Search NASA⌕ Search

SEARCH · Search NASA

Results for “false negative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Evaluating Alerting and Guidance Performance of a UAS Detect-And-Avoid System

A key challenge to the routine, safe operation of unmanned aircraft systems (UAS) is the development of detect-and-avoid (DAA) systems to aid the UAS pilot in remaining "well clear" of nearby aircraft. The goal of this study is to investigate the effect of alerting criteria and pilot response delay on the safety and performance of UAS DAA systems in the context of routine civil UAS operations in the National Airspace System (NAS). A NAS-wide fast-time simulation study was conducted to assess UAS DAA system performance with a large number of encounters and a broad set of DAA alerting and guidance system parameters. Three attributes of the DAA system were controlled as independent variables in the study to conduct trade-off analyses: UAS trajectory prediction method (dead-reckoning vs. intent-based), alerting time threshold (related to predicted time to LoWC), and alerting distance threshold (related to predicted Horizontal Miss Distance, or HMD). A set of metrics, such as the percentage of true positive, false positive, and missed alerts, based on signal detection theory and analysis methods utilizing the Receiver Operating Characteristic (ROC) curves were proposed to evaluate the safety and performance of DAA alerting and guidance systems and aid development of DAA system performance standards. The effect of pilot response delay on the performance of DAA systems was evaluated using a DAA alerting and guidance model and a pilot model developed to support this study. A total of 18 fast-time simulations were conducted with nine different DAA alerting threshold settings and two different trajectory prediction methods, using recorded radar traffic from current Visual Flight Rules (VFR) operations, and supplemented with DAA-equipped UAS traffic based on mission profiles modeling future UAS operations. Results indicate DAA alerting distance threshold has a greater effect on DAA system performance than DAA alerting time threshold or ownship trajectory prediction method. Further analysis on the alert lead time (time in advance of predicted loss of well clear at which a DAA alert is first issued) indicated a strong positive correlation between alert lead time and DAA system performance (i.e. the ability of the UAS pilot to maneuver the unmanned aircraft to remain well clear). While bigger distance thresholds had beneficial effects on alert lead time and missed alert rate, it also generated a higher rate of false alerts. In the design and development of DAA alerting and guidance systems, therefore, the positive and negative effects of false alerts and missed alerts should be carefully considered to achieve acceptable alerting system performance by balancing false and missed alerts. The results and methodology presented in this study are expected to help stakeholders, policymakers and standards committees define the appropriate setting of DAA system parameter thresholds for UAS that ensure safety while minimizing operational impacts to the NAS and equipage requirements for its users before DAA operational performance standards can be finalized.

UAS Detect-and-Avoid (DAA) System↗

ROCker: accurate detection and quantification of target genes in short-read metagenomic data sets by modeling sliding-window bitscores

Functional annotation of metagenomic and metatranscriptomic data sets relies on similarity searches based on e-value thresholds resulting in an unknown number of false positive and negative matches. To overcome these limitations, we introduce ROCker, aimed at identifying position-specific, most-discriminant thresholds in sliding windows along the sequence of a target protein, accounting for non-discriminative domains shared by unrelated proteins. ROCker employs the receiver operating characteristic (ROC) curve to minimize false discovery rate (FDR) and calculate the best thresholds based on how simulated shotgun metagenomic reads of known composition map onto well-curated reference protein sequences and thus, differs from HMM profiles and related methods. We showcase ROCker using ammonia monooxygenase (amoA) and nitrous oxide reductase (nosZ) genes, mediating oxidation of ammonia and the reduction of the potent greenhouse gas, N 2 O, to inert N 2 , respectively. ROCker typically showed 60-fold lower FDR when compared to the common practice of using fixed e-values. Previously uncounted ‘atypical’ nosZ genes were found to be two times more abundant, on average, than their typical counterparts in most soil metagenomes and the abundance of bacterial amoA was quantified against the highly-related particulate methane monooxygenase (pmoA). Therefore, ROCker can reliably detect and quantify target genes in short-read metagenomes.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamics of false vacuum bubbles with nonminimal coupling

We study the dynamics of false vacuum bubbles. A nonminimally coupled scalar field gives rise to the effect of negative tension. The mass of a false vacuum bubble from an outside observer's point of view can be positive, zero, or negative. The interior false vacuum has de Sitter geometry, while the exterior true vacuum background can have geometry depending on the vacuum energy. We show that there exist expanding false vacuum bubbles without the initial singularity in the past.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coregistration of Prechemotherapy PET-CT for Planning Pediatric Hodgkin's Disease Radiotherapy Significantly Diminishes Interobserver Variability of Clinical Target Volume Definition

