductions in energy intensity obtainable by the introduction of new aircraft utilizing an advanced technology. The use of supercritical aerodynamics is discussed along with the employment of composite structures, advances in propulsion systems, and the introduction of very large aircraft. Other improvements in fuel economy can be obtained by a reduction of skin-friction drag and a use of hydrogen fuel.

Maddalon, D. V.↗

Effects of ambient temperature on electric vehicle range considering battery Performance, powertrain Efficiency, and HVAC load

Here, this study investigates the impact of ambient temperature on the range of electric vehicles (EVs) by analyzing its effects on usable battery energy (UBE), heating, ventilation, and air conditioning (HVAC) energy consumption, and powertrain energy losses. Chassis dynamometer tests within a thermal chamber were conducted under various temperature conditions to investigate these impacts. The results indicate that lower temperatures lead to a decrease in UBE for lithium-ion batteries in EVs. At −18 °C, the UBE exhibited reductions of 4---8 % compared to the UBE at 22 °C. Battery thermal management strategies significantly affected the UBE loss, with different strategies resulting in distinct UBE reductions. HVAC energy consumption, especially for interior heating, proved to be the most dominant variable affecting EV driving range. Larger discrepancies between the HVAC target temperature (22 °C) and the ambient temperature increased HVAC energy usage. The type of HVAC system also influenced energy consumption, where EVs equipped with heat pumps demonstrated lower energy consumption for heating compared to those relying solely on resistance heaters. Ambient temperature also influenced motor energy consumption due to increased frictions, powertrain losses and tire rolling resistance at lower temperatures; consequently, regenerative braking energy decreased in cold conditions. Combining these effects influenced the overall energy consumption and driving range of EVs. At −18 °C, the driving range saw a substantial decrease of up to 60 % compared to 22 °C, while a slight decrease was observed at 35 °C.

Ambient Temperature↗

Unlocking Manufacturing Sustainability: Energy Efficiency Opportunities through the US Department of Energy’s Better Plants Program Energy Treasure Hunts (2023–2024)

The US manufacturing sector faces critical challenges: improving sustainability, reducing energy consumption, and reducing greenhouse gas emissions. Energy Treasure Hunt (ETH) training, a service provided by the US Department of Energy’s Better Plants program, offers a compelling solution. Although ETHs have traditionally focused on energy and cost savings, data indicate that ETHs can be used to identify opportunities to reduce emissions and water use and to support a sustainable and circular operation. These 3-day on-site events engage employees in a collaborative search for operational and maintenance efficiency improvement opportunities. The success of ETHs lies in a comprehensive methodology. Each phase in an ETH uses various tools and resources to empower employees to identify practical solutions. This study presents data from 13 ETHs conducted between 2023 and 2024 across diverse manufacturing subsectors in the United States and demonstrates that the events can help create a pragmatic decarbonization pathway. Through the events, a total of 234 energy and emissions reduction opportunities were identified, and the potential impact is significant. Implementing the recommendations could translate to annual savings of 497,299 MMBtu of energy, 64,374 kgal of water, and 4.85 million tCO 2 e of emissions. The fiscal savings from the proposed recommendations translate into nearly $\$$5 million annually. This study identifies the opportunities by energy system type and by the specific actions recommended, while also analyzing the identified opportunities, presenting the most established sustainability recommendations. Case studies from participating partners are presented to further demonstrate that ETHs provide a practical and impactful approach to reducing energy consumption, emissions, and operating costs and promote a more sustainable future for the industrial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon-Carbon Turbocharger Housing Unit for Intermittent Combustion Engines

An improved, lightweight, turbine housing unit for an intermittent combustion reciprocating internal combustion engine turbocharger is prepared from a lay-up or molding of carbon-carbon composite materials in a single-piece or two-piece process. When compared to conventional steel or cast iron, the use of carbon-carbon composite materials in a turbine housing unit reduces the overall weight of the engine and reduces the heat energy loss used in the turbocharging process. This reduction in heat energy loss and weight reduction provides for more efficient engine operation.

Northam, G. Burton↗

Expert Elicitation for Tidal Energy Levelized Cost of Energy: Present and Future

In accordance with the Government Performance and Results Act (GPRA), H2O annually assesses marine energy technology development resulting from government-funded research and development programs and strategy. For GPRA reporting, H2O uses the levelized cost of energy (LCOE) - which represents the total system cost per unit of energy produced - to measure the progression of marine energy technology development, assess the impact of their research and development programs, and identify future research priorities. To support H2O's GPRA reporting requirements and inform future strategy, the National Laboratory of the Rockies conducted a tidal energy LCOE expert elicitation study to estimate present and future LCOE[AB2.1]. This report describes the motivation and background for the elicitation study, the methodology used to conduct the study, and the study results. It also provides future recommendations for accelerated tidal energy LCOE reduction based on feedback from study participants.

16 TIDAL AND WAVE POWER↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Meadowview Neighborhood Electrification Project

Awarded a Congressionally Directed Spend (CDS) in 2023, Sacramento Municipal Utility District (SMUD) has successfully executed the Meadowview Neighborhood Electrification Project designed to demonstrate the efficacy of residential energy efficiency and weatherization upgrades for under-resourced communities positively impacting energy use reductions, financial metrics, and indoor air quality. Initially, the project sought to electrify and upgrade 300 homes in Sacramento’s Meadowview neighborhood. However, as interest and momentum grew, the project team proved increasingly efficient and was able to retrofit 374 homes. The project built on SMUD’s years of effort increasing energy efficiency, weatherization, and electrification for low-income residential customers—moving beyond incremental improvements toward full home electrification where it was both feasible and cost-effective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