Purpose: To assess the interobserver variability in clinical target volume (CTV) definitions when using registered {sup 18}F-labeled deoxyglucose positron emission tomography (FDG-PET-CT) versus side-by-side image sets in pediatric Hodgkin's disease (HD). Methods and Materials: Prechemotherapy FDG-PET-CT scans performed in the treatment position were acquired from 20 children (median age, 14 years old) with HD (stages 2A to 4B) and registered with postchemotherapy planning CT scans. The patients had a median age of 14 years and stages of disease ranging between 2A and 4B. Image sets were coregistered using a semiautomatic coregistration system. The biological target volume was defined on all the coregistered images as a guide to defining the initial site of involvement and to avoid false-positive or negative results. Five radiation oncologists independently defined the CTV for all 20 patients: once using separate FDG-PET-CT images as a guide (not registered) to define CTVa and once using the registered FDG-PET-CT data to define CTVb. The total volumes were compared, as well as their coefficients of variation (COV). To assess the interobserver variability, the percentages of intersection between contours drawn by all observers for each patient were calculated for CTVa and for CTVb. Results: The registration of a prechemotherapy FDG-PET-CT scan caused a change in the CTV for all patients. Comparing CTVa with CTVb showed that the mean CTVb increased in 14 patients (range, 0.61%-101.96%) and decreased in 6 patients (range, 2.97%-37.26%). The COV for CTVb significantly decreased for each patient; the mean COVs for CTVa and CTVb were 45% (21%-65%) and 32% (13%-57%), respectively (p = 0.0004). The percentage of intersection among all CTVbs for the five observers increased significantly by 89.77% (1.99%-256.41%) compared to that of CTVa (p = 0.0001). Conclusions: High observer variability can occur during CT-based definition of CTVs for children diagnosed with HD. Registration of FDG-PET and planning CT images resulted in significantly greater consistency of tumor volume definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Open Specy 1.0: Automated (Hyper)spectroscopy for Microplastics

Microplastic spectral analysis is one of the most time-consuming processes in studying microplastic pollution, often requiring days per sample. Researchers are transitioning to automated batch and hyperspectral image analysis techniques to enhance efficiency. Open Specy, initially aimed at manual single-spectrum analysis, has now integrated automated methods. This updated version, Open Specy 1.0, introduces several new features, including two algorithms for automated processing (smoothing and particle compression), an extensive library containing over 40,000 open-source Raman and FTIR spectra, and two machine learning classifiers (logistic regression and k medoids) developed from this library. Furthermore, it includes a revamped user interface, an R package, and a benchmark data set for testing future advancements in automated techniques. Researchers evaluated various configurations for hyperspectral smoothing, particle identification, compression, and splitting, to achieve combined recovery rates between 50 and 150% particle counts, identities, and sizes with a coefficient of variation (CV) of less than 40% (the accredited standard). Mean absorbance times the standard deviation provided a consistent particle identification. Hyperspectral smoothing led to a 96% combined recovery rate and reduced variability (CV = 38%) compared to the 86% recovery (CV = 83%) of nonsmoothed controls. Additionally, compressing spectra for particles was significantly faster (>3x) and showed similar accuracy but with reduced variability than processing each pixel individually. Key challenges persist in automating spectral analysis, particularly in refining particle splitting algorithms, and improving identification routines to minimize false positives and negatives. In conclusion, new methods in sample preparation for better stabilization and dispersion of particles could overcome some of these issues.

13 HYDRO ENERGY↗

Entropy removal of medical diagnostics

Shannon entropy is a core concept in machine learning and information theory, particularly in decision tree modeling. To date, no studies have extensively and quantitatively applied Shannon entropy in a systematic way to quantify the entropy of clinical situations using diagnostic variables (true and false positives and negatives, respectively). Decision tree representations of medical decision-making tools can be generated using diagnostic variables found in literature and entropy removal can be calculated for these tools. This concept of clinical entropy removal has significant potential for further use to bring forth healthcare innovation, such as quantifying the impact of clinical guidelines and value of care and applications to Emergency Medicine scenarios where diagnostic accuracy in a limited time window is paramount. This analysis was done for 623 diagnostic tools and provided unique insights into their utility. For studies that provided detailed data on medical decision-making algorithms, bootstrapped datasets were generated from source data to perform comprehensive machine learning analysis on these algorithms and their constituent steps, which revealed a novel and thorough evaluation of medical diagnostic algorithms.

97 MATHEMATICS AND COMPUTING↗

Genomic Diversity of Escherichia Isolates from Diverse Habitats

Our understanding of the Escherichia genus is heavily biased toward pathogenic or commensal isolates from human or animal hosts. Recent studies have recovered Escherichia isolates that persist, and even grow, outside these hosts. Although the environmental isolates are typically phylogenetically distinct, they are highly related to and phenotypically indistinguishable from their human counterparts, including for the coliform test. To gain insights into the genomic diversity of Escherichia isolates from diverse habitats, including freshwater, soil, animal, and human sources, we carried out comparative DNA-DNA hybridizations using a multi-genome E. coli DNA microarray. The microarray was validated based on hybridizations with selected strains whose genome sequences were available and used to assess the frequency of microarray false positive and negative signals. Our results showed that human fecal isolates share two sets of genes (n>90) that are rarely found among environmental isolates, including genes presumably important for evading host immune mechanisms (e.g., a multi-drug transporter for acids and antimicrobials) and adhering to epithelial cells (e.g., hemolysin E and fimbrial-like adhesin protein). These results imply that environmental isolates are characterized by decreased ability to colonize host cells relative to human isolates. Our study also provides gene markers that can distinguish human isolates from those of warm-blooded animal and environmental origins, and thus can be used to more reliably assess fecal contamination in natural ecosystems.

59 BASIC BIOLOGICAL SCIENCES↗

Improve Replication of In-service Mechanical Environments

Structural dynamic testing is a common method for determining if the design of a component of a system will mechanically fail when deployed into its field environment. To satisfy the test's goal, the mechanical stresses must be replicated. Structural dynamic testing is commonly executed on a shaker table or a shock apparatus such as a drop table or a resonant plate. These apparatus impart a force or load on the component through a test fixture that connects the unit under test to the apparatus. Because the test fixture is directly connected to the unit under test, the fixture modifies the structural dynamics of the system, thus varying the locations and relative levels of stress on the unit under test. This may lead to a false positive or negative indication if the unit under test will fail in its field environment depending on the environment and the test fixture. This body of research utilizes topology optimization using the Plato software to design a test fixture that attaches to the unit under test that matches the dynamic impedance of the next level of assembly. The optimization's objective function is the difference between the field configuration and the laboratory configuration's frequency response functions. It was found that this objective function had many local minima and posed difficulties in converging to an acceptable solution. A case study is presented that uses this objective function and although the results are not perfect, they are quantifiably better than the current method of using a sufficiently stiff fixture.

42 ENGINEERING↗

Accelerated Test Method for Corrosion Protective Coatings Project

This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

Technology Portfolio System↗

Exoplanet Biosignatures: At the Dawn of a New Era of Planetary Observations

The rapid rate of discoveries of exoplanets has expanded the scope of the science possible for the remote detection of life beyond Earth. The Exoplanet Biosignatures Workshop-Without-Walls (EBWWW) held in 2016 engaged the international scientific community across diverse scientific disciplines, to assess the state of the science and technology in the search for life on exoplanets, and to identify paths for progress. The workshop activities resulted in five (5) major review papers which provide: 1) an encyclopedic review of known and proposed biosignatures and models used to ascertain them; 2) an in-depth review of O2 as a biosignature, rigorously examining the nuances of false positives and negatives for evidence of life; 3) a Bayesian framework to comprehensively organize current understanding to quantify confidence in biosignature assessments; 4) an extension of that Bayesian framework in anticipation of increasing planetary data and novel concepts of biosignatures, and 5) a review of the upcoming telescope capabilities to characterize exoplanets and their environment. Because of the immense content of these review papers, this summary provides a guide to their complementary scope and highlights salient features. Strong themes that emerged from the workshop were that biosignatures must be interpreted in the context of their environment, and that frameworks must be developed to link diverse forms of scientific understanding of that context to quantify the likelihood that a biosignature has been observed. Models are needed to explore the parameter space where measurements will be widespread but sparse in detail. Given the technological prospects for large ground-based telescopes and direct imaging from space-based observatories, the detection of atmospheric signatures of a few potentially habitable planets may come before 2030.

spectral imaging↗

CONTAMINATION CONTROL FOR ULTRA-SENSITIVE LIFE DETECTION SCIENCE MISSIONS

"This study report summarizes technological developments in science-required contamination control for cost-capped, life-detection missions in the Solar System. Technology advances focus on developing implementable strategies to restrict contamination of the spacecraft and instruments by the launch vehicle hardware. Secondary bake out operations during cruise further reduce molecular contaminants down to femtomolar levels in the sample path. The study validated a full-spacecraft, deployable barrier design as an effective strategy to isolate the spacecraft from the pre-launch processing and launch environment (e.g., fairing acoustic materials). It accommodates late mounting of RTGs and other required prelaunch activities. A new, high-fidelity physics, contamination-transport model for particles (including cells and their parts) and science-relevant molecules (e.g., possible biomolecules) was developed to validate the barrier concept. Importantly, this model takes into account the physics of extremely clean surfaces achieved by the best traditional contamination engineering. The ability to deal with very low levels of particulate and molecular contamination makes this model unique among standard contamination modeling approaches. Modeling also demonstrated that a high-temperature bake out during interplanetary cruise of the sample collector that comprises the largest surface area in the sample path for an Enceladus orbiter reference mission, was extremely effective. This study included the evaluation of other details necessary for an effective contamination control strategy for life detection missions including feasibility of achieving parts per trillion level cleanliness for semi-volatile hydrocarbons in nitrogen purge gas, identification of launch vehicle services required for the baseline contamination control, and defining additional contamination control measures to be taken during launch operations. Key results of the study are: • New spacecraft barrier design that accommodates RTGs is readily cleanable and repairable. Deployment of a 1/3 scale model was successfully demonstrated. • The barrier reduces particle contamination (likely biological) from fairing to spacecraft by 1e-2 to 1e-3. • On-cruise bake-out of critical surfaces significantly reduced molecular contamination (by as much as 1e-12). Subsequently, the probability of a surface contamination particle being transported to an instrument by an ice particle is less than 5.1e-5 (for microbes specifically, 4.39e-10). The report concludes that a full-spacecraft barrier designed specifically for life-detection missions that require stringent control of particulate and molecular contaminates is an effective means of mitigating risks of false positive and negative results for life signature investigations. Further, secondary cleaning steps for critical sections of the sample path can be highly effective at reducing molecular contaminants to low femtomolar levels."

Contamination↗

Contamination Control for Ultra-Sensitive Life-Detection Missions

"This study report summarizes technological developments in science-required contamination control for cost-capped, life-detection missions in the Solar System. Technology advances focus on developing implementable strategies to restrict contamination of the spacecraft and instruments by the launch vehicle hardware. Secondary bake out operations during cruise further reduce molecular contaminants down to femtomolar levels in the sample path. The study validated a full-spacecraft, deployable barrier design as an effective strategy to isolate the spacecraft from the pre-launch processing and launch environment (e.g., fairing acoustic materials). It accommodates late mounting of RTGs and other required prelaunch activities. A new, high-fidelity physics, contamination-transport model for particles (including cells and their parts) and science-relevant molecules (e.g., possible biomolecules) was developed to validate the barrier concept. Importantly, this model takes into account the physics of extremely clean surfaces achieved by the best traditional contamination engineering. The ability to deal with very low levels of particulate and molecular contamination makes this model unique among standard contamination modeling approaches. Modeling also demonstrated that a high-temperature bake out during interplanetary cruise of the sample collector that comprises the largest surface area in the sample path for an Enceladus orbiter reference mission, was extremely effective. This study included the evaluation of other details necessary for an effective contamination control strategy for life detection missions including feasibility of achieving parts per trillion level cleanliness for semi-volatile hydrocarbons in nitrogen purge gas, identification of launch vehicle services required for the baseline contamination control, and defining additional contamination control measures to be taken during launch operations. Key results of the study are: • New spacecraft barrier design that accommodates RTGs is readily cleanable and repairable. Deployment of a 1/3 scale model was successfully demonstrated. • The barrier reduces particle contamination (likely biological) from fairing to spacecraft by 1e-2 to 1e-3. • On-cruise bake-out of critical surfaces significantly reduced molecular contamination (by as much as 1e-12). Subsequently, the probability of a surface contamination particle being transported to an instrument by an ice particle is less than 5.1e-5 (for microbes specifically, 4.39e-10). The report concludes that a full-spacecraft barrier designed specifically for life-detection missions that require stringent control of particulate and molecular contaminates is an effective means of mitigating risks of false positive and negative results for life signature investigations. Further, secondary cleaning steps for critical sections of the sample path can be highly effective at reducing molecular contaminants to low femtomolar levels."

contamination, life detection, barrier, modeling↗

Structural Analyses and Margins of Safety

There is an increasing reliance on modeling and simulation to verify, quantify, and certify designs of complex structures. The availability of a range of commercial modeling and simulations tools and packages with a variety of capabilities, in conjunction with increased computational resources, is allowing analysts to rapidly perform detailed analyses. However, care should be taken to understand specific tool limitations, assumptions, and boundary conditions as erroneous results can be generated without being recognized by the analysts. In addition, the reported margins of safety should be carefully interrogated to identify any false positive or negative margins and highlight any areas for structural concern.

Structural Analyses↗

Developing Fieldable Systems for Chemical Sensing Using Field Asymmetric Ion Mobility Spectrometry and Mass Spectrometry

Currently, there is an urgent need for field-rugged and field-programmable sensor systems that provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. These devices must be portable, low cost, robust, and provide accurate measurements to avoid both false positive and negative results. Furthermore, the information provided by the devices must be received in a timely manner so that informed decisions can be immediately made and the appropriate actions taken. Two technologies that are unparalleled in their sensitivity, selectivity, and trace-level detection capabilities are field asymmetric ion mobility spectrometry (FAIMS) and mass spectrometry. Here, we will show progress that has been made toward developing fieldable FAIMS systems and mass spectrometers. Working in collaboration with Sionex Corporation, the microDMx detector was equipped with a continuous air sampling system to develop selective methods for the analysis of compounds of interest. A microdiaphragm pump (KNF Neuberger, Inc.) is used to pull in gas-phase analytes directly from the air for separation and detection with the FAIMS system. The FAIMS evaluation platform (SVAC) unit currently measures 9.8-inch x 4.6-inch x 3.2-inch, weighs 3.1 lb, and utilizes a {sup 63}Ni source to ionize incoming compounds. Analytes entering the unit are separated and identified by their characteristic response to the compensation voltage (V{sub c}) at a given rf field strength (V{sub rf}). This response has been observed to be unique for a wide range of substances studied. If additional verification were required or a targeted analyte present in a complex chemical matrix, a FAIMS unit equipped with a fast gas chromatography column has been evaluated. The unit combines the separation capabilities of gas chromatography with the selectivity of FAIMS. It measures 9.5-inch x 5.25-inch x 3.5-inch, weighs 3.8 lb, and uses a 10.6 eV photoionization source. Analytes are identified both by their elution time from the column and by the characteristic response in the FAIMS spectrum. Analysis times required to obtain results for most analytes examined are less than three minutes. A fieldable mass spectrometer system is also being developed that includes sampling, ionization, mass selection and detection, vacuum technology, and analytical methodology with remote data transmission. Multiple methods for mass selection are being explored, including both Penning and Paul type ion traps as well as a quadrupole system to determine which is best suited for a portable mass spectrometer. Several ionization sources and ion counting methods will also be evaluated to establish their effectiveness with each system. The intended result of this project is a handheld mass spectrometer system capable of field deployment for the detection and identification of a wide range of gas-phase CBE species.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-scale experimental validation of thermochemical water-splitting oxides discovered by defect graph neural networks

Thermochemical water-splitting (TCH) based on 2-step thermal redox cycles in metal oxides is a promising approach to generating H 2 , but state-of-the-art (SOTA) CeO 2 has several practical limitations, which has motivated continued materials discovery efforts in this field. Here, in this study, we improve upon a SOTA defect graph neural network (dGNN) surrogate model's oxygen vacancy predictions and combine them with materials project phase diagrams to down-select and discover structurally diverse, experimentally known metal oxides whose TCH performance was previously unknown. Amongst twelve candidates selected based on our high-throughput screening and down-selection criteria, we achieved ∼80% accuracy in identifying materials with stable redox cycling and hydrogen production in stagnation flow reactor water-splitting experiments. Closer to 100% accuracy can be achieved if higher-accuracy, hybrid DFT-predicted vacancy formation energies were computed and used in lieu of the most uncertain dGNN-based screening predictions, as they correct false positives to true negatives. Notably, two discovered candidates, Sr 3 PrMn 2 O 8 and Ba 2 Fe 2 O 5 , display hydrogen yields greater than CeO 2 under specific redox conditions. In conclusion, these results demonstrate our ability to computationally predict and experimentally validate promising candidate TCH materials that have the potential to compete with CeO 2 .

08 HYDROGEN↗

Determination of a Generic Human Error Probability Distribution, Part 1: A Dynamic Formulation of SPAR-H

In almost all major nuclear power plants (NPP) events include a significant human error component. As an example, in Fukushima Daiichi (2011) nuclear meltdown, the human actions related to the high-pressure injection cooling strongly affected accident evolution. Furthermore, in the Three Mile Island accident (1979) (which was initiated by a stuck open valve and thus was triggered a loss of coolant accident) the unit operators made decisions based upon false assumptions that contributed negatively to the accident. Given these premises, the ability to accurately model human interactions with plant evolution and, in particular, dynamically calculate human error probability (HEP) plays a major role in a probabilistic risk analysis (PRA). Human reliability analysis (HRA) identifies and models the causes of human errors, and quantifies HEP by applying different methodologies. HRA methods identify errors and reflect on the understanding of error-prone people and systems. There are a number of HRA methods available that assist in identifying the vulnerabilities in the system and provide guidance in determining the HEP. HEP is the probability of a human failure event (HFE), and quantification of HEPs under various situations is utilized in PRA of large complex systems. One of the more prominent HRA methods is the Standardized Plant Analysis Risk-Human Reliability Analysis (SPAR-H) method that was developed to estimate HEPs for the use in the Standardized Plant Analysis Risk (SPAR) PRA models employed in U.S. NPPs. SPAR-H is implemented in U.S. NPPs by regulators at the U.S. Nuclear Regulatory Commission (NRC) to determine the HEP based on expert estimation through the use of calculation worksheets. In SPAR-H, the nominal HEPs (NHEPs) are multiplied by performance shaping factors (PSF) multiplier values to obtain the overall error probability. PSFs encompass the human components, individual characteristics, their environment, and aspects of the task. With PSFs, the goal is to capture all factors that can affect human performance. In SPAR-H there are eight PSFs used, each having respective levels corresponding to multipliers: Available Time, Stress/Stressors, Complexity, Experience/Training, Procedures, Ergonomics/Human Machine Interface, Fitness for Duty, and Work Processes. The PSF multipliers indicate enhanced, nominal, or degraded human performance. The SPAR-H method estimates the HEP through multiplying a NHEP with PSFs. Hence, SPAR-H is a traditional HRA method that assesses human performance at a fixed, or static, point in time. In a dynamic HRA framework, human performance is assessed on a continuous time basis. SPAR-H can be used within a dynamic PRA framework through the use of simulation and stochastic models. The goal of dynamic HRA is to build a more realistic model of the human-system interaction to enhance calculation of reliability, risk and safety analysis. The progression of events in dynamic SPAR-H considers that some PSFs may experience gradual change, while other change can be sudden due to individualistic differences or rapid plant status changes. The PSF changes are caused by contextual changes in the scenario. For example, as more time passes, the realization that a task should be completed sooner may cause the operator more stress. In another example, a sudden relay of information about sickness of a family member may alter the operator's general stress level and fitness for duty. Each PSF has a different dynamic nature; PSFs like stress and complexity change more quickly over the course of a task than experience and training. While the experience of an operator changes over the course of attaining the objective, the amount that this added experience changes the HEP is very minimal. In contrast, the stress, complexity, and procedures PSFs may change quite a bit over the course of task completion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamics of false vacuum bubbles in Brans-Dicke theory

We study the dynamics of false vacuum bubbles in the Brans-Dicke theory of gravity by using the thin shell or thin wall approximation. We consider a false vacuum bubble that has a different value for the Brans-Dicke field between the inside false vacuum region and the outside true vacuum region. Within a certain limit of field values, the difference of field values makes the effective tension of the shell negative. This allows new expanding false vacuum bubbles to be seen by the outside observer, which are disallowed in Einstein gravity.

79 ASTRONOMY AND ASTROPHYSICS↗